1. cantly lower energy costs If you do not have room for as large of a diame ter as is needed in order to have good ventilation it can pay to select two ventilation ducts with a smaller diame ter The increased purchase expenses this causes will in turn be saved a num ber of times over in the form of lower electricity consumption High pressure makes for large stresses on the entire ventilation system and costs large sums in terms of energy consumption By using ducts with a larger diameter or alternatively multiple ventilation ducts you can save large quantities of energy and a great deal of money A rule of thumb If you reduce the RPMs of the fan by 20 you will save approx 50 in power expenses Ventiflex the safest ducting 11 PROTAN Ventiflex Selection of Supplier The reliable injection of air through a ventilation duct of high quality is without a doubt the best investment that can be made in an underground project Both workers and machines will be more productive when the air supply has the best possible con ditions Many examples exist of projects on which savings of 2 3 have been made in purchasing prices for the ventilation system but which have subsequently endured many produc tion stoppages because damages had caused such large leaks that nearly no air was being transported to the workplace Every stoppage costs many times more than the normal price differential betwe
2. PROTAN Ventiflex De installation Prior to de installation while every thing is still hanging up the ducts in the ventilation line should be sorted and marked such that they can be packed into the following three sepa rate classes Ducts which are free of defects and have no damage Ducts which have damage holes and need to be repaired Ducts which are in such bad condition that it can not be regarded as profi table to repair them i e scrap Class 1 Class 2 Class 3 The content of all pallets must be clearly marked i e quality dimension number of ducts running metres and class Suspension hooks should be new for each installation of the ducts Hence when de installing the suspension hooks should be cut with wire cutters so that they are not sitting in the eyes Due to considerations for the working environment all ventilation ducts should be cleaned when they are reused This is most easily done while the ducts are hanging up and right after de installation Vehicles and or equipment which are used in the de installation should also be cleaned Take the ducts down one at a time and pack them up sort them by class and place them on pallets which are tied down Since the duct textile does not rot itis not necessary to dry the ducts before storing them If itis not possible to perform cleaning while the ducts are suspended then they must be cleaned prior to packing Prior t
3. Protan was founded in 1939 lts first product was a lifejacket made of latex impregnated linen cloth Since then the coating of technical textiles has comprised the core expertise of the firm At present the company has four prod uct groups Roof coverings Wall coverings Technical textiles and Ventiflex ventilation ducts Ventilation ducts have been produced since 1949 More than 750 000 run ning metres are produced annually with diameters ranging from 20 cm to 300 cm in different lengths and quali ties and with different coupling sys tems Protan is one of the world s largest manufacturers of ventilation ducts These are sold all over the world Why Life long experience in weaving coating and welding in addition to enthusiastic employees results in products with a high level of quality and satisfied customers We hope that the information in this manual will make you as a user of Ventiflex still more satisfied Protan s head office in Drammen Photo Fjellanger Widerge AS The factory complex at Nesbyen Photo Fjellanger Widerge AS Ventiflex the safest ducting 5 PROTAN Ventiflex Product Description Ventiflex ventilation ducts consist of a woven or knitted textile made from polyester yarn coated on both sides with softened PVC polyvinyl chloride normally yellow on the outer side and black on the inner side The polyester textile gives the ve
4. exists of the presence of methane gas then 1 m s should be used The objective is to determine how much air in m s is needed at the bot tom of the tunnel in order for the return velocity to be sufficient and in order to be able to dilute gasses so that it is possible to breathe the air without it posing a health hazard In order to clear diesel gas out a mini mum of 4 m of air kW min is required at the bottom of the tunnel 6 m kW min for a motor without a particle fil ter An estimate is made of how many kW are being used simultaneously in the tunnel and then the computation is made to determine the total amount in m of air second Each person who is in the tunnel needs 3 5 m of air minute and a comp utation is made to determine how many people are normally in the tun nel at the same time then the total amount is worked out in m minute The two results obtained are then added together and approx 10 is added for blasting gas The end result is what at a minimum is needed in terms of air at the bottom of the tun nel in m minute In order to compute how many m sec ond have to come out of the fan the leakage in the ventilation ducts have to be computed A well mounted ventilation line of good quality has a leakage of less than 1 100 metres If the ventilation line is poor a higher amount of leakage must be reckoned with This value is added to the quantity of m minute that has been computed for the b
5. Impregilo Spa J F Shea Co USA Jaiprakash Ind Ltd Kali und Salz GmbH Larsen 8 Toubro Ltd L mminkainen Oy Leonard Nilsen amp S nner LKAB Kiruna Outukumpu Oy NCC International AB NCC Tunneling AS Nishimatsu Construction Co Ltd Odebrecht Philip Holzman AG Sargin Construction Selmer Skanska AS Skanska International AB Statens Vegvesen Statkraft Anlegg A S Tara Mines Ltd Traylor Bros Inc Jay Dee Wayss und Freitag AG V gverket AB Zinkgruvan Ammeberg AB Walter Bau AG Universale Bau Mount Isa Mines Ventiflex the safest ducting 30 PROTAN Ventiflex Protan AS P O Box 420 Braker ya N 3002 Drammen Norway Tel 47 32 22 16 00 Fax 47 32 22 17 00 www protan com
6. omissions must be corrected such as all holes should be repaired loops and sharp bends in the ventilation line must be stretched out defective or damaged coupling rings must be replaced defective suspension wires must be replaced or repaired suspension wires which are hanging against a bolt should be moved past the bolt bolts which have come loose must be refastened slack suspension wires must be tightened check the fan motor gratings and other equipment During the inspection the airspeed and pressure in the ventilation line as well as the power consumption meter on the fan should be read and rec orded Ventiflex the safest ducting 18 PROTAN Ventiflex Repairs Repairs of Ventiflex using a hand held welder Pe x Leister Triac 1460 W hand held hot air welder pressure roller and spare ele ment Hot air welding of a patch and use of the pressure roller Hot air welding of a patch seen from the Welding course at Protan outside Ventiflex the safest ducting 19 PROTAN Ventiflex All holes and damage to the ventilation line must be repaired as soon as possible Holes in the duct textile are most easily repaired by welding a patch on with a Leister Triac hot air welder while the duct is suspended and the air is flowing 1 Cut out the damaged area if it is frayed 2 Wash aro
7. ring and a loose duct end gives a large amount of flexibility and different duct lengths can easily be cut in order to be adapted to the geometry of the tun nel Zip couplings have been used since 1984 and can be a good alternative for long lengths of ventilation duct and large diameters Suitable projects are long straight TBM tunnels The zip coupling is permanently mounted in the end of the duct and is joined together with the end of the next duct in a simple manner Probably the best coupling at present is a soft coupling It has a mecha nically interlocking fabric strip that is permanently mounted on the duct It cannot be ruined and can be used for many years Ventiflex the safest ducting 14 PROTAN Ventiflex A Cable hanging 1 1 Fasten the cable with a cable lock to bolt A f Drill and fix bolt F in a low point on the tunnel roof approx 25 m from A a D and at the same distance I from the mid line as bolt A 2 Stretch the cable with suitable tools and fix it with 2 vr a cable lock to bolt F A iS Ventiflex the safest ducting 15 Q PROTAN Ventiflex 3 Drill holes for bolts B E at distances of approx 5 metres Mount the cable on bolts B E with galvanised steel wire of diameter 3 mm with the straightest possible line between A and E The cable must not be drawn through the bolt eyes Fasten the duct with su
8. H PROTAN Ventiflex VENTIFLEX MANUAL Edited by G ran Hansson Svein Haaland Peder Lien Translated by Inter Set Oversettelsesbyr AS of Oslo Norway November 2001 Trykk Lier Grafiske 08 2004 Q PROTAN Ventiflex The information in this manual is based upon prevailing instructions and directions Protan AS reserves the right to make changes and denies responsibility for conditions which might occur such as changes in trade regulations Contingent liability claims cannot be charged against Protan AS No part of this document must be reproduced without the express permission of Protan AS Ventiflex the safest ducting Q PROTAN Ventiflex Table of Contents page o A ON 5 Produet deseription mistica o Ea 6 Manufacturi asien aarne ion Y Ma terialiproperlies u 0 een 8 Quality COMO gt asimila dd 9 Selection of quality size and coupling systems 10 Selection of supplier 12 General advice and tips 13 ISA ATION u een as 14 Inspection and maintenance 2440nsnnnennnnnnennnnnennnnnn 18 REDAS Lederens ara 19 Replacement of damaged ventilation ducts 23 De inst llation soii ii 25 SMA nit do 26 Computation of air requirements ooooccccinnccconnnccinncccccnanccaninncnn 27 List of referenco S un aaa 30 Ventiflex the safest ducting Q PROTAN Ventiflex Preface
9. avoid electricity costs which are too high the ventilation line must have as large a diameter as possible A large diameter makes it easier for the air to flow and requires less power from the fan If the pressure in the ventilation line is too high requires a lot of power from the fan the diameter must be in creased If this is not possible due to insufficient room then two ventilation lines should be mounted instead of one The same quantity of air in two ducts instead of one duct requires 1 2 the quantity of air 1 4 of the pressure and 1 8 of the energy consumption the power from the fan It is always economically sound to invest in high quality for the ventilation line and to treat it well A good properly installed and non leaking ventilation line provides not only a good working environment for the employees bit it also provides such large energy savings that a 20 40 difference in the price of the ventilation line is insignificant Ventiflex the safest ducting 29 PROTAN Ventiflex List of references AF Spesialprosjekt Alpine Bau GmbH Beton und Monierbau GmbH Bilfinger Berger Bauaktiengesell schaft Balfour Beatty Ltd UK Boliden Mineral AB Bouygues France Caledonian Mining Carbosulcis Dillingham Construction USA Dragados Constructiones S A Dumez Z blin AG Entrecanales S A Fletcher UK llbau Austria Gammon India Ltd Hindustan Construction Ltd Hochtief AG
10. btained which requires less effort in terms of maintenance and which provides more fresh air to the workplace In addition you have some spare capacity which can be beneficial to have in the event that any unforeseen events occur What is good quality The strength originates from the yarn and the weave Plastic on both sides protects the yarn and the weave against both wear and externally imposed stresses A good quality ventilation duct always has stabilised yarn in the weave This provides a geometrically stable duct that provides less turbulence ayarn design which allows the threads the possibility to move When subjected to loads this provides a collection of threads that makes it more difficult to tear the textile apart aplastic coating that is thick enough to protect the weave and yarn against both wear and externally imposed stresses aplastic coating which is thick enough to provide good fire protection Basically a knitted weave with stabilised yarn that has stronger weft threads than warp threads and a thick plastic coating provides the strongest and most optimum material for ventilation ducts The diameter on the ventilation duct must always be computed to be as large as possible A duct with a large diameter provides more air than a smaller duct alternatively it gives the same quantity of air but with signifi Ventiflex the safest ducting 10 PROTAN Ventiflex
11. en a good and less good ventilation duct The best guarantee is to purchase the ventilation duct from a serious supp lier a supplier with longstanding experience and with continuous and professional production A good piece of advice would be to require ISO 9001 certification It is also good to require ISO 14001 which shows that the supplier is not just producing the product but is also interested in it being produced and used in an environmentally appropriate manner A supplier who has these quality certifications has a good know ledge of how the product is used and can make a great deal of expertise as well as a high level of service available for both installation and operation Ventiflex the safest ducting 12 PROTAN Ventiflex General Advice and Tips A ventilation duct is intended to be able to provide a certain quantity of fresh air to the people who work in the tunnel as well as to machines that are not powered by electricity A proper ventilation calculation takes into account minor damages which can arise when machines hook into the the ventilation duct If the damaged areas are too numerous or too extensive the air will leak out on its way through the duct and less air will reach the people who are working furthest inside the tunnel Example How large is the leakage in a ventilation duct with a diameter of 1 m and a pressure of 3000 Pa Through a damaged area tear that is 10 cm
12. ependent upon temperature and the presence of other materials for example copper Smoke will also be released consisting of soot and plasticiser Ventiflex the safest ducting PROTAN Ventiflex Quality Control All raw materials are thoroughly tested for a considerable time prior to being granted approval Suppliers of yarn and chemicals are recognised inter national firms Protan s production system including its formulas procedures and specifi cations are subject to an ISO 9001 quality assurance system A well equipped laboratory thoroughly Protan is also environmentally certified tests raw materials and checks the coated under ISO 14001 materials on an on going basis Ventiflex the safest ducting 9 PROTAN Ventiflex Selection of Quality Size and Coupling Systems Having the best possible ventilation duct is of great importance to both workers and machines A ventilation duct of good quality makes for more fresh airto the workplace a lower num ber of injuries less extensive injuries and requires less power from the fan in comparison with a ventilation duct of poorer quality If the ventilation duct is of good quality a somewhat larger fan should be selected than is necessary This will make for a lower number of RPMs for the fan and hence significant savings as regards electricity In other words for a lower total cost a better ventilation system can be o
13. following manner 1 Cut out the damaged area if it is frayed 2 Wash the duct textile with VENTANON cleaning liquid around the hole 3 Size the patch to the hole Allow a minimum of 6 cm for the adhesive surface around the hole 4 Smear VENTLIM adhesive on both the duct textile and the patch Let the adhesive dry for a number of minutes until it ceases to be sticky Press the patch into place over the hole It is advantageous to go over it with a pressure roller 5 Tighten a pressure band around the duct so that it covers the patch and then let this sit for several days If the hole is too large or if the duct textile is thoroughly wet then the duct should be taken down and dried Rep air the hole in the same manner as described above however a load instead of a pressure band is used Make sure that the patch does not stick to the duct textile opposite the hole Ventiflex the safest ducting 21 Q PROTAN Ventiflex If VENTLIM adhesive thickens in the box it can be thinned with VENTANON cleaning liquid Patching materials are available in a standard kit For larger repairs the duct should be sent to Pro tan AS The Ventiflex repair kit contains Ventlim adhesive brushes Ventanon washing preparation pressure band needle thread and ventilation duct textile Ventiflex the safest ducting 22 PROTAN Ventiflex Replacement of damaged ventilation duct
14. liable method for welding PVC coated textiles and the only welding method that produces a weld just as strong as the material Hot air welding should only be used for repairs see the section entitled Repairs Finally packed for shipment Ventiflex the safest ducting Q PROTAN Ventiflex Material Properties The materials used for Ventiflex are made to meet the requirements posed for the operation of modern tunnels and mines The textile provides the requisite tensile strength to withstand the high internal pressure Larger duct dia meters require stronger textiles and hence more and thicker threads The specially developed knitted text ile gives the material a high tear resistance and thus prevents small holes and cracks from growing and causing the entire duct to tear The coating gives very good protection against most chemicals water sun light UV radiation and gasses Thicker coatings provide better wear resistance All Ventiflex qualities are self extinguishing tested regularly by an independent institute which is to say that in the event of a fire the duct will burn as long as itis exposed to flames but it will go out when the source of the fire is removed as opposed to most other organic materials which will continue to burn In the event of fire the duct will emit gas ses such as water vapour carbon dioxide and traces of gaseous hydrochloric acid the latter is d
15. long approx 0 5 m of air will disappear per second Through a damaged area tear that is 30 cm long approx 5 m of air will disappear per second i e 10 times as much Thus it is extremely important that the ventilation duct be constantly main tained and that damaged areas be repaired as soon as possible The maintenance expenses are mini mal in comparison with what the extra consumption of electricity costs A 10 increase in the fan capacity in order to increase the quantity of air increases the power consumption by 22 The risk of a significant incident in which work needs to be stopped due to the lack of air also increases with the number of unrepaired damaged areas Ventiflex the safest ducting 13 PROTAN Ventiflex Installation Flexible ventilation ducts can be connected together in many different manners The most simple and reliable is with a steel ring on the end of the duct which is inserted into a loose end on the next duct and a coupling ring of steel which is fitted over the joint and fastened This provides a simple and reliable connection For larger dia meters it can be simpler to use two piece coupling rings There can also be steel rings on both ends of the duct In this case one ring is inserted into the other and fastened with an external coupling ring Coupling rings are available with dif ferent profiles for one or two inner rings A coupling system with an inner
16. nti lation ducts its mechanical strength Different textile thicknesses are used in the different duct qualities More detailed information can be found in the material specifications The textile is made in accordance with specifications provided by Protan including for the number of threads per cm and type of yarn for warp and weft The coating on the textile makes the ventilation duct air and water tight protects the yarn against UV radiation and chemical effects of light plus it makes it possible to weld the individual sheets together into a circular duct Thicker coatings provide better wear resistance The coating consists of PVC plasti ciser stabiliser fire retardant agents and pigments Knitted textile Woven textile Ventiflex the safest ducting 6 PROTAN Ventiflex Manufacturing The textile normally approx 2 m wide is coated on both sides in a coating machine in accordance with Protan s material specification See the mate rial specifications for more specific details A specially made machine turns and welds different lengths of the coated textile into a duct which is marked with the brand name Ventiflex a quality designation and production data date month and year The suspension sys tem is automatically mounted on the duct as well as it being cut to the right length and finally packed for shipment High frequency welding is used which is the most re
17. o reuse ducts with damage should be repaired and in such case preferably at Protan Used ducts should preferably be used at the end of a ventilation line Ventiflex the safest ducting 25 Q PROTAN Ventiflex Storage Ventilation ducts should always by sto red on pallets which are securely tied down and marked see the section on de installation Ventiflex can be sto red outdoors however it is beneficial for the ducts to be screened from strong sunlight and extreme heat either by covering the ducts or even better by storing them indoors Several pallets with used ventilation ducts that have been properly packed and tied down with tension straps Ventiflex the safest ducting 26 PROTAN Ventiflex Computation of Air Requirements It is extremely important for the people who work underground to have fresh air to breathe If the air is full of diesel gas blasting gas or dust there is a large risk that life threatening accidents can arise Ventilation computations for under ground work are normally performed using a computer program This is based upon SIA 196 It is however quite simple for anyone who wishes to acquire a sense for the magnitude of the amount of air required to perform a simple computation on their own In order to efficiently dilute dangerous gasses and dust a return speed for air in the tunnel of between 0 3 and 0 6 m s is normally required if a risk
18. ottom of the tunnel The minimum value arrived at in m minute should then be increased by a margin of safety Ventiflex the safest ducting 27 PROTAN Ventiflex Once you know how much air is needed in terms of m second then you go to the Ventiflex Nomogram where you can read off the pressure in the duct for different diameters as well as the power that is required from the fan Correct computational formulas look like the following a Computational formulas Static pressure in the duct Ap Ao AXID e p 2 o U length m pressure loss over AX average coefficient of friction diameter of the duct m specific gravity of 1 m of air kg average velocity in the length concerned m vo ELL b Dynamic pressure in the duct Ap p12 e U c Pressure loss at intake bends outlets and also changes of diameter etc For each we have to calculate Ap Gepl2eU E Zeta coefficient for singular loss d In order to arrive at the total pressure pt required we must add pt Ap Ap dynamic Ap AP e Computation of energy consumption for the fan is based upon the following formula N Q Pfan I nv e nm kW Q airflow from the fan m s Pfan total pressure from the fan Pa nv efficiency of the fan 0 4 gt 0 85 nm efficiency of the motor approx 0 95 Ventiflex the safest ducting 28 PROTAN Ventiflex In order to
19. s A ventilation line which has a damaged duct in the middle and an adjacent duct on each side is reinforced with straps Dismounting a damaged duct When replacing one or more ventilat ion ducts in a ventilation line it is very important that adjacent parts of the line are secured before the ducts are dismounted The following procedure is recommended 1 Some lifting straps are required as well as a lashing belt i e a lifting strap with a ratchet 7 p en AAA em r m D Y r gt Sa e m a a next to the damaged duct with the straps being fastened to the bolt above Approx 5 m in on the adjoining duct fasten a lifting strap around the duct With the ratchet between them fasten the opposite end of the belt to a bolt above the duct that is to be replaced The adjoining duct is then ratcheted towards the duct s that are to be replaced such that there clearly is slack in the ventilation line Ventiflex the safest ducting 23 Q PROTAN Ventiflex 5 Open the couplings and take 7 Detach the lashing belt and lifting down the ducts concerned straps and remove them 6 Suspend new the duct s and 8 After approx one week inspect tighten as best as possible before the ventilation line If there is any coupling slack or kinks in the line then they must be tightened up xOO A Te AS PTI Insertion of new duct Ventiflex the safest ducting 24
20. spension wire which is adjusted such that the ventila tion duct is hanging absolutely straight Ventiflex the safest ducting 16 Q PROTAN Ventiflex B Installing ducts s aa MESS SE See O mm u a a E NEE See 4 Fix the duct with the sus pension wire Use the wire to adjust the distance from the cable to the duct to en sure that the latter is always hanging straight The wire must not be lashed to the cable but form a loop around it allowing the duct to move freely 5 Pull the next duct section with approx 10 cm overlap over the welded on steel ring at the end of the duct already in position Fit the coupling ring over the steel ring and fasten it to the cable Ventiflex the safest ducting 17 PROTAN Ventiflex Inspection and Maintenance When a tunnel is being bored the length of the ventilation line will be continually increasing and as a con sequence of this the pressure in the ducts will increase Small scratches in the duct textile will also be able to crack due to the increase in pressure such that what once was a scratch becomes a hole For this reason periodic inspections must thus be performed of the entire length of the ventilation line also on the upper side for example once per week Operational and on site conditions determine precisely how often such inspections are necessary Inspection of duct During inspections all defects and
21. und the damaged area with VENTANON cleaning liquid 3 If the hole is spreading then sew it together first with narrow strips of textile or sewing thread 4 Size the patch for the hole Allow 5 cm for welding around the hole Corners should be rounded off 5 Spot weld the patch to the duct textile so that it is firmly attached 6 Weld the patch to the duct textile by running the hot air welder between the duct textile and the patch from the hole and out towards the edge of the patch and then press it afterwards with the pressure roller at a distance of 1 1 5 cm from the nozzle opening Begin at the middle of the patch and weld outwards to each end A good and properly executed patch will be just as strong as the duct textile itself It is important that the temperature on the hot air welder is set properly and adjusted for the skill level During the welding a small amount of smoke will be generated You should avoid inhaling this for an extended period of time Let the natural draught in the tunnel remove the smoke Always cool off the hot air welder before turning it off Ventiflex the safest ducting 20 PROTAN Ventiflex Repairs of Ventiflex with VENTLIM Cans with VENTLIM VENTANON pressure band and adhesive brush Application of adhesive rg Pressure band applied If the duct textile is dry repairs with adhesive can be performed in the