1. 4 gt a OTHERS b DOME SETTINGS Al PONERTE AUTO STOP TIME 1556 bod MENU OFF TIME 5M lt PRIVACY MASK gt Di PASSWORD TILT ANGLE SET 5 lt DOME TITLE gt SPEED LEVEL HIGH 5 lt lt gt NORTH SET gt lt ADDRESS SET Gl BACK EXIT BACK EXIT Al AUTO FLIP The speed dome will rotate 180 in horizontal direction after 2 seconds if it moves to 90 in the vertical direction Choose Open Close in the menu to enable disable the function B1 AUTO STOP TIME Set the stop time for speed dome when there is no stop command 5 seconds 15 seconds 30 seconds 60 seconds for selection C1 MENU OFF TIME Automatically close the menu 1 minute 2 minutes 5 minutes 10 minutes for selection D1 TILT ANGLE SET Default angle is 3 the adjust range is from 0 8 E1 SPEED LEVEL High Mid Low F1 NORTH SET Set the ture north direction for the speed dome Enter the menu and use the joystick of keyboard to move the speed dome to the ture north direction in horizontal direction and then confirm to set G1 lt ADDRESS SET a OTHERS gt AUTO FLIP ON aoe HARD ADDRESS 001 SOFT ADDRESS 001 TILT ANGLE SET 5 lt EDIT SOFT ADDRESS gt SPEED LEVEL HIGH SOFT ADDRESS OFF lt NORTH SET gt lt ADDRESS SET gt BACK EXIT BACK EXIT 1 Hardware address has to be
2. lt SEQUENCE gt TITLE ZONE 5i LEFT LIMIT lt PATTERN gt El lt ZONES gt lt RIGHT LIMIT gt aoe Hos BACK EXIT A1 ZONE INFORMATION Show the status of zone Zones function is used to show zone information when the speed dome run to the preset zone area B1 ZONE NO Move the cursor to ZONE and press to enter the setting mode of zone number move the Joystick upward or downward to select number then press to confirm TITLE Move the cursor to lt gt and press to enter the setting mode of zone title 30 D1 LEFT LIMIT Move the cursor to LEFT LIMIT and press to start setting the left margin of the current zone Then PRESS IRIS ON TO CONFIRM will appear on the screen Use the joystick to press confirm E1 RIGHT LIMIT Move the cursor to RIGHT LIMIT gt and press to start setting the left margin of the current zone Then PRESS IRIS ON TO CONFIRM will appear on the screen Use the joystick to press confirm F1 DELETE Press to delete the current zone ZONE IS NOT SET WARNING TITLE ZONEI ARE YOU SURE lt LEFT LIMIT gt lt RIGHT LIMIT gt OK CANCEL DELETE BACK EXIT d d RESTART LANGUAGE ENGLISH WARNING lt SyYSTEM INFOMATION IE GSR ae serene cage lt DISPLAY SETUP gt ARE YOU SURE lt DOME SETTINGS gt lt CAMERA gt OK CANCEL l
3. DOME SETTINGS lt IDLE gt PRIVACY MASK gt PASSWORD lt DOME TITLE lt 5 gt EXIT g Iaw lt IDLE gt lt PRIVACY MASK gt lt PASSWORD gt lt DOME TITLE gt lt OTHERS gt BACK EXIT 4 IDLE ACTION TIME 30SEC ACTION NONE BACK EXIT d Al Bl Al TIME Move the cursor to Time to set the idle action launching time 30seconds 1 minute 5 minutes 10 minutes 30 minutes in the menu for selection press to confirm B1 ACTION Move the cursor to ACTION to set the idle actions Preset position Scan sequence Pattern None b PRIVACY MASK DOME SETTINGS PRIVACY MASK lt IDLE gt MASKNO 1 Al lt PRIVACY MASK gt ENABLE OFF Bl lt PASSWORD gt lt SET gt Cl lt DOME TITLE gt DELETE D1 lt OTHERS gt BACK BACK EXIT EXIT A1 MASK NO Move the cursor to MASK NO to set the number of privacy mask zone B1 ENABLE Enable Disable lt 5 gt set the position on the screen of the privacy mask Use joystick to move the mask square to the specified position D1 DELETE Press to delete the current privacy zone 20 PRIVACY MASK PRIVACY MASK 1 ENABLE gt OFF lt SET gt DELETE BACK EXIT C PASSWORD n DOME SETTINGS lt IDLE gt lt PRIVACY MASK gt lt PASSWORD gt lt DOME TITLE gt OTHERS
4. BACK EXIT d A1 EDIT PASSWORD The factory default password 15 111111 PASSWORD EDIT PASSWORD gt ENABLE OFF BACK EXIT Tips leftuse near rightuse far P BI ENABLE Enable disable the password protection for OSD menu WARNING MASK DELETE OK CANCEL PASSWORD EDIT PASSWORD gt ENABLE OFF BACK EXIT TIPS leftuse near rightuse far 4 45 n INPUT OLD PASSWORD INPUT NUMBER 0123456789 OK CANCEL Al Bl D DOME TITLE gt DOME SETTINGS lt IDLE gt lt PRIVACY MASK gt lt PASSWORD gt lt DOME TITLE gt lt OTHERS gt BACK EXIT OK CANCEL DOME TITLE SET INPUT lt NUMBER gt OK CNACEL d Al INPUT DOME TITLE SET TIPS leftuse near rightuse far OK CNACEL INPUT AB CD OK CANCEL DOME TITLE SET INPUT SYMBOL E NE D NC Q u amp OK CANCEL Move the cursor to INPUT and press to enter the title setting mode B1 lt CAPS Press move the joystick upward and downward to select capital or lower letters ALPHABET Move the cursor to alphabet and press to select letters D1 OK Cancel 22 1 DI H OTHERS
5. Men tem eee ERE Ete tet te ter I eh sc M 16 PANGUA uires Amat ut ten hate n LL MD een M DP ALI M LP LAE NS E 17 SYSTEM INFORMATION 17 YSSETUU 18 DONE SE IN E i eis E ee uar Ar ET 19 CAMERA REX 24 IN ES EO ERR REM RORIS PCR 26 PEPR dett ae Re Rene ertet M er Me M i EE E M E E MM 3 FACTORY OE EAS oC 32 Help nd EKA 221 soya aes cates 32 APPENDENX ier tv Mese 33 APPENDIX LIGHTNING AND SURGE PROTECTION 0 0000000000000 33 APPENDIX 2 RS485 GENERAL KNOWLEDGE ccccsccsccsccecceccosccscesccsccescescescescescessenscsscnscescessesses 34 BRIEF ITRODUCTION Do not dismantle the machine to avoid electric shock Notice To avoid electric shock do not remove the dome cover Users are not capable of fixing any internal components Only qualified person is allowed to do the repair This label indicates that there is uninsulated dangerous voltage which has risk of electric shock This label reminds there are important operating and maintenance instructions Notes To prevent fire or damage caused by electric shock do not put the speed dome into water To prevent personal injury the speed
6. such as screwdrivers coins or metal objects or a container with full of water on top of the camera If the speed dome has abnormal smell or smoke please stop using it please shut down the power to avoid fire or electric shock If the product working improperly please contact the dealer or the nearest service center Do not disassemble or in any way to change the product Problem caused by disassemble or repair from unauthorized user are not covered in warranty please clean the machine with a dry cloth and do not splash water directly on the product Do not put the product opposite the air flow position Otherwise the temperature difference between inside and outside will cause moisture condensation on it When the speed dome installed in cold area such as cold storage room please make sure it is sealed with silicone wire leads to prevent outside air come into it Otherwise high humidity air outside may flow into the machine case and internal and external temperature differences cause the product to moisture or water vapor inside Do not drop objects on the product or hit the product Keep it away from vibration or magnetic interference Do not install the product at places with high temperature over 50 C low temperature below 50 C or high humidity When moving the product assembled please make sure to turn off the power Do not keep the camera watching at the sun otherwise it will damage the CCD sensor After stored i
7. HELP ates EXIT A PRESET MOTION PRESET lt PRESET gt lt SCAN gt PRESET NO 001 Al lt SEQUENCE gt TITLE PRESET 01 Bl PATTERN CALL CI lt ZONES gt lt SET gt DI DELETE El BACK BACK EXIT EXIT A1 PRESET NO Move the cursor to lt Preset Position Number gt press to select preset number The dome cameras support 220 preset positions B1 TITLE Move the cursor to Title Setup gt press to enter the sub menu of title setup for the preset positions C1 CALL Move the cursor to Call press to call the corresponding preset positions D1 SET Press to enter setting mode when Press the icon to confirm shown on the screen it 15 available to operate the camera then press to save the new position 26 1 DELETE Move the cursor to Delete press the icon of Iris On to delete the set preset positions B SCAN MOTION lt PRESET gt lt SCAN gt lt SEQUENCE gt lt PATTERN gt lt ZONES gt BACK EXIT 4 SCAN SCAN SCAN NO 1 1 TITLE 5 1 Bl START CI LEFT LIMIT DI RIGHT LIMIT El SCAN SPEED 20 F1 BACK EXIT q P Move the cursor to lt SCAN NO to enter the setting mode of scan No use the joystick of keyboard to select digit number Then confirm and exit Each speed dome supports 8 scan paths B1 TITLE Move the cursor to lt TITLE gt to enter the setting mode of sub menu for ti
8. direction to display the rotating direction of the speed dome accurately Set area indication when speed dome run to special area it will show the area title on screen Password Protection Function To secure speed dome setting from authorized users Note Camera is not able to focus clearly in following cases Target object is not at the middle of the image Watching at two objects at the same time one near and the other is far away camera 15 not able to focus on both objects Target object with high light Target object move too fast Target object is dark or fuzzy Target object behind unclear glass 5 Chapter 2 Installation and Connection 2 1 Optional parts for installation Pedant mount bracket TC DF12 for ceiling mounting Pedant mount bracket 2 2 Warning Make sure the installation place is able to afford 4 times weight of the speed dome 2 Power supply is AC220V make sure the grounding 15 correct and do not take live action 2 3 Preparation 1 Fix the drill position sticker on wall drill 4 holes according to the indication on the sticker and then install the expansion bolts 2 Please prepare the necessary tools according to specific situations Lum adjustable wrench O cross screwdriver flathead screwdriver big small internal hexagon wrench 4mm Ls 2 4 Installation 1 Get the foam out of the carton Note Please protect camera and dome base make sure the foam is removed from th
9. set in dip switch on the speed dome board 2 Software address is a new function for easy address setup it is recommended to use it for installation 3 Edit soft dip switch 6 INPUT SOFT ADDRESS D ADDRESS SET ee eee eaea TR A A AE R INPUT lt HARD ADDRESS 001 NUMBER SOFT ADDRESS 001 0123456789 EDIT SOFT ADDRESS gt SOFT ADDRESS OFF TIPS IF PELCO P ADDRESS SET VALUE I IF PELCO D ADDRESS SET VALUE SETVALUE FROM 0 TO 254 BACK EXIT OK CANCEL d 4 lt 1 gt Input address in 3 bits 2 Tiandy Pelco P address range 1 255 Pelco D address range 1 254 3 Reboot the speed dome after setting to enable the software address function CAMERA C MAIN MENU T CAMERA SETTING n LANGUAGE ENGLISH AUTOFOCUS ON A SYSTEM INFORMATION DIGITAL ZOOM B DISPLAY SETUP BACKLIGHT ON DOME SETTINGS FREEZE ON CAMERA 4 ZOOMSPEED LOW E lt MOTION gt DAY NIGHT AUTO F RESTART IMAGE G FACTORY DEFAULTS ADVANCED HELP EXIT BACK v D C EXIT The speed dome integrate Sony camera block OSD into the speed dome OSD for other brands of camera block it will call up its own OSD menu for setting A AUTO FOCUS Switch Auto ML trigger function B DIGITAL ZOOM On off C BACKLIGHT When the light is dim please open the backlight compensation to make the imag
10. Economic Series Intelligent High Speed Dome Camera User s Manual CONTENTS 2 252 s ase e Reve 2 2 5 5255 4 Lesern 4 PZ PK TURP HC 4 TS atin ees EE ae at tent sae ao a p p T 5 CHAPTER 2 INSTALLATION AND CONNECT ION ccccccccccccccccccccccccccccccccccccccccccccccccccccecs 6 2 I OPPIONAT PARTS FOR TINS TALIA T LOIN sal eat loca uetus 6 ARNIN NR ORC ce 6 DS PREPARATION auo 6 LOTO c LR 7 ins ioni udo itta asl S 10 CHAPTER 3 SETUPS 14 3 1 HOW TO USE THE KEYBOARD CONTROLLER bee Uis vs dtu ESO e UR 14 3 2 SELF CHECKING 2 2 00 00 0 0 0 00000000000000004000 14 Rr NIB LS UM E TUM Pc CERE 15
11. N lt MOTION gt ADDR PRO BAUD ON RESTART lt DISPLAY POSITION gt FACTORY DEFAULTS HELP BACK EXIT E V EXIT S A DOME On off B PRESETS Off on 2 seconds 5seconds 10seconds C MOTION Off on 2 seconds S5seconds 10seconds D ZONES Off on 2 seconds 5seconds 10Oseconds E PAN TILT Off on 2 seconds 5seconds 10seconds F ADDR PRO BAUD On off address protocol baudrate G DISPLAY POSITION 18 09 gt A DISPLAY SETUP h DOME ON PRESETS 5 SEC MOTION 5 SEC ZONES ON PAN TILT ON ADDR PRO BAUD ON lt DISPLAY POSITION gt BACK lt EXIT D A DOME TITLE Use the joystick of the keyboard to move the dome title to the specified position on screen B ZONES Use the joystick of the keyboard to move the information to the specified position on screen C MOTION Use the joystick of the keyboard to move the Function Title to the specified position on screen D PAN TILT DISPLAY POSITION lt DOME TITLE lt ZONES gt lt MOTION gt lt PAN TILT gt BACK EXIT 4 Jawe Use the joystick of the keyboard to move the Coordinate Indication to the specified position on screen DOME SETTING 6 MAIN MENU LANGUAGE ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS BACK EXIT
12. PRIVACY MASK gt lt DOME SETTINGS gt lt PASSWORD gt lt CAMERA gt lt DOME TITLE gt lt OTHERS gt BACK EXIT 4 CAMERA SETTING AUTO FOCUS ON DIGITAL ZOOM BACKLIGHT ON FREEZE ON ZOOM SPEED LOW DAY NIGHT AUTO IMAGE ON lt ADVANCED gt BACK EXIT MOTION lt PRESET gt lt SCAN gt lt SEQUENCE gt lt PATTERN gt lt ZONES gt BACK EXIT 15 Menu Item Description LANGUAGE English Chinese optional SYSTEM INFORMATION Display system info Address Protocol Baud Rate Temperature Video Format DISPLAY SETUP Set the overlay characters on screen to show time and position information DOME SETTING Standby Operation Privacy Mask Clock Manual Limit Password Title Soft address CAMERA Set parameters for camera block MOTION Set Preset position Auto Scan Cruising Tour Pattern Tour Guard Auto tracking special camera block RESTART Reboot the speed dome FACTORY DEFAULTS Recover to factory default all setting will be lost HELP Display speed dome operation help information EXIT Exit speed dome menu NOTES The following operations in speed dome menu will be supposed to use keyboard controller It is similar if users are using DVR or other devices 16 LANGUAGE There are English Chinese for selection Use Command call 95 to open speed dome menu move the cursor to lt LANGUAGE gt press to
13. UENCE gt lt PATTERN gt lt ZONES gt BACK EXIT d A1 PATTERN NO WARNING ARE YOU SURE OK CANCEL PATTERN NO 1 TITLE PATTERN 1 START lt SET gt DELETE BACK EXIT a PATTERN 2 1 DI Move cursor to PATTERN NO and press to enter setting mode of pattern number move the joystick upward or downward to select number then press to confirm B1 TITLE Move the cursor to lt gt and press to enter the setting mode of PATTEN title CI START MOVE the cursor to lt START gt and press to start the current Pattern D1 SET Move the cursor to lt SET gt and press to enter pattern setting mode Then PRESS IRIS ON TO CONFIRM will appear on the screen Use the keyboard to do PTZ operation and press to confirm 2 d PATTERN PATTERN RECORDING PATTERN 1 START REMAIN 1 E lt SET gt doc ASEL DECE IRIS OPEN TO CONFIRM BACK EXIT E1 DELETE Move the cursor to lt DELETE gt and press to delete the current pattern PATTERN D a b PATTERN NO 1 WARNING TITLE START ARE YOU SURE lt SET gt DELETE OK CANCEL BACK EXIT E ZONES MOTION o o CES RES Ra PME EE EG ZONEISNOTSET Al ZONENO 1 EL BI
14. and efficient Focus Rotation speed auto match Support automatically adjusts PTZ s horizontal and vertical speed according to the focus close far which will make it easier for manual subject tracking Dome address setup Support 255 camera hardware address Set and call preset position Preset position is to store the present PTZ horizontal angle vertical angle and camera focus which enable the speed dome go back to the memorized position quickly when needed Use DVR or keyboard to call preset positions and there are 220 preset positions available Auto Scan The speed dome will run between set left and right border watching on a specified area The speed dome supports 8 auto scan Auto Cruising The speed dome support 8 cruising tracks each cruising has max 32 preset positions It enables the speed dome to switch between different preset position to have quick views on different areas Pattern Tour PATTERN Pattern tour function 15 to record all the running operation of the speed dome a time section including Pan Tilt running zooming and focus The speed dome support 4 group Pattern tours and each has up to 60 seconds record Privacy Mask Draw a black shield on the screen to protect confidential area in monitoring Guard Location Function With Guard Location function the speed dome will go back to set preset position after a period of vacancy Vacancy time 15 adjustable for users Running Direction Display Set Ture North
15. dome must be installed on a solid wall or ceiling bracket Please refer to installation instructions Please read these instructions before using the speed dome follow all instructions and attention to all the warnings Warning Please do not install near any heat sources such as radiators stoves or other heating device 2 Please use specified adapters Use other adapters may cause fire electric shock or product damage Wrong power connection may cause fire electric shock or product damage 3 Do not destroy the safety effect the polarized or grounding type plug Polarized plug has two lugs and one is wider than the other Grounding type plug has two ground sheets and a grounding pin Wide line or grounding type pin lugs are used to protect personal safety 4 Do not step on or squeeze the power cord and please pay special attention to protect plugs convenience outlets and equipment contact position Please use the manufacturer s recommended additional equipment or accessories Prohibition of simultaneous connections of multiple cameras to a single adapter and capacity overload of the adapter may cause abnormal heat and fire 7 Power cord should be firmly plugged into a power socket connection is not secure may 2 10 11 12 13 14 15 16 17 18 19 20 cause fire The speed dome should be installed firmly on the wall or ceiling Falling camera may cause personal injury Do not put the conductor
16. e bright D FREEZE On off E ZOOM SPEED LOW NORMAL HIGH 24 F DAY NIGHT Auto BW Color G IMAGE On off lt ADVANCED gt CAMERA SETTING E ADVANCED gt AUTO FOCUS ON WB AUTO 1 DIGITAL ZOOM ON RED GAIN 208 Bl BACKLIGHT ON BLUE GAIN 167 CI FREEZE ON EXPOSURE AUTO DI ZOOM SPEED LOW SHUTTER 1 50 El DAY NIGHT AUTO WIDE DYNAMIC ON FI IMAGE ON SSNR OFF Gl lt ADVANCED gt STABILIZER OPEN HI BACK BACK d J A1 WB AUTO MANUAL ATW INDOOR OUTDOOR B1 RED GAIN 0 255 C1 BLUE GAIN 0 255 D1 EXPOSURE Auto iris shut menu Choose shut to adjust shutter parameter choose iris to adjust Iris parameter choose manu to set both shutter and iris shutter and iris parameters are as below Shutter 1 2 1 6 1 12 1 50 1 100 1 600 1 1000 1 10000 Iris F1 6 F2 4 F4 0 F6 0 F8 0 F14 0 E1 SHUTTER 1 2 1 6 1 12 1 50 1 100 1 600 1 1000 1 10000 F1 WIDE DYNAMIC ON OFF NOTICE This item is only for the camera module with WDR function 25 G1 SSNR off low mid high H1 STABILIZER Off open hold MOTION Gi MAIN MENU N MOTION LANGUAGE ENGLISH D TA lt SYSTEM INFORMATION gt EAC AN B lt DISPLAY SETUP gt lt SEQUENCE gt lt DOME SETTINGS gt Po D Ci Inu ZONES E lt MOTION gt RESTART FACTORY DEFAULTS
17. e carton vertically and slowly otherwise it may lead to damage on camera 2 Please refer to chapter 2 5 Initial Settings for Dip Switch Settings 3 Point the gap at the waist hole and then use a cross screwdriver to install two stainless steel screws M4 x 6 Note Please protect the transparent cover 2 4 stainless steel screw 4 Thread the power cable video cable RS 485data cable through the bracket fix the speed dome with bracket and tighten 3 internal hexagon screws Cable out 5 Cable Connection out connect to monitor s L power cable AC24V red green mE Control cable 485 A Biblue 485A b ack 485B 6 Put the cables including power video cable RS 485 and ground line through the bracket Then fix the speed dome base and the bracket with 4 screws and lock with 8 plain cushion and nut Note The speed dome must be fully tighten otherwise it may fall down and cause personal injury For outdoor use please pay attention on veneer cracks and cable hole sealing to ensure waterproof Size of wall mount 242 00 Size of in ceiling mount Note The thickness of ceiling should be between 4 2cm to 0 8cm And the ceiling should support 20kg within 225mm diameter 2 5 Initial Setting Address Setting E series speed dome support protocol self adaptation function it is no need to set the protocol dip switch Please make sure t
18. e lightning arrester within 45 degrees 33 Appendix 2 RS485 General Knowledge 1 RS485 Basic Features According to the RS485 industry standard the resistance 15 1200 the maximal load capacity is 32 valid loads 2 RS485 transmission distance When using the FTP of 0 56mm 24A WG as cable according to the baud rate s difference the maximal transmission distance is as following 2400Bps 1800m 4800Bps 1200m 9600Bps When the cable is thin or EMI 15 strong or the there are too many other devices the transmission distance will be shorten 3 Connection and terminal resistance When arranging the wires the way of connection use the way of snakelike both of the ends must connect 1200 terminal resistance the simple connection is as the Chart 7 the distance 15 no longer than 7 meters Picture 2 CNN So B D Y AH B 1209 1200 Controller 14 2H 3H Picture 3 4 Problems in practical application In the practical application most of the clients use the star type as a connection mode however the terminal resistance must connect the two devices in a longest distance such as 1 and 15 as this kind of connection doesn t meet the requirement of RS485 industry standard it will cause the problems of signal reflex weaken the ability of anti inter
19. enter setting use the joystick of keyboard to select one language then confirm and exit MAIN MENU SYSTEM INFORMATION LANGUAGE SYSTEM INFORMATION DOMEID 001 A DISPLAY SETUP ADDRESS 011 B lt DOME SETTINGS BAUDRATE 9600 N 8 1 C lt CAMERA gt PROTOCOL PELCO P D lt MOTION gt lt OTHERS gt RESTART FACTORY DEFAULTS BACK HELP EXIT EXIT A DOME ID B ADDRESS C BAUDRATE D PROTOCOL lt OTHERS gt SYSTEM INFORMATION OTHERS DOMEID 001 w A ADDRESS 01 VERSION 36201 B BAUDRATE 9600 N 8 1 SET gt C PROTOCOL PELCO P lt OTHERS gt BACK EXIT BACK EXIT A TITLE B VERSION C lt SET UPBACK gt The function is designed for external EEP storage If external EEP is failed the program will use backup information to keep the speed dome working properly Press OK to backup It will not affect normal use of the speed dome 17 OTHERS nM URN c eU WARNING TITLE PELET 8 VERSION 36201 ARE YOU SURE SET gt gt EXIT DISPLAY SETUP MAIN MENU m 4 DISPLAY SETUP LANGUAGE ENGLISH DII SYSTEM INFORMATION PRESETS 5 SEC DISPLAY SETUP gt MOTION 5SEC lt gt gt PAN TILT O
20. ference and signal control In this case the RS485 divider 15 recommended it can change the star type to a new connection that can meet RS485 industry standard and improve the reliability of communication 34 158 Picture 4 Picture 5 RS485 common faults solution Phenomenon Possible reason Solution 1 Host machine speed dome s address and 1 Change the host machine speed dome s address Speed dome can take baud rate is not matching and baud rate to be the same self checking but can t be 2 RS485 s pole is reversed 2 Conversion the pole controlled 3 Cable loosen 3 Fasten the cable 4 RS485 is damaged 4 Use a new RS485 cable 1 RS485 s contact is poor 1 Reconnect the RS485 cable 2 One RS485 is damaged 2 Use a new RS485 cable 3 The distance between host machine and 3 Install terminal resistance Speed dome can t be controlled well speed dome is too far 4 Too many speed domes 4 Install RS485 divider 35
21. he 89 bit of SW2 is set to 1 all cases Use SW to set speed dome address Address setting adopts binary system the 8th bit is the highest the 1st bit is the lowest Total 255 dome addresses could be set 10 Note 1 Put the dial to and 1 means status and 0 means off status 2 Dip switch for protocol PELCO P supports maximum 255 dome addresses protocol PELCO D supports maximum 254 dome addresses 3 Protocol setting The speed dome support protocols PELCO P and PELCO D and 3 baud rate 9600BPS 4800BPS 2400BPS Protocol dip switch is bit 1 3 of SW2 ON OFF pe Notice The factory default protocol is PELCO D Baud Rate Setting Baud rate setting dip switch is bit 4 5 of SW2 and factory default is 2400bps 1 2 3 4 5 T 8 9600bps 4800bps Dome address code table under protocol TTANDY PELCO P Lp EN NEN BN Comparison chart of the PELCO D protocol address a a Chapter 3 Setups Connect the speed dome to control device keyboard controller DVR or software to adjust setting 3 1 How to use the keyboard controller Follow the steps below to do the setting 1 Call the preset position No 95 open the speed dome OSD 2 Use the joystick to set in the menu 3 Press to open the menu 4 Use the joystick to change chose
22. ight shifting on menu Appendix Appendix 1 Lightning and surge protection The outdoor speed dome need to have the function of lightning and surge protection in order to make sure that electronic components are safe please take the following measures The transmission cable must be keep 50 meters away from the high tension apparatus and high voltage cable It s better to arrange the outside cable under the eave In the open area the wire must be sealed by the steel tube and connect the earth by one end the way of overhead wire arrangement is forbidden In the strong lightening storm or high voltage areas the extra high power lightening protection device and lightning rod are needed The design of lightning protection must be matched with the building s lightning protection requirement and it needs to correspond requirement of the country and or industry standard The system must connect to the earth at ISO Electrical level The earth connection device must meet the requirement of anti interference and electrical safety and can t be short circuit or hybrid junction with the strong current When the system connects the earth the resistance l 2 is no more than 40 the cross sectional area is no less than 25mm The resistance of Video Lightning arrester Communication Lightning arrester Power Lightning arrester and Earth conductor is no more than 40 Steel jacket Lightning arrester Speed dome must be installed under th
23. n high humidity environments there may have moisture inside the dome cover Please clean with soft and dry cloth before reuse Please use the products in the working environment requirement Power supply AC24V 2 0A Communication Interface RS 485 Ambient temperature S35 653570 Environment Humidity lt 95 Atmospheric pressure 86 106KPa Chapter 1 Introduction 1 1 Introduction E series speed dome is a strong tool to improve your security effect It has the highest speed in the market 0 05 600 s to catch any target objects with elevation angle of 8 and auto flip to ensure all outdoor monitoring area 220 presets 8 auto scanning 8 cruising tracks and 4 pattern tours which meet all the security running operation requirements The soft address function will give you a new experience for address setting which will save a lot of time Remote update function will provide you quick response in maintainance job 1 2 Pictures Wall mount Installation In ceiling Mount Installation Wall mount bracket Wall mount bracket EE as Camera Module d ur Housing Ko Camera Module 1 3 Features OSD Menu Display the speed dome information and status setting for speed dome functions and features Soft Address With Soft address function users do not have to set on the speed dome dip switch and remember those complicate octal address It can be set in OSD menu from keyboard or PC software which make setup job easy
24. n parameters 5 Press to save all the changes on setting 3 2 Self Checking Information The speed dome camera will launch self checking operation after power on It will do horizontal movement first then vertical movement and finally camera block operations The starting up image will show self checking result information on the screen and last for 30 seconds Horizontal Movement The speed dome camera rotate in counterclockwise direction to the 0 position then continuous to go to the original position before power on Vertical Movement The speed dome camera moves downwards to 90 position of the horizontal direction then go upwards to the original vertical position before power on Camera Operation The camera block zoom in to the max distant then go back to the original zooming position SELF TEST INFO CAMERA ADDRESS PROTOCOL PELCOP BAUDRATE 9600 4 1 H LIMIT OK LIMIT MEMORY 14 3 3 OSD Menu Tree MAIN MENU DOME ID ADDRESS BAUDRATE PROTOCOL SYSTEM INFORMATION 011 9600 N 8 1 PELCOP MAIN MENU LANGUAGE ENGLISH SYSTEM INFORMATION DISPLAY SETUP gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT lt OTHERS gt BACK EXIT DISPLAY SETUP DOME 5 5 SEC MOTION 5 SEC ZONES ON PAN TILT ON ADDR PRO BAUD ON DISPLAY POSITION gt BACK EXIT DOME SETTINGS lt IDLE gt lt
25. ress to enter the setting mode of sequence title C1 START MOVE the cursor to lt START gt and press to start the current sequence D1 lt SEQUENCE SET gt Press to enter the sequence setting SEQUENCE b C SEQUENCE E SEQ 1 No PRESET INTERVAL TITLE SEQ I 01 002 03 START 02 003 03 SEQUENCE 5 gt 03 E DELETE 2 04 E 05 06 EDIT 01 0903 03 INS ME BACK EXIT 4 d Move the cursor to lt SEQUENCE SET gt and press to enter lt EDIT gt mode Move the joystick rightward or leftward to select item a When the icon of lt gt is on the item NO move joystick upward or downward to select one preset position for a sequence One single sequence supports 32 presets b When the icon of lt gt 15 on the item PRESET move the joystick upward or downward to select a specified preset to add in the sequence INTERVAL is the time interval between two presets in one sequence c When the icon of gt 15 on the item INS move the joystick upward or downward to select setting mode as insert ok and delete d Move the cursor to BACK or EXIT and press to quit the setting E1 DELETE Move the cursor to DELETE and press to delete the current sequence 28 4 SEQUENCE SEQ NO 1 TITLE SEQI START SEQUENCE SET gt DELETE BACK EXIT D PATTERN MOTION lt PRESET gt lt SCAN gt lt SEQ
26. t MOTION gt RESTART FACTORY DEFAULT HELP EXIT M 4 d Press to reboot the speed dome camera 3l FACTORY DEFAULTS LANGUAGE ENGLISH SYSTEM INFOMATION gt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULT HELP EXIT P Press to recover all the settings to the factory default Help and Exit MAIN MENU LANGUAGE ENGLISH SYSTEM INFOMATION gt DISPLAY SETUP lt DOME SETTINGS lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULT HELP EXIT WARNING ARE YOU SURE OK CANCEL 4 Click to get help information of shortcut Move the cursor to Exit press to exit from the menu Remark MENU OPERATION HELP I CALL PRESET 95 TO OPEN MENU 2 MOVE JOYSTICK TO SELECT MENU ITEM 3 IRIS OPEN TO ENTER EDIT MODE 4 MOVE JOYSTICK TO EDIT PARAMETER 5 IRIS OPEN CONFIRM BACK EXIT 1 The camera block such as Sony LG Samsung has their own OSD To its own OSD please click the Exit of the OSD or use command 96 to exit the OSD menu Command call 96 is unavailable for Samsung camera block 2 To support shortcuts the operation mode of joystick will be changed right direction means confirm left direction means cancel Focus near and Focus Far on the keyboard indicate the left and r
27. tle setting of scan path SCAN NO 1 TITLE SCAN I START lt LEFT LIMIT gt lt RIGHT LIMIT gt SCAN SPEED 20 BACK EXIT 4 CI START AUTO SCAN TITLE SET INPUT CAPS ABCDEFGHIJ KLMNOPQRST UVWXYZ OK CANCEL Move the cursor to lt START gt to start the current scan D1 lt LEFT LIMIT gt Move the cursor to lt LEFT LIMIT gt and confirm to start setting the left margin of the current scan Then PRESS TO CONFIRM will appear on the screen Move the joystick and press to confirm E1 lt RIGHT LIMIT gt Move the cursor to lt RIGHT LIMIT gt and press confirm to start setting the right margin of the current scan Then PRESS TO CONFIRM will appear on the screen Move the joystick to press confirm F1 SCAN SPEED Move the cursor to lt SCAN SPEED gt and press to enter the setting mode of scan speed Move the joystick upward and downward to select the speed scale press to confirm The speed scale ranges is between 1 30 C SEQUENCE 27 monon ko ccc M SEQNO 1 Al TITLE SEQI BI D ODE START SEQUENCE SET gt D1 lt PATTERN gt EE ZONES EXIT BACK EXIT A1 SEQ NO Move the cursor to lt SEQ NO gt and press to enter the setting mode of Sequence No move the joystick upward and downward to select number Then press to confirm B1 TITLE Move the cursor to lt TITLE gt and p

Download Pdf Manuals

image

Related Search

Related Contents

AQ6150 Getting Statrted Guide - Electro  Propane Floor Stripper Equipment    Digital switching Components from Mastervolt - Y    Manual de instruções  POWER SOURCE - ESAB Welding & Cutting Products  A Bidirectional Transformation between EMF Models and Typed  Scarica le Informazioni sulla guida (file PDF)  Koda User Manual  