1. on the mounting position Install your blades and or blanking panels see Section 1 1 2 Connect the power cable to the rear of the unit s Lift the now populated chassis and bracket assembly into the rack at the desired level and attach with rack screws not provided 1 3 Hardware Inventory 1 2 3 4 AC power cord DC power supply Four rubber feet RS 232 console cable 1 4 Blade Installation and Removal Note Itis important that the module be properly aligned with the slot guides before it is inserted into the appropriate slot on the chassis It is recommended that the user s line of sight be level with the middle of the backplane in order to see both slot guides clearly Install a VSI blade into the chassis as follows Caution Use proper ESD precautions when installing or removing a VSI blade to avoid damaging the unit s circuitry Slide the blade open end first into the desired slot on the chassis until it plugs into the connector located on the backplane at the rear of the unit To insure that the blade is properly seated in the chassis and mated to the rear connectors push firmly on the blade s front panel Ensure that the front panel face is flush with the chassis ends and sides Note the red and black handle on the blade does not mount or lock to anything on the MPP200 chassis Tighten the captive thumb screw located at the top of the blade to provide a more secure mounting If desire
2. MPP200 User s Manual Status 1 m DCIN o aan lt la amp S 3 Status 2 Video 2 Visionary Solutions Inc M P P Video 1 m IP Media Processing Platform 2011 Visionary Solutions Inc All rights reserved Please visit the support section of our website at www vsicam com for manuals other documentation and software downloads Visionary Solutions Inc 2060 Alameda Padre Serra Suite 100 Santa Barbara CA 93103 T 805 845 8900 F 805 845 8889 www vsicam com July 10 2011 Revision 1 0 5 About This Guide VSI recommends that you download the most recent version of this Manual from www vsicam com Limited Liability In no event shall Visionary Solutions Inc be liable whether in contract tort or otherwise to OEM or Customers for a any damages resulting from loss of use data or profits howsoever arising hereunder in relation to or in connection with Visionary Solutions Inc Software b any special indirect incidental or consequential damages even if Visionary Solutions Inc has been advised of the possibility thereof Visionary Solutions Inc s total liability in contract tort or otherwise arising out of in connection with or in relation to the Software or otherwise under this Agreement shall be limited to the amount paid to Visionary Solutions Inc or and authorized Visionary Solutions Inc reseller for the Visionary Solutions Inc Software or Hardware for a Customer in the 12 month period immedi
3. ately preceding the event which has given rise to the liability The contents of this document are subject to revision without notice due to continued progress in methodology design and manufacturing Visionary Solutions Inc shall have no liability for any error or damages of any kind resulting from the use of this document Trademark Acknowledgements All trademarks or registered trademarks are properties of their respective owners Visionary Solutions Inc Limited 12 Month MPP200 Warranty We appreciate your purchase of this Visionary Solutions Inc product We feel confident that in normal use it will provide years of satisfactory performance Visionary Solutions Inc warrants to the original user that the video equipment supplied by us will be free of defects in materials and workmanship for a period of twelve 12 months from the date of purchase from Visionary Solutions Inc or an authorized reseller of Visionary Solutions Inc Visionary Solutions Inc s obligation under this warranty shall be to the repair including any necessary parts and the cost of labor connected therewith or at its option the exchange or the refund of the purchase price of any video equipment that is determined by us to have a manufacturing defect within the warranty period Replacement parts furnished in connection with this warranty shall be warranted for a period equal to the unexpired portion of the original equipment warranty Warranty Exclusions This
4. bligations The original dated bill of sale should be retained as proof of purchase and must be presented to the Visionary Solutions Inc or a Visionary Solutions Inc Authorized Service Center when this equipment is to be serviced under the provisions of this warranty The cost of transportation to and from the Authorized Service Center is the responsibility of the user How to Obtain Warranty Service Should this equipment require warranty service you may obtain specific information on how to obtain this service by directly contacting Visionary Solutions Inc or the reseller who sold you this equipment The MPP200 User s Manual 1 1 The MPP200 The Media Processing Platform MPP 200 is a high density blade chassis used in VSI IPTV applications It can be rack mounted in a 1U space or used as a stand alone Slots 1 and 2 on the chassis can be filled with any VSI blade product 1 1 1 MPP200 Front Panel Slots Blade Slots MPP200 lo T a 1 Visionary Solutions Ine O ellolfellelellellelleleleie G vsicam com g T O amp 1 1 2 MPP200 Rear Panel Status 1 O Video 1 0 Power O sue 0 Gs MPP200 Vidao2 O Visionary Solutions In IP Madia Processing Platform Status 1 Copies the status LED pattern of the blade inserted into Slot 1 For more information about the blade refer to the VSI User s Manual for that blade Video 1 Copies the video LED pattern of th
5. d an additional Phillips screw can be installed through the handle The Status LED will blink once a second when the blade is properly installed powered and operational To remove a VSI blade 1 Loosen the mounting screw at the top of the blade 2 If installed loosen the additional Phillips screw in the ejector handle 3 To pull the blade out of its slot and away from the chassis pull on the mounting screw at the top of the blade and on the handle at the bottom 1 5 Installing Blanking Panels After all blade options have been installed all empty slots must be populated with blanking panels Install blanking panels as follows Warning Failure to populate empty slots with blanking panels will negatively effect EMC radiation and immunity Note Blanking panels are used to cover each of the empty blade slots 1 Place the blanking panel onto the face of the MPP200 2 Tighten the two captive screws on the front of the blanking panel 1 6 MPP200 Safety and Compliance Unit Ratings A Caution 5Vdc 4A Power Supply Rating A Caution 100 250V 50 60 Hz 1 0A Fuse Rating No user accessible fuse Safety Approvals UL Listed I T E E257717
6. e blade inserted into Slot 1 For more information about the blade refer to the VSI User s Manual for that blade Power The Power LED illuminates green when power is supplied to the chassis Status 2 Copies the status LED pattern of the blade inserted into Slot 2 For more information about the blade refer to the VSI User s Manual for that blade Video 2 Copies the video LED pattern of the blade inserted into Slot 2 For more information about the blade refer to the VSI User s Manual for that blade 1 2 Rack Mounting the MPP200 Warning Before installing the MPP200 be sure to read the safety and equipment information contained in this chapter Caution Use proper electrostatic discharge ESD precautions when installing or removing the MPP200 to avoid damaging the unit s circuitry The MPP200 is designed to be rack mountable It is 5 7 inches wide and utilizes 1U of rack space when mounted Refer to the sections that follow for information on installing blades and blanking panels In order to install the MPP200 on a rack you will need an MPP200 Rack Mount Kit and a Phillips screwdriver The kit includes 2 small brackets 1 medium length bracket 1 long bracket and 10 screws The MPP200 Rack Mount Kit can mount one or two MPP200s in a 1U space and can be purchased online at www vsicam com 1 Locate and remove two pairs of screws from the chassis depending upon the desired final position of the chas
7. sis in the rack front or back For example to mount the chassis in the rack with the front facing out remove the pairs of screws left and right closest to the front of the chassis leaving the middle and back screws in place 2 Install one MPP200 chassis you will need one small bracket the long bracket and four screws from the MPP200 Rack Mount Kit a On the side of the chassis that is to be next to the rack sidewall attach one of the small brackets using the smaller holes on the bracket and the empty screw holes on the chassis Make sure that the larger holes on the bracket are flush with the face of the chassis b Attach the long bracket to the other side of chassis so that the longest face of the bracket is flush with the chassis front or back depending on the mounting position 3 Install two MPP200 chassis you will need two small brackets the medium bracket and eight screws from the MPP200 Rack Mount Kit a Attach a small bracket to each chassis so that the brackets are attached on opposite sides e g so that one chassis has a bracket on the left side and the other has a bracket on the right side using the smaller holes on the bracket and the empty screw holes on the chassis Make sure that the larger holes on the brackets are flush with the face of the chassis b Attach the medium bracket between the two chassis so that the longest bracket face is flush with the face of the chassis front or back depending
8. warranty does not apply to repairs or replacements necessitated by any cause beyond the control of Visionary Solutions Inc including but not limited to acts of nature improper installation misuse lack of proper maintenance accident voltage fluctuations and unauthorized repairs or modifications This warranty becomes void in the event serial numbers are altered defaced or removed Visionary Solutions Inc reserves the right to make changes in the design or make additions to or improvements upon this product without incurring obligations to install the same on products previously manufactured The foregoing warranty is in lieu of all other warranties expressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Visionary Solutions Inc neither assumes nor authorizes any person to assume for it any other obligations or liabilities in connection with the sale of its products In no event shall Visionary Solutions Inc or its authorized resellers be liable for special or consequential damages arising from the use of its products or any delay in the performance of this warranty due to causes beyond its control IN THE U S A SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS AND OR THE EXCLUSION OR LIMITATION OF CONSEQUENTIAL DAMAGES SO THE PREVIOUSLY STATED LIMITATIONS ON IMPLIED WARRANTY AND CONSEQUENTIAL DAMAGES MAY NOT APPLY TO YOU Customer O