Home

User Manual - SupplyHouse.com

image

Contents

1. tekmar tekmarNet Thermostat 554 Zoning Replaces New User Manual a ee g 49 4 ror Si MODE SR A Watts Water Technologies Company 1 of 12 2015 tekmar 554_U 02 15 This brochure will provide you with the information you need to benefit the most from your tekmarNet thermostat Please visit tekmarControls com for more detailed information on this or any other tekmar product The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product Touchscreen Adjustments The touchscreen of this thermostat makes it easy to change commonly used settings Touch any item to adjust its setting You will hear a tick sound each time you touch the display When you are finished making changes touching the Home button will return to the Home screen If you do not touch the screen for 3 seconds the Home screen is automatically displayed tekmarNet Thermostat 554 Home Screen Display Heat amp Cool Adjust a settings Floor or the Time z Outdoor temperature Adjust the Schedule Room Temperature Away Key Switch between comer f T Cool amp Off Mode DESS l Return to the Mioma Home Screen uty from any menu ae
2. be set Radiant floors heat the air by raising the floor temperature Setting a floor temperature is a way of enhancing the comfort of your living space Air Temperature Only If there is only an air temperature sensor no floor sensor the thermostat operates to control your desired air temperature Floor and Air Temperature If the air sensor is turned on and a floor sensor is connected the thermostat will maintain your desired air temperature as well as a minimum floor temperature Controlling temperature this way is recommended for areas with large windows that allow the sun to shine into a room and keep it warm without the need for additional heat This can allow the floors to cool off during the afternoon When the sun goes down it can take a long time for the floors to get warm again and the room may cool off too much in the early evening A floor minimum setting can help with this condition by maintaining a floor minimum temperature Keep in mind the floor minimum temperature will override the air temperature and if set too high may overheat the room This operation is recommended for rooms with hardwood floors as well as those with large windows Setting floor minimum and maximum temperatures is a way of enhancing the comfort of your living space while protecting your floor coverings eo 90 F 32 C Suggested maximum for all floor Feels hot to the touch types other than wood 80 to 85 F 26 to 30 C Bathroom
3. 554_U 02 15 Monitor Menu The monitor menu allows you to view the following temperatures and running hours Outdoor temperature highs and lows Room temperature highs and lows Floor temperature highs and lows requires floor sensor to be installed Filter Hours Number of hours since the air filter was last replaced e Heat W Number of hours the heat relay is on e Cool Y Number of hours the cooling relay is on e Fan Number of hours the fan relay is on To clear the temperature highs and lows or the running hours 1 Touch the temperature or running hours 2 Display will show r 3 Touch Enter Toolbox Menu This menu provides advanced level information Access Change the access level on the thermostat Status Info Displays the current status of the thermostat including any overrides from the tekmarNet system control Toggles between Status Info and the current status e System Normal Thermostat is operating normally For all other thermostat status messages please see the Installation amp Operation Manual 554 _D Software Version and Type Number Display the software SW and the TYPE number A Watts Water Technologies Company 11 of 12 2015 tekmar 554_U 02 15 Frequently Asked Questions Symptom Look for Corrective Action Heat On indicates heat is on If the Heat Onis Heat On displayed and there is no heat contact your HVAC professi
4. Display of the time schedule and the away key on the Home screen is optional and can be turned on or off in the programming menus Turn the Fan on Adjust the Temperature To enter the programming menus press and hold the Home button for 3 seconds A Watts Water Technologies Company 2 of 12 2015 tekimar 554_U 02 15 Display Symbols i This thermostat displays symbols on its screen to indicate what mode it is in what temperature it is operating at or what equipment it is trying to turn on This section describes each of those symbols HEAT ON Heat On Heat is turned on COOL ON Cool On Cooling is turned on eas FAN oe The fan is turned on y SUN Operating at the occupied day temperature MOON Operating at the unoccupied night temperature ii tekmarNet Communication is present WARNING SYMBOL Indicates an error is present ARROWS AV Adjust the displayed setting GENE SCENE AWAY HWA Y Operating at Away temperature HOT TEMPORARY HOLD Jo Hold for 3 6 9 or 12 hours WWSD W W G H The outdoor air temperature is above the Warm Weather Shut Down setting which shuts off the heating system ron COOL LUUL Radiant floor cooling system is on MIN or MAX Reached the room minimum or maximum MIN FL or MAX FL Reached the floor minimum or maximum A Watts Water Technologies Company 3 of 12 2015 tekmar 554_U 02 15 Adjust th
5. ZONE e Operating one of the four systemwide schedules as a master Schedule Master 1 through 4 e Joining one of the four systemwide schedules as a member Schedule Member 1 though 4 Requires the thermostat to be connected to a tekmarNet system Once the type of schedule has been selected the thermostat can support schedules that have either e 2 events per day e 4 events per day Schedules with 4 events per day are common for residential use while 2 events per day are common for commercial installations A Watts Water Technologies Company 9 of 12 2015 tekimar 554_U 02 15 Schedule Menu Settings Co The schedules can be repeated every e 24 hours e 7 days week A 7 day schedule allows a unique time to be set to change the temperature for each day of the week The schedule also includes a SKIP option that allows the programmable schedule to skip a temperature change and remain at the previous temperature setting The SKIP setting can be found between 11 50 PM 23 50 hours and 12 00 AM 0 00 hours When a programmable schedule is selected there is a time delay for the room to warm up or cool down from the temperature to the temperature The thermostat has the option of using Optimum Start to predict the heat up or cool down rate of the room When Optimum Start is set to On the heating or cooling is started in advance to allow the room to reach the Set Room temperature at the time set
6. down arrow displays ry temporary ay TEMPORARY HOLD hold ane FAN Use the Up or Down HOLD is displayed while the arrow to select a thermostat is operating at the temperature temporary hold temperature A Watts Water Technologies Company 4 of 12 2015 tekmar 554_U 02 15 Mode of Operation i This thermostat has 4 operating modes Heat Cool Auto and Off Touch the Mode key on the screen to select the desired mode of operation Auto mode will automatically switch between heating and cooling as required The temperature is not adjustable while the thermostat is off Note If near freezing temperatures are detected the system will operate to maintain 40 F 4 5 C even in the Off mode MOJE MOJE MOTE MOJE y rir were rite E HEAT or LOU or HOTE jor OFF MODE AIR FAN MODE Ale FAN FAR FAN MODE Ale FAN Secondary Temperature Dist This thermostat can display the outdoor or floor temperature or the room heating and cooling temperature settings in the smaller number area at the top right of the screen To toggle the item currently displayed touch the secondary temperature Display of the floor or outdoor temperature requires a connection to an external floor or outdoor air sensor cee F F a ale Cool Set Heat Set Adjust the Time To change the current time touch the clock on the disp
7. e Temperature i To change the heating or cooling set temperature touch the A or V arrows to select a preferred temperature setting Press the Home button to accept the setting or leave the screen untouched for several seconds To toggle between changing the heating or cooling setting press the H lt gt C key This thermostat is capable of controlling the floor or air temperature adjusts Note The temperature is not adjustable if the thermostat is in the Away scene or in the Off mode or has been set to the Secure access level by the installer Adjust the Temperature Ter porar Temporary hold allows a user to change the temperature for a period of time and then automatically return to the permanent temperature setting This is especially useful in commercial buildings that are in use for short amounts of time When selected touching the up or down arrows changes the temperature for either 3 6 9 or 12 hours If the thermostat is using a schedule Schd provides a temporary hold until the next schedule event time After the temporary hold time expires the thermostat returns to normal operation By default the temporary hold feature is off Tap the hour TEMPORARY setting until HOLI HOLD HOLI E the preferred 2hr ae length of time When the temporary TIF S aaan NF hold feature is enabled Li L touching the up or pallial EEE ee
8. ese schedule settings are detailed later in this brochure PP This thermostat can save additional energy while you are away by lowering the heating temperature and increasing CON ARAT the cooling temperature To enable this feature touch Going IGOING AWAY Away on the screen This is only available when the Away Key has been turned on in the Scene menu e Select PERM permanent or a number of days using HAY HOL J the A or V arrow E e Press the Home button to accept the setting or leave the IIT TIIM screen untouched for several seconds JES e Scene Away is displayed on the Home screen until the number of days expires a e Touch Cancel Away to cancel at any time A Note The temperature is not adjustable while the thermostat is in Away Access Levels This thermostat has access levels It will typically be installed and programmed by a heating professional and then locked in a User Limited or Secure access level System critical settings are not be available for adjustment For more information on these settings please consult your installing contractor or this product s Installation and Operation Manual This brochure focuses on settings available to the User A Watts Water Technologies Company 6 of 12 2015 tekimar 554_U 02 15 Program Menu Settings i To Enter the Programming Menus Press and hold the Home button for 3 seconds t
9. in the programmable schedule Display Menu Settings Units Select temperature units in degrees Fahrenheit or Celsius Backlight Options Select how the display backlight operates ON The display is always at full brightness DIM When thermostat is not in use the display is dim but is at full brightness when touched DIM When the thermostat is not in use the display is dim while the schedule or scene is The display backlight is off when the schedule or scene is The thermostat display is at full brightness when touched ON 3 When the thermostat is not in use the display is at full brightness when the schedule or scene is The display backlight is off when the schedule or scene is The thermostat display is at full brightness when touched e OFF The display backlight is always off Secondary Item Select the setting to display in the upper right corner of the Home screen outdoor floor or room heating and cooling temperature Scene Menu Settings Scenes Scenes provide systemwide overrides to save energy Choose the option of having scenes not used none or have the Away scene available Away Key If scenes are available choose whether to have the Away key available or not Note When used with a tekmarNet system control to operate the heating appliance the domestic hot water tank is not heated while in Away scene A Watts Water Technologies Company 10 of 12 2015 tekmar
10. lay e Use the A or Y arrow to change the minutes hour and day e Touch NEXT ITEM to advance to the next item or BACK for the previous item To store the new time and date press the Home button or leave the screen untouched for several seconds Note The time is not visible when the thermostat is in the Away scene or if the clock display is turned off in the Time menu POA Y e A Watts Water Technologies Company 5 of 12 2015 tekmar 554_U 02 15 Programmable Schedule D This thermostat is capable of running at a lower temperature setting when you are asleep or out of the building When the schedule setting is on day and night temperature settings will display on the screen If you adjust the temperature while the sun is displayed the day setting changes If you adjust the temperature while the moon is displayed the night setting changes To adjust the times when the day and night temperature start touch the sun or moon Gon the screen Schedule Menu will display followed by the first adjustable schedule event time e Use the A or Y arrow to adjust the time for each event e Touch NEXT ITEM to advance to the next event or BACK for the previous event To accept the settings press the Home bution or leave the screen untouched for several seconds e The thermostat schedule can be set to 2 or 4 events per day repeating on a 24 hour or 7 day cycle Th
11. o enter the programming menus Select a Programming Menu e Touch NEXT to advance clockwise in the illustration below to the next menu e Touch BACK to go backwards counterclockwise in the illustration below through the menus Touch ENTER to enter a menu Setting Items Touch A or Y arrow to adjust the setting if required Touch NEXT ITEM to advance to the next item within the menu Touch BACK ITEM to go backwards to the previous item within the menu To return to the parent menu after changing a setting press and release the Home button To return to the Home screen press and release the Home button twice or wait 30 seconds to automatically return to the home screen SCREEN CLEAN TOOL 30x MENU SET TEMP MENU A NEXT fea X Press and hold for 3 seconds to access the programming menus v A Watts Water Technologies Company 7 of 12 2015 tekmar 554_U 02 15 Screen Clean Menu Entering the Screen Clean menu gives you 30 seconds to clean the thermostat and display with a moist cloth Do not use solvents to clean the thermostat Set Temp Menu l Entering the Set Temp menu allows you to permanently change both the day and night temperature settings for both heating and cooling If your thermostat is being used for radiant floor heating a floor sensor can be connected and floor minimum day 3X and night Q temperatures can
12. onal No heating Cool Onindicates cooling is on If the Cool On or Cool On is displayed and there is no cooling contact No cooling your HVAC professional NEE The thermostat is in the Off mode Touch the MODE mode key to change to Heat Cool or Auto CEN Ne No A or Y key ae Touch the Cancel Away key on the display Heat or cool Optimum Start is on and has turned on the on before C heat or cooling in advance of your schedule scheduled time change Flashing There may be a maximum room temperature MHX set Consult your HVAC professional Touching A key does Flashing The floor has reached the floor maximum notincrease MHX F setting Consult your HVAC professional temperature Flashing Warm weather shut down is in effect I laf 4 J Adjustable from your system control Touching V Flashing There may be a minimum floor temperature ucang MIN set Consult your HVAC professional key does not decrease eon The floor has reached the floor minimum setting mperatur EMPEL MTNL E Consult your HVAC professional More Information This User Brochure contains standard information on how to make adjustments to an installed product More detailed information can be found in this product s Installation and Operation Manual 554_D at tekmarControls com Product design software and literature are Copyright 2015 by tekmar Control Systems tekmar Ltd A Watts Water Technologies Compan
13. s and kitchens Suggested Feels warm to the touch maximum for wood floors 70 F 21 C Rooms with large windows to prevent Feels cool to the touch under heating in the evening lt 40 to 45 F 5 to 7 C Feels cold to the touch Freeze protection for garages A Watts Water Technologies Company 8 of 12 2015 tekmar 554_U 02 15 Time Menu Settings y Set date month and year Required for daylight savings time Daylight Save Automatic daylight saving time update for the spring and fall Time Mode Select either 12 hour or 24 hour time format Clock Select on to display the time clock in the Home menu available when schedules are not used Schedule Menu Settings Energy savings can be achieved by lowering the heating temperature and increasing the cooling temperature when the building is unoccupied or during the night When operating on a programmable schedule a or a symbol is shown in the Home menu The or indicates the current operating temperature All schedules are stored in permanent memory and are not affected by a loss of power Display Action xt Day temperature C Night temperature This thermostat can operate on a programmable schedule in order to automatically lower the heating temperature and increase the cooling temperature setting Options include Turning off the schedule OFF e Operating a schedule that applies only to this thermostat zone
14. y Head Office 5100 Silver Star Road Vernon Control Systems B C Canada V1B 3K4 250 545 7749 Fax 250 545 0650 Web Site tekmarControls com All specifications are subject 12 of 12 554 U 02 15 LK o change without notice g