USER MANUAL
Contents
1. USER MANUAL SATEL i LINK I O converter Version 1 4 SATEL i LINK User Manual Version 1 4 TABLE OF CONTENTS TABEEOFEONTENTS susi nee ee tl iia en aan 2 IMPORTANT NOTICE ee ac 3 PRODUC BiG IN FOR IW Es dali 4 WARRANTY AND SAFETY INSTRUCTIONS ccc cc cc cece nooo 5 BEA ee ees ke cee nae nde er tate an eae en ese oe ae 6 1 1 SATEL LINK PULSE COUNTER AND I O CONVERTER cccceeeccceeeeccceeecceeeues 6 2 SPECIFICATIONS sense dit 3 FUNCION S it eee ae a de lea idas 8 SCREW CONNECTOR FUNCTIONS ausser ee een ee ee 8 Sxl SUPPLY VOLTAGE 230 VDC rales av 8 3 2 AARM OUMU ALF OUT nee een ea 8 y ROUT eke ek ee ees a ae RA a AE AN 8 3 4 DIGITAL INPUTS 11 12 AND OUTPUTS Ol O2 cc cc ccc cecccccccccceccuccuceecencs 8 ES A ee ee ee E ee ene re 8 3 8 INDICATOR A O ele MCE Ore a Mo Rar ne e OE tr 8 SE DIP SWTITHCES Seren ee nee EN ee 9 SST DF SOS IS E er ee 9 BLD Address SsBlE 0 TIN A NA A iaa 9 A Chohh amp el sele On TA a ee onda ds 9 4 OPERATION acens 11 Au POINT TOS PONE nee ee ER 11 Al OA LINI AMOS SOO CS Unido 1 BAZ sSIOM Or ae FON 0 OPONE aida ig 2 2 BOINETOZMUEHPOINT reed e co a 11 AD MOTORS IOI ON OSO atari i FACTORY SEELEN SS seen ee a ae e boat Gud 12 CONNECTION EXAMPLES cc cc cece cccccuccccucucucuccucucucueeucneucnceeenenenens 13 Z ACCESSORIES ee a na EE 14 SATEL i LINK User Manual Version 1 4 IMPORTANT NOTICE All rights to this manual are owned solely by SA
2. 2 3 4 5 ADDRESS Used in Point to Multipoint operation to set channel for the sub station Maximum number of addresses is 15 3 7 2 Address selection table DIP2345 DIP2345 0 0 0 O reserved for the Main Station 1000 address 1 0 10 0 address 2 1 1 0 0 address 3 00 1 0 address 4 10 1 O address 5 O 1 1 O address 6 1 1 1 O address 7 000 1 address 8 100 1 address 9 0 10 1 address10 1 10 l address 11 0 0 1 I address 12 10 1 1 address 13 O 1 1 1 address 14 1 1 1 T address 15 Point to Point operation mode 2 3 4 5 CHANNEL Used in Point to Point operation to select change the operational channel When the power is turned ON the i LINK reads the channel information from the DIP switches Default mode setting is 0 0 0 0 1 up O down The channel can be changed by turning first the power OFF and then by setting the DIP switches channel selector to selected channel position for example 1 0 0 0 3 7 3 Channel selection table DIPZ 345 0000 disable channel selection is not in use 000 1 ch 1 00 1 0 ch 2 001 1 ch3 0100 ch 4 OTO Eee 0O 1 1 0 ch 6 OL T een 100 0 ch 8 100 7 ch9 1070 ch10 SATEL i LINK User Manual Version 1 4 NOTEI Check that both i LINKs are set to the same channel before turning the power ON New channel is activated when the power is turned ON NOTE2 The i LINK unit will not operate with these settings 1011 1100 1101 1110 or 1111 The power ON indicator starts to bli
3. OUT goes to VDC Driving current is max 30 mA 3 3 OUT o OUT is internally connected to VDC through an automatic fuse The supply voltage for other devices o Connections can be taken from the OUT 3 4 Digital Inputs 11 12 and Outputs O1 O2 o Inputs o 2 pcs Activated with VDC A transmission is made always when there is a change in the input P to P Minimum Voltage for 1 state triggering is 7 Vdc O Outputs o 2pcs Open relay contacts Max rating 9 30 VDC AC 1 A load 3 5 Pulse Input Can be used only in Point to Multipoint mode o For fast pulses Maximum frequency is 10 kHz 3 6 Indicators o ON o Power ON OFF Illuminated when VCD is connected Blinking it the device is not working O 01 02 PO POT o Showing the status of the input and output Illuminated when the consequently pin is activated O ALARM o Illuminated if a fail in transmission has occurred If the i LINK has not received confirmation to the sent message it will repeat the transmission Three fails in turn switches the AL OUT and the alarm LED ON O 11 12 PII PI2 o Showing the status of the Input Illuminated when the consequently pin is activated SATEL i LINK User Manual Version 1 4 3 7 DIP Swithces 3 7 1DIP switches 8 pcs 1 MP Protocol switch 1 M for Point to Multipoint Master Slave operation O P for Point to Point operation Point to Multipoint operation mode
4. NOR INSPECTED TO BE USED IN ANY LIFE SUPPORT RELATED DEVICE OR SYSTEM RELATED FUNCTION NOR AS A PART OF ANY OTHER CRITICAL SYSTEM AND ARE GRANTED NO FUNCTIONAL WARRANTY IF THEY ARE USED IN ANY OF THE APPLICATIONS MENTIONED SATEL i LINK User Manual Version 1 4 PRODUCT CONFORMITY SATEL i LINK Hereby SATEL Oy declares that SATEL i LINK converters are in compliance with the essential requirements and other relevant provisions of Directive 89 336 EEC Therefore the equipment is labelled with the following CE marking 05230 DECLARATION of CONFORMITY In Accordance with 89 336 EEC Directive of the European Council of 3 May 1989 on the approximation of the laws of the Member States relating of electromagnetic compatibility Doc No SATEL DC EMC 089 Manufacturer SATEL Oy Address P O Box 142 Meriniitynkatu 17 24101 Salo FINLAND Product SATEL I LINK 100 200 300 O Converters SATEL C LINK Pulse Counter SATEL i LINK O Converter and Pulse Counter Application External products for SATELLINE Radio Modems We the manufacturer of the above mentioned products hereby declare that these products conform to the requirements of the European Council directive 89 336 EEC This Declaration of Conformity is based on that the manufacturer has tested the Products according to the following standards ENV 50140 RF Immunity EN 55022 CISPR 22 RF Emission EN 61000 4 2 ESD and EN 61000 4 4 EFT Burst S
5. PC Layout of the SATELLINK PC Pro Multipoint program Satel I Link PC Pro v1 15 01 DEMO MODE File Master Config Window Help Dj al mi Time until next demo reset 58 56 Comm Port 1 Comm Port Comm Port Comm Port 4 Comm Port Comm Port 6 Comm Port 7 Comm Port coms coma MX cow MN con MX cos E come E cow E cons E 9600 19200 9600 9600 9600 9600 9600 39600 X Digital Output 1 Digital Input 1 O O Digital Output 1 Digital Input 1 O O Digital Output 1 Digital Input 1 O O Digital Output 2 Digital Input 2 O O Digital Output 2 Digital Input 2 O Digital Output 2 Digital Input 2 O Counter Input 1 Tick Counter Input 1 Tick Counter Input 1 Tick 0 0 0 Manual Update Manual Update Manual Update Manual 00 00 01 Address 1 Connection Type PORT1 Manual 00 00 01 Address 2 Connection Type PORT Manual 00 00 01 Address 3 Connection Type PORT Master address 0 A 14
6. SM Safe Mode 1 ON O OFF SATEL i LINK User Manual Version 1 4 2 SPECIFICATIONS FEATURE min max typical note Supply Voltage 9 30 Vdc Supply Voltage to i LINK regulated by the radio modem 5 3 Vdc Power consumption 0 03 0 1 VA 40 mA 12Vdc Serial Interface RS 232 15 Vdc 6 Vdc active RS 232 Response time lt 250 ms lt 300 ms 9600 bps Operational temperature EN ne CG Transfer rate 9600 bps PULSE COUNTER Inputs 1 pc max 10 kHz Minimum pulse width 5 us DIGITAL SIGNALS Inputs 2 pcs 0 35 Vdc 0 30 Vdc resistive 4 5 kQ Outputs 2 pcs INDICATORS Indicators OTHER OUTPUTS Alarm Output GENERAL Housing Connectors Size Lx W x H Weight Mounting IP Modem compatibility 0 30 V DC AC 1 A relay contacts normal open Power ON OFF Digital IN OUT Alarm Pulse IN 9 35 Vdc 30 mA Alarm supply voltage drive current 30 mA Metal plate painted 16 pins for radio modem 12 pins for other connections 123 x 85 x 30 mm 80 g Wall plate IP 20 SATELLINE 1870 1870E 1915 SATEL i LINK User Manual Version 1 4 Screw connector functions 3 1 Supply Voltage 9 30 Vdc o The minus contacts are in parallel One is for the i LINK and another can be used for external devices and connections Plus is for supply voltage 3 2 Alarm output AL OUT o The AL OUT is activated when three transmission fails has occurred one after another When activated the AL
7. TEL OY later called also SATEL All rights reserved The copying of this manual without the written permission from the owner of the rights by printing copying recording or by any other means or the full or partial translation of the manual to any other language including all programming languages using any electrical mechanical magnetic optical manual or other methods or devices is forbidden SATEL reserves the right to change the technical specifications or functions of its products or to discontinue the manufacture of any of its products or to discontinue the support of any of its products without any written announcement and urges its customers to ensure that the information at their disposal is valid SATEL software and programs are delivered as is The manufacturer does not grant any kind of warranty including guarantees on saleability and guarantees pertaining to applicability to a certain application Under no circumstances is the manufacturer or the developer of a program responsible for any possible damages caused by the use of a program The names of the programs as well as all copyrights relating to the programs are the sole property of SATEL Any transfer licensing to a third party leasing renting transportation copying editing translating modifying into another programming language or reverse engineering for any intent is forbidden without the written consent of SATEL SATEL PRODUCTS HAVE NOT BEEN DESIGNED INTENDED
8. The inputs of the unit are transmitted as outputs of the other unit In Multipoint mode the main station controls the sub stations 4 1 Point to Point Point to Point operation is between two units The inputs of the unit are transmitted as outputs of the other unit 4 1 1 Updating Digital messages Digital information relay switch etc will be sent to the other unit always when there is a change at the input 4 1 2Start of the Point to Point operation o Connect radio modem to i LINK directly to its connector and check that it is locked o The MP switch must be 0 in the P to P position o Before connecting the device to a power supply connect first all inputs and outputs that are to be used o When both units have these basic settings the supply voltage can be connected o Check that the channel switches 2 3 4 5 0000 unless they are gt purposely selected for a specific channel for example 2 3 4 5 0101 channel 5 see chapter 3 7 channel selection table 4 2 Point to Multipoint In this mode the program at the main station controls the units of the sub stations The main station can drive one or more sub stations maximum 15 pcs system 4 2 1 Start of the Multipoint operation O Connect one SATELLINE radio modem to the COM Port of the PC Connect the i LINK slave s to the radio modems The MP switch must be 1 in the P to MP position Before connecting the device
9. alo on the 9 of August 2010 va Aur CEO SATEL Oy aay PO Box 142 Fl 24101 SALO FINLAND EN Street Meriniitynkatu 17 Fl 24100 SALO FINLAND Ss Tel 358 2 777 7800 Fax 358 2 777 7810 E mail info satel com www satel com WIRELESS WORLD LOCAL SOLUTION SATEL i LINK User Manual Version 1 4 WARRANTY AND SAFETY INSTRUCTIONS Read these safety instructions carefully before using the product Warranty will be void if the product is used in any way which is in contradiction with the instructions given in this manual or if the housing of the radio modem has been opened or tampered with The radio modem is to be used only on frequencies allocated by local authorities and without exceeding the given maximum allowed output power ratings SATEL is not responsible if any products manufactured by it are used in unlawful ways The devices mentioned in this manual are to be used only according to the instructions described in this manual Faultless and safe operation of the devices can be guaranteed only if the transport storage operation and handling of the devices are appropriate This also applies to the maintenance of the products To prevent damage both the radio modem and any terminal devices must always be switched OFF before connecting or disconnecting the serial connection cable It should be ascertained that different devices used have the same ground potential Before connecting any power cables the output vol
10. nk in case any of these settings has been chosen ADDRESS CHANNEL DE SM 7 DE Delayed alarm o Immediate Delayed Alarm In case of a failure in the transmission the alarm output response can be selected from immediate alarm to 10 seconds delayed alarm 8 SM Safe Mode o Unchanged output state Safe Mode state In case a failure in transmission the outputs can be set to remain their status unchanged or change to Sate Mode which will switch all outputs to OFF position Safe Mode timing follows the setting of the switch 7 DE so it can be immediate or delayed by 10 seconds Selection table of the Dip switches 7 and 8 7DE 8SM O Immediate Alarm No Safe Mode I Immediate Alarm Immediate Safe Mode O Alarm delayed by 10 seconds No Sate Mode I Alarm delayed by 10 seconds Safe Mode delayed by 10 seconds 6 Selecting of the transmission standard According to the European standard for free channel operation the ratio of the transmission cycle must not be more than 10 90 This is active when the DIP switch number 6 is O In position 1 the cycle is faster Selection table of the DIP switch number 6 O one transmission cycle per second 3 transmission cycles per second SATEL i LINK User Manual Version 1 4 4 OPERATION The Operation mode is selected using the PRTCL switch The operations are Point to Point or Point to Multipoint In Point to Point operation mode the system consists of one pair of units
11. tage of the power supply should be checked Salo Finland 2012 SATEL i LINK User Manual Version 1 4 1 1 SATEL i LINK Pulse Counter and I O converter The SATEL i LINK is a Point to Point or Point to Multipoint transparent I O converter with a pulse counter input The device works together with SATELLINE 1870 1870E and 1915 radio modems In Point to Point transmission the digital status information can be sent through the radio modem to output in the other end In Point to Multipoint mode it is also possible to read information from pulse transponders Point to Multipoint transmission is possible adopting software suitable for the SATEL i LINK Screw connectors from left to right minus i LINK ground 3 9 30 VDC Supply Voltage 4 OUT out for other devices 5 ALOU 7 Alarm output 6 11 12 Digital inputs 8 10 kHz Pulse Input 9 12 01 02 Digital outputs from internal SATEL evry Addres DIS RI Channel E S Indicators relay contacts ON Power ON OFF a p gt nje ALARM Failure in transmission device ON AL I 2 PI Ol O2 I 12 Digital inputs O1 O2 Digital outputs P Pulse counter input LINK DIP Switches 8 pcs IO CONVERTER 1 PRTCL Protocol O P to P 1 Point to Multipoint 2 3 4 5 P to P ADDRESS Max 15 Outputs 2 3 4 5 P to MP CHANNEL 10 channels 6 Transmission cycle O once second by European standard 1 3 times second 7 DE Alarm Delay 1 ON O OFF 8
12. to a power supply connect first all inputs and outputs that are to be used o Set individual address to all slaves As this is a master slave operation the slaves have to be addressed All slaves must have different address see chapter 3 7 address selection table e Start using the system by the master by opening the controlling program for example SATELLINK PC Pro etc e With the program it is possible to turn ON OFF the outputs and monitor the inputs O OQ Please contact local SATEL distributor or visit SATEL s web site in order to get information of the multipoint commands SATEL i LINK User Manual Version 1 4 5 FACTORY SETTINGS The i LINK I O converter is shipped with the following default settings unless specifically ordered with settings other than those listed below DE Alarm delay 0 No Delay SM Safe mode 0 No Safe Mode SATEL i LINK User Manual Version 1 4 Point to Multipoint Point to Point Opening of the Radio modem s lock pins with a screw driver SATEL Pi Address Ri Channel E DIS y O1 O02 i LINK I O CONVERTER 9 30 Tinputs Outputs AL Fini D2 P ARA IA AAA K Supply Supply Alarm Digital Pulse Digital Voltage Voltage Output Inputs Input Relay Outputs 9 30Vdc Output 13 SATEL i LINK User Manual Version 1 4 SATELLINK PC and SATELLINK PC Pro Programs that make it possible to operate a Multipoint system with a