Home

user manual

image

Contents

1. Cable route dual display Cable from slot 2 Cable route dual display Cable from slot 2 Cable from slot 3 Securing the cable clips FX 120 battery operation Note Battery operation is not available on the FX110 Plug the battery pack into the scale use 6 x 1 5v 2 D size cells and place the pack into the recess Replace the cover and weighplate Caution To avoid damage to the scale caused by leaking batteries remove flat or damaged batteries immediately Please note Rechargable NiCad batteries are not suitable for this application due to their inherent short circuit thermal characteristics which can adversely affect the performance of the scale ARE When you see the MB symbol flashing on the display or Battery LED flashing then you must either replace the batteries or recharge the rechargeable battery Using a
2. 1 Make sure that the work surface is firm steady and free from vibration and draughts A gt H 2 Hold the scale by the base when picking up Do not pick up the scale by the weigh plate or cross CEA x 27 3 Adjust the feet if the scale is not level FX110 Installation FX120 z To avoid the risk of RSI Repetitive Strain Injury it is important to ensure that the machine is placed on a surface which is ergonomically satisfactory to the user In cases where usage is prolonged EN614 1 recommends frequent breaks for the user FX 110 connections Power Display Programming RS 232 Serial FX 120 connections 1 Remove weigh plate 2 Connect power cable Fitting the FX 120 scale mounted display 1 Make sure the scale is not connected to the power supply and remove weigh plate 2 Turn over machine and place on a safe
3. averyberkel com Internet http www averyberkel com
4. FX 110 FX 120 User Instructions Weight Only Scale Issue 2 Brisch number 76103 390 09 08 02 ENGLISH LOWELL LIL UJ Avery Berkel Limited 2001 All rights reserved The information contained herein is the property of Avery Berkel Limited and is supplied without liability for errors and omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied Warnings For your protection all mains 110V or 230V equipment used where damp or wet conditions may occur must be supplied from a correctly fused source and protected by an approved RCD to BS7071 or BS7288 or IEC1008 2 2 BS EN 61008 1995 IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN To avoid the possibility of electric shock or damage to the machine always isolate from the mains power supply before carrying out any routine maintenance Cleaning the scale Harsh abrasives solvents scouring cleaners and alkaline cleaning solutions such as washing soda should not be used especially on the display windows Under no circumstances should you attempt to wipe the inside of the machine The outside of the machine may be wiped down with a clean cloth moistened with water containing a small amount of washing up liquid Installation FX110 only Remove parts 1 4 before installing the machine
5. MM DMA of BROOKS se Or LCL KLIN LCD LED Displaying service information wo Midi 0 1 Net I ei zn a a pe m tf tint LED i 01 17 U Resetting the machine 7 Net 20e un Net UJ TO DA DA EA EA EE kg Fonn he wa A RA NII 571009 a Ju LAL KN GA Or MOL LL Press and hold LCD LED Press and hold Waking up the scale Depending on configuration X Either N Or EE Zeroing the scale Make sure that the scale is at zero before weighing any goods A el pd amp FMV ma m tea rere rere Mau ar AARIN LCD LED Weighing goods Place the goods onto the scale EN p To cancel a tare gt Using tares a a im Cumulative tare Repeat uniil all the goods have been weighed Management Mode Entering management mode 4 lE B 4 I m up a ae lant p Cay wa 17 Ba a r Net GN NT WI 8 kg SHORE Roi o ADADAN LCD LED Navigating management mode Branch 2 95 Sub branch For Example Value Branch 12 LSub branch 98 Branch 13 Sub branch Go to the previous branch press and hold Sub branch Go to previous sub branch Go to the next branch press and hold Go to next sub branch 5 i Laka Sets the value to 0 enabling you to display a new value Return to Branch 00 press and hold Displays the val
6. level surface C cp el ch ji o T fa Q Ga E 3 Turn the machine round so the required mounting slot is next to the edge of the counter Slot 1 ee Slot 3 required mounting slot 4 Remove the screw in the mounting slot t G 5 Place the mounting bracket into the slot LP S 97 6 Place washer over screw hole and fix with the large replacement screw i NS 7 Refer to the drawings on the following pages and e Plug the display cable into the base e Feed the slack cable round the base e Secure the cable clips 8 Place machine upright Caution Do not lift the scale by the column display or the weighplate Cable route single display Cable from slot 3 Cable from slot 2 Cable route dual display Cable from slot 3
7. on For example 200 2 seconds 150 1 seconds 100 1 second Enabling key timeout Go to branch 74 Sub branch 01 MULI 0 Disabled 1 Enabled Changing the timeout period Go to branch 74 Sub branch 02 34 80 Enter a value in units of 10 milliseconds 1 255 20 For example 200 2 seconds 150 172 seconds 100 1 second CG Declaration of Conformity The non automatic weighing instrument Manufacturer Avery Berkel Type FX 110 Number of EC type approval certificate UK 2625 Manufacturer Avery Berkel Type FX 120 Number of EC type approval certificate T5532 Corresponds to the requirements of the following EC directives Non Automatic Weighing Instruments Directive 90 384 EEC EMC Directive 89 336 EEC Low Voltage Directive 73 23 EEC The applicable harmonised standards are EN 45 501 EN 50 081 1 EN 60 950 EMC Compliance This is a class A product In a domestic environment this product may cause radio interference in whch case the user may be required to take adequate measures This declaration is only valid if the non automatic weighing instrument was verified by the manufacturer or with a certificate of conformity issued by a notified authority A copy of the original signed declaration for this instrument is available from Foundry Lane Smethwick West Midlands England B66 2LP Email sales averyberkel com Info
8. rechargeable battery pack Plug the rechargeable battery pack into the scale and place the pack into the recess Replace the cover and weighplate Recharging the battery pack Plug the mains cable into the socket located on the base of the scale then switch on using the mains ON OFF switch Note You can still use the scale while the battery is being charged Error messages If a persistent error message appears or the scale locks up F 30 disconnect then reconnect the scale to the power supply If the scale remains inoperative contact your authorised service agent Temporary Weight Balance Under Over error unsteady failed range range Error codes 10 Battery failure 11 Power supply voltage is too high 30 Memory checksum invalid 35 Prohibited function 36 Prohibited scale capacity TI TI TI TI TI Contact your service agent if you see any other F messeges 120 Tare weight unsteady 121 Tare too heavy 122 Tare already in operation 123 Cannot use EPOS tare 124 Mismatch between EPOS and scale tare increments 130 Unit price not accepted 131 Scale has not returned to zero between EPOS transactions m m mm m m rm m Using the scale Testing the display Net 0 en Net PO OOO EOE kg Cra To Bron M
9. ue Press again to re display the branch sub branch BSE After clearing a value to be changed each key press increments the value displayed Pressing and holding the key increments the value by 10 Note After changing a value you must go to the next branch to accept the value Exit management mode Press and hold Example turn the keyboard bleeper off and change the backlight time to 5 seconds BBB ES 900 EGP LL A LIL 13 4 Press and hold g mrm Lt Lt LIL Press and hold Q P mm LLU Press and hold l Press and hold Switching the bleeper alarm on off Go to branch 19 Sub branch 00 1900 0 Off 1 On Switching the keyboard bleeper on off Go to branch 19 Sub branch 01 1901 0 Off 1 On Target bleep Branch 19 Sub branch 02 Not applicable for this machine Error bleeper Go to branch 19 Sub branch 03 195 o Off 1 On Changing the bleeper volume Go to branch 19 Sub branch 04 19 04 0 Quiet 1 Loud I Changing the backlight time Go to branch 20 Sub branch 00 PULL 0 always off 1 5 seconds 2 1 minute 3 5 minutes 4 always on Changing the sleep time Go to branch 20 Sub branch 01 ELU I 0 none 1 1 minute 2 5 minutes 3 30 minutes Changing the duration of a Long press press and hold Go to branch 29 Sub branch 00 SUL Enter a value in units of 10 milliseconds 50 255 e

Download Pdf Manuals

image

Related Search

Related Contents

MAGNUM Operators Guide  4-20 mA Output Guide  Holmes HASF1522RCI User's Manual  UNIVERSIDADE ESTÁCIO DE SÁ ANDRÉ GUSTAVO CORRÊA  Leica iCON excavate iCP31 User Manual  Fenêtre sur Cour  Pr o Minent  Laver et sécher dans les immeubles locatifs  3G Fixed Wireless Terminal FCT-355 User Manual  1. Montage  

Copyright © All rights reserved.
Failed to retrieve file