Readme LL984 Library V4.1 for Unity Pro
Contents
1. Cancel ReadMe LL984 Library V4 1 Page 6 of 16 Rev 1 10 Unity Pro FFBLibset version selection for Unity Pro gt V4 0 This dialog only appears if you have Unity Pro gt V4 0 Here you can select the libset versions into which the LL984 Library will be installed Unity Pro manages several versions of libraries in order to preserve the current library version used in projects Example If you have selected V4 0 and V4 1 then the LL984 Library V4 1 will be installed twice into Libset version V4 0 and V4 1 Version Selection E S x Unity Pro FFBLibset version selection Select the Unity Pra FFBLibset version for installation Unity Pro libraries and families to install a Lg Packages EL lt Libraries gt Hah LL384 TN Progress Monitor Progress Monitor Unity Pro FFBLibset libranes and Families installation Contl omm Installation into libset V4 1 essct ReadMe LL984 Library V4 1 Page 7 of 16 Rev 1 10 Final screen i LL984 Library 4 1 006 a x Installation Wizard Completed The Installation Wizard has successfully installed LL9 amp 4 Library Click Finish to exit the wizard i arce 7 Uninstall or Modify LL984Lib V4 1 e Uninstall Start the setup again and select the Remove or use the Add Remove Programs function from your Windows operating system to uninstall the LL984 Library V4 1 e Modify Start the setup again and select Modify Now you will
2. P ZIN 1 02 0 16 Different prototype Analog Input x ig P ADUT 1 02 0 15 Different prototype Analog Output xij P_AVER 1 02 0 18 Different prototype Average Weighted Inputs Calc P_CALC 1 02 0 15 Different prototype Calculated preset formula J P DELA amp Y 1 02 0 15 Different prototype Time Delay Queue xij PLINTEG 1 02 0 15 Different prototype Integrate Input at Specified Int xd P LIMIT 1 02 1 14 Different prototype Limiter for the Pv ig P LIMV 1 02 O12 i 1 Different prototype Velocity Limiter for Changes in y Update Update All Hep e Inthe Library Version Management dialog click on Update All and in the following dialog Copy types to application click OK e Then select the Tab Other updatable types see picture and do the same again Now your application has been updated with the types from the new Library V4 1 ReadMe LL984 Library V4 1 Page 11 of 16 Rev 1 10 10 DDT adaptation tool The DDT adaptation tool is used to adapt a Unity application which has been created with a former version of the LL984 Library version lt 4 1 into the current Library version V4 1 This is necessary because the interface of the DFBs in the PCFL EMTH family have been changed in the LL984 Library V4 1 The DDT adaptation tool DDT Adaptation EXE has been installed together with the LL984 Library V4 1 on your PC in the folder Unity Pro Libraries N LL984 Library You can start the tool w
3. PAG PR WSRAWI2UIOFUNT DOTA AR E ONO PA ARRAY TA OF UNT DOT ONOFF PAR 11 Other important notes 11 1 Install Uninstall sequence The installation uninstall of the LL984 Library is using the Library Management services of Unity Pro In case of Unity Pro is not installed the installation uninstall of the library will fail Therefore to avoid any disturbances it is important to keep the following installation sequence Installation e First install Unity Pro e Second install the Library Uninstall e First uninstall the Library e Second uninstall Unity Pro In case you want to upgrade Unity Pro and to keep the Library it is sufficient to uninstall and re install Unity Pro Afterwards use the repair option of the LL984 Library setup to bring the library into the new installed Unity Pro 11 2 Windows Vista The installation options Repair and Modify don t work correct with Windows Vista if the User Access Control UAC is enabled If you want to use the Repair Modify option you must deactivate the UAC or uninstall the Library by using the Remove option and then Re Install the Library ReadMe LL984 Library V4 1 Page 15 of 16 Rev 1 10 EE LL984 Library 4 1 10 Program Maintenance Modify repair or remove the program Change which program Features are installed This option displays the Custom Selection dialog in which veu can change the way Features are insta
4. c Schneider Electric 1995 2011 All Rights Reserved Schneider Readme LL984 Library V4 1 for Unity Pro Product 984 Library Part number UNYLBGSLE 984L41 1 Preface The installation of LL984 library V4 1 works with Unity Pro V6 x and former Unity versions This Installation Guide will help you to obtain and install the LL984 Library V4 1 properly to Unity Pro The LL984 Library does NOT have to be registered after installation Be sure to make an Export XEF file of all your previously converted 984 applications BEFORE you upgrade Unity Pro IMPORTANT DFB Interface in PCFL EMTH family changed in Library V4 1 The DFBs in the families EMTH and PCFL use data structures DDTs instead of UINT arrays This is done to increase transparency of the converted applications When converting applications with the LL984 Converter V4 1 the new DFB interface is automatically being used by the converter If you update an application which has been converted with a LL984 Library V4 1 and which contains DFBs from the EMTH PCFL family you will get a data type mismatch error when updating this application with the new Library V4 1 For this reason the DDT Adaptation tool is installed together with the Library V4 1 Using this tool you can adapt your application to the new DFB interface in the V4 1 Library For detailed information how to adapt your application to the new Library see chapter Unity Pro Application Upgrade and DDT ad
5. see the Unity Pro FFBLibset version selection dialog Here you can install the LL984 Library into another libset version by selecting this version or you can uninstall it from the libset version by de selecting it only with Unity Pro gt V4 0 If you are going to use the Modify option under Windows Vista please read chapter Other important notes before ie LL984 Library 4 1 006 Program Maintenance Modify repair or remove the program Change which program features are installed This option displays the Custom Selection dialog in which vau can change the way features are installed Repair installation errors in the program This option fixes missing or corrupt Files shortcuts and registry entries Remove LL984 Library From your computer InstallShield lt Back Cancel ReadMe LL984 Library V4 1 Page 8 of 16 Rev 1 10 8 Unity Pro Project Settings When using FFBs from the LL984 Library within your project you need to select the following two options in the menu Tools gt Project Settings e Allow dynamic arrays ANY ARRAY XXX e Allow jump and label ST Project Settings Project Settings General Management of build messages Build settings Property label Property value Allow leading digits Ca Character set Extended PLC embedded data Allow usage of EBOOL edge e PLC diagnostics Allow INT DIMT in place of AN r_BIT Inf TES Allow bit extracti
6. x is not compatible with previous Library setups For this reason it s recommended to uninstall the Library before upgrading to Unity Pro V6 x If you want to uninstall LL984Lib V4 x and Unity Pro then you must first uninstall the Library and then Unity Pro because the uninstall of the Library is using a Unity Pro service In case of Unity Pro is not installed the Library uninstall will fail see chapter 11 for more details Existing LL 984 Library versions Unity LL984 Library Version Setup file Supported Unity Release Date Release Status Version V4 1 17 LL984 Lib V4 1 17 Setup exe V6 x V5 x 07 2011 official release V4 x V3 x V2 3 SP2 V2 3 SP2 V2 3 SP2 VBde 0 _Lib_V4 0_ V3 1e 984 Lib for Unity _v3 1e exe 14 12 2007 official release ReadMe LL984 Library V4 1 Page 2 of 16 Rev 1 10 6 Installation of LL984 Lib V4 1 Please check that you have administrator rights on your PC During the installation phase it is recommended to disable all the Antivirus services and to close all your running applications Copy the Setup file to your computer and start it Follow the instructions displayed on the screen Installation steps Welcome screen fig LL984 Library 4 1 006 a xi Welcome to Ehe Installation Wizard for LL 984 Library The Installation Wizard will install LL384 Library on your computer To continue click Next Single User License Back i Cancel User information Readme and Release note
7. RE PACKAGE UNDER LICENSE AGREEMENT IMPORTANT READ BEFORE USING This Software License Agreement was last updated on 30 Apr 2006 lel kj f T accept the terms in the license agreement we I do not accept the terms in the license agreement Installshield lt Back Cancel Customer information ip LL984 Library 4 1 006 ajl xi Customer Information vg Please enter your information l First name Last name Appel Company name Schneider Electric Install this application For Anyone who uses this computer all users C Only For me Schneider Electric Installshield lt Back Cancel ReadMe LL984 Library V4 1 Page 5 of 16 Rev 1 10 Destination Folder ep LL984 Library 4 1 006 Destination Folder Click Next to install to this Folder ar click Change to install bo a different folder Destination Folder E iInitvProva 1 Unity Pro Libraries LL984 Library Installshield Back Here you can specify the destination folder for the LL984 library documentation The path is initialized with the standard installation path of Unity Pro Ready to Install the LL984 Library Em LL984 Library 4 1 006 Ready Eo Install the Program The wizard is ready to begin installation Click Install Ea begin the installation IF you want bo review or change any of your installation settings click Back Click Cancel to exit the wizard Installshield lt Back E
8. aptation tool 2 How to get the LL984 Library The LL984 Library V4 1 for Unity Pro is available from Schneider Electric Services only Please contact your local Schneider Electric correspondent to receive a copy of this library The Library is delivered as part of a Zip archive LL984 Library V4 1 zip which contains the following files LL984 Lib V4 1 xx Setup exe LL984 Library Setup file LL984 Lib V4 1 UserManual EN pdf X User Manual for LL984 Block Library LL984 Lib V4 1 ReadMe EN pdf Installation information the present file LL984 Lib V4 1 ReleaseNotes EN pdf Latest information on LL984 Library DDTAdaptation exe xml DDT Adaptation tool ReadMe LL984 Library V4 1 Page 1 of 16 Rev 1 10 3 Compatibility with Unity Pro The LL984 Library V4 1 17 is compatible and usable with the following Unity Pro version Unity Pro V2 3 SP2 Unity Pro V3 x Unity Pro V4 x Unity Pro V5 x Unity Pro V6 x The LL984 Library can be used on Premium Quantum and M340 PLCs 4 System requirements The system requirements for the LL984 Library are the same as for your installed version of Unity Pro 5 Uninstall of older LL984 Lib versions If you have already installed a previous version of the LL984 library there is no need to uninstall the old Library before installation of the new Library because older libraries are automatically uninstalled An exception is the upgrade from Unity V5 x to Unity V6 x The Library setup for Unity V6
9. ith Start Programs gt Schneider Electric gt SoCollaborative gt Unity Pro Libraries gt LL984 Library Perform the following steps to adapt your application e Export your application with Unity Pro to an XEF file e Convert this XEF file using the DDT Adaptation tool The result is an new XEF file named xxx D XEF e f adaptations have been made number of substituted parameters gt 0 gt Import the new XEF file xxx D xef into Unity Pro gt Rebuild your application Example for DDT adaptation tool usage LL984 DDTAdaptation Enter the location of the application SEF file ta be adapted DAALL984Lib _projects ALL_LL984_FFE 5 V4DA REF xe DDTAdaptation T DDT Adaptatian Finished 3 new variable created 5 parameter substituted Result has been stored in D YLLS84Libi prajecEsyALL LL884 FFBS v4DA D xeF Restrictions for the DDT adaptation tool e Only Unity Pro applications that have been created by the LL984 Converter can be adapted e Only FDB LD section using DFBs from the PCFL EMTH family are adapted ReadMe LL984 Library V4 1 Page 12 of 16 Rev 1 10 List of DFBs which will be adapted by the DDT adaptation tool Block Parameter old new EADDDP _ADDDP SUM ARRAY 1 6 OF UINT 6 OF UINT DDT DP DDTDPUDP DP ReadMe LL984 Library V4 1 Page 13 of 16 Rev 1 10 E SINE RAD REAL PAR 2 P LKUP PAR ARRAY 1 39 OF UINT DDT LKUP PAR ReadMe LL984 Library V4 1 Page 14 of 16 Rev 1 10
10. lled Repair installation errors in the program This aption Fixes missing or corrupt Files shortcuts and registry entries Remove LL384 Library From your computer Installshield Cancel 11 3 Reset of Error Log Register The function block E ERLOG is used to visualize floating point errors which can occur during the execution of the FFBs of the EMath family In the legacy 984 application the Error Log Register EWORD is automatically reset to zero if the problem has been removed In the Unity application this is not the case If the error is removed the Error Log Register EWORD needs to be reset to Zero by the user for example by inserting a function block at the beginning of the application see picture 1 MOVE O IN OUT F EWORD E ADDFP EWLIED EWDRED ReadMe LL984 Library V4 1 Page 16 of 16 Rev 1 10
11. on of INT and WORD ra Program Se Y TSS Directly represented array variables x L omman Iv FBD Disable array size compatibility check m Project Settings i Project Settings Property label Property value General Management of build messages Build settings PLC embedded data PLE diagnostics Variables Program Languages Common FEL LD Mixed display SFC Allow jump and label If you Rebuild your project without these options you possibly will receive the error e E1208 usage of dynamic array is disabled e E1206 usage of jump statements is disabled ReadMe LL984 Library V4 1 Page 9 of 16 Rev 1 10 9 Unity Pro Application Upgrade 9 1 Overview In order to upgrade your application to LL984 Lib V4 1 you need to perform the following steps Action Comment R Step Action apiece using he all your projects using the XEF file of is created existent Unity version mo ae M LL984 Lib V4 1 xx E Uninstall old MERE l lsi Pro version otep 2 4 is only necessary if you want to upgrade your Unity Pro version too 4 Install new Unity Pro version Install LL984 Lib V4 1 xx Old LL984Lib V4 1 will be overwritten if existent Use DDT adaptation tool to convert XEF file from previous Unity version to LL984Lib V4 1 gt result is a new XEF file xxx D xef Necessary if you have used EMTH or PCFL DFBs from LL984 Lib for more details see chapter 10 au
12. s i LL984 Library 4 1 006 Readme and Release Notes Important Information v Display the contents of the Readme File v Display the contents of the Release Notes InstallShield E Cancel lt Back ReadMe LL984 Library V4 1 Page 3 of 16 Rev 1 10 jie LL984 Library 4 1 006 Readme Please read the Following readme information carefully Readme LL984 Library 4 1 for Unity Pro Part number UNYLBGSLES84L41 1 Preface The install of LL964 library V4 1 works with Unity Pro 564 1 and earlier versions This Installation Guide will help you to obtain and install the LL884 Library 4 1 properly to Unity Pra hd Installshield lt Back ji LL984 Library 4 1 006 Release Notes Please read the Following release notes carefully Release Notes LL984 Library 4 1 for Unity Pro Part number UNYLBGSLE 984L 41 1 Important Note DFB Interface in PCFL EMTH family changed in Library V4 1 The DFBs in the families EMTH and PCFL now use data structures DDTs instead of UINT arrays This is done to increase transparency of the converted applications When converting applications with the LLBa4 Installshield ReadMe LL984 Library V4 1 Page 4 of 16 Rev 1 10 License Agreement ap LL984 Library 4 1 006 License Agreement Please read the Following license agreement carefully End User License Agreement EULA COMPANIES OF THE SCHNEIDER ELECTRIC GROUP SOFTWA
13. tomatically If the dialog Copy types to application appears click OK Use Types Library Manager and For more details see chapter 9 2 upgrade your DFBs with latest versions from LL984 Lib V4 1 xx Open new XEF file with Unity Pro EFBs of your project are upgraded to LL984 Lib V4 1 um Rebuild your project Your project has been converted to II984Lib VA 1 ReadMe LL984 Library V4 1 Page 10 of 16 Rev 1 10 9 2 Update project with Library If you have installed LL984 Lib V4 1 and converted your project with the DDT adaptation tool you need to update your project with the latest DFB versions from the new Library by using the Unity Pro Types Library Manager see menu Tools Types Library Manager e Start the Types Library Manager and select the menu Compare Project with Library from the context menu The context menu is opened if you click the right mouse button in the Types Library Manager If there are no differences you will get the message No differences have been found If differences have been found the Library Version Management dialog is opened Ell LIBRARY Version Management E Some differences have been found between the types in the project and those in the library Check new versions Other updatable types Mot updatable types These types of the project also exist in the library and are different fou can choose to update your project with the library version Bx xij
Download Pdf Manuals
Related Search
Related Contents
projects microcontrollers C-700 Ultra Zoom 取扱説明書 SERVICE MANUAL - Ages Heftruck Service BV View Product Label Helium Sniffer Probe User Guide DOWNLOAD NOW ALC-601 Laser Combiner The Andor Laser Print Layout 1 VFS-001 Manual Xerox Phaser 7800 User's Manual LG GD710 Product manual Copyright © All rights reserved.