1. POWER CHARGING F Litt i FAULT e Bulk Charge Charges using a constant maximum current 1A until the battery reaches 7 2V 6 Volt Batteries or 14 4V 12 Volt Batteries LED Color Yellow e Fully Float Battery is fully charged and is being maintained LED Color GREEN STEP 4 Disconnecting the Battery charger from Battery e Ifthe Battery is out of the vehicle o Switch OFF and Remove the AC Power Socket from the outlet o Remove the Black lead and then the Red lead o Check electrolyte levels if possible As they may need topping up with distilled water after charging e Ifthe Battery is in the vehicle o Switch OFF and Remove the AC Power Socket from the outlet o Remove the lead from the vehicle chassis o Remove the lead from the battery o Check electrolyte levels if possible LED STATUS INIDICATOR TABLE As they may need topping up with distilled water after charging Power Charging Full Fault Red Yellow Green Red A C Power connected battery disconnected Bulk Charging Level 1 Charging Level 2 3 Charging Battery Reverse polarity connection A C Power OFF CHARGING CURVE VOLTAGE VOLTAGE TENSION V TROUBLE SHOOTING Problems Charger does not No Indicator No AC power Check AC connections and make work lights on sure Power Point is switched ON Output is short circuited Check DC connection between
2. Charger has Fault LED Reverse polarity connection to charger and battery and make sure no DC output is On Battery they are not short circuiting Check that the crocodile clips haven t fallen off the battery Check that the crocodile clips ring terminals are connected to the correct polarity Battery is severely sulphated Check the Battery condition age No Charging Fault LED Battery has a damaged cell etc Current is ON Overheat protection mode Battery may need replacement Move battery amp Charger to cooler environment Long charging Battery capacity too large Check the charger specification time Full light Fault LED Battery is defective matches the battery capacity does not come is ON Battery cannot be charged and on must be replaced MAINTENANCE e The charger is maintenance free If the power cord is damaged the charger must be left to the reseller for maintenance The case should be cleaned occasionally The charger should be disconnected from the power while cleaning
3. EBS BA10 BATTERY CHARGER For lead ac d batteries BATTERY CHARGER User Manual and Guide to professional battery charging for Starter and Deep Cycle batteries THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR 6V 12V BATTERY CHARGER BA10 ENGLISH IMPORTANT SAFETY INSTRUCTIONS Please read this manual and follow the instructions carefully before using the charger WARNING The charger is designed to charge 6V amp 12V lead acid batteries from 2Ah to 40Ah However charger can maintain batteries up to 60Ah We always recommend that you check the Battery Manufacturers specifications before using this charger Explosive gases may escape from the battery during charging Provide ventilation to prevent flames and sparks For indoor use Do not expose charger to rain snow or liquids For charging lead acid batteries ONLY of the size amp voltage indicated in the specifications table Battery acid is corrosive Rinse immediately with water if acid comes into contact with skin or eyes The charger should be used on a flat surface Never charge a frozen battery Never charge a damaged battery Never place the charger on the battery while charging Be extra cautious to reduce risk of dropping a metal tool onto battery It might spark or short circuit battery or other electrical part that may cause explosion When working with a lead acid battery remove personal metal items s
4. necting the Battery charger to your Battery If the Battery is out of the vehicle o Connect the Red lead from the charger to the positive battery terminal o Connect the Black lead from the charger to the negative battery terminal 1 DOWNS RED BLACK vou ic gt a If the Battery is still in the vehicle determine if the vehicle is positively or negatively earthed o If Negatively Earthed Most Common FIRST Connect the Red battery charger lead to the positive Battery post and then connect the Black battery charger lead to the vehicle s chassis and away from the fuel line oun ss RED BLACK CONNECTION IN VEHICLE NEGATIVELY EARTHED o If Positively Earthed FIRST Connect the Black battery charger lead to the Negative battery post and then connect the Red battery charger lead to the Vehicle s chassis and far away from the fuel line CONNECTION IN VEHICLE POSITIVELY EARTHED STEP 3 Connect the battery charger to Mains Power 240Vac e Connect the battery charger to a 240VAC Mains Powered socket e Turn on the 240VAC Mains Power e The Charger will automatically start when AC power is connected and switched on Note If the Fault Indicator LED illuminates Red please check your connections as it s likely that the Positive and Negative Leads are reversed Refer to Trouble Shooting Page for further information THE CHARGING PROCESS The charging stages are as follows
5. rger BATTERY TYPES amp CAPACITY e Suits all Lead Acid Type Batteries Conventional AGM amp Gel e Selectable 6 Volt amp 12 Volt Output e Battery Capacity o The following maximum AH capacities are to be used as a general guide only some batteries maybe able to handle a higher Charge Current Check with the battery Manufacturer when charging batteries with small capacity Battery Capacity Charging 2 40AH Battery Capacity Maintaining 2 60 AH ELECTRICAL PARTS Delivered with e Input Connector o 6 feet with 2PIN plug e Output Cord o 4 feet with Quick Connector e Extend Cord o 2 feet with Crocodile Clips Ring Terminals ENVIRONMENTAL CHARACTERISTICS e Operating Temperature 0 to 45 C e Storage Temperature 25 to 85 C e Operating Humidity Range 0 to 90 RH e Cooling Passive Natural TECHNICAL SPECIFICATIONS BAIO TOO AUTOMATIC e Input Voltage Range 100 240V Input Frequency 5 0 60Hz 6 amp 12 VOLT 1 oD0MA 1A 6 12V Size L W H in mm 100 65 36 ET bet wie Approvals CE UL cUL Mzs As CHARGING INSTRUCTIONS STEP 1 Pre Charge Check amp Electrolyte Level Check e Check the Battery Electrolyte level Not required on sealed amp Maintenance Free Batteries If necessary remove the vent caps and add distilled water so the levels are halfway between the upper and lower fill lines e Check the Voltage Output Switch on the charger and make sure it s on the correct voltage STEP 2 Con
6. uch as rings bracelets necklaces watches NEVER smoke or allow a spark or flame in vicinity of battery or engine Do not charge non rechargeable batteries In order to reduce risk of electric shock unplug charger from AC outlet before doing any maintenance or cleaning Turn off controls will reduce risk The kit is not supposed to be used by children or by people who are not able to understand the manual unless they are supervised by a responsible person who ensures the proper use of the kit MAIN FEATURES Automatic Switching Mode Battery Charger amp Maintainer Easy to Use The Battery Charger is easy to operate and requires no technical experience Charge amp Maintain Automatic Charge On power up the charger will automatically go to charging system then could be left unattended and never overcharge your batteries Charge amp Maintain Automatic Maintenance When the battery is charged to full state the charger automatically switches to maintain the battery It will monitor the battery voltage and continue to peak performance to the battery e Voltage Output Select Switch Select 6V or 12V output e Short circuit protection The charger will automatically turn off when the output short circuit occurred and prevent any damage e Reverse polarity protection The charger can automatically shut off when the output polarity is reversed and without damage SAFETY amp TEMPERATURE FEATURES e Never overcharge your batter
7. y e Output short circuit protection e Output overload protection The charger employs the use of a Solid State Circuit Interrupter that opens under severe overload This condition may occur if attempting to charge any severely discharged or heavily sulfated battery Once the Interrupter opens the charger will stop charging for a short period and then resume charging automatically and the yellow L E D will be OFF until resume charging Overloading could be due to an external load remove the load condition prior to attempting to recharge the battery e Reserve Battery Overload Condition The charger has reverse battery and short circuit protection If a reverse battery condition exists White L E D will turn RED only while output leads are connected backwards simply unplug charger from AC power and properly remake the connections as described in this manual e Internal over heat protection BS Chargers have an internal overheat protection The power will be reduced of the ambient temperature is raised e Corrosion resistant output connectors e Output clips and ring terminals provided It comes with a quick connect fly lead and 2 different kinds of connectors crocodile clips and a ring terminals The ring terminals are perfect for permanent connection to your battery You can connect the lead to the battery and tuck the lead away while you are using your vehicle and when you get back to your garage simply plug the lead back into the cha