1. Resistance 400k ANQ 2 0 4dgts AONR 10KQ 3 0 5dgts Continuity Beeper is activated when the resistance is below80 Q Rated fuse 250 Volt 800 mA 4 Functional Use Power ON OFF The Power slide switch is located on the side of Rapport337 Turn the Power slide switch on and press to start the Rappor337 To turn off the system press more than 3 sec Then POWER OFF is displayed on the main screen with a beep Release the button The power goes off A rechargeable battery should be plugged in over 8 hrs for full charge The charged battery can operate for 3 hrs or so When the battery indicator shows below recharge it for use Full charge 000 OSD Setup Screen when Power is on RAPPORT 337 PRODUCT VER 2 02 FIRMWARE VER 2 03 PROTOCOL 1 PELCO D VIDEO NTSC BATTERY gt m RAPPORT Wait When power is on the setup OSD is displayed and it enters automatically to the video test mode after 3 5 sec The initial OSD displays its RAPPORT337 version and the initial setup on the screen Product Version 2 02 Firmware Version 2 03 Initial Protocol PELCO D TV mode NTSC PAL automatic setup Battery indicator D000 RAPPORT User s name Name can be changed in Main menu Model amp software versions are subject to be changed without any further notice aD Mode Setup LCD Screen is changed in order of VIDEO 2 METER PTZ 2 UTP whenever
2. PIZADDR PROTOCOL BAUDRATE 001 PELCO D 2 4Kbps The controlling code of protocol FAR uP TELE from the key board or DVR is Mai mEt displayed on the screen NEAR DOWN WIDE h is th h HN eee ge Most important owever is that the E M 08 04 SF 3F 8B communications speed should be of FF 01 08 OO 00 00 09 one accord GPST1 SPST 1 TOUR1 SPD16 MENU When you want to know the input signal of an exterior controller you can see the input data by connecting the communications cable to the RX terminal of the Rapport 337 How To Control PTZ PTZ functions controlling Up Down Left Right etc are possible to be tested by using buttons FAR NEAR FOCUS ADJUSTING TELE WIDE ZOOM ADJUSTING and SHIFT SETUP FUNCTION SETUP of PTZ By using the SHIFT SETUP key adjust GPST SPST TOUR SPD MENU displayed on the lower part of LCD screen by pressing SET key once shortly GPST It moves the camera view to the designated preset location Setup can be from 1 up to 99 short for GO TO PRESET When the cursor runs to GPST position after pressed select the previously memorized PRESET number using number using ys when the selection is completed press key one more time it moves to the memorized location TOUR SPD MENU 4 Functional Use It memorizes PRESET Setup can range from 1 up to 99 short for SET PRESET First move the camera to the view to be designated and press key and using C s place the
3. woveRby is pressed once MODE SELECT window displays on LCD screen when angois pressed more than 3 sec Press Carey after selecting the mode you want using the shift setup key MODE SELECT TESTER DIGITAL MULTIMETER PTZ VIEW CONTROLLER INFORMATION UTP MAIN CABLE TESTER SETTING Video Tester Mode At this mode the image quality of the external input picture signal is tested or the monitor etc is tested by using the picture signal that is output from PATTERN GENERATOR mode Digital Multimeter mode At this mode voltage current amp continuity are tested PTZ Controller mode At this mode the basic movement of up down right left for PTZ is made and zooming amp manual focus are adjusted UTP Cable Tester mode UTP cable direct amp cross cable disconnection and short circuit are tested 4 Functional Use View Information mode At this mode the basic information of RAPPORT337 can be seen version battery residual communications protocol amp speed Main Setting mode At this mode the basic setup of RAPPORT337 can be changed user s name auto power off time beeper brightness contrast etc HELP fq HELP image relevant to the mode displays when the key is pressed on for more than 2 sec at each mode How to use each mode is explained at each HELP menu VIDEO TESTER Connect the output terminal of video output system to the video input BNC of RAPPORT337 Connect the vid
4. AA size alkaline battery 6EA AA size chargeable nickel hydrogen Ni MH battery 6EA Use only chargeable nickel hydrogen Ni MH batteries when charging batteries using an adapter to Rapport337 Place the CHARGE SWITCH ON position for recharging The CHARGE SWITCH is located on the upper part of battery insert Refer to the figure below The performance of batteries can be very different according to manufacturers Please use any reliable brand Do not mix batteries of different manufacturers when charging batteries Make sure not to disorient the polarization of batteries Do not short circuit or disassemble batteries Make sure to check the polarization and the voltage and current ratings before charging batteries and disconnect the charger immediately should an abnormal situation arise A Caution Charge Put the switch ON mr OFF ON only with rechargeable Ni MH battery Read the manual carefully before j charging battery CHARGE SWITCH g N 2 Introduction of Rapport3 37 FEATURES As a handy and portable device designed for testing various appliances for the image output equipments to be installed Rapport337 is an efficient tester with useful testing functions to assist the installation of CCTV UTP test communications test
5. RS 485 communications inspection etc For testing each function set up modes and capacities to be tested using the key pad located on the front part of Rapport337 Main Functions of RAPPORT337 Video tester Multimeter PTZ Controller UPT Cable tester gt The video signal and the quality of picture can be tested and brightness color and focus can also be adjusted while the image is being watched Video signal generator mode It outputs color bar Red Blue and Green screen to allow technician to inspect video monitor or DVR Support both PAL amp NTSC video signal format gt Voltage current resistance short test can be gt gt tested The basic operational test of PTZ and other tests of focus and image checkup etc that are needed for the installation of PTZ are possible It supports RS 485 422 communications mode The wiring condition disconnected shorted of UTP cable can be checked out SSNS T Standard Items Check the contents of your Rapport337 package with the standard checklist below placing them on a level place Rapport337 Main Body User s Manual Test Lead Set Red Black Adapter Rechargeable AA Size Nickel Hydrogen Ni MH Battery 6EA Necklace UTP test Terminal BNC Video Cable Car Power jack Car Power Jack Necklace Accessory S7 i No c ee saa a Rechargeable Battery BNC to BNC Cable i a 1 5V 6EA Power Adaptor SS AC100 230V input
6. and select MAIN SETTING on MODE SELECT MENU then press key ser MODE SELECT MAIN SETTING VIDEO USER NAME TESTER SLEEP TIME bi BUZZER DIGITAL 2K BRIGHT i 4 MULTIMETER hal CONTRAST mis PTZ VIEW AUDIO VOLUME MUTE CONTROLLER INFORMATION UTP MAIN CABLE TESTER SETTING SAVE EXIT SET EXIT gt OSD Select the item by pressing 4 amp keys The each setup value can be changed by pressing amp keys A user can put the name he or she wants at USER NAME by editing At SLEEP TIME power goss OFF automatically if the button is not pushed down for a fixed time GD TABLE OF CONTENTS Before Reading the User s Manual PP EE PREA E EETA 1 1 Safety Information ovssvssssssesseussesesnseusssessssonsnessessesssease 2 WARNING sssesssesssssstsssstsesscssssssscassssasssssesosssbesvastssensssbsteonsssssaseasssssssassastseess 2 2 Introduction of Rapport337 sansdiensienicnsncensemiecnn 7 Names amp Functions of Each Part eeesseessesesseersssssssssssssssssrssseeeeeee 9 3 Specifications of Rapport337 eeesssssssssssissssitsisssstssininnas 14 General Specifications swsswiencnoncnimaninumneienseenin 14 Meter Specifications eeeeeeteeeeesrtsersessreseerserssrserseesenseessertertersernett 15 4 Functional Use 17 Power ON OFF 17 OSD Setup Screen when Power is On wrrsssssssssseessssseeeeeeesssssee 17 Mode Setup vvsssssssssssssessssssssssssssssssssssseseessenssesssssssssssssseceeenssevsssnsssssesessen 18 VIDEO TESTER crvscesssatessercsesess
7. cursor at the location of SPST Then set up the address that you want to memorize by using es and then press kgy ser one more time The information of location is stored in SPST adress It operates TOUR set up at SPST and MENU Setup can be from 1 up to 99 TOUR can be designated in the MENU of PTZ Place the cursor at the location of SPD applying the procedures described above Total 16 steps from 1 to 16 of speed are available to be selected using O Place the cursor at the location of MENU applying the procedures described above The MENU of PTZ itself is available to be displayed on LCD screen using CAUTION Make sure to check for communications protocol transmission speed and ID CONTROL SETUP of PTZ PTZ ADDR is activated on the upper part on LCD screen when C key is pressed more than 3 sec and the activated menu can be changed to ROTOCOL BAUDRATE by pressing e6 keys PTZ ADDR Setup of PTZ ID The initial setup is made 001 and changing ID of PTZ is done by pressing amp EN keys The setup is available up to 255 max PTZ ADDR PROTOCOL BAUDRATE 001 PELCO D PROTOCOL Setup of PTZ PROTOCOL The initial setup made PELCO D and changing to PELCO D PELCO P and WONWOO are available in accordance with the protocol mode of PTZ It is done by pressing 7 amp Gkkeys PTZ ADDR PROTOCOL BAUDRATE PELCO D PELCO P WwoONWwoO 4 Functional Use BAUDRATE Setup of TRAN
8. 1 Safety Information AWARNING The following is important to use Rapport337 safely First of all read through the precautions for your safety before using the system Make sure to check the input and output range of voltage or current at every input and output ports of Rapport337 before connecting each of them so that the system cannot be overloaded when in use Set up the range for measuring voltage current and resistance for their known values and use the maximum range for unknown values to protect the unit from damage 1 Safety Information When the meter function is being used do not connect any device to the VIDEO IN OUT terminals at that time as the grounding could cause any damage or trouble to both of them The following operational environment should be maintained constantly for the proper use of Rapport337 Temperature 10 50T Relative humidity 30 90 Recharging voltage 12V 10 above 1A AWARNING Pay attention to the following precautions when using Rapport337 Do not use the unit in damp humidity or leaking gas environments Do not touch it with wet hands Be mindful not to shock or shake the unit while in use to avoid damage Avoid the places of strong magnetism or electric wave which would cause incorrect measuring Be careful not to expose the ports or joints to dirt or liquid Make sure to use specified replacement fu
9. DC12V 1A out RAPPORT PACKING Portable Bag Optional Items Tester Bag RAPPORT337 Co 2 Name Function Power LCD Red LED is on when the system is switched on Charge Indicating LED Data Transmitting LED Green LED is on when being charged Red LED is on when data is transmitted Data Receiving LED Red LED is on when data is received LCD TFT LCD Key Button Controlling External Devices of Rapport337 MODE Button SET Button Mode Select Video Multi Meter PTZ Control UTP Test It is used when setup is changed OSD Button It toggles OSD amp POWER on off FAR Button It adjusts PTZ focus far direction amp Video Mode Brightness NEAR Button It adjusts PTZ focus near direction amp Video Mode Brightness TELE Button It zooms PTZ zoom in amp adjusts Video Mode Contrast WIDE Button It zooms PTZ zoom out amp adjusts Video Mode Contrast Shift Setup Button It shifts up down right left for PTZ amp for menus amp others 2 Introduction of Rapport337 Name Function Key Button METER PART Resistance Button It measures resistance Voltage Button It measures voltage Setup Change Button IT changes setup of AC DC resistance continuity test Current Measuring Button 1 Current Meas
10. I MEASURING AC amp DC VOLTAGE Voltage means the difference in electrical potential between two points The polarity of AC voltage varies over time while the polarity of DC is constant over time The meter displays ac voltage values as rms root mean square readings The rms value means the equivalent dc voltage that can produce the same amount of heat in a resistance as the measured sinewave voltage ACV 0 163V DCV 12 23V Diem ac Ko voLT BEE METER DC PR VOLT BCD UN FUSED FUSI UN FUSED FUSI 500V MAX How to measure First press the voltage measuring button and then select AC or DC by pressing Hr case of DC to be measured place the red lead on point and the black lead on point each on the voltage source 4 Functional Use MEASURING AC amp DC CURRENT Current is simply defined as a flow of electrons running through a conductor To measure current you must break the circuit under test and then place the meter in series with the circuit The current measuring range of the meter is 10A max DCA 300mA METER Dc Pomel LUBY AMP EDS How to measure First turn off the power of the circuit and discharge the high voltage capacitor Fix the red lead into the terminals of mA and 10A in accordance with the value to be measured Select one of the buttons amp E when e ER are selected place the red l
11. Power S W ON Off main power supply 3 Specifications of Rapport337 General Specifications Electric Characteristic Input Voltage 12V 10 above 1A Battery Chargeable Ni MH battery 6EA AA size Built in Charger Charging Time Above 8 hrs Operation time More than 3 hrs TV Type NTSC PAL Image level 1 Vpp 1401RE PTZ operation test Protocol Multi Protocol support Transmission speed 2400bps 38400bps Transmission mode RS 422 RS 485 UTP Cable Test Kinds of test direct cross cable and broken or short circuit can be tested Size W 88mm X L 190mm X T 58mm max 3 Specifications of Rapport337 Meter Specifications Measuring Item Measured Value Minimum Measuring Accuracy DC Voltage 400mV 100uV 0 8 2dgts 4V 1mV 4V 10mV 100mV 1 0 2dgts AC Voltage 1mV 10mV 100mV 1 2 3dgts 40H z 500H 2 DC Current 0 2UA 2uA 1 0 2dgts 20uA 200uA 2mA Measuring Measured Value Minimum Item Measuring Accuracy 400uA 0 2uV 1 5 5dgts 40Hz 500Hz 4mA 2uV 40Hz 500Hz AC Current 40mA 20uV 1 8 5dgts 40Hz 500Hz 400mA 200uV 40Hz 500Hz 3 0 4dgts oe I ee 40Hz 500Hz 400 2 0 1 1 0 4dgts 4kQ 12 40kQ 1 0 2dgts
12. SMISSION SPEED The initial setup is 2 4KBps it can be made up to 2 4Kbps 38 4Kbps It is done by pressina amp sey PTZ ADDR PROTOCOL BAUDRATE 001 aena 19 2Kbps 38 4Kbps To escape from PTZ CONTROL SETUP Mode simply press the Cser_ key again CAUTION Make sure to check for CAMERA ID PROTOCOL BAUDRATE when the test is carried PTZ operation test can not be done when the setup is different UTP CABLE TESTER Ue NO CONNECTION CABLE TEST Connect UTP cable to be tested to UTP port of RAPPORT337 while connect the other end to UTP tester The connected condition of the cable can be checked by pressing SET key after the connection is completed Direct cable and cross cable can be classified and disconnection or short circuit can be also examined ou ooo o NO CONNECTION o o START END START END CABLE TEST CABLE TEST Short circuit amp Disconnection CABLE TEST Direct cable 4 Functional Use VIEW INFORMATION Mode Setup First press wore key more than 3 sec and select VIEW INFORMATION on MODE SELECT MENU then press SET key MODE SELECT VIEW INFORMATION VIDEO SYSTEM TESTER SYSTEM NAME RAPPORT 337 PRODUCT VER 3 202 DIGITAL MULTIMETER ls eat PIZ VIEW COMMUNICATION CONTROLLER INFORMATION PROTOCOL PELCO D UTP MAIN BAUD RATE 24Kbps CABLE TESTER SETTING EXIT PRESS KEY MAIN SETTING Mode Setup First press wove J ey more than 3 sec
13. ead on mA and When if button is selected place the red lead on 10A A WARNING Check for the location of the test lead set at current test mode Place the red lead at mA only for below 400mA and place it at 10A when the value to be tested is over 400mA or the value is unknown A WARNING Use it only for the current measuring after checking for the test mode after the current mode is selected there may occur Especially damage or breakdown of the system when the burnout of fuses voltage is measured 4 Functional Use PTZ CONTROLLER How to connect each terminal and LCD screen PTZ Operation Test The basic operation of PTZ Up Down Left Right and Zoom and Manual focus controlling are possible also The test of various protocols and transmission speed are possible In order to control PTZ connect the PTZ communications cables to TX terminal of RAPPORT337 VIDEO IN PTZ ADDR PROTOCOL BAUDRATE 001 PELCO D 2 4Kbps FAR UP TELE LEFT RIGHT NEAR DOWN WIDE GPST1 SPST 1 TOUR 1 SPD16 MENU PTZ Control Setup Screen PTZ ADDR PROTOCOL BAUDRATE PTZ ADDR PROTOCOL BAUDRATE 001 PELCO D 2 4Kbps PTZ ADDR PROTOCOL PELCO D BAUDRATE 2 4Kbps 4 8Kb J 1000 GPST1 SPST 1 TOUR 1 SPD16 MENU GPST1 SPST1 TOUR 1 SPD16 MENU GPST1 SPST 1 TOUR 1 SPD16 MENU ADD Setup Screen Protocol Setup Screen Communications Speed Setup Screen TIC ae rd Key Board Control Code Screen
14. ectric shock injury or damage to RAPPORT337 cut off the power supply of the circuit and discharge all the high voltage capacity before testing resistance and continuity When applying the meter function by using your RAPPORT337 make sure to turn on its power and set up the proper mode before connecting the test lead set to the circuit to be tested 25 SETUP of KEY SELECT First press brton and then press bon to be changed to OHM BUZZ First press button and then press button to be changed to ACV DCV This button is used to test current below 4mA This button is used to test current below 400mA This button is used to test current below 10A 4 Functional Use Description of METER MODE LCD WINDOW We OHM OVER OHM OVER METER tem ea CHM RUCK WU Function Description Resistance test Continuity test Set up tests of DC AC voltage current Kinds of test to set up Q unit of resistance test is indicated Test value to Indicator of AC or DC value of voltage or current display AC voltage amp current are indicated as rms root mean square Input measured value is indicated in the form of graph Measured value 24 Graph is changed automatically equal to the graph measured value in automatic mode 25 OVER is displayed when higher value is measured than the setup value The measured value is stored and indicated here when SET key is pressed at the moment of the in hold value measured Measur
15. ed value MODE display Digital Multi Meter Mode is displayed Function Description DC DC Voltage test AC AC Voltage test Resistance test Measuring unit Q Voltage test Measuring unit V Current test Measuring unit mA A Continuity test Starting to beep at below 80 Q MEASURING RESISTANCE The unit of resistance is Q The meter sends low current into the circuit so that resistance can be measured This current runs all the paths between probes and the measured resistance value is all values added among them OHM 1 500K Die oH WT S 10A MAX UN FUSED FUSI How to measure Connect the red lead to MA and the black lead to BY as shown in the figure above at left and measure the resistance directly Se a at the resistance measuring mode by pressing ar the key pad 4 Functional Use 24 TESTING CONTINUITY Continuity means the presence of a complete path for current to flow And the continuity test features a beep that sounds when a circuit is complete The beep allows users to quickly test continuity without having to watch the display BUZZ OVER X BUZZ 0 00 DC AC OHM VOLT AMP EE DC AC OHM VOLT AMP RE Pa How to test The resistance mode returns to the continuity mode when is pressed The beeper is activated when the resistance between the red probe and black probe is below 80 Q EEE
16. eo output BNC of RAPPORT337 to the video input terminal of system VIDEO IN VIDEO OUT EE OSD Screen Setup VIDEO NTSC BIMI cil VIDEO _ Indicates that the system is in video test mode NTSC Indicates if input or output video signal system is NTSC or PAL Input video signal is output on LCD screen by automatic checking without a special setup key and output video signal system in Pattern Generator mode can be switched to NTSC or PAL using Q BOODOO Indicates screen brightness and the brightness increases gradually by 1 when key is pressed and decreases gradually by 1 when GM key is pressed And it returns to the initial setup value when one of the two keys is pressed for more than 3 sec C DOOD Indicates screen sharpness and the brightness increases gradually by 1 when key is pressed and decreases gradually by 1 when key is pressed And it returns to the initial setup value when one of the two keys is pressed for more than 3 sec 2 4 ancien ee Enter the PATTERN GENERATION MODE when key is pressed in VIDEO mode Output video system is changed to NTSC or PAL using x D or Ges Output pattern can be seen COLOR BAR RED BLUE GREEN or its reverse order using WOW O COLOR BAR RED BLUE GREEN Press key as PATTERN GENERATION MODE returns to Video MODE DIGITAL MULTI METER Voltage current resistance continuity can be tested A WARNING To prevent an el
17. nsenessseoresenssaconsstensenssnsensntenssassacenensososonenss 19 DIGITAL MULTI METER _ ssssasetserecsearscsarecsassessnaconissensgnersesscsasnssgsezeiens 22 PTZ CONTROLLER oo crrrscestossesessesetsescesseceeteseeeseeseeeeenseeasnesaeeaseeceeneeessees 29 UTP CABLE TESTER _ wrvesvesessessestesteecsesceeteseeeseceseeaenaseenseesenseeaeteeeeneees 34 VIEW INFORMATION RE E PPE PEPEE E T E AE E A E E 35 MAINSETTING sesidsssssstovbescasssnctstiscsessteeshesssepenctstitaaesstraabesaspseeaaacteeestonts 35 Distributed by Manufacturer Wonwoo Engineering Co Ltd www goodome com Made in Korea VI IEMO Before Reading the User Manual A WARNING Make sure to read through Safety Information before using Rapport337 This basic instruction manual is for users of Rapport337 Starting with the outline of Rapport337 the manual is emphasized on the explanations of its operation how to be connected to the other devices how to use every button and how to set up the system It is highly recommended for those who have handled similar devices as well as for those who are using it for the first time to read every description line by line especially cautions before using the Rapport 337 And when there is any question when in use or there is any damage make sure to contact the dealer of your Rapport337 In the 1st Chapter Safety Information warnings and precautions are explained for the safety of users when Rapport337 i
18. s in use In the 2nd Chapter Introduction of Rapport337 its features and appearance are explained In the 3rd Chapter Specifications of Rapport337 the specification of the rapport337 components are explained In the 4th Chapter Functional Use the functions of Rapport337 are explained so that the users can use it conveniently o
19. ses described in the 3rd chapter Do not disassemble the Rapport 337 Do not use the meter function when the Rapport337 or the lead set look damaged Do not measure resistance when the power is applied to a circuit When using the meter function do not forget to turn on the power of Rapport337 and set up the proper measurement mode before connecting to a circuit to be measured Turn off the power to the circuit to be measured and discharge all high voltage capacitance before starting resistance or continuity tests to avoid damage to the Rapport 337 Put the finger behind the protecting pad when using a probe 1 Safety Information A WARNING Battery Charging amp Its Precautions With the rechargeable 6 nickel hydrogen Ni MH AA size batteries placed in Rapport337 can be charged with an adopter of above DC 12V 1A and it takes more than 8 hrs for the battery to be fully charged The battery operates normally after initial 2 or 3 times of full charging and it can be used for about 3 hrs and above The battery charging can be checked on the initial picture of POWER ON and also confirmed on the VIEW INFORMATION The battery is recharged when connected to a DC adopter irrespective of the Power slide S W or button Alkaline battery AA size is usable for about 2 hrs EE E Cautions for Battery The following batteries can be used for Rapport337
20. uring Button 2 It is used for measuring lower current below 4 mA It is used for measuring current below 400 mA Current Measuring Button 3 It is used for measuring current below 10A HOLD HELP Button Measuring range can be changed and holded HELP function 8 Test Lead Connection Test Lead Positioning for Lead Connection It indicates position of Red Test Lead for measuring Voltage amp Registance via com It indicates position of Black Test Lead It indicates position of Red Test Lead for measuring Current below 400mA It indicates position of Red Test Lead for measuring Current below 10A E COMM RS 485 R5 422 Input BNC Function It inputs external image signal Output BNC It outpus input image signal to Rapport337 or internally generated Video Test Signals Communication Port It is the port of input amp output of communication signal Rx Rx Tx Tx Base It braces Rapport337 Safety hook Up It hangs on the neck for safety Safety hook Down It hangs on the neck for safety Name D m Function UTP Jack Test jack for UTP cable AUX Jack Audio AUX input port function to be added when upgraded DC Power Jack DC power input jack for over DC12V 1A