Home

VELVET Installation and User Manual May 2015

image

Contents

1. PURPLE ARROW Solutions Simplified PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual Error Codes The message toasts that show on the UI several times contain an error code if it is an error message These error codes are helpful in identifying the cause of the problem Such error codes are listed in the table below along with their respective meaning and the corresponding action Device not available Refer user 1 Checkifthe device being controlled is guide physically present and is connected 2 Contact dealer 303 Comm bus failed Refer user Contact dealer guide guide persists contact dealer guide repeated several times contact dealer guide guide PURPLE ARROW Solutions Simplified 21 21
2. PURPLE ARROW Solutions Simplified VELVET Version 11 0 Installation and User Manual May 2015 si ORC MAKE IN INDIA Purple Arrow Consultancy Services Pvt Ltd Visit us at http www purplearrow cs com Contact us at info purplearrow cs com 91 120 4315656 PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual Intended Target Audience This Installation Guide was created and designed as a resource for administrators and systems integration technicians for the configuration and deployment of the PURPLE ARROW VELVET Automation Controller from PURPLE ARROW The document provides detailed configuration best practices instruction materials for the controller and associated software While this guide may reference user interactions and functions of the Velvet Smart Client it is not intended to be a user manual User Help is part of the application PURPLE ARROW Solutions Simplified 2 21 PURPLE ARROW VELVET v11 0 az cm Specification ERE NT What s inside the eren A Typical Setup Scenario The Controller eene Harwal o s 1 2 Status Module Connection 3 Devices Connection 4 Dimmer Connection with Fan Light 5 Wi Fi Configuration and Testing 6 Router Configuration 7 R Blaster Installation 8 IR Reader Installation 9 Wireless Switch Installation 10 Wireless Dimmer Installation 11 12 Co
3. a scene until a pop up comes Click on the Schedule and then provide the type and time for the schedule AP IPIE Mi AP 24 Var Scene Scheduler Scene Name evening Interval Once Hourly Schedule Daily Cancel Schedule Weekly 12 01 Cancel OK PURPLE ARRIOW Solutions Simplified 17 21 PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual 7 Generic Remote If pre defined remotes do not meet your requirements then Generic Remote can be used It can be added to the device by choosing GENERIC REMOTE in device type To program the buttons on the remote screen click on menu and then select configure On configure screen two buttons have been provided a Record Button to record the codes of IR remote b Edit Button To edit the name of remote buttons To edit a button click on it and then enter new name for it and then press OK cR 14 24 2 35 Ov a cR lt Blu Ray Player m 8 On the first screen click on Menu and then on Eco Mode A pop up will appear where it can be set to ON or OFF PURPLE ARROW Solutions Simplified 18 21 PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual 9 Secure Mode ow For Secure Mode firstly update settings the Secure Mode configuration screen On the first screen click on Menu and then on Configu
4. able to achieve a consistent operation of two way switches the connection needs to be done in exactly the same manner as described The Status module has an RJ45 socket on board which is used to connect the CAT 6 cable with the switches on the switch board The RJ45 plug needs to be crimped to the CAT 6 cable on site using the standard straight through network wire connection CAT 6 Cable Channel protocol T 568B as shown in Fig 4 No Orange Striped 8 The numbers on the pin positions relate to the channel number on the Velvet controller Green Striped 6 Blue Now at the switch board end use the following Blue Striped table to connect the respective wire to the C terminal of the respective switch This C terminal Brown Striped 2 Brown of each switch will be connecting the device wire Table 1 plus one wire from the Status module Do not forget to paste the provided sticker listing the above table inside the switch board for future reference It is also recommended to use wire marker tags numbered 1 8 on the wires connecting to the C terminals of switches on the switch board side This will help in identifying the channel number while connecting devices 3 Devices Connection Of the three wire holes provided on the bottom of the controller Fig 5 remove one metal cap to allow for wires inside the controller From the switches on the main board bring one wire from N O terminal of each
5. device to be controlled INPUT 1 High 230VAC Low OVAC INPUT 2 High 230VAC Low OVAC PURIPLE ARRIOW Solutions Simplified PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual Software Velvet The app has been designed keeping in view the user requirement and ease of use and configuration It allows adding controllers rooms devices and configuring them very easily The interface is clean and simple and easy to operate Scenes can be added and edited whenever required M den y cR 14 24 2 44 Purple Arrow Velvet C3 Tata Sky TV Smart Controls TV mum Fan Dim Bulb y Tube Light Back Light P yily B LA La e v Curtain Window Curtain Ogeneral AC Sony Projector nv Ogeneral 13 21 A PUR PLE Solutions Simplified PURPLE ARROW VELVET v11 0 1 Installation Install the app from the apk file supplied You may need to allow Install from unknown sources 2 Adding Controller On the first screen click on Menu and go to Configuration c m CR AD EU Purple Arrow Velvet SIUE Configuration Play Scenes Door Camera Secure Mode Eco Mode Demo Mode Technical Specification Installation and User Manual BZ wl 46 CH 2 34 Purple Arrow Velvet Do you want to install this application It will get access to Allow this application to w Storage modif
6. in series with the dimmers in the same manner as normal dimmers Fig 7 10 21 Technical Specification Installation and User Manual Pin 1 of CAT 6 cable from Status Module Before connecting to the controller relay connectors please make sure the C terminals of all the switches are connected to the respective devices only and not to PHASE or NEUTRAL of 230V AC Mains power line Output of Dimmer 1 PURPLE ARROW Solutions Simplified 5 Wi Fi Configuration and Testing The controller Wi Fi has preset IP address of 192 168 1 100 and is set to join the PACS router by default The engineer should set the controller Wi Fi to join the SSID of the router to which it needs to connect and also feed in the security key using the following commands set comm open OPEN set comm close CLOS set comm remote HELLO set comm time 5 set ip protocol 2 set ip dhcp 0 set ip flags Ox6 set ip address IP ADDRESS set ip gateway ROUTER IP ADDRESS set ip netmask NETWORK SUBNET MASK set ip host ROUTER IP ADDRESS set wlan phrase ROUTER SECURITY KEY set wlan ssid ROUTER SSID gt set wlan join ROUTER SSID SERIAL NUMBER set ip localport 9000 set ip remote 9000 save Save user reboot Router Configuration The Velvet automation controller talks to the Android device on port 9000 The router must be configured with port triggering on port 9000 for TCP data traffic Set the start a
7. switch to the controller and terminate on to the device connectors numbered 1 8 bring another wire from N C terminal of each switch to the controller and terminate on to the remaining device connectors numbered 1 8 3 wire holes covered with metal caps Fig 5 Purple Arrow Consultancy Services Pvt Ltd Visit us at http www purplearrow cs com Contact us at info purplearrow cs com 91 120 4315656 PURPLE ARROW VELVET v11 0 For example if you want to connect the CFL in your bedroom to Channel 1 of the Velvet controller then as shown in Fig 6 take a wire length and a on the switch board side connect one end of the wire to the N O terminal of the two way switch for tube light and b on the controller side connect the other end of the wire to the left connector of two connectors marked as 1 on the controller Next take another wire length and c on the switch board side connect one end of the wire to the N C terminal of the two way switch for tube light and d on the controller side connect the other end of the wire to the right connector of two connectors marked as 1 on the controller 4 Dimmer Connection with Fan Light The dual dimmer module inside the Velvet controller has two independent dimmers which can be used to dim AC fans with operating wattage of not more than 250 Watts It can also be used to dim incandescent filament bulbs up to the same power rating The devices need to be connected
8. ARROW VELVET v11 0 Technical Specification Installation and User Manual A Typical Setup Scenario IR READER NENNEN CONNECTOR BOARD CONTROLLER BOARD RELAY BOARD Wireless Dimmer Wireless Switch PURPLE ARROW Solutions Simplified 6 21 PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual Hardware The Controller IR OUT CONNECTOR IR IN CONNECTOR RS485 CONNECTOR WI FI ANTENNA ON OFF SWITCH INPUT CONNECTORS p DIMMER CONNECTORS DEVICE CONNECTORS DIMMER MODULE 1 DIMMER MODULE 2 m STATUS MODULE Fig 2 Connect the N and L connector terminals to the Neutral and Live connections respectively of MAINS 230VAC to power up the controller The polarity of Mains connections should be carefully checked and connected exactly as instructed Reverse polarity may cause a short circuit in the Mains power line m PURPLE ARROW Solutions Simplified 7 21 PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual 1 Velvet Automation Controller Installation Mount the controller near the main switch board of the room with the help of supplied SCrews Fig 3 Screw Hole Dimensions PURPLE ARROW Solutions Simplified 8 21 2 Status Module Connection The Status module is an integral part of this system which helps us get present state of devices on the Android GUI To be
9. ation and User Manual 4 Adding Device E wm Ok 14 24 419 Under the room just configured click ADD User Friendly Name DEVICE and in the pop up window type in the UserFriendly Name Device Name as desired and select the Controller DeviceName Board Lights Controller Controller1 Then select the Device Type and Pin No The pins already used do not show in the list Then click on Device Type WIRED_DIMMER ADD Device Pin No DIMMER 1 Cancel ADD Device Flights Light s Ligt s B rog mg K z x c v b nm 7123 Q O m 5 Adding Scene On the first screen click on Menu and go to Play Scenes On the Smart Scenes screen click on Menu and go to Configure Click on ADD SCENE and type in a desired Scene Name and click on ADD Scene to exit lt um cR AP EL Purple Arrow Velvet 5 Configuration User Friendly Name Scene Name PRESENTATION MODE Play Scenes Door Camera Cancel ADD Scene Secure Mode Eco Mode Demo Mode MODEL MADE MODERN U QWERTYUIOP ZXCVBNM 13 Q V O ARROW Solutions Simplified PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual Next you can add devices with their desired status to the scenes User Friendly Name Room Name BOARDROOM Device Name Board Lights Status 100 Cancel ADD Device 6 Scene Scheduling To schedule a scene long touch
10. dimmer 9 Wireless Switch Module Remotely located electrical devices can be turned ON OFF using wireless switch module 10 Wireless Switch Heavy Load Module Remotely located heavy load electrical devices such as geyser AC etc can be turned ON OFF using wireless switch module 11 Customizable Scenes Scenes can be configured for easy one touch calling of a series of events 12 Scene Scheduling Scenes can be scheduled for unattended run at a scheduled time 13 Web TV Integrated UI for internet TV 14 Web Radio Integrated UI for internet radio 15 Room Creation Rooms can be created and named to resemble your own home setup 16 Sensor integration Specification 1 Controller Connectivity S ooo Ro AIR Blaster 11 Sensor O S Devices Roo o 146 O 230V AC Activated Mountins 7 5 cm x 30 0 cm x 36 5 cm 5 2 kg 1 Range upto 25 feet 1 2 Software Android 3 1 or higher User Configurable Unlimited number of scenes Modular PURPLE ARROW Solutions Simplified 4 21 PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual What s inside the Box 1 Velvet Automation Controller 2 Wi Fi Antenna Optional IR Blaster adi s IR Reader Wireless Switch Optional Wireless Dimmer Optional Wireless Switch Heavy Load Optional oa ww um IR IR Module Optional PURPLE ARROW Solutions Simplified 5 21 F PURPLE
11. gnals from the remote easily e g in a bedroom the Velvet IR Reader should be mounted opposite to the bed and also opposite to the entrance gate of the bedroom Wireless Switch Installation The Velvet Wireless Switch has been designed for plug n play use It can be used to switch ON OFF any electrical device which is connected to a separate switchboard so that extension of wire from remote switchboard to the main switchboard can be avoided It can also be used to control more devices if all relay connections in the Velvet Automation Controller are consumed For hidden installations a female socket can be used to power up the device Each Wireless Switch module is supplied with an ID printed on the back of it This ID is required at the time of configuration of Velvet Android application 10 Wireless Dimmer Installation 11 12 12 21 The Velvet Wireless Dimmer can be used to control dimming of incandescent lamps filament bulbs CFL lights fans etc Each Wireless Dimmer module is supplied with an ID printed on the back of it This ID is required at the time of configuration of Velvet Android application IR IR Configuration Installation and Testing Connecting Inputs The Velvet Automation Controller is capable of connecting to two sensor inputs These inputs can be used to trigger alarms video scenes etc These inputs are 230V AC inputs and can be connected to the output of most sensors that provide direct output to the
12. nd end ports on both triggering and opening port ranges at 9000 and the protocol to TCP Save configuration and reboot IR Blaster Installation The Infra Red Blaster can be used to send IR commands to the Velvet IR Relay Velvet IR Dimmer Velvet IR IR module and other IR controlled appliances It is capable of covering a distance of 15 20 meters in ideal conditions and has angled emitters for multi dimensional throw so as to leave no uncovered area in the room It should be strategically mounted on the top corner of the room which is on the opposite side of TV or other IR controlled devices appliances It can be pasted on to the corner walls with the already pasted double side foam tapes It is advised to test the working of all IR devices through Velvet IR Blaster for proper reach of infra red rays to the devices before pasting it on to the corner walls Removing the pasted Velvet IR Blaster may damage the wall decor Purple Arrow Consultancy Services Pvt Ltd Visit us at http www purplearrow cs com Contact us at info purplearrow cs com 91 120 4315656 PURPLE ARROW VELVET v11 0 Technical Specification 8 9 Installation and User Manual IR Reader Installation It can be used to program the controller using IR remote of IR appliances devices like TV AC set top box music system X Box etc For installations with Velvet IR Remote the IR Reader should also be located strategically so as to be able to catch IR si
13. nnecting Inputs Telus cd NN Jii DV Error COD ORT 1 2 Adding Controller 3 4 Adding Device 5 6 Scene Scheduling 7 Generic Remote 8 9 10 Camera Setting 3 21 Table of Contents Velvet Automation Controller Installation IR IR Configuration Installation and Testing Installation Adding Adding Eco Secure Mode Technical Specification Installation and User Manual CURIAE ARRIOW Solutions Simplified PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual Features 1 Home Office Wi Fi Integration Can be integrated with existing Wi Fi network at your home or office 2 Light Fan Control Virtually any electrical device can be switched ON OFF 3 Dimmer Control Linear dimming control for fans and incandescent lamps 4 Video Door Bell Door IP camera can be integrated to view the visitor upon push of the door bell 5 Door Latch Control Electric door locks can be operated 6 Curtain Control Motorised curtains can be controlled 7 Wireless appliance control Infra red based wireless electronic electrical appliances equipments can be integrated 8 Wireless Dimmer Module Remotely located dimmable devices can be controlled using wireless
14. ration In the Configuration screen click on Menu again and go to Secure Mode Setting and then update the settings On the first screen click on Menu and then on Secure Mode A pop up will appear where it can be set ON or OFF 10 Camera Setting To be able to view the door camera you need to configure the camera on Velvet as shown below Purple Arrow Velvet Enter Camera IP Address Camera IP Address Enter Camera Port No User Friendly Name Camera Port No Device Type Enter Camera Username Camera Username Camera Name Room Camera Camera IP 192 168 1 34 Enter Camera Password Camera Password Camera Port Username Enter Camera Url Camera Url Password Url tsp 192 168 1 34 80 Enter Controller IP Address DE 264 Controller IP Address ADD Device Enter Controller Pin No Controller Pin No Enter Door Latch Timeout Door Latch Timeout in seconds Note that the camera configuration settings differ from manufacturer to manufacturer To get the correct settings please contact the Velvet support team CURIAE ARRIOW Solutions Simplified 19 21 PURPLE ARROW VELVET v11 0 11 Notification The application comes with an ongoing notification through which rooms and scenes can be accessed directly from notification area 20 21 Technical Specification Installation and User Manual Vodaforo i424 41 Im Tue Apr 21 Purple SCENES Velvet Charging 2 hrs until full
15. y delete SD card contents JY Network communication full network access JY Hardware controls record audio Show all Install CI Ch AP Secure Mode Setting Import DB File Share DB In the Configuration screen click on Menu again and go to Controller 14 21 n PURPLE ARROW Solutions Simplified PURPLE ARROW VELVET v11 0 Technical Specification Installation and User Manual In the pop up window type in the Controller Name as desired and enter the Local IP Address of this controller as set at the time of Wi Fi configuration If there is any Static IP associated with the controller then enter it otherwise enter the Local IP again Then enter name of the Wi Fi network to which the Controller Name Controller1 controller is connected After that select the Local IP 192 168 1 8 9000 Il controller type Finally specify whether the controller NetworkName WifrNetwork supports Eco Mode or not and then click on ADD Controller Type 8R 16IR Controller Support Eco Mode YES Cancel ADD Controller 3 Adding Room Click on ADD ROOM and type in a desired room name and click on ADD Room User Friendly Name Room Name BOARDROOM Cancel ADD Room BOAR O0MS BOARD ROOM BOARD OMS U QWERTYUIOP Mane OR 8 ZX CV BNM amp 723 Q iem PURPLE 15 21 ARROW Solutions Simplified PURPLE ARROW VELVET v11 0 Technical Specification Install

Download Pdf Manuals

image

Related Search

Related Contents

Bulletin 34P03A11-01  NRS 1-54 NRS 1-55  組込みソフトウエア技術者育成  Foxit Reader 4.2 User Manual  Istruzioni per l`uso  De'Longhi DEGLSC24SS User's Manual  Smeg MF9-CR faucet  Respireo Soft Baby BD FR  MS2421 / MS2422 / MS2431 Bar Code Scanner Installation and  

Copyright © All rights reserved.
Failed to retrieve file