Become familiar with the Settop CELL
Contents
1. SL S USER S MANUAL Settop Cell Xtrem Rev March 2014 USER S MANUAL Index USER MANUT ee ena ee ee ene ee a eee ee 1 SEOD Gel KOM ec ee eee ee ee eee eee eee 3 Become familiar with the Settop Cell Xtrem cccccccecccceeeeceeeeeceeeeseeeeseeeeeseesesseeessaeeeseesesseeeeseeenas 4 Become familiar with the Settop Cell Xtrem Software ccccccccseccceeececeeeeseeeeeseeeeseeeesaeeeseeesseeeess 7 oaar NOOC pn aa E E A E 7 lent OGG e a a i E r 11 Working MOCGS ccccccceeecceeeceeeeceeeeeeeeeseeeseeeceeeeseeeseeeeseeeeeeeeseueesaeeseeesaueeseeseneesseessueeseneeseeeseeegs 14 Fro SSE e E E E E 14 SONE e E E E cau ieee 14 E e E E E e RE RE T T 16 Mode OxXCNAlnQe ccccecccseccceeeceucecuecceucceuseseuecsucessueesseeeeueecuseseeessusessueesaeessusessesssaeessuesseeessneess 17 Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es USER S MANUAL Settop Cell Xtrem This guide provides a general overview of the basic characteristics and instructions for setting up the Settop CELL XTREM device receiver and being able to operate with it in a simple way Step 1 charge the battery Screw the GSM antenna and connect the batteries Step 2 Set up the device as needed Learn about the functionalities of the LEDS ADDITIONAL INFORMATION Thank you for the trust you have invested in the SETTOP br
2. Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop osettop es USER S MANUAL BASE port Hiroshe 4 pin connector This connector is only used in Base or Server mode and it is the corrector through which the base corrections enter RADIO ROVER port Hiroshe 4 pin connector This connector is used in Base and Rover Server and Client mode In either case it is the port through which the equipment is set up In the Base mode we also have the data that are injected through the port in the previous point In Rover mode we have the corrections from the NTRIP base SIM Card Slot The SIM card is entered The PIN of the SIM card must be disabled TIPS How introduce SIM Card Not use a screwdriver Use a coin or similar If you Insert or Remove the SIM card ensure the Cell Xtrem is off Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es USER S MANUAL 7 Become familiar with the Settop CELL XTREM Software We execute the setup Application of the Settop Cell Xtrem installed in the field controller SETTOP v1 0 0 EJ LT q 194 ok SETTOP Connecting Connect the field controller through the RS232 setup cable to Radio Rover PORT of the Settop Cell Xtrem The device will automatically identify the Cell Xtrem and display the curren
3. LED On gt Battery or external power supply at low voltage level Coverage Level When the LED is on continuously this means we have no coverage or no SIM When we have SIM and coverage then the LED will indicate the coverage level which will vary from 1 to 4 by flashing Client LED Rover This LED indicates 2 things e At the moment of turning on the equipment this LED flashes 5 times if the equipment has been previously set up as rover whether it be in a point to point connection connected to an NTRIP base Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es USER S MANUAL e The LED glows continuously when the connection is made point to point to another Settop Cell Xtrem when the connection is made to an NTRIP base or when an NTRIP connection is made by means of a GPS receiver LED Server Base As in the Client LED point this LED indicates 2 things e lt informs us by means of 5 flashes at the moment the equipment is turned on that it is set up in Server mode e Once the equipment has been started this LED will light up if an equipment has been connected point to point to the Settop Cell Xtrem SIM Card RADIO ROVER port Correction output BASE port Correction input TIP HIROSE IMPORTANT Connect the field controller to the Radio Rover COM Port only required for configuration purposes
4. SIM card of the Settop Cell Xtrem device see page 5 Server The base transmits the corrections exclusively via Internet or via both Internet and external radio at the same time We execute the setup application of the Settop Cell Xtrem installed in the field controller Connect the field controller via the RS232 setup cable to Radio Rover PORT of the Settop Cell Xtrem The software will automatically identify the Gell Xtrem For use as Server it is advisable to use an SIM card with an assigned static IP The connection makes it possible to verify the coverage level in the work zone NB Working in Server mode requires no additional setup Using the following correction formats is not recommended RICGM3 x o CMR Using RTCM2 3 with activated GLONASS is not recommended either Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es USER S MANUAL 15 2 SETTOP v1 0 0 gt 7 qi 1915 bk Current Configuration Model CELLSTREMM SERVER SN CeOS02Z00001 Server IP null Server Port 2101 Pressing on OK will allow us to exit the application and set up the GPS receiver in basic mode in the usual manner OBSERVATION If you are working with a GPS receiver with an external radio select Custom Radio for working with the Settop Cell Xtrem Assign the correct port it will depend where is connected the speed at 38400bps and th
5. in Client mode and want to change to Server mode NB If in Client mode one must cut connection before performing the change Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es aa Ft z Y i E
6. 1 Server CEP J Si Authorizati GPS Positio Change to SERVER mode a Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es B T A Ts d i auf Thi a E a p USER S MANUAL 13 E GPS By pressing on the GPS button one can send from one position NMEA GGA channel to the server for the calculation of a virtual base This position can be Manual entering approximately a Latitude and a Longitude of the zone we are in or it can be chosen with Automatic by selecting a GPS brand on the list TRIMBLE LEICA TOPCON UNKNOWN and the communications port of the GPS SETTOP v1 0 0 SETTOP vi 0 0 Ci Manual Input 0 Manual Input Latitude 144 30 aan rus Automatic Automatic E s Connection Disconnection If you press on the Disconnection button the existing connection ends making it possible to change the current configuration Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es EET i E USER S MANUAL 14 Working modes Pre setup gt Prior to field work one can perform a previous setup of the device One can edit create or eliminate the casters list as well as users and passwords see page 4 A One can also edit the APN of the operator in the event of changing the
7. K correction reception mobile i SETTOP v1 0 0 gt pf ae 19 33 pCurrent Configuration Model CELLSTREMM SERVER SN CXOSOg t rbon Server IP i Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es oo e eee 2 Y i a pa pal USER S MANUAL 11 Client Mode f 2 SETTOP v1 0 0 ft q isce Bk Bi 2 serrop vioo e Bk Current Configuration SM Cxo30200001 Server CELLXTREM CELLATREM IP 2 10522 05 CELLATREM Porti 2101 Current Configuration Shh CxO30200001 Server CORS NET Authorization yes fernandez PS Position MANUAL DJ Automatic Connection DJ Automatic Connection If the Settop Cell Xtrem is working in Rover mode the Automatic Connection is in ON the equipment after starting will proceed to connect to the last base or the Cell Xtrem that was connected Thus we will not needed to set up the Cell Xtrem with the software if we always work in the same conditions the same NTRIP base zone etc It will only be necessary to power the equipment and if there is no problem with the SIM coverage NTRIP etc the equipment will automatically connect On the screen we can see the current configuration next to the serial number SN the name of the last server used and the user name in the event of authentification being required In those cases of connection to a Settop Cell Xtrem
8. R S MANUAL The fields required for connection are entered the Name IP address port user and password if needed If the CellXtrem box is ticked the option of entering the user and password is disabled and the port is automatically blocked at 2101 This option must be enabled when the RTK corrections of the base come from a Settop Cell Xtrem 2 SETTOP v1 0 0 E LF q 15 29 ok Narre CELLSTREM Server 2 165 22 85 e DJ M Es 2 SETTOP v1 0 0 gt if q 19 30 D Operator If the button is pressed the setup parameters of the telephone company will appear These parameters are directly supplied by the company of every country SETTOP v1 0 0 gt 27 qf is 21 ok gt SETTOP 1 0 0 gt 27 d is 15 ok Apr Apr nbergetestatico movishar es MEL Ennomens MEL agrarane7e2d2z9 cancel Cancel Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop osettop es B m T r i Ts d i auf Thi a E a USER S MANUAL 10 After the setting up when OK is pressed a pop up will appear for updating the parameters of the company Do yOu want to update the APN configuration APN configured Cellxtrerri is rebooting Fek Server to Client Pressing on the button will change the configuration from Server mode RTK correction server base to Client Mode client in RT
9. and for carrying out your professional activities Remember that you must refer to our website www settopsurvey com for information on settings quick guides and updates on our novelties The purchase of the equipment includes the warranty in accordance with the equipment supplied labor and replacement of defective parts starting on the date of delivery The SETTOP Customer Service will help you with any problem related to your new device You may contact us at settop settop es Likewise purchasing the equipment includes the Customer Service during the warranty period starting on the date of delivery The SETTOP Customer Service will help you with any doubt regarding the handling of the equipment its setting and its start up You may contact us at soporte settop es Once the warranty has expired you may opt for the annual warranty extensions Do not wait for the expiration of the warranty to contract the extension Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es USER S MANUAL Become familiar with the Settop CELL XTREM Battery Off gt Battery OK On gt Low battery Coverage Level Flashing gt Coverage OK On gt No coverage Customer LED Rover Off gt Not connected On gt Connected LED Server Base Off gt Not connected On gt Connected Battery LED Off gt Battery or external power supply OK
10. e parity at None If working with an external radio maintain the current configuration of the equipment l r Base radio ERES Gas radio EJI J ERE Customradio M Recelver port E st port Batid tate nii 38400 K Parity larity 0 TS enabled Es Connect Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es B T A Ts d i z p USER S MANUAL 16 Client CORS Netvvork SY Net vip T We execute the setup of the Settop Cell Xtrem installed in the field controller Connect the field controller via the RS232 setup cable to Radio Rover PORT of the Settop Cell Xtrem The software will automatically identify the Cell Xtrem If the Settop Cell Xtrem is working in Rover mode the Automatic Connection is in ON the equipment after starting will proceed to connect to the last base or the Cell Xtrem that was connected Thus we will not need to set up the Cell Xtrem with the software if we always work in the same conditions the same NTRIP base zone etc It will only be necessary to power the equipment and if there is no problem with the SIM coverage NTRIP etc the equipment will automatically connect Otherwise the configuration required will be minimal lf we need to connect to a Virtual Network requiring our approximate location we can press on E and select Manual location
11. t setup of the device on screen Server Mode i SETTOP v1 0 0 gt 27 qf 19 15 Dk Current Configuration Model CELLXTREMM SERVER SN CXOSOZ00001 Server IP null Server Port 2101 On the screen we can see that the equipment is a Settop CellXtrem next to the serial number SN that it is set up as server and we can also see the IP and port of this server We can also see a graphic display of the coverage level The color will indicate the coverage level gS blue 100 green 1 75 grey 0 On the lower bar we can find a series of buttons for making changes to the current configuration of the device Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop osettop es ee eee 2 Y i a ja pal USER S MANUAL E D he T Casters list By pressing on the button we shall see the list of all the available servers set up along with the user and password a SETTOP v1 0 0 E LA qi 19 31 ok Server TORS WET User USEF Password Authentification required To add a server one must press on Add SETTOP v1 0 0 E LF qE 15 29 ok Marne CORS MET Server GA 66 F2 26 Port User Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es as T r i Ts o S i nalt N ee i USE
12. the information provided is the IP and the port of the Cell Xtrem Moreover we can graphically see the coverage level The color will indicate the coverage level gS blue 100 green 1 75 grey 0 On the lower bar we can see a series of buttons with which we can carry out changes to the current set up of the device pa bE To e Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es aa Ft z Y i T i E USER S MANUAL 12 gt Casters list By pressing on the button we can see the list of all of the available servers set up along with the user and password For more information see page 4 i 2 SETTOP v1 0 0 gt 27 19 31 bk Server User USEF Authentification required i Operator If the button is pressed the setup parameters of the telephone company appear These parameters are directly supplied by the company For more information see page 5 SETTOP v1 0 0 gt 7 q is 21 ok SETTOP v1 0 0 gt 7 6115 ok APN wap cingular Apr nbernetestatico Movistar es IMEI 357973047824229 eS 367973047524229 Pa Server to Client Pressing on the button vvill change the configuration from Glient Mode client in RTK correction reception mobile to Server mode RTK correction server base i 2 SETTOP vl 0 0 gt jf We 16 39 Current Configuration Sh CROSOZ0000
13. to enter a latitude gt N gt S and a longitude gt E 20 gt 27 d 19 49 ok SEPT OP v1 0 0 d Manual Input Latitude 41 30 gu C Aubomatic lt is also possible to select in Automatic so as to send an NMEA GGA command received from the GPS by previously selecting the receiver brand on the list and the correct communications port Bofarull 14 08027 Barcelona Spain Phone 34 93 340 05 73 Fax 34 93 351 95 18 Cell 34 656 84 85 84 www settopsurvey com settop settop es USER S MANUAL 17 gt pf qe 18 41 ok SEMTOP v1 0 0 CJ Manual Input E Automatic GPS TRIMBLE Comm Port COM Es IE Start the connection of the Settop Cell Xtrem device Pressing on OK will allow us to exit the application and set up the GPS receiver in basic mode in the usual manner OBSERVATION While setting up the style select Custom Radio for working with the Settop Cell Xtrem Assign the correct port it will depend where is connected the speed at 38400bps and the parity at None Note for Trimble user s Trimble Access gt Settings gt Survey Styles gt RTK 3 Rover radio Rover radio Type Custom radio 7 Route through controller Receiver port Port 3 Parity Mode exchange One can change from working in Server mode to Client mode or vice versa by pressing on change button P If we are in Server mode and want to change to Client mode h If we are