Home

INNO SCAN HP - ELV Tehnika

image

Contents

1. INNO SCAN HP User Instructions 5 14 2013 ADJ Products LLC all rights reserved Information specifications diagrams images and instructions herein are subject to change without notice ADJ Products LLC logo and identifying product names and numbers herein are trademarks of ADJ Products LLC Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ADJ Products LLC brands and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe unsufficient and negligent as sembly installation rigging and operation of this product Europe Energy Saving Notice Energy Saving Matters EuP 2009 125 EC Saving electric
2. Universal DMX Control This function allows you to use a Elatione universal DMX 512 controller to control the chases and patterns dimmer and strobe A DMX controller allows you to create unique programs tailored to your individual needs 1 The Inno Scan HP has 2 DMX channel modes an 9 channel mode and 12 channel mode See pages 19 24 for detailed description of the DMX values and traits To control your fixture in DMX mode follow the set up procedures on pages 5 7 as well as the set up specifications that are includ ed with your DMX controller Use the controller s faders to control the various DMX fixture traits This will allow you to create your own programs Follow the instructions on page 9 to set the DMX address For longer cable runs more than a 100 feet use a terminator on the last fixture N See ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 16 Inno Scan HP Operation 7 For help operating in DMX mode consult the manual included with your DMX controller Sound Active Mode This mode allows either single unit or several units linked together to run to the beat of the music 1 Press the MENU button until Sound Mode is displayed and press ENTER Press the UP or DOWN buttons so that ON is displayed and press ENTER 2 The sound sensitivity can be adjusted by pressing the MENU button until Sound Sense is displayed Press ENTER and use the UP and DOWN buttons to adjust t
3. Inno Scan HP Specifications Model Inno Scan HP Voltage 100V 240V 50 60Hz LED 1 x 80W LED Power Consumption 108W Dimensions 22 75 L x 11 W x 8 25 H 578mm x 278mm x 209mm Beam Angle 16 Degree Weight 16 Lbs 7 3 kgs Fuse 5 Amp Duty Cycle None DMX 9 Channels amp 12 Channels Colors 8 White Gobos 23 8mm Size 19mm Viewable Sound Active Yes Working Position Any Safe Secure Position Warranty 2 Year 730 days Auto Sensing Voltage This fixture contains a automatic volt age switch which will auto sense the voltage when it is plugged into the power source Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 30 ADJ Products LLC 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 2650 Fax 323 725 6100 Web www adj com E mail info americandj com A D J Supply Europe B V Junostraat 2 6468 EW Kerkrade Netherlands E PEE AEE service adjgroup eu www adj eu youtube com adjlighting Tel 31 45 546 85 00 Fax 31 45 546 85 99 Follow Us On HOM facebook com americandj
4. Press the MENU button until Dimmer Limit is displayed press ENTER 2 Anumber between 50 100 will be displayed Press the UP or DOWN buttons to adjust the LED output intensity 50 being medium intensity and 100 being full intensity 3 When you have found your desired setting press ENTER to confirm Sound Mode tn this mode the unit will run in sound active mode 1 Press the MENU button until Sound Mode is displayed press ENTER 2 Either On or Off will now be displayed Use the UP or DOWN buttons to toggle between On and Off 3 Press ENTER to confirm your selection the press and hold the MENU button to activate Sound Sense In this mode you can adjust the sound sensitivity of the sound active mode 1 Press the MENU button until Sound Sense is displayed press ENTER 2 Press the UP or DOWN buttons to adjust the sensitivity level The sensitivity level can be adjusted between 0 the lowest and 100 most sensitive 3 Press ENTER to set you desired level ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 11 Inno Scan HP System Menu DMX State This mode can be used as a precaution mode that in case the DMX signal is lost the operating mode chosen in the setup is the running mode the fixture will go into when the DMX signal is lost You can also set this as the operating mode you would like the unit to return to when power is applied 1 Press
5. 2 XLR Male Socket XLR Female Socket 1 oe 2 O Figure 3 XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment negative TPE EEEE Pin 3 Data True positive poccco Special Note Line Termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a cable terminator ADJ part number Z DMX T will decrease the possibilities of erratic behavior Termination reduces signal errors and avoids signal transmission problems G and interference It is always advisable A p to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture Figure 4 ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 6 Inno Scan HP Set Up 5 Pin XLR DMX Connectors Some manufactures use 5 pin DMX 512 data cables for DATA transmission in place of 3 pin 5 pin DMX fixtures may be implemented in a 3 pin DMX line When inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a proper cable conversion 3 Pin XLR to 5 Pin XLR Conve
6. GOBO INDEXING CLOCKWISE ROTATION FAST SLOW STOP COUNTER CLOCKWISE ROTATION SLOW FAST RESET BLACKOUT NO FUNCTION ENABLE BLACKOUT WHILE PAN TILT MOVE DISABLE BLACKOUT WHILE PAN TILT MOVE ENABLE BLACKOUT WHILE COLOR CHANGE DISABLE BLACKOUT WHILE COLOR CHANGE ENABLE BLACKOUT WHILE GOBO CHANGE DISABLE BLACKOUT WHILE GOB CHANGE NO FUNCTION RESET ALL NO FUNCTION SOUND ACTIVE ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 23 Inno Scan HP 12 Channel Mode Function 12 DIMMER MODE 0 20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DEFAULT DIMMER SETTING ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 24 Inno Scan HP Gobo Replacement This unit comes with interchangable gobos When changing the gobos please be very careful Follow the instructions below and see the figure pictures on the next page Caution Never open the unit when in use Always disconnect the main power before attempting to change the gobos 1 Start by standing the fixture upright so that it is sitting on the bottom handles Unscrew the two phillips screws located on the front panel just underneath the air vents 2 Carefully remove the front panel to access the gobo wheel 3 Rotate the gobo wheel with your hand until you find the gobo you would like to change 4 Using a pair of needle nose pliers grab the retainer ring that holds the gobo in place and remo
7. energy is a key to help protecting the enviroment Please turn off all electrical products when they are not in use To avoid power consumption in idle mode disconnect all electrical equipment from power when not in use Thank you Inno Scan HP General Information Unpacking Thank you for purchasing the Inno Scan HP by ADJ Products LLC Every Inno Scan HP has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all equipment necessary to operate the unit has arrived intact In the event damage has been found or parts are missing please contact our toll free customer support number for fur ther instructions Please do not return this unit to your dealer without contacting customer support first Introduction The Inno Scan HP is a DMX intelligent LED scanner The Inno Scan HP has three operating modes a sound active show mode DMX controlled The Inno Scan HP can operate as a stand alone fixture or in a Master Slave configuration For best results use fog or special effects smoke to enhance the beams projections Customer Support ADJ Products LLC provides a toll free cus tomer support line to provide help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web
8. of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization was issued to purchaser by ADJ Products LLC if the product is damaged because not properly maintained as set forth in the instruction manual This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above ADJ Products LLC will replace defective parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear indentifying marks to that effect ADJ Products LLC reserves the right to make changes in design and or improvements upon it s products without any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by ADJ Products LLC in connection with this product including warranties of merchantability or fitness a
9. Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates l e smoke fog residue dust dew In heavy club use we recommend cleaning on a monthly basis Periodic cleaning will ensure longevity and crisp out put 1 Use normal glass cleaner and a soft cloth to wipe down the out side casing 2 Use a brush to wipe down the cooling vents and fan grill 3 Clean the external optics with glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all parts completely before plugging the unit back in Inno Scan HP Trouble Shooting Trouble Shooting Listed below are a few common problems that you may encounter with solutions No light output from the unit 1 Be sure the external fuse has not blown The fuse is located on the bottom panel of the unit 2 Be sure the fuse holder is completely and properly seated Unit does not respond to sound 1 Low frequencies bass should cause the unit to react to sound Tapping on the microphone quiet or high pitched sounds may not activate the unit ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 27 Inno Scan HP Warranty MANUFACTURER S LIMITED WARRANTY A ADJ Products LLC here
10. ER button and the software vesion will be dis played 2 Press the MENU button to leave this function Defaults This will reset the unit to its default settings 1 Tap the MENU button until Defaults is displayed Press the ENTER button and either Yes or No will be displayed 2 Press the MENU button to leave this function Restart Use this function to reset the unit 1 Tap the MENU button until Restart is displayed press ENTER 2 The fixture will now reset ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 14 Inno Scan HP Offset Adjustment Menu r Pan Offset _ 9 255 Tilt Offset __0 255 MENU Si Color Offset 127 127 Gobo Offset 127 127 To enter the offset adjustment submenu press the ENTER button for at least 5 seconds In this submenu you are able to adjust the original position of the pan tilt gobo wheel and color wheel Pan Offset Adjustment of the Pan position 1 Press the ENTER button for at least 5 seconds then press the UP or DOWN buttons so that Pan Offset is displayed press ENTER 2 Use the UP and DOWN buttons to make your adjustments and then press ENTER to confirm Press the MENU button for one second to exit Tilt Offset Adjustment of the Tilt position 1 Press the ENTER button for at least 5 seconds then press the UP or DOWN buttons so that Tilt Offset is displayed press ENTER 2 Use the UP an
11. When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX and Master Slave Operation The Inno Scan HP can be controlled via DMX 512 proto col The Inno Scan HP has an 9 channel mode and 12 channel mode The DMX address is set electronically using the controls on the front panel of the unit Your unit and your DMX controller reauire a aoproved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all pro fessional sound and lighting stores Your cables should be made with a male and female XLR con Figure 1 ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 5 Inno Scan HP Set Up nector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior COMMON DMX512 OUT DMX512 IN 3 PIN XLR DMX 3 PIN XLR Figure
12. al shock and fire in case of an internal short Disconnect from main power before making any type of connection Do not remove the cover under any conditions There are no user serviceable parts inside Never operate this unit when it s cover is removed Always be sure to mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product out doors voids all warranties Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs convenience recep tacles and the point where they exit from the appliance Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 27 for cleaning details Heat This fixture should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A Objects have fallen or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance ADJ Products LLC www adj com Inno S
13. as a Slave BLACKOUT 1 Using approved DMX data cables daisy chain your units togeth OPEN er via the XLR connector on the rear of the units Remember the 7 STROBING SLOW FAST Male XLR connector is the input and the Female XLR connector 132 139 OPEN is the output The first unit in the chain master will use the female 140 181 FAST OPEN SLOW CLOSE XLR connector only The last unit in the chain will use the male 182 189 OPEN XLR connector only For longer cable runs we suggest a termina 190 231 FAST CLOSE SLOW OPEN tor at the last fixture 232 239 OPEN 2 On the Master unit find your desired show and set that show by 240 247 RANDOM STROBE pressing the ENTER button 248 255 OPEN 3 On the slave units tap the MENU button until Slave Mode is COLOR WHEEL displayed and Press ENTER Choose either Slave 1 or Slave 0 14 WHITE 2 and press ENTER See page 10 for more info 15 21 WHITE RED 4 The slave units will now follow the Master unit 22 28 RED 29 35 RED BLUE 36 42 BLUE 43 49 BLUE GREEN 50 56 GREEN 57 63 GREEN YELLOW 64 70 YELLOW 71 77 YELLOW PINK 78 84 PINK 85 91 PINK LIGHT BLUE 92 98 LIGHT BLUE 99 105 LIGHT BLUE LIGHT GREEN 106 112 LIGHT GREEN 113 119 LIGHT GREEN LIGHT YELLOW 120 127 LIGHT YELLOW 128 191 CLOCKWISE ROTATION FAST SLOW 192 255 COUNTER CLOCKWISE ROTATION SLOW FAST To access the split colors split color mode must be activated in the syst
14. at www adj com for any comments or suggestions Service Hours are Monday through Friday 8 00 a m to 4 30 p m Pacific Standard Time Voice 800 322 6337 Fax 323 582 2941 E mail support americandj com To purchase parts online visit http parts americandj com Warning To prevent or reduce the risk of electrical shock or fire do not expose this unit to rain or moisture Warning This may cause severe eye damage Avoid looking directly into the light source at all times ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 2 Inno Scan HP General Instructions To optimize the performance of this product please read these operating instructions carefully to familiarize yourself with the basic operations of this unit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Inno Scan HP Features 2 DMX Channel Modes 9 Channels amp 12 Channels 3 Operating Modes Sound Active Show Mode amp DMX Control Internal Microphone e Digital Display for Address and Function Setting UC3 Controller Not Included 12 Preprogrammed Shows 8 Colors White 6 Replaceable Gobos Spot Inno Scan HP Warranty Registration The Inno Scan HP carries a 2 year 730 days limited warranty Please fill out the enclosed warranty card to validate your purchase and war ranty You may also register your product onli
15. ayed 3 Press the UP or DOWN buttons to find your desired dimmer curve and press ENTER to confirm See the Dimmer Curve Chart on page 22 Slave Mode This will let you set unit as a master or slave in a master slave configuration 1 Press the MENU button until Slave Mode is displayed press ENTER Either Slave 1 or Slave 2 will be displayed 2 Press the UP or DOWN buttons until your desired setting is displayed then press ENTER to confim NOTE In a Master Slave configuration you can make one fixture the Master and then set the next fixture to Slave 2 the fixtures will now have contrast movement to each other Split Color Split Color mode With this mode active color output will be split and whole This mode needs to be activated for the split color to work in DMX Mode 1 Press the MENU button until Split Color is displayed press ENTER 2 Either Yes or No will now be displayed Use the UP or DOWN buttons to toggle between Yes and No 3 Press ENTER to confirm your selection the press and hold the MENU button to activate ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 10 Inno Scan HP System Menu Dimmer Limit In this mode you can adjust the LED output intensity This adjustment is used to match up with the output intensity of other LEDs Over time LEDs will start to fade this mode will let you match the intensity of a faded LED 1
16. by warrants to the original purchaser ADJ Products LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase see specific warranty period on reverse This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibility to establish the date and place of purchase by acceptable evidence at the time service is sought For warranty service you must obtain a Return Authorization number RA before sending back the product please contact ADJ Products LLC Service Department at 800 322 6337 Send the pro duct only to the ADJ Products LLC factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty ADJ Products LLC will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in it s original package No accessories should be shipped with the product If any accessories are shipped with the product ADJ Products LLC shall have no liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof This warranty is void if the serial number has been altered or removed if the product is modified in any manner which ADJ Products LLC concludes after inspection affects the reliability
17. can HP Instruction Manual Page 4 Inno Scan HP Set Up Power Supply The ADJ Inno Scan HP contains a automatic volt age switch which will auto sense the voltage when it is plugged into a power source With this switch there is no need to worry about the correct power voltage this unit can be plugged in anywhere DMX 512 DMX is short for Digital Multiplex This is a universal pro tocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions from the controller to the fix ture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle Therefore the first fixture controlled by the controller could be the last fixture in the chain
18. d DOWN buttons to make your adjustments and then press ENTER to confirm Press the MENU button for one second to exit Color Offset Adjustment of the color wheel 1 Press the ENTER button for at least 5 seconds then press the UP or DOWN buttons so that Color Offset is displayed press ENTER 2 Use the UP and DOWN buttons to make your adjustments and then press ENTER to confirm Press the MENU button for one second to exit Gobo Offset Adjustment of the gobo wheel 1 Press the ENTER button for at least 5 seconds then press the UP ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 15 Inno Scan HP Offset Adjustment Menu or DOWN buttons so that Gobo Offset is displayed press ENTER 2 Use the UP and DOWN buttons to make your adjustments and then press ENTER to confirm Press the MENU button for one second to exit Inno Scan HP Operation Operating Modes The Inno Scan HP can operate in three different modes In each mode you can run the fixture as a stand alone fixture or in a master slave confiugration This next section will detail the dif ferences in the operating modes e Sound Active mode The fixture will react to sound chasing through the built in programs e Show mode The fixture will run one of 12 shows e DMX control mode This function will allow you to control each individual fixtures traits with a standard DMX 512 controller such as the Elatione Show Designer
19. el Mode Function PAN 0 168 TILT 0 52 TILT FINE 0 255 PAN TILT MOVE SPEED SLOW FAST See ee 7 0 7 8 15 16 131 132 139 140 181 182 189 190 231 232 239 240 247 248 255 0 14 15 21 22 28 29 35 36 42 43 49 50 56 57 63 64 70 Ti 77 78 84 85 91 92 98 99 105 106 112 113 119 120 127 128 191 192 255 DIMMER 0 100 STROBE BLACKOUT OPEN STROBING SLOW FAST OPEN FAST OPEN SLOW CLOSE OPEN FAST CLOSE SLOW OPEN OPEN RANDOM STROBE OPEN COLOR WHEEL WHITE WHITE RED RED RED BLUE BLUE BLUE GREEN GREEN GREEN YELLOW YELLOW YELLOW PINK PINK PINK LIGHT BLUE LIGHT BLUE LIGHT BLUE LIGHT GREEN LIGHT GREEN LIGHT GREEN LIGHT YELLOW LIGHT YELLOW CLOCKWISE ROTATION FAST SLOW CCW ROTATION SLOW FAST ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 22 Inno Scan HP 12 Channel Mode 9 0 9 10 18 19 27 28 36 37 45 46 54 55 63 64 74 75 85 86 95 96 106 107 116 117 127 128 189 190 193 194 255 0 127 128 189 190 193 194 255 0 69 70 79 80 89 90 99 100 109 110 119 120 129 130 199 200 209 210 239 240 255 Function GOBO WHEEL OPEN GOBO 1 GOBO 2 GOBO 3 GOBO 4 GOBO 5 GOBO 6 GOBO 1 SHAKE GOBO 2 SHAKE GOBO 3 SHAKE GOBO 4 SHAKE GOBO 5 SHAKE GOBO 6 SHAKE CLOCKWISE ROTATION FAST SLOW STOP COUNTER CLOCKWISE ROTATION SLOW FAST GOBO ROTATION
20. em menu Please see page 10 ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 18 ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 19 Inno Scan HP 9 Channel Mode Inno Inno Scan HP 9 Channel Mode HP 9 Channel Mode Function 7 5 GOBO WHEEL DIMMER MODE 0 9 OPEN 0 20 STANDARD 10 18 GOBO 1 21 40 STAGE 19 27 GOBO 2 41 60 TV 28 36 GOBO 3 61 80 ARCHITECTURAL 37 45 GOBO 4 81 100 THEATRE 46 54 GOBO 5 101 255 DEFAULT DIMMER SETTING 55 63 GOBO 6 64 74 GOBO 1 SHAKE 75 85 GOBO 2 SHAKE 86 95 GOBO 3 SHAKE 96 106 GOBO 4 SHAKIE 107 116 GOBO 5 SHAKE 117 127 GOBO 6 SHAKE 128 189 CLOCKWISE ROTATION FAST SLOW 190 193 STOP 194 255 COUNTER CLOCKWISE ROTATION SLOW FAST GOBO ROTATION 0 127 GOBO INDEXING 128 189 CLOCKWISE ROTATION FAST SLOW 190 193 STOP 194 255 COUNTER CLOCKWISE ROTATION SLOW FAST DIMMER 0 100 RESET BLACKOUT 0 69 NO FUNCTION 70 79 ENABLE BLACKOUT WHILE PAN TILT MOVE 80 89 DISABLE BLACKOUT WHILE PAN TILT MOVE 90 99 ENABLE BLACKOUT WHILE COLOR CHANGE 100 109 DISABLE BLACKOUT WHILE COLOR CHANGE 110 119 ENABLE BLACKOUT WHILE GOBO CHANGE 120 129 DISABLE BLACKOUT WHILE GOB CHANGE 130 199 NO FUNCTION 200 209 RESET ALL 210 239 NO FUNCTION 240 255 SOUND ACTIVE ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 20 ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 21 Inno Scan HP 12 Chann
21. he sound sensitivity O being the least sensitive and 100 being the most 3 The optional UC3 Controller not included may be used to con trol different functions including blackout Show Mode This mode allows either a single unit or several units linked together to run one of four shows that you choose 1 Press the MENU button until Show Mode is displayed and press ENTER 2 Press the UP or DOWN buttons until you find your desired show and press ENTER 3 The optional UC3 Controller not included may be used to con trol different functions including blackout Inno Scan HP UC3 Control Stand By Blackout the unit Function 14 Strobe in synchronization Select Movement Color Gobo selection 2 strobe in 1 12 1 Press shortly for color desynchronization change 3 Strobe by music 2 Hold on for Gobo change Mode Sound Movement Gobo Color LED OFF LED Blinking LED ON ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 17 Inno Scan HP Master Slave Configuration Inno Scan HP 9 Channel Mode Master Slave Configuration This function will allow you to link up Function to 16 units together and operate without a controller The units will PAN 0 168 be sound activated In Master Slave operation one unit will act as the TILT 0 52 controlling unit and the others will react to the controlling units pro STROBE grams Any unit can act as a Master or
22. ivate the Pan inversion press the UP or DOWN buttons until Yes is displayed press ENTER to confim To deactivate Pan inversion select No and press Enter Tilt Invert Tilt Inversion 1 Press the MENU button until Tilt Invert is displayed press ENTER Either Yes or No will be displayed 2 To activate the Tilt inversion press the UP or DOWN buttons until Yes is displayed press ENTER to confim To deactivate Tilt inversion select No and press Enter Auto Test This function will run a self test program 1 Press the MENU button until Auto Test is displayed press ENTER 2 The fixture will now run a self test Press the MENU button to exit Fixture Temp With this function you can display the running temperature of the unit 1 Tap the MENU button until Fixture Temp is displayed press ENTER 2 The current running temperature of the fixture will now be displayed Press MENU to exit Function Hours with this function you can display the running time of the unit ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 13 Inno Scan HP System Menu 1 Press the MENU button until Function Hours is displayed press ENTER 2 The running time of the fixture will now be displayed Press MENU to exit Software Version This will display the software ver sion 1 Tap the MENU button until Software Version is displayed Press the ENT
23. ne at www americandj com All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A num ber If the unit is under warranty you must provide a copy of your proof of purchase invoice Please contact ADJ customer support for a R A number Inno Scan HP Handling Precautions Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty In the unlikely event your unit may require service please contact ADJ Products LLC During operation the housing may become extremely hot Avoid touch ing the unit with bare hands while in use ADJ Products LLC will not accept any liability for any resulting dam ages caused by the non observance of this manual or any unauthor ized modification to this unit ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 3 Inno Scan HP Safety Precautions For Your Own Personal Safety Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not spill water or other liquids into or on to your unit Do not attempt to operate this unit if the power cord has been frayed or broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electric
24. re limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall ADJ Products LLC be liable for any loss or damage direct or consequential arising out of the use of or inability to use this product This warranty is the only written warranty applicable to ADJ Products LLC Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published This warranty was revised after December 1 2012 MANUFACTURER S LIMITED WARRANTY PERIODS e Lighting Products 1 year 365 days Limited Warranty Such as Special Effect Lighting Intelligent Lighting UV lighting Strobes Fog Machines Bubble Machines Mirror Balls Par Cans Trussing Lighting Stands etc excluding LEDs and lamps e Laser Products 90 Day Limited Warranty e L ED Products 2 year 730 days Limited Warranty excluding motors PCB boards and power supplies which have a 1 year 365 day Limited Warranty and batteries which have a 180 day limited warranty ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 28 Inno Scan HP Notes ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 29
25. rsion Conductor Ground Shield Data True signal Pin 3 Not Used Po Pin 4 Do Not Use Not Used Po Pin 5 Do Not Use 3 Pin XLR Female Out 5 Pin XLR Male In ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 7 Inno Scan HP System Menu 001 DMX Address 2 512 9Chan Channel Mode H 12Chan m Show 0 Show Mode 3 Show 12 ama Standard Stage t Dimmer Mode ___Tv_ Architec Theatre Slave 1 Slave Mode Slave 2 No Split Color Yes Dimmer Limit rh ch Sound Mode MENU Off Sound Sense Lro Master Slave t DMX State Blackout _Last State On Back Light Off Normal m Pan Invert Invert Normal r __ Tilt Invert Invert Auto Test Fixture Temp Function Hours Software Version Yes Defaults No Reset ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 8 Inno Scan HP System Menu System Menu When making adjustments press ENTER to confirm your setup then press and hold the MENU button for at least 3 seconds To exit without making any adjust ments pres
26. s the MENU button The display will lock after 30 seconds press the MENU button for 3 seconds to unlock DMX Address Set the DMX Address 1 Press the MENU button until DMX Addresss is displayed press ENTER 2 X will now be displayed X represents the displayed address Press the UP or DOWN buttons to find your desired address 3 Press ENTER to confirm and then press and hold the MENU button for at least three seconds to assign Channel Mode This will let you select your desired DMX Channel mode 1 Press the MENU button until Channel Mode is displayed press ENTER 2 X Chan will now be displayed X represents the displayed DMX channel mode Press the UP or DOWN buttons to find your desired Channel mode 3 Press ENTER to confirm Show Mode Show modes 0 12 Factory Shows 1 Press the MENU button until Show Mode is displayed press ENTER 2 Show X will now be displayed X representing a number between 0 12 Programs 1 12 are factory programs while Show 0 is random mode Press the UP or DOWN buttons to find your desired show and press ENTER to select your show ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 9 Inno Scan HP System Menu Dimmer Mode 1n this mode you can select the dimmer curve 1 Press the MENU button until Dimmer Mode is displayed press ENTER 2 The current dimmer curve setting will be displ
27. the MENU button until DMX State is displayed press ENTER 2 Either Master Slave Blackout or Last State will be dis played Choose an operating mode you would like the unit to start up in when power is applied or the DMX signal is lost e Master Slave If the DMX signal is lost or power is applied the unit will automatically go into Master Slave mode Blackout If the DMX signal is lost or power is applied the unit will automatically go into stand by mode e Last State If the DMX signal is lost the fixture will stay in the last DMX set up If power is applied and this mode is set the unit will automatically go into the last DMX set up 3 Press ENTER to confirm your desired set up Back Light With this function you can make the back light automatically turn off after one minute 1 Press the MENU button until Back Light is displayed press ENTER 2 Either ON or OFF will now be displayed Press the UP or DOWN buttons to select ON to keep the backlight on at all times or OFF to allow the backlight to turn off after 2 minutes Press any button to turn the backlight on again 3 Press ENTER to confirm ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 12 Inno Scan HP System Menu Pan Invert Pan Inversion 1 Press the MENU button until Pan Invert is displayed press ENTER Either Yes or No will be displayed 2 To act
28. ve the ring You can also remove the gobo by carefully pushing the gobo from the bot tom pushing it up and out Do this carefully so that you don t lose the retainer ring and the gobo 5 Once you have removed the gobo carefully insert your new gobo and reinsert the retainer ring 6 Reassemble the unit ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 25 Inno Scan HP Photometric Chart LUX 21980 5461 2260 1300 840 OOO o m S E m ADO GO A A E omg Distance m 0 1 0 2 0 3 0 4 0 5 0 Inno Scan HP Dimmer Curve Chart Dimmer 100 2 l l l l l l 50 l l l l l j 10 i l 0 i Te CEE i 0 Ramp Effect ares OS Fade Time 0 Ta 18 Fade Time Trise ms Town ms Trse ms Tam Standard 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 ADJ Products LLC www adj com Inno Scan HP Instruction Manual Page 26 Inno Scan HP Fuse Replacement Locate and remove the unit s power cord Once the cord has been removed located the fuse holder located inside the power socket Insert a flat head screw driver into the power socket and gently pry out the fuse holder Remove the bad fuse and replace with a new one The fuse holder has a built in socket for a spare fuse be sure not to confuse the spare fuse with active fuse Inno Scan HP Cleaning Fixture

Download Pdf Manuals