Home

User`s Instructions (Model WR-001)

image

Contents

1. if the Wall Dimmer receives another signal for timer operation the timer will start again and overrides the previous timer therefore extending the On period by another timer interval To stop timer count down press a programmed button for regular mode 5 REGULAR OPERATING MODE The Wall Dimmer can control the light in 2 different operating modes 1 On Off Mode Allows operating the light either on or off without dimming function 2 Dimming Mode Allows operating the light in on off or dimming dim brighten Light source must be either incandescent light or dimmable compact fluorescent light WARNING A Non dimmable load has to be always working under ON OFF mode Using non dimmable load under dimming mode may damage the non dimmable CFL The factory default operating mode is On Off mode However if your light is dimmable you may change the operating mode to Dimming Mode To change the operating modes please follow the instructions below 1 Turn on the light by the programmed transmitter or touch pad 2 Press and hold the button on the transmitter that is programmed to the Wall Dimmer in Regular mode for 10 seconds or touch the touch pad for 10 seconds with your finger 3 The light will flash If it flashes once that means it is in On Off Mode If it flashes twice that means it is in Dimming Mode 4 Repeating step 2 above will toggle the setting between On Off Mode and Dimming Mode 5 1 O
2. incandescent light or dimmable compact fluorescent light with a maximum load of 300W at 120VAC Light bulbs must be dimmable in order to achieve dimming function 2 Follow the diagrams below to install the Wall Dimmer with the 2 wires Live Load Use the provided wire nuts to connect these wires respectively to the existing wires from the wall Load red to load and Live Black to live Ground Green to Ground 3 After all the wires are connected ensure that all of the wire connectors are attached securely and there should be no exposed copper wiring Secure the Wall Dimmer with the provided screws 6 Place the air gap switch to on position The two blue LEDs will be on Note Ifthe 2 blue LEDs remain off please check and ensure the light bulb is installed and in good condition 4 Place the air gap switch to off position 5 Turn the circuit breaker back on 7 The light connected will be off The Wall Dimmer is now installed and you can tap the metal touch pad to turn ON OFF the connected light or to begin programming to learn transmitters into the Wall Dimmer Ground Usually copper or green Air Gap Switch Touch Pad Grey Antenna SET Do not cut the antenna Button Note Antenna grey wire Do not cut it keep it as straight as possible Put the antenna directly into the dry wall or through a hole of the metal box into the dry wall to get more control distance with a remote 3 PROGRAMMING
3. programming sequence Release the SET button if you are programming a transmitter to operate in On Off Mode Note Use a sharp non conductive object to press the SET button Changing the state of the load by the Touch Pad while pressing the SET button will interfere the learning process 3 If you are programming a transmitter to operate in Flashing Alert Mode continue to hold the SET button for about 10 seconds until the upper blue LED flashes slowly then release the SET button 4 If you are programming a transmitter to operate in Countdown Timer Mode continue to hold the SET button for about 10 seconds until the upper blue LED is on steadily on then release the SET button Upper LED Indication Flashes quickly Flashes slowly Operating Mode Regular Flashing Alert Countdown Timer Steadily On 5 Transmit a Learn code from the transmitter Refer to the manual of the transmitter to transmit this Learn code 6 Once the transmitter is programmed the both blue LEDs flash quickly then stops flashing You have successfully programmed the transmitter Note You must complete the programming sequence within the 15 second interval otherwise the Wall Dimmer will quit from programming mode and you need to start again from step 1 4 SET TIMER DURATION This section is for transmitters that are programmed for Flashing Alert Mode and Countdown Timer Mode The timer for both Flashing Alert Mode and Countdown Ti
4. ING TRANSMITTERS FROM THE MODULE You may erase a transmitter or sensor from the wall dimmer but you cannot erase a specific device directly you must erase all the wireless devices then program the ones you want to keep Follow the instructions below to erase programmed transmitters sensors 1 Power off the Wall Dimmer by placing the air gap switch to off position 2 Press and hold the SET button while holding the SET button slide the air gap switch to on position Note Use a sharp non conductive object to press the SET button Changing the state of the load by the Touch Pad while pressing the SET button will interfere the learning process 3 The blue LEDs will be on first then turn off 4 You may release the SET button now you have successfully erased all the devices 9 TECHNICAL SPECIFICATIONS Input Voltage 120V AC 60Hz Standby Current 0 2mA Minimum Load 10W Maximum Load 300W at 120VAC Operating Frequency 318MHz Operational Temperature 4 F 140 F 20 C 60 C Humidity 5 95 Range Up to 500 feet in open area 10 Wiring Diagram 13 CUSTOMER SERVICE If you would like to find out the up to date specifications Wiring Diagram know more about features and applications Wire colors may vary in the junction box download documents i e user s instructions order Skylink products or if you have difficulty getting products to work please 1 visit our FAQ section at www skylinkh
5. N OFF operation Use the Wall Dimmer To turn on off the light simply tap the touch pad of the wall dimmer once with your finger it will toggle the status of the light i e from on to off or from off to on Use a Transmitter Wall Dimmer allows on off operation when the programmed button is pressed it will transmit a signal to toggle the status of the load For example if a toggle signal is received when the light is off that signal will turn on the light 5 REGULAR OPERATING MODE CONT 5 2 Brightness control operation Besides turning on and off the light you may also control the brightness of the light if the light bulb is either incandescent light or dimmable compact fluorescent light Use the Wall Switch Turn on the light first Then keep touching the touch pad to change the brightness Remove your finger from the touch pad until the desired brightness is reached To change the brightness in the opposite way remove your finger from the touch pad and then keep touching again remove the finger from the touch pad until the desired brightness is reached Use a Transmitter First turn on the light Then press and hold the programmed button on the transmitter to change the brightness Hold the button until the desired brightness is reached then release the button Press and hold the same button again on the transmitter to change the brightness again in the opposite way When the desired brightness is reached relea
6. TRANSMITTERS SENSORS In order to operate the Wall Dimmer remotely with a transmitter or sensor it must be programmed to the Wall Dimmer Each module can be operated by up to 8 different transmitters or 8 different command signals There are 3 operating modes with the Wall Dimmer 1 Regular Mode When a valid signal is received it will turn on or off the light or change the brightness of the light 2 Flashing Alert Mode When a valid signal is received the light will flash for a specific period of time which is the time defined in the timer duration This works as an alert indication 3 Countdown Timer Mode When a valid signal is received the light will be on for a specific period of time 1 minute 5 minutes 15 minutes 30 minutes or 60 minutes This is mainly for energy saving You can program multiple buttons transmitters sensors to the module and different button transmitter sensor can activate a different mode To program a transmitter into the Wall Switch Dimmer follow the instructions below Before you program a transmitter to the Wall Dimmer decide the operating mode for this transmitter Regular Mode Flashing Alert Mode or Countdown Timer Mode 1 Wall Dimmer must be installed and powered properly Touch the touch pad The connected light should be on and the 2 blue LEDs are off 2 Press and hold the SET button for about 3 seconds the upper blue LED flashes quickly meaning it is in Regular Mode
7. Wall Dimmer Model WR 001 1 INTRODUCTION Thank you for your purchase of a SkylinkHome lighting receiver Wall Dimmer Model WR 001 Simply replace your existing wall switch with this Wall Dimmer you can then wirelessly turn on and off dim and brighten lights with a SkylinkHome transmitter The Wall Dimmer WR 001 can communicate with up to 8 transmitters so user has the option to add more transmitters to the system such as more remote controls or motion sensors etc All wireless signal communications within the SkylinkHome System are based on rolling code technology to ensure highest security is used The following items are included in this package Wall Dimmer Wire nuts User s Instructions Wall Dimmer WR 001 a P Wire nuts 2 SETUP Setup of the Wall Dimmer is simple Simply replace your existing wall switch by the Wall Dimmer CAUTION Installation is required and enclosed instructions must be followed carefully to all steps and notes If you are uncertain or uncomfortable performing this installation please consult a qualified electrician This manual should also be retained for future reference 1 Turn off power to the circuit that you plan on installing the Wall Dimmer to at the circuit breaker WARNING 4 amp Failure to turn off power at the circuit breaker can result in electrical shock causing severe or fatal injury Note Lighting Load The Wall Dimmer is designed to operate
8. ithin one year from date of purchase this product should become defective except battery due to faulty workmanship or materials it will be repaired or replaced without charge Proof of purchase and a Return Authorization are required FC c US LISTED CUSTOMER SERVICE 17 Sheard Avenue Brampton Ontario Canada L6Y 1J3 Email support skylinkhome com http www skylinkhome com P N 101Z713 004 Patent Pending 2010 SKYLINK GROUP
9. mer Mode can be set to the following duration meaning the light will stay on for the following time 1 minute 5 minutes 15 minutes 30 minutes or 60 minutes Only one timer interval can be set To set the timer duration follow the instructions below 1 Wall Dimmer must be installed and powered properly The connected light should be off and the 2 blue LEDs are on The light must be off in order to set the timer duration 2 Press and hold the SET button for 3 seconds the lower blue LED flashes once The number of flashes indicates the timer duration 4 SET TIMER DURATION CONT Note Use a sharp non conductive object to press the SET button Changing the state of the load by the Touch Pad while pressing the SET button will interfere the learning process Number of Flashes o o f em s f em r f om 3 Continue to hold the SET button until it reaches the desired setting The status will change every 6 seconds i e hold the SET button for another 6 seconds you will see the number of flashes changes from 1 to 2 2 to 3 etc Note Once the number of flashes reaches 5 it will stay at this setting If you would like to go back to other settings such as 1 minute release the button and repeat from step 1 to start over Once a transmitter button is programmed for timer mode or flashing mode activating this programmed transmitter button will turn on the light for the specified timer duration During a timer count down
10. ome com or 2 email us at support skylinkhome com or 3 call our toll free at 1 800 304 1187 from Monday to Friday 9am to 5 pm EST Fax 800 286 1320 14 ACCESSORIES The SkylinkHome System consists of many other devices such as SkylinkHome Remotes Motion Sensor ON OFF Wall Switch Wall Usually Black A Dimmer Plug In Dimmer with or without Repeater Plug In ON OFF a kai Control Outdoor Indoor Screw In Dimmer ON OFF Dimming Control ON OFF Control Smart Button Garage Door Control etc Please visit Skylink website at www skylinkhome com for more information Ground Green Ground Usually Copper Antenna Grey or Green Wire Wiring Diagram w o Neutral Wire Wiring Diagram Wire colors may vary in the junction box Neutral White Line Black GN Ne me A JA aya ae Load gt Usually Black r gt Red or Blue Ground Green Ground Usually Copper Antenna Grey or Green Wire Wiring Diagram with Neutral Wire 11 FCC The Device is approved by the FCC and it complies with Part 15 of the FCC Rules Its operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible of compliance could void the user s authority to operate the equipment 12 WARRANTY If w
11. se the button Refer to the user s instructions of the transmitter for more detailed instructions for dimming operation as well as other operations such as Zone On Zone Off Zone Dimming All On All Off etc Note Press and hold for more than 10 seconds will toggle the mode between ON OFF and Dimming Note If the 2 blue LEDs are off when the loading is off please check and ensure the light bulb is installed and in good condition 6 FLASHING ALERT OPERATING MODE If a Flashing Alert Mode transmitter or sensor is activated the light connected to the Wall Dimmer will flash for a predetermined time interval During the flashing interval the upper blue LED on the Wall Dimmer will flash the lower blue LED will start to flash during the last minute of the countdown timer Activating a programmed transmitter or sensor under Regular Mode or Countdown Timer Mode during flashing interval can override flashing alert operation 7 COUNTDOWN TIMER OPERATING MODE If a Countdown Timer Mode transmitter or sensor is activated the light connected to the Wall Dimmer will be on for the predetermined time interval During the timer count down the upper blue LED on the Wall Dimmer will be on steadily the lower blue LED will start to flash during the last minute of the countdown timer Activating a programmed transmitter or sensor under Regular Mode or Flashing Alert Mode during timer interval can over ride the countdown timer operation 8 ERAS