Home

RNAS-1200 User`s Manual - Express Systems & Peripherals

image

Contents

1. LED Indicators LED Name LED Color Status LED Function Green System is ready Ready Blinking once per second Reset to default Off System is not ready Green blinking 100 Mbps Ethernet mode LAN 1 2 ma p off No Ethernet activity or operating at 10 Mbps Red This FLI 1200 is acting as the master FLI server Act off This FLI 1200 is not acting as master FLI server 2 3 FLI 1200 Series Detailed Hardware Description Real Time Clock The embedded FLI 1200 s real time clock is powered by a lithium battery We strongly recommend that you NOT replace the lithium battery on your own If the battery needs to be changed contact the Moxa RMA service team at http www moxa com rma about_rma aspx WARNING There is a risk of explosion if the wrong type of battery is used To avoid this potential danger always be sure to use the correct type of battery Contact the Moxa RMA service team if you need to replace your battery CAUTION Dispose of used batteries according to the manufacturer s instructions and be aware that local ordinances may require special handling as a hazardous substance 2 4 3 Hardware Setup In this chapter we show how to connect the FLI 1200 to the network and to various devices The following topics are covered in this chapter o m im m a Mounting the FLI 1200 on a Wall
2. Boo ES Q E IIA O 3 GND o_0 Bo gt Y 4 DI_1 po 6 DI_O 7 DI_SOURCE 8 FLI 1200 Series Hardware Setup Installing the FLI 1200 Wallmount Case An optional kit with metal wallmount case is available for the FLI 1200 The kit includes the case itself two long rails to replace the wallmount ears and two brackets plus four screws to attach to the top of the FLI 1200 Take the following steps to install the wallmount case Step 1 Remove the eight screws that fasten the wallmount ears to the RNAS 1200 Step 2 Use the same eight screws to attach the two long rails to the FLI 1200 The rails will run the length of the device Step 3 Fasten the brackets to the top of the FLI 1200 using the four screws provided FLI 1200 Series Hardware Setup Step 4 Align the rails with the tracks of the metal case and slide the FLI 1200 into the case Step 5 Fasten the case to the two brackets
3. 4 W e 24 VDC 13 2 W Standards and Certifications Safety UL 60950 1 EMC EN 55022 Class A EN 61000 3 2 EN 61000 3 3 EN 55024 Rail Traffic EN 50155 EN 50121 3 2 IEC 61373 Green Product RoHS CRoHS WEEE EMI FCC Part 15 Subpart B Class A CISPR 22 2008 Warranty Warranty Period 5 years storage drive not included Details See www moxa com warranty Note These hardware specifications describe the FLI 1200 unit itself but not its recommended accessories In particular the wide temperature specification does not apply to accessories such as power adapters and cables 1 3 2 Detailed Hardware Description In this chapter we introduce the hardware of the FLI 1200 including appearance product dimensions and LED indicators The following topics are covered in this chapter O Hardware Layout gt Front View gt Rear View O Dimensions LED Indicators O Real Time Clock a FLI 1200 Series Detailed Hardware Description Hardware Layout Front View LED Indicators LAN Port x 2 LAN1 LAN2 Act Ready Power Input 10 100 Mbps DC 24V Power Input Cy Rear View Reset to Default Button Resetj to Default Digital Input FLI 1200 Series Detailed Hardware Description Dimensions 286 1 11 26 252 9 92 235 9 25
4. Depp heien re e peas Pap o ensasecenesegechiacacegeaeanannstsciearers 3 2 Connecting t the DIPOrG s ticciccedve sie uti ccececaceececescessapeneetabneae sate sene nba geet bee aK week chi KK Erue rku eet ened naa 3 2 Installing the FLI 1200 Wallmount Case ocococcnnnconnnnncnnnnnnnonennncnnnnnnnenrnrnnenrnrnnrnrnrnnenrnennrnrnarnrnanarnrnenananns 3 3 1 Introduction Thank you for choosing Moxa s FLI 1200 industrial auto configuration server appliance system The FLI 1200 s auto configuration or other industrial applications are designed to make your operation more efficient In this manual we show you how to install the hardware so that users can easily start using FLI 1200 devices The following topics are covered in this chapter O Overview O Package Checklist O Product Features o Hardware Specifications FLI 1200 Series Introduction Overview Moxa s FLI 1200 is an industrial auto configuration server appliance designed to automatically configure and monitor various Moxa products used in harsh industrial environments The FLI 1200 has a fanless thermally efficient dust and water protected IP54 rated chassis This sealed enclosure protects the internal components from dust and splashed water In addition the FLI 1200 is compliant with EN 50155 covering operating temperature power input voltage power surges ESD and vibration ensuring that the FLI 1200 will operate reliably in the kind of temperature and vibrat
5. or Cabinet Connecting the Power Connecting to the Network Connecting to the DI Port Installing the FLI 1200 Wallmount Case FLI 1200 Series Hardware Setup Mounting the FLI 1200 on a Wall or Cabinet To mount the FLI 1200 to a wall or cabinet use the screws provided with the product to attach the mounting brackets to the FLI 1200 s housing as illustrated in the following figure AAA Screws Screws Connecting the Power The FLI 1200 can be powered by PoE Power over Ethernet through the Ethernet cable or by connecting it to a 24 VDC adapter Once the system is fully powered and initialized the Ready LED will light up Connecting to the Network The 10 100 Mbps Ethernet LAN ports use 4 pin M12 connectors PIN TX The diagram at the right shows the pinouts for these ports To connect to the network plug a 4 pin M12 Ethernet cable into one of the FLI 1200 s M12 Ethernet ports and then plug the other end of the cable into an Ethernet switch or router When the cable is properly connected the LEDs on the FLI 1200 s Ethernet port will light up indicating that a valid connection has been established TD RD o o TD e RD oona _ A Connecting to the DI Port Two DIs using M12 A coded connectors are located on the rear panel The pin assignments are shown in the following figure and table PIN DIO
6. FLI 1200 Series Hardware Manual First Edition November 2014 www moxa com product MOXA 2014 Moxa Inc All rights reserved FLI 1200 Series Hardware Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Trademarks 2014 Moxa Inc All rights reserved The MOXA logo is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these changes are incorporated into new editions of the publication Technical Support Contact Informatio
7. ion extremes common to rolling stock applications The FLI 1200 comes with Moxa s FLI technology which ensures that when any Moxa FLI enabled device is replaced or deployed you do not need to manually reconfigure the device The FLI 1200 s web based user interface makes it easy for users to manage the system and also monitor the status of any device under the control of the FLI 1200 The FLI 1200 is designed to provide a high level of redundancy For starters if one of the FLI 1200 s Ethernet connections fails the other connection can take over automatically In addition two FLI 1200s can be used in tandem so that if one of the FLI 1200s fails the other FLI 1200 will take over automatically and perform primary system functionality As you can see the FLI 1200 can help users maintain Moxa s products efficiently and effectively reducing maintenance costs and eliminating most human errors Package Checklist The FLI 1200 Series includes the following models FLI 1260 CT T Industrial auto configuration server appliance with 2 M12 10 100 Mbps PoE PoE LAN ports 40 to 70 C operating temperature conformal coating FLI 1260 T Industrial auto configuration server appliance with 2 10 100 M12 PoE PoE LAN ports 40 to 70 C operating temperature Each model is shipped with the following items e Wall mounting kit e Quick installation guide printed e Warranty card NOTE Please notify your sales representative if any of the above i
8. n Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 www moxa com su ort Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Table of Contents 1 SUMtrOGU tin oa eins ice siete ce seinen ite cee cease ees eice dees ee dee ce dele ee wee meee eee enedeneeemedeniedseessedsceccecedeees 1 1 A A i IC Ce 1 2 Package Checklist vive veapag dec vecucueven deus vecvavcveucdvc a A AR 1 2 PRO UEFA AU bret esichnansnanbuereueesteniacnianspenegeseidentanataeetsaniacutagaiegefacsiaasie sane ys 1 2 Hardware Specifications naaca a a a a a aaa aa aa e a a a a a 1 3 2 Detailed Hardware DeSCriptiOn cccccseeeeeeeeeeeeeeeeeeeeeeeeseeeeeeseeeeeesaseeeesaseeeesaseuseseueuseseueusaseueueaseusuensos 2 1 Hardware Layout O 2 2 ERE 2 2 RM o 2 2 E E T EE E A O A rene se daaemeeaiasanee 2 3 LEDO CAMS SS a A 2 3 A ARREA AET E E E A T 2 4 3 Hardware Setup cccccccceceeceeeeeeeeeeeeeeueeseeeuseeeeseseueesasaueesasaueusasaeeususeesesaseesuseuaususaeaususeuaususauauenseuaueaeonsues 3 1 Mounting the FLI 1200 on a Wall or Cabinet eee eee eee 3 2 Connecting the POW a riari tektites hci a walla ceria naitede tn AG gd ld 3 2 Connecting to the NCtwOrksrs vse cs nriran naani ka Taa Te Se
9. tems are missing or damaged Product Features e Marvell 1 0 GHz processor e Industrial auto configuration server appliance e 2 10 100 Mbps Ethernet ports for network redundancy e Compliant with EN 50121 4 and essential sections of EN 50155 e IEC 61373 certified for shock and vibration resistance 1 2 FLI 1200 Series Introduction Hardware Specifications Computer CPU Marvell 1 0 GHz 88F6281 DRAM 512 MB DDRII Flash Memory Onboard 2 GB USB DOM to store OS Digital Input Input Channels 2 source type Input Voltage 0 to 30 VDC at 25 Hz Digital Input Levels for Dry Contacts e Logic level 0 Close to GND e Logic level 1 Open Digital Input Levels for Wet Contacts e Logic level 0 3 V max e Logic level 1 10 V to 30 V COM to DI Connector Type M12 A coded female Isolation 3 kV optical isolation Ethernet Interface LAN 2 auto sensing 10 100 Mbps ports M12 D coded LEDs System LAN1 LAN2 Act Ready LAN 100M Link x 2 Physical Characteristics Housing Aluminum Weight 1 98 kg Dimensions 252 x 130 x 57 mm 9 92 x 5 12 x 2 24 in Mounting Wall IP Rating IP54 Environmental Limits Operating Temperature 40 to 70 C 40 to 158 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Anti vibration EN 50155 Anti shock EN 50155 Power Requirements Input PoE IEEE 802 3af PoE IEEE 802 3at or 24 VDC Power Consumption e PoE 14

Download Pdf Manuals

image

Related Search

Related Contents

Manual en PDF - electronicaflamagas.com  Airless Sprayer - WSB Finishing Equipment  ifrogz iPhone 3G & 3G[S] Luxe Lean  INSTALLATION - CONRAD Produktinfo.    FRANÇAIS  Concepts In Wood DR30-E Instructions / Assembly  c - ECOserviços  Sony VAIO VPCEA2JFX  Impex NS-40501E Owner's Manual  

Copyright © All rights reserved.