1. turn the 1 switch 1 ID digit to 2 and turn the 2 switch 2 ID digit to 3 If daisy chaining Alarm Router units ensure that each has a unique address and that all are set to the same baud rate JTECH Communications Inc Page 9 Alarm Router User Manual 1 3 3 Connectors All the front connectors are of RJ45 type 8 pin socket Pin numbers socket view viewed from the front of the unit RS485 Connectors COM1 two connections available This port is used to connect the Alarm Router to the Master Controller as well as other Alarm Router units The two RS485 ports are internally connected in parallel to enable multiple Alarm Router units to be daisy chained together Pin No AEL Description Ea LINE RS485 A termination LINE RS485 B termination Po NCP SGND Signal Ground Transmitter Interface Connector This port is disabled on the Alarm Router Serial Port Connector COM2 This port is disabled on the Alarm Router Page 10 JTECH Communications Inc User Manual Alarm Router 1 4 Rear Panel 1 4 1 Mains Input This IEC connector is used to supply power to the unit You can plug 110 240VAC 50 60Hz into here without the need to change power supplies or settings input is auto sensed You will have been supplied with a mains lead in the Alarm Router kit which will plug straight into this connector Maina Input 110 240VAC BO 60Hz O 7A Max Aone aie DO NOT OPEN
2. 950 1 2001 We hereby declare that all essential radio test suites have been carried out and that the above named product is in compliance to all the essential requirements of Directive 1999 5 EC The conformity assessment procedure referred to in Article 10 5 and detailed in Annex IV of Directive 1999 5 EC has been followed with the involvement of the following notified body Bay Area Compliance Laboratory Corporation 1274 Anvilwood Ave Sunnyvale CA 94089 USA Identification mark 1313 Notified Body Number The technical documentation relevant to the above equipment can be made available for inspection on application to JTECH C 1313 Page 2 JTECH Communications Inc User Manual Alarm Router COMPLIANCE NOTICES con t ROHS amp WEEE To minimize the environmental impact and take more responsibility for the worl in which we live JTECH hereby confirms that the following product series comply with Directive 2002 95 EC RoHS and 2002 96 EC WEEE of the European Parliament SAA AUSTRALIA To ensure compliance with ACA Technical Standards this equipment is labeled with a Telecommunications Compliance Label For safety reasons this equipment should only be connected to compliant telecommunications equipment in accordance with the manufacturer s instructions N1137 FCC USA Part 15 This equipment has been tested and found to comply with FCC Rules and Regulations Part 15 with the limits of a Class B di
3. NI n 70S TITAN Alarm Router User Manual Manual Revision 1 01 Last updated 18 06 2009 COMMUNICATIONS INC a subsidiary of MICROS Systems Inc Alarm Router User Manual NOTICE This manual software and electronic circuitry are copyrighted All rights reserved Under the copyright laws this manual software and electronic circuitry may not be copied in whole or in part without written prior consent of JTECH Communications Inc JTECH All information provided in this document is carefully prepared and offered in good faith as a guide in the installation use and servicing of our products Installers must ensure that the final installation operates satisfactorily within the relevant regulatory requirements JTECH accepts no responsibility for incorrect installation JTECH reserves the right to change products specifications and installation data at any time without notice JTECH makes certain limited warranties with respect to defective diskettes documentation and electronic circuitry Please see the associated information contained on this page SOFTWARE LICENSE STATEMENT This manual software and electronic circuitry are protected by international copyright laws Under the copyright laws this manual software and electronic circuitry may not be copied in whole or in part without written prior consent of JTECH except in the normal use of the software to make an archival copy of the software for the sole purpose of back
4. RISK ee ie OF ELECTRIC SHOCK Alarm Input Connectors Up to 16 pairs of wires can be connected here to provide alarm inputs to the Alarm Router Dry contact version shown here a a a ce Bei en f s CRNE ERS Enas SE E E E d Tee ee ee ee ee ee M Each unit also comes supplied with four pluggable terminal blocks so that the incoming alarm wires can be securely terminated with screw connectors The Alarm Router unit is available with contact closure or an opto coupled alarm inputs e Opening or closing a circuit will activate a contact closure input Actions such as opening and closing a door may trigger contact closure alarms e Applying or removing a voltage will activate an opto coupled input Actions such as turning a light on and off may trigger opto coupled alarms JTECH Communications Inc Page 11 Alarm Router Page 12 User Manual Optically Isolated Inputs The input is electrically isolated from all other inputs as well as the microprocessor circuitry The input resistance is greater than 15K ohms due to the series input resistor Activation is by an A C or D C voltage across the input terminals with guaranteed operation of 5 Volts The maximum input voltage is 40 Volts A C or 60 Volts D C The input is bi polar in that the input is not sensitive to the input polarity Contact Closure Inputs A low resistance connection at the input terminals will result in an ac
5. d A WARNING The Alarm Router unit and the alarm wiring loom should be placed away from any transmitters to prevent interference and false alarms Use the supplied IEC mains power lead to connect 110 240VAC 50 60 Hz supply to the Alarm Router unit JTECH Communications Inc Page 13 Alarm Router User Manual 3 APPENDIX 3 1 Further Help and Support Contact your Place of Purchase A JTECH Authorized Distributor or Dealer sets up most systems Contact your place of purchase with inquiries beyond the scope of this manual This Product is Not Field Serviceable Should a fault develop with the hardware or software contact your place of purchase for the most appropriate form of action Do not attempt to open or repair any of the products as this may void any warranty 3 2 Technical Specifications Note Specifications subject to change without any notice EGUMEN DE aoaaa EA E E tanh teaot sadanvor ENT Alarm input module Alarm Capacity sssiareiosastetianesyatcncdepiiesenbosesuetie oaa 16 Alarm inputs PEE P A E T Max 39 Alarm Router per Master Controller 624 total inputs per system Power Supply sssessessssssssssssssrrrrrrrreressreesesssssrereretrrrrreesesssssseeene 110 240VAC 50 60Hz 25W max External led indicators Power PTT Data RS485 TX RS485 RX RS232 TX RS323 RX E eomaunennametaaanacntace Alarm input status providing real time physical indication External COMMECTON S svartsiecansanccasuevgucsebacteaetmosSeanete
6. gital device designed to provide reasonable protection against harmful interference This equipment generates uses and can radiate frequency energy and if not installed and used in accordance with the instructions may cause interference harmful to radio communications On the base of the equipment is a label containing an FCC Registration Number if applicable Fe IC INDUSTRY CANADA INDUSTRIE CANADA This class B digital apparatus complies with Canadian ICES 003 de Industrie Industry l Canada Canada SAFETY AND GENERAL INFORMATION Important information on safe and efficient operation Read this information before using the unit Electromagnetic Interference Compatibilit Nearly every electronic device is susceptible to electromagnetic interference EMI if inadequately shielded designed or otherwise configured for electromagnetic compatibility Potentially Explosive Atmospheres Do not operate the Alarm Router in any area with a potentially explosive atmosphere Sparks in a potentially explosive atmosphere can cause an explosion or fire resulting in bodily injury or even death Areas with potentially explosive atmospheres include fueling areas such as below decks on boats fuel or chemical transfer or storage facilities areas where the air contains chemicals or particles such as grain dust or metal powders and any other area where you would normally be advised to turn off your vehicle engine Areas with potentially explosive atmosp
7. heres are often but not always posted Blasting Caps and Areas To avoid possible interference with blasting operations do not use the Alarm Router near electrical blasting caps in a blasting area or in areas posted Turn off two way radio Obey all signs and instructions SELV warning The Alarm Router module has been assessed as SELV throughout all ports shall be connected to approved SELV circuits or an approved isolation unit shall be used JTECH Communications Inc Page 3 Alarm Router User Manual Table of Contents 1 ABOUT THE ALARM ROUTER sissincssscestasiciinsactinnnsbacncisniwsicuansanundusbudungusnue ines sectunns cnuaceumaardssueiensediuaeuienes 6 LL Modu UON T E E E E E E E 6 12 Alarm Router Kil arcean E 7 Lo PONE PAG aonn A 8 Laa LEDINCI O ree I E T A AE AE O RA 8 Lo WET EE ere E sas senesuccn autieet aancseeoeeeess 9 LIS CONS CEOS access issstroadiatsersas asananceacetvetaannannvae nde aceunwataoedabernaveuetsaadaceigecabiworedoatneuanadsenbasatecaummetaaas 10 Me REPNE A 11 LAL MAA U ena E E E AT AE A NEE E E A OTA N 11 2 INSTALLATION seesoucaseenecetusascceetccrcaceeseduccsesonssecuccouecoegasedusacaduvosspesesesesnpanacutusenaceesencauounsstesseisntacetmencs 13 DA Enclosure WIOUN CINE sericiieriisareii it rT EEEN EEN 13 3 APPEND ccna E es orapeaeunceinershavdueciousetainnvevaest 14 3 141 Further Help and SUPPO soso sie ccedscahessccdesensecterdniwcecsenntaacic tindecseuseanceesbuadecesecancedesvadse
8. ing up the software and protecting your investment from loss or damage LIMITED WARRANTY With respect to the physical documentation and physical electronic circuitry enclosed herein JTECH warrants the same to be free of defects in materials and workmanship for a period of one year from the date of purchase In the event of notification within the warranty period of defects in material or workmanship JTECH will replace the defective diskettes documentation and electronic circuitry The remedy for breach of this warranty shall be limited to replacement and shall not encompass any other damages including but not limited to loss of profit and special incidental consequential or other similar claims JTECH specifically disclaims all other warranties expressed or implied including but not limited to implied warranties of merchantability and fitness for a particular purpose with respect to defects in the documentation and electronic circuitry and the program license granted herein in particular and without limiting operation of the program license with respect to any particular application use or purpose COMPLIANCE NOTICES CE EUROPE JTECH declare under our sole responsibility that the product Alarm Router to which this declaration relates is in conformity with the following standards and or other normative documents EN 55022 1994 A1 1995 A2 1997 EN 301 489 2 v1 3 1 2002 08 EN 301 489 7 v1 3 1 2005 11 EN 60
9. ns Serial RS232 RJ45f with RS232D interface E cance sani eeuene cad ecanstieueuk eeamauaniee saan ueeaeseenaiwoecseet Serial RS485 RJ45f x 2 Slave only port ft onscreen A E E seseuccnones Pocsag RJ45f with RS232 level pocsag output selec wp tebac asnsdes A came sautosweun dans scenveensnienseudonver tones Power IEC mains socket AAE E E AE EE A T E E Alarm inputs 4 x 8way pluggable terminal block External SWitChEsS acatcasvandeessadcoctenedaenessasancuswsttuneadauetasadseusedeiencudondaseadeodeavadcaceesats Rotary switches E E E A A eee cates Switch 1 RS485 baud rate EPP E PEA ase emis O E A E E A E E E E Switch 2 amp 3 RS485 ID DIMENSIONS senssakenensa n E a Standard 19 inch rack case E E EE E 17 3 x 8 1 x 1 7 inches 439 x 205 x 44 mm without rack ears VEY E EEEE E A N ET EE E T E TE 5 9lb 2 7kg nett Ambient temperature operating range sececcee 0 50 C 20 90 RH non condensing Storage temperature FANBe ccssssecccesssecceseeeeeees 10 60 C 10 95 RH non condensing Page 14 JTECH Communications Inc
10. scieencenonse 14 32 Technical SDECITICATIONS sspsissssisisrissrsisrarais erreurs Di pr a ar EuN NT EANET AINET 14 Page 4 JTECH Communications Inc User Manual Alarm Router About This Handbook This manual is designed to assist with installation of the Alarm Router Every component of the system is described in a separate section of the manual with step by step instructions to facilitate hardware installation and software configuration Conventions ga NOTE A note preceded with this symbol indicates secondary information pertaining to the topic under discussion IMPORTANT A Right pointing arrow followed by text in this manner presents important information A WARNING Warnings like this alert you to the fact that you might damage your equipment or lose data if you don t follow instructions carefully JTECH Communications Inc Page 5 User Manual Alarm Router 1 ABOUT THE ALARM ROUTER 1 1 Introduction The TITAN Alarm Router is a sixteen 16 input either dry contact or opto coupled depending on the model device that can report alarm conditions back to the TITAN Master Controller via its RS485 connections Page 6 JTECH Communications Inc User Manual Alarm Router 1 2 Alarm Router Kit Your Alarm Router Kit will contain e Alarm Router Unit e IEC Mains power cable e Pack including 2 x rack ears 6 x black countersunk screws 4 x rubber feet e Four x 8 way pluggable terminal blocks e Communica
11. tions cables o Blue straight through cable RJ45 to RJ45 e This Alarm Router Installation Manual e CD containing manuals and configuration programs JTECH Communications Inc Page 7 Alarm Router User Manual 1 3 Front Panel STEC Transmitter RS485 RS485 RS485 POISE AT Baud Rate Unit i Power PTT Data Tx Rx Tx 0 1200 bps 1 2400 bps TX Output COM 1 COM 1 2 4800 bps 3 9600 bps ist 10 digit 2nd 1 3 1 LED Indicators Page 8 Power Indicator Power Yellow Indicates that power is applied to the back of the unit and that it is operational Transmitter Indicators This port is disabled on the Alarm Router RS485 Indicators TX Red Indicates transmit data activity on the RS485 ports RX Green Indicates receive data activity on the RS485 ports RS232 Indicators This port is disabled on the Alarm Router Alarm Input Status LED s 1 16 Green The alarm LED s show the real time physical status of the alarm inputs JTECH Communications Inc User Manual Alarm Router 1 3 2 Switch Settings e RS485 Baud rate 4 position rotary switch which selects either 1200 2400 4800 or 9600 bps Set this switch to suit the baud rate of the connected RS485 device 0 1200 bps 1 2400 bps 2 4800 bps 3 9600 bps default e RS485 Unit ID Address These 2 rotary switches set the RS485 address of the unit A range of 00 to 39 is available For example to set the unit to ID 23
12. tivated input Guaranteed operation will occur with the loop resistance being less than 1K5 ohms Maximum current flow through the loop will be approximately 6 mA At 1K5 ohm loop resistance the current will be 3 5 mA This circuit relies on isolated contact closures with no common earth between inputs JTECH Communications Inc User Manual 2 1 Alarm Router INSTALLATION By default an Alarm Router will perform alarm monitoring and notify the Master Controller of the alarm status Simply set the RS485 address and baud rate connect the external alarm points and connect to the Master Controller For further details on how to install and configure the Alarm Router and Master Controller please refer to the TITAN Master Controller User Manual Enclosure Mounting Before mounting the enclosure you will need to decide where to place the unit The Alarm Router can be desk mounted or installed into a standard 19 inch rack frame Your Alarm Router package contains four adhesive rubber feet which can be placed on the underside of the unit if you wish to desk mount it If the unit is to be rack mounted you will need to attach a pair of rack ears Your Alarm Router package contains a set of rack ears and six screws Use a phillips head screwdriver to attach the ears to the chassis Wiring from the alarm inputs to the devices to be monitored should also be done at this point Standard figure 8 or twisted pair ethernet cabling can be use