Home
Nanoleader Pump Series NLS110P Pressure Pump Manual
Contents
1. This warranty does not extend to damage resulting from misuse neglect or abuse nor mal wear and tear or accident This warranty extends only to the original customer purchaser IN NO EVENT SHALL HARVARD APPARATUS BE LIABLE FOR INCI DENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow exclu sion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR OF ANY OTHER NATURE Some states do not allow this limitation on an implied war ranty so the above limitation may not apply to you If a defect arises within the two year warranty period promptly contact Harvard Apparatus Inc 84 October Hill Road Holliston Massachusetts 01746 1371 using our toll free number 1 800 272 2775 Goods will not be accepted for return unless an RMA returned materials authorization number has been issued by our customer service department The customer is responsible for shipping charges Please allow a reasonable period of time for completion of repairs replacement and return If the unit is replaced the replacement unit is covered only for the remainder of the original warranty period dating from the purchase of the original device This warranty gives you specific rights and you may also have other rights which vary from state to state Repair Facilities and Parts Harvard Apparatus stocks replacement and
2. your connectors and or tighten the clamp arm of the peristaltic pump PROBLEM 7he MEASURED output is abnormal even when all tubes are disconnected It is likely that liquid has entered the sensor and damaged it There may be something else seriously wrong with the circuit board www harvardapparatus com n dwnd INSS ld dOLLSIN Snileieddy pievsey 5 Harvard Apparatus NLS110P Pressure Pump Hardware Software Installation PC Install Instructions 1 Insert CD to CD DVD drive 2 The CD content should show on the display or you can run it manually by click ing on my computer then navigate the CD drive usually drive D 3 Run the application from the CD or copy the content to your PC 4 Double Click to open the folder and then open NLS110P Customer Installation gt Builds gt Build gt My Installer gt Volume gt Run Setup exe 5 The following screen will appear airig irae sme amie Nag sneer pdt rata poh os Applications that run in the background such as virus scanning _ iee might cause the installer to take longer than average to complete 6 Select destination directory then click next W Build f Directoy for Buld Ee O Directory for National Instruments products Errera Ci lt a Publication 5422 001 REV A Hardware Software Installation Cont i 7 Choose accept then click next Build License Agreement You must accept the license s displayed bel
3. Nanoleader Pump Series NLS110P Pressure Pump User s Manual NLS110P Pressure Pump MAIL 70 5000 HARVARD APPARATUS Publication 5422 001 REV A WEEE RoHS Compliance Statement EU Directives WEEE and RoHS To Our Valued Customers We are committed to being a good corporate citizen As part of that commitment we strive to maintain an environmentally conscious manufacturing operation The European Union EU has enacted two Directives the first on product recycling Waste Electrical and Electronic Equipment WEEE and the second limiting the use of certain substances Restriction on the use of Hazardous Substances RoHS Over time these Directives will be implemented in the national laws of each EU Member State Once the final national regulations have been put into place recycling will be offered for our products which are within the scope of the WEEE Directive Products falling under the scope of the WEEE Directive available for sale after August 13 2005 will be identified with a wheelie bin symbol Two Categories of products covered by the WEEE Directive are currently exempt from the RoHS Directive Category 8 medical devices with the exception of implanted or infected products and Category 9 monitoring and control instruments Most of our products fall into either Category 8 or 9 and are currently exempt from the RoHS Directive We will continue to monitor the application of the RoHS Directive to its products and
4. ON AND DO NOT DOWNLOAD AND OR USE THIS INTELLECTUAL PROPERTY Readers of this document are requested to submit to Interchangeable Virtual Instruments Inc Licensor with their comments notification of any relevant patent rights or other intellectual property rights of which they may be aware which might be infringed by any of this intellectual property software or specification the Intellectual Property as yy www harvardapparatus com Harvard Apparatus NLS110P Pressure Pump Hardware Software Installation Cont 9 Start Installation by clicking next 10 All necessary files will be installed 11 Wait for the installer to finish building Publication 5422 001 REV A Hardware Software Installation Cont TX J 13 12 After the installer has finished building click finish 13 After installing it will ask you to restart the PC restart dwnd aJnssald qOLISIN Snieseddy pienseH www harvardapparatus com Harvard Apparatus NLS110P Pressure Pump Hardware Software Installation Cont 14 After the machine restarts shut the pump off 15 Connect the USB cable as follows mini B terminal to the back of the pump and the A terminal to the USB terminal on the PC 16 Connect the power adaptor to the DC input jack on the back of the pump 17 Turn on the power switch on the back of the pump 18 The PC should recognize that there is a new hardware installed 19 Select yes this time only then click next F
5. e Plot 0 05 0 04 HARVARD APPARATUS www harvardapparatus com 2 dwnd INSS ld dOLILSIN Snieieddy puevsey Harvard Apparatus NLS110P Pressure Pump Software Hardware Operation Cont 3 Select Set Pressure tab Cf calibration is needed skip to step 5 first 4 On the PSI target choose the desired pressure for each channel E Harvard Apparatus N S140P HARVARD Calbrate 3 Calbrate 4 APPARATUS Flow Rate Caculetor Colibrebe 1 l Caibrate 2 Script Se Pressure Pressure Plot Target PSI 5 Calibration for each pump head choose the appropriate calibration ex Calibration 1 tab and enter in the calibration values provided The calibration values can be found on the back of the pump directly behind the corresponding pump head Each pump head may be recalibrated with the use of a manometer by following the Calibration Instructions document on the CD Harvard Apparatus NI S110P HARVARD sebp Seige Set fressure APPARATUS Calbrate 3 Colbrate 4 i Pressure Plot Fow Rate Calculator Calibrabe ati Calibrate 2 CALIBRATE PRESSURE CHANNEL 2 Read Path Offset 2 Read PSI Scaling 2 is integer ioo dacmal Write Path OFFset 2 Write PST Scaling 2 nteger Hion decmal See label on rear panel for calibration values for each pressure head Publication 5422 001 REV A Software Hardware Operation Cont 6 Script Files Under the Script tab you can choose
6. istics This pump is an easy to use computer con trolled dual channel non pulsatile pressure pump It has two independent channels of flow with the option of two more independent channels available on the PC software The NLS110P Pressure Pump comes standard with PC software and a 1 cc reservoir column Publication 5422 001 REV A Introduction Hardware Overview HARVARD NLS110P To Pressure Pressure Regulating Sensor Pump Heads Pump 2 Open to Atmosphere Power Switch HARVARD Power Input Jack Reservoir Head and Column FRONT BACK Power Supply Input 100 240 Vac 50 60 HZ Power Supply Input 24 Vdc 1 7A 40W www harvardapparatus com n dwnd INSS ld dOLLSIN Snleieddy pievsey 4 Harvard Apparatus NLS110P Pressure Pump Introduction NLS110P How it Works High Performance Low Flow Pressure Control Flow System Harvard Apparatus NLS110P AIR SUPPLYING PERISTALTIC PUMP Motor Drive Feedback Comp Publication 5422 001 REV A NLS110P How It Works 1 Pump generates a pressurizing flow of air 2 Pulse of air is compressible and dampened 3 Liquid reservoir is pressurized 4 Pressure sensor maintains a pulse free flow based on pressure set Syringe Reservoir Operation Getting Started Power Attachment Using the provided line cord and power supply attach the instrument to 110 VAC or 220 VAC Tubing Connections Install tubing as shown in Fig
7. n USBAPP EXE which can be found in the main folder or by navigating through the CD 26 Click on Application exe 27 The application window should appear 28 On the application exe click on the dropdown box of port required 29 You should see a list of com ports two of these com ports should have consecutive numbers 30 Select the lower numbered com port between the two consecutive ports 31 Click on the dropdown box of port2 optional 32 Select the higher numbered com port between the two consecutive ports 33 Change of attached channels to 2 Only if you are using both pump heads Publication 5422 001 REV A Software Hardware Operation 1 Click the RUN arrow on the top left of the screen underneath Edit W Harvard Apparatus N S140P File Edt Operate Tools Window Help gt Calbrate 3 Colbrote 4 Flow Rate Caculator Calibrabe 1 Calbrate 2 Setup Script Set Pressure Porti required Koonce _ of Attached Channels r rhe Port2 optional 3 cove El Minimum PST Target Part3 optional 15 000 Eco E Maximum PSI Target Afis o0 Part4 optional acom E 2 The graph on the right should show lines on the 0 amplitude after a few seconds Harvard Apparatus N S140P I Calbrate 3 Calbrate 4 Fow Rate Caculstor Caltech 1 Cotbrate 2 Senp Serine Sot Pressure Target PSI Pressure Plot 0 25 5 75 HARVARD APPARATUS Cht Target srel Charnel 4 Pressur
8. nt search will choose the driver to install Choose this option to selectthe device driverfrom alist Windows does not guarantee thatthe driver you choose will be the best match for your hardware C n o cerca 22 Click continue anyway Hardware Installation dwnd 3 INSS ld dOLLSIN Snleieddy pievsey The software you are installing for this hardware Communications Port has not passed Windows Logo testing to verify its compatibility with Windows XP i isi Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation www harvardapparatus com Harvard Apparatus NLS110P Pressure Pump Hardware Software Installation Cont Found New Hardware Wizard Please wait while the wizard installs the software JF Communications Port 2 Setting a system restore point end backing up old files in case your system needs to be restored in the future 23 When its done click finish Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for 3 Communications Port Click Finish to close the wizard 24 Repeat the found hardware installation for the second pump head 25 Ope
9. ound New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated soitware by looking on your computer onthe hardware installation CD or on the Windows Updote Web site with your permission Read our privacy policy Can Windows connectto Windows Update to search for software O Yes now and everytime connect a device OC No notthis time Click Nex to continue 20 Select install from a list or a specific location then click next Found New Hardwere Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer onthe hardware installation CD or on the Windows Updote Web site with your permission Read our privacy policy Can Windows connectto Windows Update to search for software OvYes now and everytime connecta device O Na notthis time Click Nex to continue Publication 5422 001 REV A Hardware Software Installation Cont Q5 21 Browse to the main folder that was copied from the CD or browse the CD then click next Found New Hardware Wizard Please choose your search and installation options Search tor the best driver in these locatons Use the check boxes below ta limit or expand the default search which includes local paths and removable media The best driver found will be installed _ Search removable medio floppy CD ROM Include this location in the search O Do
10. ow to proceed NATIONAL INSTRUMENTS SOFTWARE LICENSE AGREEMENT INSTALLATION NOTICE THIS IS A CONTRACT BEFORE YOU DOWNLOAD THE SOFTWARE DIOR COMPLETE THE INSTALLATION PROCESS CAREFULLY READ THIS AGREEMENT BY DOWNLOADING THE SOFTWARE AND OR CLICKING THE APPLICABLE BUTTON TO COMPLETE THE INSTALLATION PROCESS YOU CONSENT TO THE TERMS OF THIS REEMENT AND YOU AGREE TO BE BOUND BY THIS AGREEMENT IF YOU DO NOT WISH TO BECOME A PARTY TO THIS AGREEMENT AND BE BOUND BY ALL OF ITS TERMS AND CONDITIONS CLICK THE APPROPRIATE BUTTON TO CANCEL THE INSTALLATION PROCESS DO NOT INSTALL OR USE THE SOFTWARE AND RETURN THE SOFTWARE WITHIN THIRTY 30 DAYS OF RECEIPT OF THE SOFTWARE INCLUDING ALL ACCOMPANYING WRITTEN MATERIALS ALONG WITH THEIR CONTAINERS TO THE PLACE YOU OBTAINED THEM ALL RETURNS SHALL BE SUBJECT TO NI S THEN CURRENT RETURN POLICY Definitions As used in this Agreement the following terms have the following meanings a 8 Choose accept then click next dwnd INSS ld dOLLSIN Snieieddy puevsey Build License Agreement You must accept the license s displayed below to proceed LICENSE AGREEMENT BEFORE YOU CLICK ON THE ACCEPT BUTTON AT THE END OF THIS DOCUMENT CAREFULLY READ ALL THE TERMS AND CONDITIONS OF IS AGREEMENT BY CLICKING ON THE ACCEPT BUTTON YOU ARE CONSENTING TO BE BOUND BY AND ARE BECOMING A PARTY TO THIS GREEMENT IF YOU DO NOT AGREE TO ALL OF THE TERMS OF THIS GREEMENT CLICK THE DO NOT ACCEPT BUTT
11. repair parts When ordering please describe parts as completely as possible preferably using our part numbers If practi cal enclose a sample or drawing We offer a complete reconditioning service CAUTION This pump is not registered with the FDA and is not for clinical use on human patients CAUTION NOT FOR CLINICAL USE ON HUMAN PATIENTS Publication 5422 001 REV A Specifications Accuracy Reproducibility Resolution Type Pressure Flow Rate Reservoir Column Serial Port Outputs Power Voltage Range Dimensions Weight 0 05 psi 0 1 over the operating range 0 01 psi Dual channel pressure pump 15 psi to 15 psi Calibrated from experimental data Variable comes standard with 1cc USB Time ms and psi 24Vde 1 7A 40W Universal Power Supply 100 240 VAC 50 60 Hz 24 13 x 17 78 x 10 16 cm 9 5 x 7 0 x 4 0 in 15 91 kg 7 23 lb www harvardapparatus com n dwnd INSS ld dOLLSIN Snieieddy puevsey Harvard Apparatus NLS110P Pressure Pump Introduction The Nanoleader Pump Series NLS110P Pressure Pump is a revolutionary new approach to achieving a new level of pulseless precise and accurate low flow utilizing constant pressure technology This new approach results in virtually pulse less flows making experimentation like bubble formation or reproducible flows in multi channels possible This patented pressure monitoring system assures you the highest quality low flow character
12. to read a script file select a destination for the output text file and set a sampling rate An example of a script file and its corresponding output is provided on the CD HARVARD APPARATUS C ADesktop usb pressure controler usb_pressure_script2 txt www harvardapparatus com n dwnd 8JNssald dOLLSIN Snieseddy pIenieyH Software Hardware Operation Cont 20 7 Flow Rate Calculator The flow rate calculator provided in the application is designed to give you an approximation of your current flow rate By entering in the inner diameter of your tubing the length of your tubing and the viscosity of your fluid the resistance calculator will calculate your resistance Then after selecting what is at each end of your tubing you can enter in the resistance cal culated into the Hydraulic Resistance field This will calculate your approximate flow rate HARVARD APPARATUS is a A a he z sahil a ts Harvard Apparatus NLS110P Pressure Pump Actua PSIs PSI Tar 5 Channel Publication 5422 001 REV A
13. ure 1 Leave one side open and attach the output port to the provided liquid reservoir or to the input of the system to be controlled What s Included The pump comes standard with 10 feet of 1 16 OD tubing 10 feet of 1 32 OD tubing fittings and ferrules www harvardapparatus com n dwnd INSS ld dOLLSIN Snileieddy puevsey 4 Harvard Apparatus NLS110P Pressure Pump Do s and Dont s DO DO DON T DON T DON T DON T Begin with a slightly positive pressure target when connecting to an external fluid reservoir without a filter to ensure that liquid is not sucked into the sensor Press the STOP button in the application before closing the applica tion turning off power to the pump or unplugging the USB cable Allow liquid to enter the pressure sensor This will permanently damage it Turn on off any power while the air reservoir is sealed Always leave it open to air as the pump may spike and overload the sensor Attempt to apply or measure any pressures outside of 15psi Seal the other side of the peristaltic pump tubing If the system is working properly If connected to a sealed air reservoir the pump should not continue to spin The pump should reach its target pressure within seconds Publication 5422 001 REV A Troubleshooting PROBLEM The pump will not stop spinning when set to a non zero target pressure There is a leak in the air pressure chamber Tighten
14. will comply with any changes as they apply Do Not Dispose Product with Municipal Waste e Special Collection Disposal Required Table of Contents SUBJECT PAGE NO General Information Warranty and Repairs 2 Specifications ceceenceeccsceienacteccawercusdventnntcdceneawianaenias 3 INTrOQUCHONM saite sce ce ectesteseaasdanencusesecsusecssasanteuerseseesest a Hardware OVErVvVieW cccccecccececseeeaeeeeeeeeeeeeeees 5 NLS110P How it VWWOFKS oatvcasecsteehicriavdecetatandcenes 6 Operation Getting Started cssccssessssessenseees 7 IO SANG DOI US sarirani einni 8 Troubleshooting ccsccecesenseecescnsensesensensenensensenseees 9 Software Hardware Installation 00000 10 16 Software Hardware Operation css s00 17 20 www harvardapparatus com n dwnd INSS ld dOLLSIN Snileieddy pievsey Harvard Apparatus NLS110P Pressure Pump General Information Serial Numbers All inquires concerning our product should refer to the serial number of the unit Serial numbers are located on the rear of the chassis Calibrations All electrical apparatus is calibrated at rated voltage and frequency While the flow will stay calibrated the peak will vary Warranty Harvard Apparatus warranties this instrument for a period of two years from date of purchase At its option Harvard Apparatus will repair or replace the unit if it is found to be defective as to workmanship or material
Download Pdf Manuals
Related Search
Related Contents
Extensor para monitores 第7版 - So-net EGA-503 SPRAY GUN Quelques aspects de la réécriture Copyright © All rights reserved.
Failed to retrieve file