Home
Ironhorse GSD5 Series DC Drives
Contents
1. Agency Approvals UL s listed 333109 ROHS Optional Accessories Replacement Potentiometer GSDA 5K Digital Potentiometer GSDA DP Manual Reverse Switch GSDA MREV included Analog Current Input Card GSDA AI A included Analog Voltage Input Card GSDA AI V5 included For accessories details refer to the GSD Series DC Drives Accessories section Plugging is a method of rapidly changing motor direction by reversing motor armature polarity while the motor is still running Book 2 14 1 eDR 114 DC Drives 1 800 633 0405 Prices as of April 16 2014 Check Web site for most current prices GSD5 Series DC Drives GSD5 Wiring Diagrams GSD5 240 10C Basic Wiring Diagram refer to User Manual for more detailed wiring information a IR Cur al Min Max Accel Comp Lim QQQ Customer Installed Speedpot factory provided with 8 inch leads O Inhibit Pin E orange white gal OR T 2 2 oS of E W Field terminals are used for shunt wound motors only Do not connect these terminals when using permanent magnet motors field AC input motor chassis AC1 terminal is internally fused AC2 terminal is NOT internally fused armature ground Add external fuse for AC2 if it is connected to a hot AC line GSD5 240 10N4 Basic Wiring Diagram refer to User Manual for more detailed wiring information T T rs oN
2. FACTORY PREWIRING HI white WIPER red LA LO orange DPST SWITCH jill IR Cur SPEEDPOT INSIDE OF COVER Pot Lo Wiper Pot Hi Switched AC1 7 I CUSTOMER WIRING Min Max Accel Comp Lim oP l2 3 41 5 6 7 8 9410 E E 1 lt id ES S a E N lt Do not connect these terminals when using F Kk armature ac input permanent magnet motors AC1 terminal is internally fused AC2 terminal is NOT A Endplate with holes for 1 2 NPT conduit arre dl LL O a Field terminals are used for shunt wound motors only Book 2 14 1 www automationdirect com drives DC Drives DR 115 Automation Direct NES Prices as of April 16 2014 Check Web site for most current prices GSD5 Series DC Drives GSD5 Wiring Diagrams GSD5 240 10N4 A Basic Wiring Diagram refer to User Manual for more detailed wiring information BALANCE ADJUSTMENT RED LINEARITY GAIN ADJUSTMENT CURRENT SOURCE O MANUAL AC AC Lals ol kiola P GSD5 TERMINAL STRIP WHITE Na SPEEDPOT W sees RED YELLOW from P1 2 of GSD5 LO ORANGE GSD5 240 10N4 V Basic Wiring Diagram refer to User Manual for more detailed wiring information AS a _ FACTORY PREWIRING l NOTE SOME rece IR Cur PDT Switch Min Max Accel Comp Lim y en POR SEARILY
3. Prices as of April 16 2014 Check Web site for most current prices GSD5 Series DC Drives GSD5 Introduction GSD5 240 10C Motor Rating Range 120 240 VAC y 1 8 2 hp Overview lronHorse GSD5 series DC drives offer superb flexibility reliability and value A general purpose economical line of drives rated to 2 horsepower it provides the ultimate in standard features and versatility offered in open frame and NEMA 4 12 enclosed models A logical easily accessible layout simplifies installation and adjustment Clean design quality components and careful assembly are trademarks of IronHorse GSD DC drives GSD5 240 10N4 x GSD5 Series DC Drives Features Dual input voltage 120 240 VAC 50 60Hz e Adjustable horsepower settings e Barrier terminal strip e Packaged bridge supply full wave 1 speed regulation with armature voltage feedback 1 2 with tach feedback e Adjustable minimum speed e Adjustable maximum speed e Adjustable IR compensation e Adjustable linear acceleration e Adjustable current limit e Line voltage compensation e 5kQ speed potentiometer with leads knob and dial included e Power on off switch enclosed models 50 1 speed range e Overload capacity 150 for one minute Transient voltage protection Voltage following mode or DC tachometer follower by supplying ungrounded analog input signal DC tachometer feedback e Inhibit circuit permits star
4. a e e yellow brown Speedpot red white orange black black ule Jumper clip is used to select p2 O brown input voltage range When inhibit red ul installed from P4 1 to P4 2 Pin P2 CONNECTOR the range is 0 25 VDC thru Ns l l RANGE Aii 0 250 VDC When installed white l dd REE blue from P4 2 to P4 3 the range orange vello SO aN e is 0 5 VDC thru 0 25 VDC TRIMPOT BE oP1ll 2 3 4 5 6 z 8l 9 10 14 1o h ilo L 5 ob F OO 1381520 02022 lt lt a4 Ds o 0 TaD o y 3 a ee e 2 E q GSD5 240 10N4 V E a CUSTOMER WIRING on Fe a TATT INPUT IMPEDANCE analog analog 1 2MW on high scale speed To i MOtOF ac input i 150KW on low scale COMMON signa Book 2 14 1 eDR 116 DC Drives 1 800 633 0405 Prices as of April 16 2014 Check Web site for most current prices Automatia GSD5 Series DC Drives GSD5 Dimensions dimensions in mm pa GSD5 240 10C Dimensions GSD5 240 10N4 x Dimensions 5 00 rn 4X RO 11 R2 8 NJ I FEY FEY FER FREQ FRR OG L 4X RO 11 R2 8 F 5 50 7 00 9 90 159 7 E 177 9 139 7 an o a aa alla a eeeeeeeeeee 0 75 19 1 Sj SS S EU E E E eS EU EU E 1 55 39 4 im i Book 2 14 1 DC Drives eDR 117 www automationdirect com drives
5. t and stop without breaking AC lines e Remote start stop via pot circuit or inhibit circuit e Shunt field supply provided AC line fuse e Enclosed models rated NEMA 4 12 with threaded conduit holes www automationdirect com drives Automation Direct NES Accessories e Replacement speed potentiometer kit e Digital potentiometer e Manual reverse switch Analog current input card Analog voltage input card Detailed descriptions and specifications for GSD accessories are available in the GSD Series DC Drives Accessories section Typical Applications Auger feeders e Automated door actuators e Commercial cooking equipment e Commercial lift e Food production e Industrial pumping systems e Measurement instruments e Miniature lathes and mills e Packaging material handling equipment e Printing and labeling machines e Small shop machine tools e Spray print reciprocating head Book 2 14 1 eDR 113 DC Drives Prices as of April 16 2014 Check Web site for most current prices GSD5 Series DC Drives GSD5 Selection and Specifications Model GSD5 Series DC Drives Selection Specifications GSD5 240 GSD5 240 GSD5 240 GSD5 240 GSD5 240 10C 10N4 10N4 A 10N4 R 10N4 V Price 135 00 175 00 245 00 262 00 265 00 Package Configuration open frame NEMA 4 12 Power Quality Form Factor 1 4 Special Features Input Voltage 50 60Hz c
6. urrent follower 120 240 VAC 10 manual reversing voltage follower Output Voltage 0 90 180 VDC Shunt Field Voltage 100VDC O 120VAC input 200VDC O 240VAC input 1A max Motor Rating hp 1 8 1hpO 90VDC 1 4 2 hp O 180VDC Output Current continuous 150mA 10 8A DC Current Overload Capacity 150 for 60s Current Limit adjustable 1 15A DC Transient Protection Metal Oxide Varistor MOV ILR Compensation Speed Adjustment adjustable 5kQ 2W potentiometer or O0 10VDC isolated input signal Speed Range 50 1 Speed Regulation 1 of base speed 0 5 with tachometer feedback Maximum Speed adjustable from 66 to 110 of base speed Minimum Speed linear ramp 0 30 of adjustable maximum speed Acceleration linear ramp adjustable 0 5 8s Deceleration adjustable 0 06 80s dependent on acceleration time setting Dynamic Braking no Plugging Capability Electrical Connections no barrier type terminal strip 26 12 AWG External Fusing Required Bussman ABC or Littlefuse 314 series ceramic fuses or equivalent Refer to wiring diagrams for details Operating Temperature 10 to 45 C 14 to 113 F Thermal Protection current limiting Mounting Orientation can be mounted in any orientation Corrosive Gases Weight NOT compatible with any corrosive gases 16 25 0z 413g 25 90 02 723g