III. Installation of the Controller

image

Contents

1. 1 Controllers User s manual ST 280 ST 280 user s manual Table of contents E SU Z A 3 II DEVICOZDESCHDELO R cT 4 Ill dinstalation or the Controle suas Vete da deudor Ek A ias 5 IV Operation of the Controller ads 8 Iva OperatifigPHIIDGIDIGs quisa ii 8 IVb Main Screen Descriptio smc REIS A AS 8 V Controller Functions Menu Options dadas 12 Vka TIM TEDE Ewki Wap ences ka Ja 14 MID ES a A a 15 VLEI SGT EN SU I UT III S 16 Vad Weekly CONTO eraio aa aa aaa aa a a a a aaa a aa a 17 VLE BOller Controla A A E A A 18 Vit Language Selecione 20 VI g Information about the Operating Program s sssssssssssssssssssssennensnnrsnenesnsnennsnennssrenenenne 20 VID S ENS m ERN 20 Ix ASA A 21 i eo BH I Safety Please read the following regulations carefully before using the device Failure to comply with these instructions may cause injuries and damage to the device This instruction booklet should be carefully stored To avoid unnecessary errors and accidents ensure that all people who use this device become familiar with its operation and safety functions Please keep these instructions and make sure that they accompany the device in the case of its transfer or sale so that any user during the period of its use will have the appropriate information and instruction on device operation and safety For safety of life and property follow precautions consistent with those listed in the operating ma
2. 280 user s manual Room temperature switch off After clicking on this icon you will see the panel with which you can set the threshold temperature in the room if temperature in the room goes up above the set value the boiler will switch off independently of the set temporary schedule Submenu for the Installation Controller e Operating modes After clicking on this icon you can easily change the pumps operation mode with the boiler controller between Home heating Priority parallel pumps summer mode A more detailed description of these operating modes can be found in the operation manual for the boiler controller VI f Language Selection After clicking on the Language selection icon on the main menu you will see the panel used for changing the language for the user gt Wyj cie Wyj cie bh VI g Information about the Operating Program By clicking on this icon the display will show the boiler manufacturer s logo along with the software version VI h Settings After clicking on this icon you can change additional parameters Temperature Sensor After clicking on this icon you can see the panel which allows the user to change the hysteresis settings and calibration of the temperature sensor of the room regulator e Hysteresis Hysteresis introduces tolerance for the set temperature preventing unwanted oscillations under minimal temperature fluctuations 0 10 C with accuracy to 0 1 C Exa
3. hours the controller will switch to the night mode Night from hour as well as return to the day mode Day from hour Brightness during the day brightness at night After clicking on the icon the user may set the percentage value of the screen brightness during the day and at night VI d Weekly Control This function allows you to change the set temperature of the room in a day night cycle You can set each day you can set the device to change to a specific temperature at any hour on the main set value in a 24 hour day night cycle First select the day on which time deviations will be set for this option click on the Settings icon and then select the day for which you want to set the temperature After selecting the day you will see the panel for setting temperature deviations within selected time intervals To facilitate this you can copy the set deviation for subsequent hours just click on the symbol on the selected value and by means of the arrows copy selected settings for subsequent hours gt 4 Delete Copy Exit 17 ST 280 users manual By clicking on the Copy icon you can copy the settings of any whole day for the subsequent days Monday Tuesday Wednesday Weekly setting of the set temperatures reduces heating costs and provides the desired level of thermal comfort throughout the whole day The parameter which determines the correct operation of this function is the current time and day set
4. 22 Wieprz with full liability declares that the manufactured ST 280 230 V 50 Hz thermo regulator complies with requirements of the Regulation of the Minister of Economy Labour and Social Policy Journal of Laws no 155 item 1089 of 21 August 2007 implementing provisions of Low Voltage Directive LVD 2006 95 EC the Act of 13 April 2007 on Electromagnetic Compatibility Official Journal 07 82 556 implementing provisions of Directive EMC 2004 108 EC and the Regulation of the Minister of Economy of 8 May 2013 on the basic requirements concerning restrictions of usage some hazardous substances in electrical and electronic equipment implementing provisions of ROHS Directive 2011 65 EC For conformity assessment harmonized standards were used PN EN 60730 2 9 2011 PN EN 60730 1 2012 The product was CE marked 03 2012 A E p LES ARES gt NN A Y A C j V o a pi yak ant Pavel JURA ANUSZ MASTER W A CICIELE TECH SP Wieprz 21 V 2015 22 io TFT Care for the natural environment is of primary importance for us We are aware of the fact that we manufacture electronic devices and it obligates us to dispose used elements and electronic equipment in a manner which is safe for the nature As a result the company received a registry number assigned by the Chief Inspector of Environmental Protection The symbol of a crossed out disposal bin on the product means that the product must not be thrown out to genera
5. The controller on the boiler should be connected to the v1 module by means of a 4 wired cable and connected at the other end to the RJ12 connector on the connection scheme this is marked as point 1 Optionally a vertical 6 connector may be used instead y ST 280 users manual IV Operation of the Controller IVa Operating Principle The room regulator sends a signal on additional heating or underheating to the main controller Depending on the specific settings the signal for additional heating of rooms may e g switch off the CH pump reduce the set temperature of the boiler by the set one settings can be adjusted with the main controller The room regulator also enables change of some settings within the main controller e g ability to change and set the temperature of the boiler pump operation modes etc IVb Main Screen Description The controller is equipped with a large touch screen display The main screen displays the current state of basic parameters for the boiler Depending on the user s settings the screen may display a visible installation screen or the panels screen Data which is displayed on the main screen of the room regulator depends on settings of the main controller and its type A NOTE Each change of the set temperatures time or other settings on the room regulator or boiler controller introduces a new setting in both devices A NOTE Factory settings show the main screen as the installation screen w
6. he boiler operations s E 18 io SH Temporary operation after marking this icon the boiler will operate only at the set hours Continuous operation after marking this icon the boiler will operate continuously Settings after clicking on this icon you can set the boiler operations in detail Selection of the mode After selection of the operation hours only setting the boiler will switch on and off according to the schedule set by the user When selecting the operation hours and room temperature the boiler will switch on in accordance of the current temperature inside the room and in accordance with the schedule of the boilers daily operations The current temperature inside the room is the priority for boiler under operation in this mode if the temperature in the room falls below the threshold temperature determined by the user the boiler will be switched on even if the schedule states otherwise Operating hours After clicking on this icon you can set on which hours Daily furnace OPE the boiler must be switched on and off 30 minute time intervals me Re UE i E 3 IB Copy Exit Room temperature switch on After clicking on this icon you will see the panel with which you can set the threshold temperature in the room if the temperature in the room falls below the set value the boiler will switch on independently of the set temporary schedule 19 ST
7. hich the user may change on the panels screen Main Screen Description Installation Screen I 3 E Menu N FP elas 8 A i eo Pa Temperature of smoke visible only when using the smoke sensor on the main controller Current time and date clicking the screen in this area will switch you to the Time menu which enables you to introduce changes to the current time and date Icon which signals activated options concerning daily boiler operations only in the case of the pellet type boiler Icon which signals an activated alarm clock Icon which signals an activated weekly control Access to the controller menu Valve 1 temperature current and set clicking the screen in this area will switch you to the menu which enables you to introduce changes to the set temperature of valve 1 Valve 2 temperature current and set clicking the screen in this area will switch you to the menu which enables you to introduce changes to the set temperature of valve 2 NOTE Data concerning the valve must be loaded and registered in order to be displayed on the main screen of the room regulator on the main controller in the case of external modules of the valve e g the ST 431N In the circumstance of the valve not being installed the room regulator will display an icon 9 10 11 12 13 14 15 16 Boiler 1 temperature current and set clicking the screen in this area will switch you to the men
8. ightness at Night Activated Disabled Settings Submenu Subject to the Type of the Main Controller Temperature Sensor Main Controller Type Built in Timer 13 ra eee ee io Pa Disabled Active on Selected Days At Once Waking Hour Day Activated Disabled Screensaver Selection Import of Photos Idle Time Duration of the Slide Panels Screen Installation Screen Hysteresis Calibration Standard Controller Pellet Controller Installation Controller ST 280 users manual VI a Time After clicking on the Time icon on the main menu you will see the panel used for changing timer settings current date and alarm clock settings Timer This function allows the user to set the current time according to which the regulator will then operate Date This function allows the user to set the current date according to which the regulator will then operate Alarm clock This function allows the user to set the alarm clock There is an option to set the alarm clock so that it will activate only on selected days active on selected days or whether it will activate once each time 14 i eo Pa waking hour can be set by means of using the up and down arrows when the alarm clock is to be active only on selected days the user must select the days on which the alarm clock is to be activated Controller screen view at the time of activation of the alarm cloc
9. ion 4 Icon which shows an activated alarm clock 5 External temperature visible only when using the external sensor on the main controller 6 Current room temperature 7 Current time and date 8 Right parameters panel 9 Buttons allowing change of active view of parameters panel 10 Access to the controller menu 11 Left parameters panel With the use of buttons allowing change of active view of parameters panels the user obtains access to additional information on the installation condition Room temperature panel View of current temperature and the set temperature inside the room after clicking on this panel it is possible to change the set room temperature 10 io Pa e Boiler temperature panel View of current temperature and the set temperature of the boiler after clicking on this panel it is possible to change the set temperature of the boiler e Boiler temperature panel View of the current temperature and the set temperature of the boiler after clicking on this panel it is possible to change the set temperature of the boiler e Valves data panel View of the current temperature and set temperature of valve 1 2 3 or 4 after clicking on this panel it is possible to change the set temperature of the selected valve e Fuel level panel View of the fuel level in the boiler this mode is only active when selected by the user with the boiler controller e Charts panel Current tempera
10. ith the main controller should be connected with a four wired cable according to the scheme below room regulator rear wall o viov M CN E ZU J 2 n Be o ETA YELLOW 7 ra sa Room regulator power supply The four wired cable is connected to the regulator inputs in accordance with colours of wires The cable is then connected to RJ12 connector which you should plug into the regulator power supply the place of connection is marked on the scheme as point 2 there is additional description on the power supply The regulator power supply should be connected to the controller on the boiler by means of a 4 wired cable connected on both sides to the RJ12 connector marked on the connection scheme as point 1 l ELLF Scheme of Connections Wireless Connection Using the ST 260 set you can combine the ST 280 room regulator with the main controller in a wireless manner Connections should be carried out in accordance with the following scheme room regulator rear wall V1 V2 ST 260 set o viov M CN Re gt A mE e a 5 NEN Wireless communication set ST 260 The four wired cable is connected to the regulator connector in accordance with colours of wires This cable is then connected to the RJ12 connector and should be plugged into the v2 module the place of connection is marked on the scheme as point 2 there is an additional description on the module
11. k VI b Securities After clicking on the Securities icon on the main menu you will see the panel used for changing settings of the parental lock Auto Lock After clicking on the Auto lock icon you will see the panel used for switching the parental lock on or Off 15 ST 280 user s manual PIN Code In order to set the PIN code necessary for regulator operation when the lock is active you must click PIN code icon A NOTE The factory set PIN code is 0000 VI c Screen After clicking on the Screen icon on the main menu you will see the panel used for changing the screen settings Screensaver On the controller it is possible to set the screensaver which will activate after a fixed idle time In order to return to the main screen view it is enough to touch any place on the screen The user may adjust the screen view during the screen time out by setting particular parameters e Screensaver selection By clicking selection of the screensaver you switch to the panel which enables you to turn off the screensaver option No screensaver or set the screensaver in the form of slideshow activation of this option is possible only after prior activation of the photos import option Photos are displayed on the screen with a frequency set by the user Timer visible on the screen Time out after expiration of the set idle time the screen will switch to stand by function e Import of Photos Any photos yo
12. l waste bins By segregating waste intended for recycling we help to protect the natural environment It is the user s responsibility to transfer waste equipment to the selected collection point for the recycling of waste generated from electrical and electronic equipment 23 gt q ontrollers_ SERWIS 32 652 Bulowice Skotnica 120 Tel 48 33 8759380 48 33 3300018 48 33 8751920 48 33 8704700 Fax 48 33 8454547 serwis techsterowniki pl Monday Friday 7 00 16 00 Saturday 9 00 12 00
13. mple when the set temperature constitutes 230C and hysteresis is set to 1 C the room regulator will begin to indicate under heating in the room after the temperature Exit falls to 22 C e Calibration Calibration of the device is set during the installation It can additionally be set after a longer period of 20 io SH use of the regulator if the room temperature measured by the internal sensor differs from the current temperature The regulation range is as follows 10 to 10 C with accuracy to 0 1 C Main Controller Type After clicking on this icon the user selects the main controller type with which room regulator will cooperate standard pellet or installation After the selection is made the Boiler control submenu will be changed I Alarms The ST 280 room temperature regulator will signal all alarms generated by the main controller When the alarm activates the room regulator will send sound signals and the display will show the same message as the boiler controller In the case of internal sensor damage room temperature sensor fault will appear Technical data Room temperature settings range 5 C 40 C Power supply voltage 5 V DC Power consumption 1 3 W Room temperature measurement error 0 1 C Operating temperature 5 C 50 C 21 ST 280 user s manual Declaration of conformity no 56 2012 TECH company with its registered office in Wieprz 1047A 34 1
14. n controllers Its large legible colourful touch screen display allows for convenient operation of the regulator and modulation of its parameters An additional advantage is the possibility to load photos to the controller s memory which will be displayed as a screensaver The ST 280 room regulator enables e Control of room temperature Control of the CH pump temperature Control of the DHW temperature Control of the mixing valves temperature available in cooperation with an additional valve module View of external temperature Weekly heating program Alarm clock Parental lock Display of current boiler temperature and room temperature Controller equipment e Large legible colourful touch screen display e Built in room sensor e RS communication cable for boiler controller e RS wireless communication module ST 260 additional option 12 00 Niedziela 60 622 11659 1659 gt ST 280 i ee a III Installation of the Controller The controller should be installed by a person with the relevant qualifications A WARNING There is a danger of fatal electrical shock from touching live connections You must disconnect the electrical connection and protect against accidental connection before working with the regulator The ST 280 regulator is intended for installation on the wall 88 145 ST 280 users manual Scheme of connections Wire Connection The ST 280 room regulator along w
15. nual as the manufacturer shall not be held liable for damage caused by negligence WARNING e Live electrical device Before any activities related to power supply connecting wires device installation etc you must ensure that the regulator is not connected to the electrical grid Installation should be carried out by a person with the appropriate electrical authorizations e You must measure the resistance of electrical motors earthing and resistance of electrical wires insulation before activating the controller e The regulator is not intended for operation by children A NOTE e Atmospheric discharges may damage the controller therefore during storms it is necessary to disconnect the device from the electrical grid by pulling out the power plug The controller must be used in accordance with its intended purpose e Please check the technical condition of wires before and throughout the heating season Fas tening of the controller should be also checked and any dust and dirt should be cleaned ST 280 user s manual II Device Description Application of the ST 280 room regulator provides convenient steering and control of room temperature boiler tank and mixing valves directly from home without the need to go down to the boiler room The controller is adapted to cooperate with various kinds of main controllers equipped with RS communication standard controllers pellet controllers equipped with ignition switch and installatio
16. tings Thursday Friday Saturday VI e Boiler Control The parameters of this submenu depend on the main controller type Submenu for Standard Controller e Set temperature After clicking on this icon you can change the value of set temperature on the boiler you can do this by clicking on view of parameters from the starting screen e Operation modes After clicking on this icon you can easily change the pumps operation mode in the boiler controller between Home heating Priority parallel pumps summer mode More detailed descriptions of these operating modes can be found in the operation manual for the boiler controller Submenu for the pellet controller e Set temperature After clicking on this icon you can change the value of the set temperature on the boiler you can do this by clicking on view of parameters from the starting screen e Lighting By clicking on this icon you will activate the process of lightning the boiler e Extinguishing By clicking on this icon you will activated the process of extinguishing the boiler e Operating mode After clicking on this icon you can easily change the pumps operation mode on the boiler controller between Home heating Priority parallel pumps Summer mode More detailed descriptions of these operating modes can be found in the operation manual for the boiler controller e Boiler daily operation By clicking on this icon you can set the daily schedule of k t
17. ture chart boiler tank or inside the room graphically presents temperature changes in time 11 ST 280 users manual e Pellet boiler change phase panel This sub menu allows the user to enable or disable the boiler This option is only unavailable during daily boiler operations which fall 2 Lighting up under temporary operation settings U Extinguishing e Pump operation mode change panel View of the operation mode shows the active pumps operation mode active view only in the case of the pellet type boiler after clicking on this panel it is possible to change the pumps operation mode A selection can be made from among the following modes Home heating Priority parallel pumps summer mode with additional heating and summer mode without additional heating Detailed description of pumps operation modes can be found in the operation manual of the boiler controller V Controller Functions Menu Options During normal operation of the regulator the devices home page is visible on the graphic display After clicking on the menu the user is switched to that particular controller function 12 Main Menu Time Securities Screen Weekly control Boiler Control Language Selection Information about the Operating Program Settings Timer Day Alarm Clock Auto Lock PIN Code Screensaver Screen View Night from Hour Day from Hour Brightness During the Day Br
18. u want to import to the controller s memory WG AN EAN must be first prepared by means of using the ImageClip u program download from www techsterowniki pl After installation and starting up the program on a PC you will be able to load your selected photos You can also select the area of the photos to be displayed on the controller screen You can turn photos After processing the selected photos the program will load them After preparation of all the photos you want to load to the controller save them on a USB stick in the main menu Insert the USB stick into the USB port on the controller and launch the photos Import option on the controller menu You can load up to 8 photos at any one time Loading new photos automatically into the controller memory will remove previous photos Screenshot of the photo editing program intended for ST 282 controller e Idle Time This function enables you to set the time after which the screensaver will activate e Duration of the Slide This option enables you to set the frequency with which photos will be changed if the slideshow is activated 16 Zi GERE NH NA Screen View After clicking on the screen view icon the user has the ability to set the appearance of the main screen By default it is set to the pre installed screen but you can also set the panel screen Eg Exit Night from hour Day from hour 5 In further sub menus of the screen menu you can decide which
19. u which enables you to introduce changes to the set temperature of the boiler Icon which signals circulation pump animation which displays current pump operation Icon which signals HUW pump animation which displays current pump operation Icon which signals CH pump animation which displays current pump operation Boiler temperature current and set If the third temperature value is displayed it means that weekly control is activated and this value indicates the current adjustment of the set tempera ture of the boiler Clicking the screen in this area will switch you to the menu which enables you to change the set temperature of the boiler The current level of fuel in the feeder External temperature visible only when using the external sensor in the main controller Room temperature current and set If the third temperature value is displayed it means that weekly control is activated and this value indicates the current adjustment of the set room temperature Clicking the screen in this area will switch you to the menu which enables you to change the set room temperature ST 280 user s manual Main Screen Description Panels Screen 2 sf gt LI ma nf 27 ty Menu 0d 1 Active operation mode of pumps 2 Icon which shows enabled options concerning daily boiler operations only in the case of the pellet type boiler 3 Icon which shows an enabled weekly control opt