1. Q GeoVision 2 3 2 Setting Connection with GV AS Controller 1 On the Web interface of GV ASController click Extended Reader in the left menu The Extended Reader Configuration page appears Type Serial number of your fingerprint reader See 1 3 Serial Number and select Function that the fingerprint reader is used for and click Submit The red mark appears in the Setting Status filed which means the connection is not established See Figure 2 2 To access the Web interface of GV GF1911 1912 type the IP address you find on Net Module Utility on the browser You can also double click the fingerprint reader found on Net Module Utility type its default ID and Password admin and click the Advanced Setting button to access it Click SETTINGS and select GV AS Controller This page appears GeoVision STATUS SETTINGS LOGOUT IP Address 192 168 318 l Port Number Enable card only mode Figure 2 7 Type the IP address of GV AS Controller and click Save Back to the Web interface of GV AS Controller you should see the greem mark appear in the Setting Status field It means the connection between the fingerprint reader and GV AS Controller is established Note If the fingerprint reader fails to connect to the GV AS Controller the reader will beep till the connection is established 10 3 Fingerprint Only Mode The Fingerprint Only mode must work with the GV ASManager softw
2. GV GF 1901 1902 Figure 7 1 24 Upgrading Firmware Using the GV HUB or GV COM 1 Connect the fingerprint reader to a computer through a GV COM or GV HUB which provides the RS 485 to RS 232 function 2 Power on the fingerprint reader You can connect the 12V and GND wires from the GV AS Controller to the fingerprint reader The diagram below illustrates the connection among fingerprint reader GV COM GV HUB and a computer You can also prepare a 12V DC Power Adapter to connect the fingerprint reader to a power source GV HUB GV COM I RS 485 12V Power GVGF1901 1902 1911 1912 A GV AS Controller Figure 7 2 25 C GeoVision 7 2 Installing Software To upgrade the firmware for the fingerprint readers you need to install the AutolSP software from the software CD to the dedicated computer To install firmware upgrade software follow the steps below 1 Insert the software CD to the computer It runs automatically and the following window pops up GY GF Fingerprint Reader Install program C GeoVision Install GV GF1901 11902 firmware upgrade utility to your PC 2 Install Firmware upgrade utility Only for GY GF1911 1912 l 2 Install GeoVision USB Devices Driver 3 Browse User s Manual PDF Format 4 Download Adobe Acrobat Reader Figure 7 3 2 Select Install Firmware upgrade utility to install the AutolSP 3 Run AutolSP This dia
3. GeoVision The Vision of Security GV GF Fingerprint Reader User s Manual 2 GeoVision Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use GF1901 1902 1911 1912 A GeoVision 2012 GeoVision Inc All rights reserved Under the copyright laws this manual may not be copied in whole or in part without the written consent of GeoVision Every effort has been made to ensure that the information in this manual is accurate GeoVision Inc makes no expressed or implied warranty of any kind and assumes no responsibility for errors or omissions No liability is assumed for incidental or consequential damages arising from the use of the information or products contained herein Features and specifications are subject to change without notice GeoVision Inc 9F No 246 Sec 1 Neihu Rd Neihu District Taipei Taiwan Tel 886 2 8797 8377 Fax 886 2 8797 8335 http www geovision com tw Trademarks used in this manual Geo Vision the GeoVision logo and GV series products are trademarks of GeoVision Inc Windows and Windows XP are registered trademarks of Microsoft Corporation October 2012 Regulatory Nebe ii Eg E EA AEE E AESA EE A E A lil 1 Mr 1 Fv 2 eV 2 SEAN ee adnd 3 1 4 Compatible Versions for Network Connection rrrrnrrrnarrnnnrrnnnrnranennnrnnnnrnnnnennnnn 3 2 Connecting GV AS Controlle
4. L Forefinger 2953203333 32 H E Tokyo m L Forefinger 3138621061 32 L Thumb 3141242501 32 we L Forefinger 3071512197 32 L Thumb 2006062011 32 m L Forefinger 2050429883 32 L Forefinger 2145203131 32 m L Forefinger 2044138427 32 4 m R Forefinger 2061882299 32 9 D15 03 Staircase 9 D15 10 Meeting Total Fingerprints 0 Total Fingerprints 431 Figure 3 6 6 To upload the fingerprints to a door or a controller select the desired Door Gate or controller in the top left panel If you have assigned multiple controllers to a door group select the desired door group in the bottom left panel See Uploading Fingerprints to Controllers Using Door Groups later in this chapter to see how to set up door groups 7 Select the desired fingerprint data on the right side The Add button becomes available Click the Add button to upload the selected fingerprint data to the selected Door Gate or door group When the uploading is complete check marks will appear in the In Enter or Out Exit columns The resulting window after uploading may look like this a Fingerprint Access Se r 3 gt 2 Fingerpr Card W C ou ot L Thu 200606 32 L Thu 20200 32 L Foref 205042 32 L Foref 307151 32 L Foref 196044 32 Fingerprint Card w L Thumb 31033 L Forefinger 30826 L F refinger 315
5. Configuration page appears Type Serial Number of your fingerprint reader See 1 3 Serial Number and select Function that the fingerprint reader is used for and click Submit If the fingerprint reader is detected a greem mark will appear in the Setting Status field e Other Setting e Firmware Update O we No Function vi e Account Setting O 107 hs Function vi Advanced Setting g 4 If the GV Reader is connected to GV AS Controller through Ethernet do not select the checkbox below Function Setting GV GF Fingerprint Reader Function Parameter Part1 Parameter Part2 Serial Number Function Connection Status 3603400010 Door Gate 1 Entry KJ Parameter Part3 Parameter Part4 Time Setting No Function Input Setting No Function Output 1 16 Output 17 24 Wiegand Setting No Function No Function meN NN g No Function Extended Device No Function e Extended Reader If the GV GF Fingerprint Reader is connected to GV AS Controller through Wiegand interface or Ethernet do not select checkbox below oO Figure 2 4 Note For RS 485 connection make sure to check the box before the serial number to establish connection GeoVision 2 3 Connecting through TCP IP Interface Supported models GV GF1911 1912 Physical Connection The fingerprint reader and GV AS Controll
6. Run the utility The GV NetModule Utility window appears and automatically searches for the GV AS Controller and GV GF1911 1912 on the same LAN Advanced Cancel gu A GvNetModule Utility g Search Log in Default Gate Network Intel R PR IF Address Subnet Mask 192 168 3 1240 255 255 248 00 192 166 0 10 MAC Address ODO 13 E2 01 06 DF Module Name version Device Name I Al GV DATA CAPTURE 1 0 1 200907270 pos E Gv a5210 El av asz10 Fl av ass10 Fl Gv GF1911 E Gv a5100 A5Box FI Gv Ew16 v1 0 0 20120723 v1 0 0 20120920 v1 0 0 20120920 VL1RO v1 0 6 20120204 v1 0 0 20110824 v1 0 3 20110701 Controller 1 45210 45510 Gv 3605400010 Controller 4 ODO 1 Controller 7 O0 13 E2 02 41 02 OO 13 E2 01 D7 EA 00 13 E2 01 06 41 DO 13 E2 FC 00 0A OO 13 E2 01 07 57 OO 13 E2 01 E3 33 0O 13 E2 04 DO EE Figure 2 6 Click the Module Name column to sort Find the Mac Address of the fingerprint reader to see its IP address 192 168 2 89 192 168 3 29 192 168 3 18 192 168 3 74 192 168 4 252 192 168 0 100 192 168 0 107 255 255 248 0 200 200 246 0 299 259 248 0 259 255 248 0 255 255 248 0 255 255 255 0 259 299 250 0 192 168 0 1 192 168 0 1 192 168 0 1 192 168 0 1 192 168 0 1 192 168 0 1 132 168 0 1 Intel R PR Intel R PR Intel PR Intel R PR Intel PR Broadcast Broadcast
7. the GV ASController On the Web interface of GV ASController click Wiegand Setting in the left menu The Wiegand Configuration page appears Select the function that the fingerprint reader is used for and click Submit AS810 Wiegand Configuration 8 GeoVision Basic Setting Wiegand Door Gate 1 Entry Wiegand Function Network Setting PE Wiegand B Door Gate 2 Entry Other Setting Firmware Update Wiegand C Door Gate 3 Entry Account Setting Advanced Setting Wiegand D Door Gate 4 Entry Function Setting Parameter Parti Wiegand E Door Gate 5 Entry Parameter Part2 Parameter Part3 Parameter Part4 Wiegand G Door Gate 7 Entry Wiegand F Door Gate 6 Entry Time Setting Input Setting Wiegand H Door Gate 8 Entry Output 1 16 Output 17 24 Extended Device Figure 2 2 GeoVision 2 2 Connecting through RS 485 Interface Supported models GV GF1901 1902 1911 1912 Physical Connection Use the terminal block on the above four reader models for RS 485 connection to the GV AS Controller GV AS Controller GV GF1901 1902 Figure 2 3 The table below shows the pin assignments of the fingerprint reader used for RS 485 connection Function 12V_____ GND_______ RS 485 RS 485 p Connecting GV AS Controller Function Settings To define the fingerprint reader connected to the GV ASController On the Web interface of GV ASController click Extended Reader in the left menu The Extended Reader
8. 02 R Forefinger 31717 L Forefinger 29809 ET Om ainme AE Pamela m L Foref 309569 32 di R Forefinger 31798 al oh R Fore 297024 32 L Thumb 29532 a g Taipei esli L Forefinger 31386 O Gate D a Controller 10 i J 10 D16 57 VIP Con 00000006 00000060 gt a Irvine Hae o Jo R Thumb 31412 a g Tokyo e R Forefinger 21452 L Forefinger 20441 m L Forefinger 20618 e L Thumb 19336 e L Forefinger 20831 Total Fingerprints 7 Total Fingerprints 42 Figure 3 7 15 GeoVision Tip 1 If some green checkmarks are missing in the In or Out columns right click the door gate in the Device View and select Sync GeoFinger to re upload the data 2 Each fingerprint reader can store up to 1 900 fingerprints 16 El Fingerprint Only Mode 3 3 Uploading Fingerprints Using Door Groups When a large number of GV AS Controllers are connected to the GV ASManager you can organize the GV AS Controllers into different door groups Using door groups you can quickly upload fingerprints to all the GV AS Controllers in a door group instead of uploading to each controller one by one 1 Onthe menu bar of GV ASManager click Setup and select Door groups This window appears and the connected controllers are listed on the right EE Door Group Settings Fl Controller 9 i i Gate A Figure 3 8 Click the Add Group bu
9. EE 30 Contents Regulatory Notices NICAT Ka Oy us FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment Class A This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense C 4 CE Notice This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures RoHS RoHS Compliance The Restriction of Hazardous Substances RoHS Directive is to forbid the use of hazardous materials of production To meet the RoHS Directive requirements this product is made to be RoHS compliant E WEEE Compliance This product is subject to the Waste Electrical and Electronic Equipment WEEE Directive and made compliant with the WEEE requirements Caution The fingerprint reader is designed only for indoor usage Avoid exposing to sunshine or rains To keep the fingerprint reader in good wor
10. GF1901 1902 1911 1912 data is first sent to the GV AS Controller through network connection and then sent to GV GF1901 1902 through RS 485 TCP IP RS 485 GV ASManager GV ASController GV GF1901 1902 1911 1912 Figure 3 3 For GV GF1911 1912 data can be sent directly from GV ASManager through TCP IP TCP IP GV ASManager GV ASController GV GF1911 1912 Figure 3 4 Q GeoVision To upload data from GV ASManager to GV GF1911 1912 follow the instruction below from step 1 For GV GF1901 1902 skip to step 4 A Connect GV ASManager and Fingerprint Reader GV GF1911 1912 only 1 On the menu bar of GV ASManager click Setup and select Device 2 Double click a controller and select a Gate tab This dialog box appears Controller Setup General Setup Gate 1 Gate 2 Gate 3 Gate 4 General Set Door Info Name Password 43 digite 07Y Lock Reset Time Sec 1 255 Handicap Card Held Open Time Sec 5 9999 Handicap Card Fire Action Unchange s Reader s Keypad Anti Passback Entrance Local Anti Passback Exit Globe Anti Passback GeoFinger Tiwo Person Aule Entrance 192 168 0 12 Entrance Exit gv 0123456789 Exit Time Clock Authentication Schedule Auto Check Out Alarm Event _ Held Open First Camera Tamper Second Camera Fire Alarm Acces
11. ain till beep and withdraw your finger The light again turns green and then blinks green Note It is required to scan the same fingerprint twice to complete the enrollment Step 5 Repeat Steps 3 and 4 to scan the second fingerprint if needed The same user card can store up to 2 fingerprints Step 6 Present the User Card to record fingerprints till beep The light turns green and then steady blue Then you can use the Card Plus Fingerprint on the fingerprint reader 1 You will need the corresponding user card when deleting an individual user Once you lose the user card you cannot delete its related user from the reader 2 The new fingerprints enrolled will replace the existing enrolled fingerprints 19 8 GeoVision 4 2 Deletion Card data will be deleted from the reader and fingerprint templates will be erased from the user card Cards Required for Deletion e Manager Delete Card e User Card Note For Card Fingerprint mode it is required to purchase GeoVision s user cards and tags to work with Deletion Procedures Step 1 In the standby mode the light is blue on Present the Manager Delete Card The light starts blinking red Step 2 With the light blinking red present the User Card The light starts blinking green Present the User Card again to delete all fingerprints stored in the card When the deletion is complete the light turns green and then steady blue 20 4 Card Fi
12. are and the GV GF1901 1911 reader to enroll fingerprints Through GV ASManager the fingerprint data are distributed to the fingerprint readers installed on GV AS Controllers To gain access the user s fingerprint must match the enrolled fingerprint Note GV GF1911 and GV GF1912 are only supported in GV ASManager 4 0 or later 3 1 Enrolling Fingerprints To enroll fingerprint data you need to connect GV GF1901 1911 to the computer running GV ASManager through RS 485 connection To establish RS 485 connection to the computer a RS 485 to RS 232 converter such as GV COM GV Hub or GV NET IO Card is required RS 485 GV GF1901 1911 GV HUB GV COM GV ASManager GV NET IO Card V3 1 Figure 3 1 Note 1 Fingerprint enrollment does not support Wiegand connection 2 If your GV AS Controller is not equipped with any card readers it is still required to enroll cards because each fingerprint needs to go along with a card number In this case you can create virtual card numbers to represent the enrolled fingerprints 11 Q GeoVision Before you start you have to complete the card and user enrollments See 4 3 Setting Cards and 4 6 Setting User in GV ASManger User s Manual 12 On the menu bar of GV ASmanager click Personnel and select Users The User List window appears Double click one user listed in the window The User Setup dialog box appears Click the Fingerpr
13. er can be connected together through LAN You need to prepare a 12V DC power adapter to connect the fingeprint reader to a power source GeoVision 12V DC V A Power Adapter ee onmelet GV GF1911 1912 Figure 2 5 Note Besides using a 12V DC power adapter you can choose to connect the power supplied by GV AS Controller The table below shows the pin assignments of the fingerprint reader used for power connection Pin JVIN GND Function 12V_ GND gt Function Settings After physical connection you need to define the function of the fingerprint reader on the Web interface of GV AS Controller See the Function Settings section in 2 2 Connecting through RS 485 Interface Note Make sure your GV ASController and GV ASManager suport the network connection See 1 4 Compatible Versions for Network Connection 2 Connecting GV AS Controller 2 3 1 Looking Up the IP Address By default GV GF1911 1912 is assigned with an unused IP address by the DHCP server when the fingerprint reader is connected to the network This IP address remains unchanged unless you unplug or disconnect your fingerprint reader from the network Note If your router does not support DHCP the default IP address will be 192 168 0 10 The default login ID and password are admin Follow the steps below to look up the IP address of your fingerprint reader 1 Install Net Module Utility from the Software CD 2
14. ersion and Controller firmware version work together e GV ASManager V4 0 or later e GV AS100 110 120 firmware V1 06 or later e GV AS400 firmware V1 04 or later e GV AS210 810 firmware V1 0 or later 2 Connecting GV AS Controller Depending on the model of the fingerprint reader three types of communication links are provided Wiegand RS 485 and TCP IP LAN 2 1 Connecting through Wiegand Interface Supported models GV GF1901 1902 1911 1912 Physical Connection The fingerprint reader is connected with an unshielded 9 wire cable of 100 cm 3 28 feet Connect these 4 unshielded wires to the assigned pins on the Wiegand interface of the GV AS Controller Red Black White and Green wires Rog Lg 0 12v Green HO D White DEE 4 cL 2 RL Ag 2 Bz Geen pr GND Black GV AS Controller Wiegand Interface Figure 2 1 The table below shows the wire assignments of the fingerprint reader used for Wiegand connection Wire Red Black White Green Yellow Blue Orange Brown Silver Function 12V GND Data 1 Data 0 N C N C N C ING NC gt For the wiring of extending distance it is recommended to use the standard RS 485 cable a twisted pair of 24 AWG wires The maximum distance of the Wiegand output cable should be restricted to a length of 30 meters 98 43 feet 2 Connecting GV AS Controller Function Settings To define the fingerprint reader connected to
15. g Net Module Utility supplied on the software CD For details to use the utility see 2 2 1 Looking up the IP Address GvNetModule Utility Sele ial fe G S E cal o Search Log in Setting Adwanced Reboot int pdate to I Cancel qu Module Name version Device Name MAC Address IP Address aa Mask Default Gate Network rl GY D4T4 CAPTURE V1 0 1 200907270 pos 00 13 E2 01 06 DF 192 168 3 1240 255 255 248 00 192168 0 10 Intel R PR All Gy 45210 v1 0 0 20120723 Controller 1 00 13 E2 02 41 02 192 168 2 59 255 255 248 0 192 168 0 1 InteliR FR E Gv AS210 v1 0 0 20120920 45210 OO SES 01 OF ES 192 168 329 255 200 245 0 192 168 0 1 Intel R PR Fl Y 45810 1 0 0 20120920 byenes O0 13 E2 01 06 41 192 168 3 18 255 255 248 0 192 168 0 1 Intel R PR T Gv GF1911 VI 1RO OO 13 E2 FD 00 04 192 168 3 74 255 255 248 0 192 168 0 1 Intel R PR rl SV 4510004560 V1 0 6 201 20204 merae 4 00 13 E2 01 07 57 192 168 4 252 255 255 248 0 192 168 0 1 Intel R FPR Fl GY EV16 v1 0 0 20110824 OOoO1 00 13 E2 01 63 33 192 168 0 100 255 255 255 0 192 168 0 1 Broadcast v1 0 3 20110701 Controller 7 00 13 E2 04 00 EE 192 168 0 107 255 255 255 0 192 168 0 1 Broadcast gt 1 1 4 Compatible Versions for Network Connection GV GF1911 and GV GF1912 support network connection with GV ASController and GV ASManger The network connection only works when the following ASManager software v
16. int tab This dialog box appears User Setup General Home Business User Define Fingerprint Scan GeoFinger Setting COM Port Device ID Anti duress Left hand Right hand el Thumb 032 2047333307 dt 032 2047333307 Forefinger Forefinger 032 2047333307 S N 02322047232207 vw ead Middle finger iaj Middle finger Ring finger ei Ring finger a Little finger m Little finger Figure 3 2 Click the Search button to detect the fingerprint reader connected In the Left Hand and Right Hand sections click any finger square to enroll the fingerprint Place the specific finger on the fingerprint reader It is required to register the same fingerprint twice to complete the enrollment All ten fingerprints of a user can be enrolled Use the drop down list to assign a card to the fingerprint To delete the enrolled fingerprint place the mouse pointer on the desired fingerprint image The amp button appears Click the button to delete the fingerprint For the Anti duress function select a fingerprint from the Anti duress drop down list When the user is forced to open the door under threat he can present the designated finger to activate an alarm and send a warning signal to the GV ASManager Click OK to apply the settings El Fingerprint Only Mode 3 2 Uploading Fingerprints to Fingerprint Readers There are two ways to upload fingerprint data from GV ASManager to fingerprint readers For GV
17. king condition it is recommended to have regular maintenance and physical cleaning of the reader 1 Introduction The fingerprint reader can work with GV AS Controller and GV ASManager to create a complete access control system Depending on the model of the fingerprint reader up to three types of operation modes are supported Card Fingerprint Fingerprint Only and Card Only Card Fingerprint Mode GV GF1901 1902 1911 1912 With the fingerprint reader only you can enroll and manage users through the supplied Manager Enroll Card and Delete Card along with optional MIFARE user cards The fingerprint templates are stored in the user card The user gains access by scanning both his finger and his card The reader compares the presented finger with digital template stored in the card If the finger is successfully authenticated a signal is sent to momentarily activate the door relay of the controller Fingerprint Only Mode GV GF1901 1902 1911 1912 The fingerprints are enrolled through a GV GF1901 GV GF1911 reader installed on the computer running the GV ASManager software The fingerprint data are distributed through GV ASManager to the assigned fingerprint readers installed on GV AS Controllers for access control Card Only Mode GV GF1911 1912 This mode requires the users to present their cards only to be granted access GeoVision 1 1 Packing List If any of the items are missing or damaged contact y
18. log box appears File Version PcH T1073 VYWL OBS Build 091215 Current ere GOR comz COM3 Cancel 11 04 02 Scan Comm Port COML gt l Figure 7 4 26 Upgrading Firmware Wait for the AutolSP detecting the COM port that the fingerprint reader is connected to and automatically upgrading the firmware When the AutolSP automatically finishes firmware upgrading the current version number shown in the dialog box will match the file version number Click EI to close the dialog box File EP PCH T1073 V1l ORS Build 091215 Current Version IPGM T1O73 W1 ORS Build 091215 17 43 15 Scan Comm Port Device On CONS Update Another Figure 7 5 27 GeoVision Specifications Indoor use only Wiegand 26 RS 485 Wiegand 26 RS 485 0 71 x 0 51 in 0 79 x 0 67 in Fingerprint Card Fingerprint Card 1 900 for Fingerprint Only mode 18014443A MIFARE Class 13 56 MHz 1 Port 1 Port 240V 2 5A 240V 2 5A DC 7 5V 12V Max 250mA 0 65 C 32 149 F 10 90 130 x 54 x 43 mm 130 x 54 x 38 mm E S 5 12 x 2 13 x 1 69 in 5 12 x 2 13 x 1 50 in Note It is required to purchase GeoVision user cards and tags to work with GV GF1901 and GV GF1902 28 Specifications Indoor use only Wiegand 26 RS 485 TCP IP LAN 18x 13 mm 20 x 17 mm 0 71 x 0 51 in 0 79 x 0 67 in Fingerprint Only Fingerprint Card Card Only 1 900 for Fingerprint O
19. ngerprint Mode 4 3 Fingerprint Reader on Service After you connect the fingerprint reader to the controller present the user card The light on the reader will start blinking blue Then scan your finger to gain access 1 If the presented fingerprint matches any record in the card the light will turn from blue to green Access signal will be passed to the controller 2 If the presented fingerprint does NOT match the record in the card the light will turn from steady blue to blinking red with beeps for three times Then the light will come back to a steady blue The reader will not pass access signal to the controller 21 5 Card Only Mode This access mode allowing the users to only present their cards to be granted access is only supported by GV GF1911 and GV GF1912 This mode supports any MIFARE class card adhering to IS014443A and with 56 MHz For third party MIFARE class card you need to access the Web interface of GV GF1911 1912 and select Enable card only mode to enable the function To access the Web interface see 2 3 1 Looking up the IP Address to find the fingerprint reader s IP address for login if amp i GeoVision _ a Ep F T i e a S ae STATUS SETTINGS LOGOUT Port Number Figure 3 9 22 6 Connecting an Alarm Device For the user of GV GF1901 1902 1911 1912 you can connect one output device like a siren to the reader for warning when the access is g
20. nly mode IS014443A MIFARE Class 13 56 MHz 1 Port 240V 2 5A DC 7 5V 12V Max 250mA 0 50 C 32 122 F 10 a 90 130 x 54 x 43 mm 130 x 54 x 38 mm 5 12 x 2 13 x 1 69 in 5 12 x 2 13 x 1 50 in For Card Fingerpring mode it is required to purcahse GeoVision s cards and tags to work with 2 For data sychronization with GV ASController and GV ASManager through LAN it only supports when the following controller firmware version and software version work together e GV ASManager V4 0 or later GV AS100 110 120 V1 06 or later GV AS400 V1 04 or later GV AS210 810 V1 0 or later 29 C GeoVision Ordering Information 81 MA13560 F002 81 MK135 1F2 E70 GFING 001 30
21. our dealer to arrange a replacement Fingerprint reader x 1 with a cable of 100 cm 3 28 feet Manager Enroll Card x 1 Manager Delete Card x 1 Self Tapping Screw M3 x 6L x 2 Self Tapping Screw M4 x 15L x 3 Plastic Screw Anchor x 3 GV GF1901 1902 Plastic Screw Anchor x 4 GV GF1911 1912 e Buzzer Hole Plate e Security Torx e Software CD 1 2 Options You can order the following optional accessories The user card comes in two forms Card and Tag They look similar to the following examples You can find the serial number Fxxx xxxxx at the bottom right corner of the card or at the center of the tag F138 08572 The package includes one reader mount and one USB cable using for firmware upgrade See 6 Upgrading Firmware later Note For GV GF1901 and GV GF1902 it is required to purchase GeoVision s user cards and tags to work with For Card Fingerprint Mode it is required to purchase GeoVision s user cards and tags to work with Be sure that your user card has the serial number starting with the letter F otherwise you cannot record the fingerprints to the user card 1 Introduction 1 3 Serial Number To find the serial number of your fingerpirnt reader see the XID number on the back of fingerprint reader mm GeoUision a Model NO GeoFinger FOR NO GF 1901 NOR LEIET 001 For GV GF1911 and GV GF1912 you can also find the serial number of your fingerprint reader by usin
22. r rrrararnrrernnrornrrrrarernnrnnanennnrenanennnnennnen 4 2 1 Connecting through Wiegand Interface rrnnrnnnnnvnvnrnnnnerrnvnvnrnnvrennnrrenrnnerenrnrennn 4 2 2 Connecting through RS 485 Interface rrrrrarrrrnnrerrarrernnnerranrrrnnnerranenrnsrennnnennnn 6 2 3 Connecting through TCP IP Interface rrrrrnrrnnnnnerrnnrnrnnnernnnrrrnnrernanenrnnnennnnennnn 8 3 Fingerprint Only Mode rrranonnnennnrnnnrnnnrnnnrnnnrnnnnnnanenanenanenanennnennnen 11 21 ETA ENE eee 11 3 2 Uploading Fingerprints to Fingerprint Readers rrrnnrrnnnrrnnvrvnnrrnnnrennvrrnnrennvrennr 13 3 3 Uploading Fingerprints Using Door Groups cccceseeeceeeeceeeeseeseeeeseeesaeeenaees 17 4 Card Fingerprint MOde ccccececsecceseetseeeeseeteseeeeeteneenseeteneenees 18 A SPOUT ese cade ssaaasmn tan sadn sane dain sain sadn snes ait yeas eum esegenameoutecemenenesan 18 A DN NE 20 4 3 Fingerprint Reader on ServiCe ccccccccceeccceseeecececeeeeceeeeseeeesseeeeseueeseesesseeesees 21 Card Only Mode EE 22 6 Connecting an Alarm Device rrrnrnnnanennnnenanennnnennnrnnanennnnnnnnennunene 23 7 VM Pene 24 7 1 Connecting tO A Computer rrrarrrnannrnnanevrannrnnnnrnranenrnnnennnnennansnnnnnennanennnnsennassnnn 24 7 2 Installing Software rrrarrornnrrrrarnrrnnnerrannrrnnnerrnnrnrnnnennanrnnnnnennanennnnsennnnennnsennnsen 26 TNT Ne prec cesses sees cerca aneerse ener ie stone pears E OE 28 Ordering Information E
23. ranted The example below illustrates the connection of an output device to the fingerprint reader Connect point on the output device to COM on the fingerprint reader connect the points of the output device and the external power supply together and connect the point on the external power supply to NO or NC on the fingerprint reader based on the state of the output device External Power Output Device GV GF 1901 1902 Figure 6 1 23 7 Upgrading Firmware For the user of GV GF1901 1902 1911 1912 you can upgrade the firmware to the new version Firmware upgrade is done through the AutolSP software which are available on the software CD The AutolSP software will detect the current version of your fingerprint reader and then automatically upgrade it to the new version 7 1 Connecting to a Computer You need to connect the fingerprint reader to a computer for firmware upgrade For this connection one of these optional accessories is required a USB cable see PC Service Package 1 2 Options GV HUB or GV COM Using the USB Cable Using the USB cable from the optional PC Service Package connect the fingerprint reader to a computer as illustrated below USB Cable AB VAAABA AAABAABARAABABB 2 BHAAHBBAABA ABB ABOA BAABA BAAB A ABABA AABAABDBABBARB ABA ARBAB AAB BA A A
24. s Denied Alarm Continuous Time Sec 1710 Camera Mapping Figure 3 5 3 Under GeoFinger select Entrance or Exit and type the IP address of the GV GF1911 14 1912 or type gv and the 10 digit serial number see 7 3 Serieal Number For example GV 0123456789 El Fingerprint Only Mode Define Fingerprint Readers on the Controller Web Interface 4 Ensure the fingerprint reader has been set up on the GV AS Controller When the fingerprint reader is detected on the GV AS Controller a green mark should appear in the Setting Status field on the GV AS Controller s Web interface See the Function Settings section in 2 1 Connecting through Wiegand Interface Select and Upload Fingerprints Data on GV ASManager to Fingeprint Readers 5 Onthe menu bar of GV ASManager click Setup and select Fingerprint Access This dialog box appears lt Fingerprint Access ven k ad Controller 9 Cardholder Fingerprint Card Number e Fingerprint Card Number Ca E onie L Thumb 2222222222 32 EEE L Forefinger 309369613 32 m L Forefinger 1960448955 32 ii al ee w R Forefinger 2970242693 32 I 10 D16 57 VIP Con m L Forefinger 3103362693 32 J 10 D16 46 Door Le ie R Forefinger 3082653317 32 E 10 D16 45 Door Le PA ic L Thumb 3150286469 32 A F Cantraller 1 5 i L Forefinger 3171700357 32 gt j g R Thumb 2980974213 32 H K Taipei m R Forefinger 3179826821 32 E ED Irvine Remove irl
25. tton amp A new group is created Click the new group and click the Rename Group button ML to rename the group Select the door group and then select the controllers to add to the group RR NR Click the Add button The selected GV AS Controllers are now assigned to the group Lg Door Group Settings j phe m Taipei ee Irvine Al Controller 17 Mi Tokyo Staircase 52 Staircase 51 F Controller 18 a Conference Room 5 Controller 19 Conference Room 9 Conference Room 5 l O Conference Room 9 Conference Room 4 mT UIT Figure 3 9 17 4 Card Fingerprint Mode 4 1 Enrollment The user s fingerprints are stored in the user card and each user card can store up to 2 fingerprints The user must gain access by scanning both the user card and the finger Cards Required for Enrollment e Manager Enroll Card e User Card Note For Card Fingerprint mode it is required to purchase GeoVision s user cards and tags to work with Enrollment Procedures Step 1 In the standby mode the light is blue on Present the Manager Enroll Card The light starts blinking green Step 2 Present the User Card till the light blinks blue Or present the Manager Enroll Card to exit the enroll mode 18 4 Card Fingerprint Mode Step 3 With the light blinking blue scan your fingerprint till beep Withdraw your finger The light turns green and then blinks blue Step 4 Scan the same fingerprint ag