1. Refer to the illustration on the inside front cover of this manual 1 ARMED Indicator Red lluminated System Armed Extinguished System Disarmed Flashing Alarm Condition or Memory 2 AWAY Indicator Red lluminated System Armed in Away Mode Extinguished System Disarmed Armed in Stay Mode oe POWER Indicator Red Illuminated Mains Power is present Flashing Trouble Condition 4 10S816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 4 READY Indicator Green Illuminated System is ready to be armed 5 ZONE Indicators Yellow Illuminated Zone bypassed Extinguished Zone clear Flashing Zone violated or tampered 3 Programmable Functions Functions include Pe Pe kS Pe o o k ko ko o ko o ko Pe ko e Pe Quick Away Arm Quick Stay Arm Arm with Entry Exit or Follower Zones Violated Stay Arm Stay Arm and Go Forced Arm Push to Arm Siren Sound on Arm Disarm single toot arm double toot disarm Panic Alarm Fire Alarm Chime Zones Buzz Zones Zone Tamper Arm with Key Switch or Remote Control Arming the Control Panel 4 1 How to AWAY Arm USER CODE Leave via Entry Exit Zone Ensure that the READY indicator is illuminated If not check that a
2. Note Buzz zones will be shown by flashing indicators See Section 11 A Buzz zone cannot be selected as a Stay zone the Buzz status must be cleared first 5 Repeat step 3 until the selection of stay zones is completed 6 Press the key to exit the stay zone programming mode 10 3 How to Cancel Stay Zones 3 ZONE NUMBER x Select the required Stay Profile See 10 1 2 Hold down the 3 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is in the Stay Zone programming mode 3 Press the NUMBER corresponding to the STAY zone you wish to IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 19 cancel followed by the x key 4 The relevant zone indicator will extinguish 5 Press the key to exit the stay zone programming mode 11 Buzz Zones Violation of a buzz zone during Stay Arm Mode will cause the keypad buzzer to sound for a period of 30 seconds during which time a valid user code must be entered If a valid user code is not entered during this period the system will register an alarm condition This feature helps prevent unnecessary false alarms Note If an entry exit zone is programmed as a buzz zone violation of the entry exit zone when the panel is Stay Armed will cause the keypad buzzer to sound for the duration for the entry delay time This allows the User to re enter the premises and disarm the panel after a S
3. 5 for two seconds until the keypad buzzer sounds It is possible to STAY arm by holding down the 5 key until the keypad buzzer sound The panel will immediately arm into the stay mode without any exit delay 4 6 How to Stay Arm and Go Hold down the key 6 for two seconds until the keypad buzzer sounds This is a single key arm function which allows the user to STAY arm and leave the premises 1 Hold down the 6 key until the keypad buzzer sounds The keypad buzzer will sound for the duration of the exit delay Only leave via designated exit route 2 Atthe end of the exit delay the ARMED indicator will illuminate and the AWAY indicator will remain extinguished All stay zones will be bypassed IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 7 7 Key Switch or Remote Arming 4 1 Ensure that the READY indicator is illuminated before leaving 2 Leave and close the door remembering to lock 3 Activate the remote or the key switch 4 The alarm will arm in the away mode Note f aremote control is used it is advisable to have the siren toot on arm function enabled 4 8 Auto Arming The panel can to be programmed to automatically arm itself at a pre programmed time Should the premesis be occupied at the auto arming time a valid USER CODE entered during the pre arm delay will cancel arming The pre arm delay is signalled by an exit beep 5 Disarming the Co
4. Indicator Zone 1 Zone 2 Zone 3 oOo mM Zone 4 The total summed value is the number being displayed For example assume the following zone indicators are illuminated Zone 1 Zone 3 and Zone 4 The value equals the sum of the values displayed by zone LEDs 1 3 and 4 See table 3 below Table 3 Binary Representation 9 3 5 Menu 4 1 2 Zone 1 1 Zone 3 4 Zone 4 Total 13 User Code Properties Enter the User Program Mode as per steps 1 5 of Section 9 2 Press the 4 key followed by the key to select Menu 4 option The READY and ARMED indicators will flash simultaneously Enter the USER CODE followed by the x key The READY indicator will flash and the AWAY indicator will be illuminated The properties assigned to the USER CODE are displayed by the Zone indicators An illuminated LED indicates that a property is active for the USER CODE Refer to Table 4 for a list of USER CODE properties To select a user code property press the key which corresponds to that property followed by the x key The appropriate zone LED will illuminate To deselect a property press the corresponding key followed by the kl key and the LED will be extinguished IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 15 For example To enable a User Code to function as a duress code press the 2 key followed by the xl key The zone 2 LED will illumin
5. The IDS 816 utilizes a user friendly menu driven interface which allows the user to add modify or delete user codes See Table 1 below for a summary of menu options The menu driven interface is accessed by entering USER PROGRAMMING MODE Once in user programming mode it is a simple matter to add view edit or delete user codes When a new user code is added it is stored in the first available user slot Table 1 User Programming Options Menu Summary of Menu Options Menu 0 Allows for the addition of new user codes Allows editing of the user name displayed by LCD keypads Menun This menu is only applicable if LCD keypads are installed Menu 2 Allows editing ofa selected user code Note that the user code properties are not edited only the user code itself Menu 3 Allows viewing of the user code slot number for a selected code There are 32 available user code slots Wenus Allows editing of the user code properties for a selected user code This is a bit mapped menu See explanation below Allows the allocation of a selected user code to a designated Menu 5 partition s This is a bitmapped menu See explanation below Allows the deletion of a selected user code For this menu the user code must be known Allows the deletion of a user code using the user code slot number Menu 9 Menu 10 12 IDS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 9 2 How
6. is armed in the Stay Mode the preselected stay zones will be bypassed automatically The panel allows for two unique STAY PROFILES to be stored ASTAY PROFILE stores a preselected combination of STAY and BUZZ zones to suit a specific STAY ARM requirement If a partition is stay armed using Profile one it is possible to toggle the panel arm status directly to stay arm profile 2 by holding the 5 key for two seconds STAY and BUZZ zones can be programmed for each profile once the profile has been selected See section 10 and 11 18 IDS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 10 1 How to Select a Stay Profile MODE 2 PROFILE NUMBER Press the key to clear any previous entries Hold MODE down for one second until the keypad beeps Press the 2 key followed by the x key Press 1 or 2 for the required profile Press x to enter The buzzer will give a long beep Program STAY and BUZZ zones for the profile or ARM the profile See sections 10 and 11 dm m 10 2 How to Program Stay Zones 3 ZONE NUMBER x Select the required stay profile See 10 1 2 Hold down the 3 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is in the Stay Zone programming mode 3 Press the NUMBER corresponding to the zone you wish to be a STAY zone followed by the xl key 4 The relevant zone indicator will illuminate
7. of a bypassed zone is ignored and will not cause an alarm condition Once the system is armed it is not possible to bypass zones All bypassed zones will be automatically cancelled each time the panel is disarmed and must be re bypassed before the next arming 6 1 How to Bypass a Zone 4 5 Hold down 9 ZONE NUMBER x Hold down the 9 key for two seconds until the keypad buzzer sounds to enter bypass mode Press the number corresponding to the zone you need to by pass e g the 2 key if you wish to bypass zone 2 then press the key The relevant zone indicator will illuminate to indicate that the zone is now bypassed Repeat step 2 to bypass other zones Press the key to exit the bypass mode Note Panic Zones cannot be bypassed IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 6 2 How to Un Bypass a Zone Hold down 9 ZONE NUMBER x 1 Bypassed zones are shown by constantly illuminated zone LEDs 2 Hold down the 9 key until the keypad buzzer sounds to enter bypass mode 3 Press the number corresponding to the currently bypassed zone then press the x key 4 The zone indicator will extinguish the zone is now active 5 Press the key to exit the bypass mode 7 Emergency Alarms 7 1 Fire Alarms F Hold down the F key for two seconds until the keypad buzzer sounds If the F key is presse
8. only used in the unique situation where an intruder forces one to disarm the system under duress When a DURESS CODE is entered the control panel disarms normally however a DURESS ALARM CODE is reported to the monitoring company It is advisable to choose a Duress code that can be easily remembered by all family or staff members 8 Alarm Memory The Alarm Memory displays any zones which were violated or bypassed during the last arm cycle A flashing ARMED indicator notifies the user of an alarm memory condition To view the alarm memory disarm the panel and continue as indicated below To Display Alarm Memory 0 Hold down the 0 key for two seconds until the keypad buzzer sounds Hold down 0 until the keypad buzzer sounds 2 The READY indicator will extinguish and the keypad buzzer will sound briefly 3 Illuminated zone indicators show which zones were violated during the last armed period 4 Press 2 to display zones which were bypassed 5 Press 3 to display which zones were tampered IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 11 6 Press 1 to return to violated zones 7 The alarm memory is erased during each arm disarm cycle 9 User Codes The IDS816 Alarm Panel has 32 programmable user codes By default code one 1 is the Master User Code 9 1 Adding Deleting and Editing User codes bl MASTER USER CODE NEW CODE x
9. the siren Entering a valid User Code before the siren sounds will STOP the keypad buzzing and prevent the siren from sounding To provide greater flexibility the panel caters for two 2 different STAY PROFILES to be programmed Each STAY PROFILE contains a unique combination of STAY and BUZZ zones which cater for a particular STAY ARM requirement For example PROFILE 1 might be used when the family goes to bed in the evening whereas PROFILE 2 is utilized while they watch television See 10 1 How to Select a Stay Pofile 6 IDS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 4 4 How to Stay Arm USER CODE Do not leave premises 1 Select the required STAY PROFILE See Section 10 1 on page19 2 Ensure that the READY indicator is illuminated if not check that all protected doors and windows are closed and that motion has ceased in the areas covered by motion detectors 3 Press the key 4 Enter a valid USER CODE 5 DONOT open the front door If the front door is opened the system will arm in the AWAY mode 6 The ARMED indicator will illuminate and the keypad buzzer will sound for the duration of the exit delay 7 The AWAY indicator will remain extinguished 8 Any STAY zones shown by a steadily illuminated indicator will be automatically bypassed 9 Ensure that you enter only those areas that are bypassed 45 How to Quick Stay Arm Recommended method Hold down the key
10. ARMED AWAY and READY indicators will start flashing to show that the keypad is in the TROUBLE VIEW MODE Refer to the table 5 below to find the significance of each illuminated zone LED The system will automatically exit the TROUBLE VIEWING MODE after one minute To exit this mode press Note Certain trouble conditions cannot be cleared using the key They will only clear once the trouble condition has restored To simply cancel the beeping without viewing the trouble conditions press key 22 IDS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 Table 5 Trouble Conditions Indicator Trouble Condition 1 AC Mains Failure Failure to communicate successfully to monitoring company Phone line trouble Siren tamper Low battery Loss of Clock Timer Engineer Reset Box tamper n a Tamper on peripheral device O OMDINI ola BEM o Communication loss to peripheral device ae NM Loss of power to peripheral devices 14 Remote Telephone Access ThelDS 816 Alarm Panel has a secure remote telephone interface which allows a user to arm disarm to bypass unbypass zones andto set programmable outputs via a phone line A user accesses the remote dial in interface by dialling the alarm panel with a DTMF enabled phone To access the remote dial in interface dial the alarm panel and wait the number of rings programmed or use the f
11. ate to confirm the selection T Repeat step 5 until the desired properties have been programmed 8 Press the key to exit the User Program Mode Table 4 User Code Properties Zone LED Property 2 Duress Code 3 Arm to Disarm Code Maids Code 4 Global Arm Disarm Code 9 3 5 1 Duress Code Explanation of User Code Properties This is a special 4 or 6 digit user code which should only used in the unique situation where an intruder forces one to disarm the system under duress When the DURESS CODE is entered the control panel disarms normally however a DURESS REPORTING CODE is trans mitted to the monitoring company to inform them that you have been forced to disarm the control panel by an intruder Itis advisable to choose a code that can be easily remembered by all family or staff members 9 3 5 2 Maids Code The maids code may be used to limit access to the premises The maids code will only disarm the system if the same code was used for arming If armed with a code other than a maids code the system will view an attempt to disarm with the maids code as an invalid entry Any valid user code will disarm the system if it has been armed with the maids code EXAMPLE If a maid is expected on a Monday arming the system on a Monday morning using the maids code will allow the maid to disarm the system On days that any other user code i e not a maids code has been used to ar
12. ax defeat function The panel will answer and transmit download handshake tones consisting of a high frequency tone for two seconds followed by a lower frequency tone for one second Within twenty seconds of the panel transmitting the download handshake tones enter a valid user code on the DTMF enabled phone If a user code is not entered or if the user code is invalid the panel will release the line If the user code is valid and telephone access has been enabled the panel will give a single confirmation beep indicating IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 23 that the user has gained access to the remote interface If no key presses are detected for twenty seconds once access has been gained to the remote interface the panel will release the line Please refer to the table 6 opposite and select the required operation Note Onthe IDS 816 Alarm Panel PARTITION limited to 1 or 2 ZONE limited to 1 16 OUTPUT limited to 1 7 Any value outside of these constraints will result in a key entry error occuring 24 IDS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 Table 6 Remote Telephone Operation Operation Key Entry Panel Response Arm a Partition 1 1 PARTITION A Single Confirmation Beep indicates Partition armed successfully Three Error Beeps indicates Partition cannot be armed by user code or Partition not ready to be armed or a key entry error has o
13. ccured A Single Confirmation Beep indicates Partition disarmed successfully oe 3 1 2 PARTITION Three Error Beeps indicates Partition cannot be artition disarmed by user code or a key entry error has occured et Arm A Single Beep indicates Partition is Armed Status 1 8 PARTITION A Double Beep indicates partition is Disarmed By Partition Three Error Beeps indicates a key entry error Bypass a Zone 2 1 ZONE A Single Confirmation Beep indicates that the zone was successfully bypassed Three Error Beeps indicates that the zone cannot by bypassed or a key entry error has occured Un Bypass a Zone 2 2 ZONE A Single Confirmation Beep indicates that the zone was successfully unbypassed Three Error Beeps indicates that a key entry error has occured Test Zone Bypass Status 2 3 ZONE A Single Beep indicates that the zone is bypassed A Double Beep indicates that the zone is un bypassed Three Error Beeps indicates that a key entry error has occured A Single Confirmation Beep indicates that the Set programmable output was set P 1 TP i rogrammable 3 1 OUTPUT P Three Error Beeps indicates that a key entry error Output has occures Clear A Single Confirmation Beep indicates that the programmable output is clear P I 1 TP ii rogrammable EEE Three Error Beeps indicates that a key entry error Output has oc
14. cured A single Beep indicates that the programmable Test output is set es aT Programmable 3 1 OUTPUT A Double Beep indicates that the programmable Output Status output is clear Three Error Beeps indicates that a key entry error has occured Hang Up 0 Telephone Line Released Three Error Beeps indicates that a key entry error has occured IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 25
15. d until the keypad beeps approximately 2 second a FIRE ALARM condition will be activated The FIRE ALARM CONDITION can also be triggered by a smoke detector connected to an appropriately programmed zone The siren will sound and the FIRE REPORTING CODE will be transmitted to the monitoring company To silence the siren enter a valid USER CODE 7 2 Panic Alarms P Hold down the P key for two seconds until the keypad buzzer sounds If the P key is pressed until the keypad beeps approximately 2 second a PANIC ALARM condition will be activated APANIC ALARM can also be activated by any FIXED PANIC button or REMOTE PANIC buttons Ifthe audible panic option has been selected the siren will sound A PANIC ALARM will be transmitted to the monitoring company To silence the siren enter a valid USER CODE Press the P key only in an emergency situation that requires response by emergency personnel 10 1DS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 3 Medical Alarms M Hold down the M key for two seconds until the keypad buzzer sounds Ifthe M key is pressed until the keypad beeps approximately 2 second a MEDICAL ALARM condition will be activated The keypad buzzer will beep 5 times A medical reporting code will be reported to the monitoring company 7 4 Duress Alarms DURESS CODE This is a special user code which should
16. e DI z Z z IDS 7 Secur IDS816 User Manual MANUAL NO 700 283 01 B ISSUED DEC 2004 VERSION 2 00 Contents O EUBEWM VCOCOCECOCEECE NNNNN DDP MUM AAPPAPAAABP W N BEM hp NM t Go to bo w ho Oo KR wh IntroductiontothelDS816 4 Understanding the Keypad Indicators 4 Programmable Functions 000000000raneeenan 5 Arming the Control Panel 0 5 How To Away Arm 12141141114 die ani 5 HowToCuickAwayArm 6 Stay AKIMI D e derdimi sade liseli dala sayan delale ea ai 6 HowloSstayAm 7 How To Quick Stay Arm Recommended Method 7 HowloStayArmandGo 7 Key Switch or Remote Arming 8 Auto AN siesena tasaa a a aaa 8 Disarming the Control Panel 8 How ToDisarmwitihaUserCode 8 How To Disarm using a Key Switch or Remote 9 BYPASSING Zones v mx0111000 enne Sireni 9 How To Bypass a ZONDE sssri iini 9 HowlToUn BypassazZone 10 Emergency Alarms 00vneeaneeeraneeasananan 10 Fire AlAriMS ecceeecceeeeeeeeeceeeeeeeeeceeeseceeeeeeeseneeeeeeeeaas 10 FAIMIG ALAIN rae ilik sa akal 10 Medical Alai MS cars alada enik ala 11 Dur
17. e ZON S NEM ME M NE 21 12 1 HowToProgramChimeZones 21 12 2 HowToCancelChimeZones 22 13 Viewing Trouble Conditions 00 22 14 Remote Telephone ACCESS ccsssecsseeessenseseens 23 Tables Table 1 UserProgammingOptions 12 Table 2 Value Represented by each Zone Indicator 15 Table3 BinaryRepresenltation 15 Table 4 UserCodeProperties 16 Table 5 Trouble Conditions amenna sanli Keseler elei ekle 23 Table 6 RemotelelephoneOpertation 25 IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 1 Introduction to the IDS 816 The IDS816 a versatile microprocessor based eight zone alarm panel It has two partitions and can be expanded to sixteen zones Most features are programmable and may be programmed either directly through the keypad or via the telephone line using the IDS download software and modem There are eight programmable burglary zones monitored siren output auxiliary power outputs and five programmable outputs which may be programmed to perform various trigger switching functions For correct operation the IDS816 must be used with the specified transformer battery combination and appropriate peripheral sensors and signalling devices 2 Understanding the Keypad Indicators
18. ess ALARMS esa E acest 11 Alarm MGM Py sassiscsesncecnccsssanesenasicasecsersasaneceacccarereaee 11 User CODES isccccsecctncccsesacsesenccenscnccacadcrnacetanasedcererasecss 12 Adding Deleting and Editing User Codes 12 How to Enter the User ProgramMode 13 Menu0 AddaNewUserCode 13 Menut EditaUserName 14 Menu 2 Edit a Selected serCode 14 Menu 3 View a User Clode Slot Number 14 Menu 4 UserCodeProperiies 15 Duress Code Explanation of User Code Properties 16 2 IDS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 9952 Mads COG sessen ee eeseness 16 9 3 5 3 GlobalArm DisamM 17 9 3 6 Menu 5 Assign User CodetoParttion 17 9 3 7 Menu 9 Deleted User Code Code known 17 9 3 8 Menu 10 Delete a User Code Slot known 18 10 Stay ZONES cccccssecseseeeessseeeeseeneseeeessseneesesenensseneeees 18 10 1 HowToSelectaStayProfile 19 10 2 HowloProgramStayZones 19 10 3 HowloCancelStayZones 19 11 BUZZ ZOMCS EE GENE M NE 20 11 1 HowlToProgramBuzzZones 20 11 2 HowloCancelBuzzZones 21 12 Chim
19. ll be reported EXAMPLE You wish to know when someone enters or exits the front door the keypad will beep each time the door is opened if that zone is programmed as a chime zone 12 1 How to Program Chime Zones 2 ZONE NUMBER x _ Hold down the 2 key until the keypad buzzer sounds 2 The AWAY indicator will flash 3 To program a zone as a chime zone press the key corresponding to that zone followed by the x key The zone indicator will illuminate 4 Program any other zones you wish to select as chime zones as per step 3 5 Press the key to exit the chime programming mode IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 21 12 2 How to Cancel Chime Zones 2 ZONE NUMBER 4 Hold down the 2 key until the keypad buzzer sounds 2 TheAWAY indicator will flash 3 To cancel any chime zones press the key corresponding to that zone followed by the x key The zone indicator will extinguish 4 Press the key to exit the chime programming mode 13 Viewing Trouble Conditions Hold down the 7 key for two seconds until the keypad buzzer sounds The user is alerted to a trouble condition via a flashing power LED It is also possible to enable a trouble beep The keypad buzzer will sound to alert the user that a trouble condition has occured Press the key to stop the buzzer Hold down the 7 key for two seconds The
20. ll protected doors and windows are closed and that motion has ceased in areas covered by motion detectors If necessary close the front door IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 2 Press the key 3 Enter a valid USER CODE If an incorrect code is entered the keypad buzzer will beep three times Press the key and re enter the code 4 The ARMED indicator will illuminate and the keypad buzzer will sound for the duration of the exit delay Any bypassed zones will be shown by a steady illuminated zone indicator 5 Leave only via a designated exit route The panel will arm at the end of the exit delay 4 2 How to Quick Away Arm Hold down the 1 key until the keypad buzzer sounds If this function is enabled it is possible to AWAY arm by simply holding down the 1 key until the keypad buzzer sounds and the arming process begins Note Ifthe partition is already STAY armed this key will initialise AWAY arming It is therefore possible to change directly from STAY arm to AWAY armed 4 3 Stay Arming Stay arming allows the user to monitor selected perimeter zones and bypass interior zones The user can remain within the premises with access to designated areas during the STAY ARM cycle Any zone which may be violated accidentally should be programmed as a buzz zone When violated a buzz zone will cause the keypad buzzer to sound for thirty 30 seconds before sounding
21. m the system entering the maids code will not disarm the system 16 IDS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 9 3 5 3 Global Arm Disarm Code The code when entered will either arm or disarm both partitions depending on their status If both partitions are disarmed entering a global code will arm both partitions If both partitions are armed entering a global code will disarm them In the case where one partition is armed and the other disarmed entering a global code at the keypad of the armed partition will disarm that partition and entering a global code at the keypad of the disarmed partition will arm that partition 9 3 6 Menu 5 Assign User Code to Paritions 1 Enter the User Program Mode as per steps 1 5 of 9 2 2 Press the 5 key followed by the key to select Menu 5 options The READY and ARMED LEDs will flash simultaneously 3 Enter the USER CODE followed by the x key 4 The READY indicator will flash and the AWAY indicator will be illuminated 5 The partition that the USER CODE can arm disarm is displayed by the zone LEDs If zone LED 1 is illuminated the User Code can arm or disarm partition 1 If zone LED 2 is illuminated the User Code can arm or disarm partition 2 You can program codes to arm disarm both partitions 6 To select which partition the USER CODE can arm or disarm toggle zone LEDs by entering the ZONE LED NUMBER followed by the x key fs Repeat step 5 un
22. nly See manual supplied with the LCD keypad for an explanation of how to program Menu 1 9 3 3 Menu 2 Edit a Selected User Code 1 Enter the User Program Mode as per steps 1 5 of 9 2 above 2 Press the 2 key followed by the x key to select Menu 2 option The READY and Armed indicators will flash simultaneously 3 Enter the USER CODE which is to be edited f followed by the x key 4 The READY indicator will flash and the AWAY indicator will be illuminated 5 Enter the NEW CODE followed by the key 6 The READY and ARMED indicators will flash simultaneously 7 To edit other codes repeat steps 2 4 8 Press the key to exit the User Program Mode 9 3 4 Menu3 View a User Code Slot Number 1 Enter the User Program Mode as per steps 1 5 of 9 2 above 2 Press the 3 key followed by the key to select Menu 3 options The READY and ARMED indicators will flash simultaneously 3 Enter the User Code followed by the x key 4 The READY indicator will flash and the AWAY indicator will be iluminated 5 The USER CODE slot number will be displayed by the Zone indicators in binary format See table 2 6 Press the key to exit the User Program Mode Reading Binary Numbers To read a binary value on the keypad sum the values represented by each illuminated LED as shown in table 2 opposite 14 IDS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 Table 2 Value Represented by each Zone
23. ntrol Panel 5 1 How to Disarm with a User Code USER CODE To disarm the system enter followed by a valid USER CODE before the expiry of the entry delay 1 Enter the premises through a designated entry route Entering via any other route will cause an alarm 2 As soon as the entry exit zone is violated the entry delay will begin The keypad buzzer will sound for the duration of the entry period 3 Press the key and enter a valid USER CODE 4 Once the system disarms the ARMED indicator will extinguish and the keypad buzzer will stop sounding 5 If no valid user code has been entered by the end of the entry delay period an alarm condition will be registered 6 Ifthe entry period is too short have your installer change the entry delay period 8 IDS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 Note Ifa strobe or flashing light has been installed and an alarm condition is registered the strobe will continue flashing after the siren has stopped sounding Entering a valid USER CODE will cancel the strobe 5 2 How to Disarm using a Key Switch or Remote _ Activate the remote or keyswitch The system will disarm and the remote indicator if installed will extinguish If siren toot on disarm option is enabled the siren will give a double toot Bypassing Zones The term BYPASS is used to describe a zone that has been de activated i e violation
24. tay Arm and go 11 1 How to Program a Buzz Zone 4 ZONE NUMBER x Select the required Stay Profile See 10 1 2 Hold down the 4 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is ready to program buzz zones 3 Press the NUMBER corresponding to the zone you wish to be a Buzz zone followed by the x key 4 The relevant Buzz zone will be shown by the illuminated zone indicator Stay zones will be shown by flashing indicators A Stay zone cannot be selected as a Buzz zone the Stay status must be cleared first 5 Repeat steps 2 3 until all the required Buzz zones are programmed 6 Press the key to exit the buzz programming mode 20 IDS816 USER MANUAL NO 700 283 01B ISSUED DEC 2004 VER 2 00 11 2 How to Cancel a Buzz Zone 4 ZONE NUMBER x _ Select the required Stay Profile See 10 1 2 Hold down the 4 key until the keypad buzzer sounds The AWAY indicator will flash 3 Press the NUMBER corresponding to the BUZZ zone you wish to cancel followed by the x key 4 The relevant zone indicator will extinguish 5 Press the key to exit the buzz zone programming mode 12 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated the siren will NOT sound and no alarm condition wi
25. til all reguired partitions have been assigned to the User Code 8 Press the key to exit User Program Mode 9 3 7 Menu9 Delete User Code Code known 1 Enter the User Program Mode as per steps 1 5 of 9 2 2 Press the 9 key followed by the xl key to select IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 17 Menu 9 option The READY and ARMED indicators will flash simultaneously 3 Enter the USER CODE to be deleted followed by the x key 4 Further codes may be deleted as per step 2 above 5 After deleting the final code press the key to exit User Program Mode 9 3 8 Menu 10 Delete a User Code Slot known 1 Enter the User Program Mode as per steps 1 5 of 9 2 2 Press the 1 key then the 0 key followed by the x key The ARMED and READY indicators will flash simultaneously 3 Enter the SLOT NUMBER for the User Code you wish to delete followed by the key You can determine the slot number of a particular code by using Menu 3 4 Further User Codes may be deleted as per Step 2 above 5 After deleting the final code press the key to exit User Program Mode 10 Stay Zones Stay zones are those zones which are bypassed automatically when the system is STAY ARMED To avoid triggering the alarm zones such as bedrooms which are protected by Passive Infra Red PIR detectors must be bypassed Stay zones need only be programmed once Each time the system
26. to Enter the User Program Mode akon Hold down the key until the keypad buzzer sounds The ARMED and READY indicators will flash alternately Enter a MASTER USER CODE The factory default is 1234 Press the x key A valid entry will be confirmed by a long beep The READY indicator will flash If an invalid code was entered the keypad buzzer will give an error beep 3 short beeps Repeat steps 1 4 Select a menu option from Table 1 above 6 For example To add a new user code enter User Program Mode by completing steps 1 6 as listed above Enter 0 followed by a x key to access menu 0 Enter a NEW USER CODE followed by the x key Once the user code is programmed press the key to exit user program mode For a full list of programmable user code options refer to Table 1 Programing of these options is explained below 9 3 Explanation of Programming Menu Options 9 3 1 Menu 0 A Add a New User Code Enter the User Program Mode as for steps 1 5 of 9 2 above Press the 0 key followed by the x key to select Menu 0 option The Ready and Armed indicators will flash simultaneously Enter the NEW USER CODE followed by the x key further codes may be added as per step 2 above After entering the find code press the key to exit the User Program Mode IDS816 USER MANUAL NO 700 283 01 B ISSUED DEC 2004 VER 2 00 13 9 3 2 Menu 1 Edit a User Name LCD Keypads o