1. Press the MODE button a third time to enter the long term calibration drift correction mode On entering the mode the previous temperature correction factor will appear on the display To make a correction measure a known fixed temperature source Enter the correction mode and press the A or Y buttons to change the correction value and minimize the difference in readings Repeat and adjust the correction value as needed until the measurement on the IR200 matches the known temperature Press the MODE button a fourth time to set the alarm buzzer status Press the A or Y buttons to switch from ON to OFF Surface Temperature Measurements 1 Set the Body Surface switch for Surface for wide range surface measurements of most materials Hold the meter by its handle and point it toward the surface to be measured Press the trigger to turn the meter on and take a temperature reading The temperature reading appears in the large display and the logged data number and value appear in the smaller display Release the Trigger and the reading will hold for approximately 7 seconds after which the meter will automatically shut off Trigger presses can occur up to a rate of one a second to quickly log samples If the temperature goes above 140 F or 60 C Hi will appear in the display If the temperature goes below 32 F or 0 C Lo will appear in the display 4 IR200 V1 0 5 09 SurfaceTemperature Mode settings 1 With the me
2. R company warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies on sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website at www extech com click on Contact Extech and go to Service Department to request an RA number A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied 2 IR200 V1 0 5 09 Meter Description COE EN OY SOW E NOP IR sensor Body Surface switch Y button A button MODE button Measurement trigger LCD display Batt
3. User s Manual EXTECH INSTRUMENTS A FLIR COMPANY Non contact Forehead IR Thermometer Model IR200 Introduction Congratulations on your purchase of the Model IR200 IR Thermometer This thermometer is intended for scanning groups of individuals or monitoring an individual for elevated temperatures It is not a substitute for a clinical thermometer Always use a clinical thermometer when high accuracy body temperature measurements are required Considerations and Warnings Read all instructions before using this product For the most accurate results make reading with an ambient room temperature of 73 to 82 F 23 to 27 C Make sure the skin is dry and that no hair interferes with the measurement Do not immerse the meter in water Avoid touching and or scratching the infrared sensor lens Always use a Clinical thermometer to verify any abnormal temperature measurements gt gt gt gt Clean the lens area by gently blowing with compressed air and use a damp swab to wipe the lens Do not use any solvents to clean the lens Measurement Notes 1 _ If the meter has been stored in a cold or hot environment allow it at least 20 minutes to acclimate to room temperature before making measurements 2 To prevent transmission of disease avoid direct contact with the skin 3 After heavy exercise always wait at least 10 minutes before taking forehead temperature readings Warranty EXTECH INSTRUMENTS CORPORATION a FLI
4. ery compartment DISPLAY OY COU BO Na Surface mode Body mode Temperature display Memory location Alarm active Temperature units Low battery icon Memory temperature display Surface temp Body 4 aan as OO 88 BABB IR200 V1 0 5 09 Operating Instructions Body Temperature Measurements 1 Set the Body Surface switch for Body for accurate measurements in the range of 86 0 to 109 F 30 to 43 C Hold the meter by its handle and point it toward the surface to be measured Measurement distance should be 2 to 6 5 to 15cm Press the trigger to turn the meter on and take a temperature reading The temperature reading appears in the large display and the logged data number and value appear in the smaller display Release the Trigger and the reading will hold for approximately 7 seconds after which the meter will automatically shut off Trigger presses can occur up to a rate of one a second to quickly log samples If the temperature goes above 109 F or 43 C Hi will appear in the display If the temperature goes below 86 F or 30 C Lo will appear in the display Body Temperature Mode settings 1 4 With the meter OFF press the MODE button once to set the C F temperature units The temperature units will flash Press the A or Y buttons to change the units Press the MODE button a second time to set the alarm temperature limit Press the A or Y buttons to change the value
5. lay with function indicators 500ms Hi or Lo 32 F to 122 F 0 C to 50 C 10 to 90 RH operating lt 80 RH storage 4 to 140 F 20 to 60 C 2 AA Batteries 7 seconds approx 6 240z 177g 6 3 x 3 2 x 1 7 160 x 82 x 42mm Extech offers repair and calibration services for the products we sell Extech also provides NIST certification for most products Call the Customer Service Department for information on calibration services available for this product Extech recommends that annual calibrations be performed to verify meter performance and accuracy 6 IR200 V1 0 5 09 a Support line 781 890 7440 Technical support Extension 200 E mail support extech com Repair amp Returns Extension 210 E mail repair extech com Product specifications subject to change without notice For the latest version of this User s Guide Software updates and other up to the minute product information visit our website www extech com Extech Instruments Corporation 285 Bear Hill Rd Waltham MA 02451 Copyright 2009 Extech Instruments Corporation a FLIR company All rights reserved including the right of reproduction in whole or in part in any form 7 IR200 V1 0 5 09 IR200 V1 0 5 09 O YI 1BUR This datasheet has been downloaded from www EEworld com cn Free Download Daily Updated Database 100 Free Datasheet Search Site 100 Free IC Replacement Search Site Convenient Electronic Dicti
6. n the compartment by removing one screw and sliding the cover off Replace the 2 AA batteries and close the battery compartment cover 5 IR200 V1 0 5 09 IR Measurement Notes The object under test should be larger than the spot target size calculated by the field 1 of view diagram printed on the side of the meter and in this guide Before measuring be sure to clean surfaces that are covered with frost oil grime etc If an object s surface is highly reflective apply masking tape or flat black paint to the surface before measuring Allow time for the paint or tape to adjust to the temperature of the surface it is covering Measurements through transparent surfaces such as glass may not be accurate Steam dust smoke etc can obscure measurements The meter automatically compensates for deviations in ambient temperature However it can take up to 30 minutes for the meter to adjust to extremely wide changes Specifications ne Treu Body Temp 86 0 to 109 F 30 to 43 C 0 5 F 0 3 C Surface Temp Emissivity Field of View IR Spectral response Display Response time Over range indication Operating Temperature Operating Humidity Storage Temperature Power Supply Automatic Power Off Weight Dimensions Calibration and Repair Services 32 0 to 140 F 0 to 60 C 1 5 F 0 8 C 0 95 fixed D S Approx 8 1 ratio D distance S spot or target 6 to 14 um wavelength Backlit LCD disp
7. onary Fast Search System www EEworld com cn All Datasheets Cannot Be Modified Without Permission Copyright Each Manufacturing Company
8. ter OFF press the MODE button once to set the C F temperature units The temperature units will flash Press the Aor Y buttons to change the units 2 Press the MODE button a second time to set the alarm temperature limit Press the Aor Y buttons to change the value 3 Press the MODE button a third time to set the alarm buzzer status Press the A or Y buttons to switch from ON to OFF Data memory To review the logged data points press both the A and Y buttons while the unit is OFF Use the A or Y buttons to scroll through the memory locations To clear logged data select the 0 memory location and press the MODE button The unit will beep twice to indicate memory has been cleared Field of View The meter s field of view is 8 1 For example if the meter is 8 20cm from the target spot the diameter of the target must greater than 1 2 5cm Other distances are shown in the field of view diagram Measurements should normally be made as close as possible to the device under test The meter can measure from greater distances but the measurement may be affected by external sources of light In addition the spot size may be so large that it encompasses surface areas not intended to be measured o 79 pa a Qu TA ca 2cm 4cm zs 16cm 32cm sae Battery Replacement When the low battery symbol appears on the display replace the meter s battery The battery compartment is located on the bottom of the handle Ope