Home

User Manual - mindwalker

image

Contents

1. im Recording Setup Save to Folder CAPe cording test Browse Save Made Manual f Auto Name W Wier me about unsaved recordings Auto Save File Marie Filename pretix samples f Numeric suffix 002 eE n caan Date Time suffix mw Classic User Guide 8 e Save to Folder Location in which to store recordings must be defined for Auto Name and Auto Save modes e Save Mode Manual Complete control over name location and when to save recording e Save Mode Auto Name File is named according to File Name settings saving is manual e Save Mode Auto Save File is always saved after STOP and named according to File Name settings e Save Mode Warn me Unless you don t care about forgetting to save recordings leave this box ticked e File Name Filename prefix This text is automatically inserted at the beginning of the filename e File Name Numeric suffix Files are named with incrementing number from 000 to 999 e File Name Date Time suffix Files are named with date and start time in format yy mm dd_hr mm ss The numeric suffix system has been designed for ease of recording meter drills Many recordings can be made and easily viewed afterwards from a drop down box by right clicking the OPEN button gt ff a The drop down box will show all numeric files in a folder with the same prefix name Warning This system also makes it easy to delete all files by using t
2. amatically affect the screen appearance It is therefore important to understand how these settings are remembered By default these settings are stored in the file mw3_Classic ini located in the mindwalker directory Also by default you will be prompted to save any settings changes when exiting the program This behaviour can be changed from the Settings gt Autosave menu item Select On to always save changes select Off to always exit without saving changes or leave it as Prompt mw Classic User Guide 6 If you wish to store several different styles then use the File gt Save Settings As and the File gt Load Settings menu items The program always opens using the settings file in use when the last session was closed Basics Playback PROGRESS BAR lt gt gt E OPEN PLAY STOP PAUSE To use the playback function the View gt Recording menu option must be checked so that the Recording Panel is visible Also ensure that the Recording gt Audio gt On menu item is checked Playback is accomplished by first loading a file using the OPEN button Once loaded the total time of the recording will be shown at the left end of the panel Press PLAY to start playback and STOP to terminate it Recordings made with this version or later software will show the clock as it was at the time of recording Once playback has started the Pause Skip Forward Skip Backwards and Repeat buttons are enabled Left mouse clicking anywhere on the Progr
3. erly installed mw Classic User Guide l Basics Basics Starting the Program The program will be listed on the Start menu under mindwalker gt mw3 Classic The first time the program is run it will enter Demo mode If you have mindwalker hardware plugged into a USB port then select Connection gt Connect from the menu bar The program should find the mindwalker device and will automatically locate it the next time the program is run Basics View menu There are three main elements to the screen display a mw3 Classic Sey ee ery Meter Panel Graph Panel Recording Panel e Meter Panel with either traditional rectangular or circular style dial always visible e Graph Panel optional e Recording Playback Panel optional These main elements of the display are controlled from the View menu mw Classic User Guide 2 arapi The Graph display is made visible or hidden by selecting View gt Graph The Recording Playback panel is made visible or hidden by selecting View gt Recording It must be visible to play the demo file Select View gt Meter Style to open the meter panel display options w Meter Display Setup E mw xi mw Classic User Guide 3 Dial four types of dial display are available Traditional AutoSet a traditional analog dial is presented and the needle behaves the same way as modern automatic analog meters when the needle goes off the dia
4. ess Bar will skip playback to that time It is also possible to select a section of a recording for playback This is done by dragging the mouse from left to right along the progress bar while holding down the left button Right clicking on the bar will return to full selection Overide Option During playback the settings from the time of recording such as the Dial type and Sensitivity are duplicated They can however be changed if the Overide option 1s checked mw Classic User Guide 7 Details Recording Panel ee Sjc gt gt w e st a 4 RECORD SETTINGS SAVE MODE To use the recording function the View gt Recording menu option must be checked so that the Recording Panel is visible Audio can be turned on or off in the Recording gt Audio menu When making recordings with audio enabled the microphone setup and level are controlled by the standard Windows methods eg Windows Control Panel etc Meter data recordings are saved as mwd files and the audio is saved separately as a wav file These files must have the same name and be located in the same folder to work together If audio 1s enabled when loading a recording but no sound file 1s located then an error message will appear Note Playback will also work from a mp3 audio file so once recorded in wav format free software can be used to compress to mp3 format The SETTINGS button gear wheel opens the Recording Setup panel
5. he Reset button in the Recording Setup Filename prefix jassess_ f Numeric suffix oos Reset ere ee C DateTime suffix Suppose there was one recording in the sequence you wanted to keep Simply load it and right click on the number text above the OPEN button You can then save it as another name and then use the Reset button to delete all files in the sequence mw Classic User Guide 9 Recording Panel Keyboard Shortcuts R RECORD P PLAY PAUSE S STOP Body Motion Detect It is possible to detect needle responses caused by hand or finger motion on the electrode Such motion causes the LED to flash Blue The sensitivity of the Body Motion Detect can be changed in the Settings gt Alerts gt Body Motion Detector menu Needle Freeze Detected Body Motion can optionally cause the needle to freeze and change colour Once body motion has ceased there is a short delay before the needle returns to its normal colour and unfreezes Needle Freeze on Body Motion can be turned off or on with keyboard shortcut F or from the Settings gt Alerts gt Body Motion Freeze menu This USER Guide is work in progress and is incomplete Check the web site for updates mw Classic User Guide 10
6. l it 1s automatically SET It can also be manually SET by the keyboard space bar Traditional Continuous when the needle nears the edge of the dial a second shadow needle enters from the opposite side and then becomes the main needle Circular this display provides a theoretically better presentation of the needle since it is permanently visible with no discontinuity It may however take some time to become accustomed to this less familiar format Choose 1 or 2 needles display mw Classic User Guide 4 There are also options to change the dial scale graduation and clock display The locations of the clock and Baseline display can be swapped by ticking the On Left box in the clock section When the digital clock is displayed the date can also be shown in either short or long format These formats are configured according to the settings in the Windows Control Panel Regional Settings Using the View menu enables the user to tailor the screen to display only those elements required and in a variety of formats Remember that the meter window can be made full screen which produces a particularly clean and clear display on small screen laptop computers mw Classic User Guide 5 Basics Meter Panel The meter panel comprises the following Baseline Position top left large digital readout Status centre bottom traditional or centre left circular text describing the status or mode currently active Usually dis
7. mw3 Classic Software User Guide Issue 2 05 27 03 2015 About this User Guide This document applies to mw3 Classic Software Version 2 07 or later The software was named Classic since it has the option of displaying the meter dial in the traditional classic rectangular style of an analog meters Earlier software simply had the circular dial The first section of this guide Basics gives a simple overview of the software which will enable the user to get up and running quickly The next section covers topics in more detail Needle Test The most critical aspect of a computer based meter is the smoothness of the needle motion on the screen The needle test is a quick guide to how well your computer will perform It can be turned on and off from the Connection menu ngs Connection view Graph ags Connection view Graph F Connect Port Connect Port Needle Test Start Needle Test Stop The quality of motion depends mostly on the computer graphics performance Demo To run the program as a demo install the software then play the demonstration file which by default is located in the Program Files mindwalker samples folder See the section Basics Playback for instructions on how to do this Installation Follow the steps given in the separate document Software Installation Instructions If you have purchased the mindwalker hardware mw3A then you will also need to verify that the USB driver has been prop
8. plays Demo Mode Input OK Recording or Playback Sensitivity Knob bottom left this control can be adjusted by dragging the knob with the mouse or using the up amp down arrow keys on the keyboard Clock top right Can be configured View menu as hidden analog digital 12hr or digital 24hr Baseline Drop BD Counter bottom right digital readout appears faint until it is enabled by clicking on it with the mouse or the keyboard shortcut C Repeating this action will toggle it Off On Clicking on it and holding down the mouse button or the keyboard shortcut Z will zero this counter The size of the panel on the screen can be adjusted by dragging the left or right window borders or full screen by the standard methods Basics Alerts The dial incorporates a simulated LED a round indicator that flashes on and whose colour indicates the status of the needle For those familiar with automatic analog meters they have such an LED to indicate a needle SET and on the traditional dial it is located in the same position On the circular dial it is located in the centre Following are the default colours for the LED and their meaning Green a needle SET has occurred Blue Body Motion has been detected Red a Real Time delay needle lag has been detected Basics Remembering Settings There are many options which control the function and display of the the program Colour settings in particular dr

Download Pdf Manuals

image

Related Search

Related Contents

U.S. CUSTOMER SERVICE: (TOLL FREE)  G4040Z - G4040IZ  日本語 - Kodak  NITE資料「製品の安全な使い方:四国支所」【PDF:2303KB】  5075 - Lega srl costruzioni apistiche  User Manual  Le guide de l`animateur scientifique - Latitude Sciences  Le Système d`Information  Bienes - Instituto Tecnológico de Sonora  Mental`idées - Ligue Bruxelloise Francophone pour la Santé Mentale  