Home

LEAPER-8 User`s Manual

image

Contents

1. MHz Divider FI Sm y DK Drive State F py Actual PPM A a Fail 0 0 User CLoad Total a For exiting the program b Choose to be configured Bank c Call configuration screen the Bank be chosen will be configured d Configuration is complete Show the configuration of the programming result e Go back step 1 f After input key item values click this button to enter step 3 LEAPER 8 User s Manual Step3 a Project file save or exit Help Corporation y JH PhaseLink PicoPLL Development Program O Step 3 Information Vendor PhaseLink Part Number PL61 0 01 Package 2 8 x 1 6 mm Input Freq 26MHZ PPH Setting 5 Parasitic 8 Pin 1 0E PL616 61 Bank8 Voltage 3 3U Bank 6 negR 6uA Bank 6 CLK6 Divider 1 Bank 6 CLK6 Freg 26MHz Bank 6 CLK6 Drive 8mA Bank 6 P 6x 01 Code 0 66 61 66 66 63 L State Actual PPM User CLoad Input Type Fundamental Crystal Freq Read YCC Voltage 3 3v b Function Pin State High v El c EXT Clock Enable e Read Xtal Frequency f CLK 0 MHz Prog All Back To Step 1 yO Pass 0 p Fail 0 0 Total 0 b Read the target frequency to choose the high or low voltage states for c d i programmable pin External input frequency switch Read the target frequency of voltage level e Read the target frequency Display frequency after reading target frequency In the bottom of
2. cable when you choose external frequency input Please use the 10HHz working frequency otherwise the sampling would be unusual Optional LEAPER 8 User s Manual Chapter 4 Driver Installation 1 Take out the programmer from the cartoon and check if the power switch is turn off Then insert the software disk into CD ROM drive 2 Use the USB cable to connect between the PC and the programmer Std A of USB cable connect with PC and Std B connect with USB port of the main unit If use the power adaptor for constant power supply please connect with DC IN power adaptor 3 Turn on the power of the programmer The power light on the programmer should be lighted up 4 Check if the USB cable and power adaptor are connected correctly When you turn on the power of the programmer the message Found New Hardware should appear on the right bottom of your screen Await Can Windows connect to Windows Update to search for software dialog box to appear then choose the option No not this time Then click the Next as below picture Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows connect to Windows Update to search for software Yes this time only O Yes now and every time connect a device N
3. the scroll is for set the voltage of the trigger comparison level when setting target frequency The instrument has been set up the default However when you read instable h Go back to Step 1 frequency it can be adjusted the voltage of trigger comparison level for obtaining the more stable frequency g Program the target frequency LEAPER 8 User s Manual 3 Production Mode interface instruction When you click Production Mode button to enter you will need to load a file that has save on the export mode D C frrentProcess txt i tInforkkation Vendor PhaseLink Part Number PL610 01 Package 2 0 x 1 6 mm Input Type Fundamental Crystal UnProgram Input Freg 26MHz PPM Setting 5 Parasitic 0 MHz Pin 1 0E d Read PL610 01 Bank0 Voltage 3 3W BankO negR 0uA Bank0 CLKD Divider 1 Programmed Bank0 CLKD Freq 26MHz Bank0 CLKD Drive 8m4 Bank0 P 0x01 MHz Code0 00 01 00 00 03 Program f TBack To Mode Select r State Actual PPM Pass 0 0 Fail 0 0 User CLoad Total 0 Project file save or exit Show the version of the application Display hardware connection status Read the target frequency Program the target Go back to the mode of the selection dialog box To 0 0 10
4. Leaptronix LEAPER 8 User s Manual LEAPER 8 User s Manual Contents Chapter 1 CautiOn anannnnnnnnennnnennnennnnnnnnannnnnnnnunnnnnnnnere Chapter 2 Software Installation cooccooccoonnconor Chapter 3 Hardware Installation c mcconccoccoonconaros Chapter 4 Driver Installation z u220222020220o Chapter 5 Software Operation 2220220022000 LEAPER 8 User s Manual Chapter 1 Caution 1 The best resolution for this driver is 1024 768 or above The best DPI setting is normal size 96dpi Please press down the right button of mouse on the PC display then select Properties at the lowest part and select Settings page at the most right to adjust the best resolution setting Please press down the right button of mouse on the PC display then select Properties at the lowest part and select Settings page at the most right finally Press Advanced button at the low right corner Please confirm the content of DPI Setting is Normal size 96 DPI 2 We strongly recommend using the computer with internal USB port not external interface card Since some of external USB Cards may cause the using problems of instrument Chapter 2 Software Installation 1 Please install the software first and then connect the PC and the programmer After that install the driver As for the driver installation steps please see chapter 4 If your comput
5. a b Expert Mode Production Mode Cc d a Project file save only for the Expert Mode load and exit b Show the version of the application c Enter Expert Mode icon d Enter Production Mode icon LEAPER 8 User s Manual 2 Expert Mode interface instruction DO 2 0 0 0 Step1 PhaseLink PicoPLL Development Program TD orporation 4 3 Vendor PhaseLink Part Number EXA Package 2 0 x1 6 mm S Input Type Fundamental Crystal v dP finparreg de e fem Sening 5 PL610 01 Programmable Pin I State Actual PPM Pass 0 a O Fail 0 0 User CLoad Total 0 Project file save load and exit Show the version of the application Display the hardware connection status Input the target frequency The definition of PASS FAIL The default value is 5 Inside the scope of plus or minus 5 PPM belong to PASS outside the scope will be defined to FAIL f Programmable pin features h Parasitic capacitance If necessary you should have to input the target of the parasitic capacitance in order to calculate more accurately Skip to step3 Read target frequency only Go back to mode selection dialog box j After input key item values click this button to enter the step 2 LEAPER 8 User s Manual Step2 File Help EN PhaseLink PicoPLL Development Program o Step 2 nn Bank Select Dv Voltage 13 37 y negR DUA h MELKO Freq
6. er OS supports Auto Run it will start up the installation program when you insert the CD R into it Please follow the Wizard to complete programming software installation If your computer OS doesn t support Auto Run please double click the installation program named a Setup exe in the CD R then follow the Wizard to complete programming software installation LEAPER 8 User s Manual Chapter 3 Hardware Installation 1 Inspection of the Package Once you receiving the programmer please checked the contents and see if there is something missing The complete contents as following Main Unit Power Adaptor USB Cable Adaptor X If there are something missing please contact with the local vendor as soon as possible local vendor as soon as possible LEAPER 8 User s Manual 2 Adaptor Installation Adaptor installation as following 3 Hardware Installation Please refer to the below instruction to process the hardware installation 1 Power switch Please turn on after connected with 2 3 steps 2 Power Adaptor connector In the normal condition just use the USB power supply will be enough It should be not necessary to use the power adaptor However if on the power insufficient condition or need the more constant power source please check the power switch is turn off and then connect with the DC IN power adaptor 3 USB port Connect with Std B connector of USB cable 4 Ext Clock BNC port Connect with BNC
7. o not this time Click Next to continue LEAPER 8 User s Manual 5 When appear What do you want the Wizard to do dialog box please choose the option install the software automatically Recommended then click Next as below picture Found New Hardware Wizard This wizard helps you install software for USB Device If your hardware came with an installation CD gt or floppy disk insert it now What do you want the wizard to do Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue 6 If Windows shows you a warning dialog please click Continue Anyway as below picture Hardware Installation The software you are installing for this hardware OSC Programmer Default ID has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation LEAPER 8 User s Manual Chapter 5 Software Operation After finishing the installation steps we can start with the programming software 1 Mode selection and software instruction