1. Prefix suffix messages they consist of Date time message type prefix suffix and process data dimensions Date time consists of day month year hour minute second and milliseconds For P16 messages the milliseconds information is only to two decimal places the OP 2 inserts a blank For P32 there are four message types Alarm fault communications error and system error The P32 message system conventions display forms must be used For P 16 messages this information is not provided OP 2 inserts a blank Process data dimensions are optional information in a message and are just dependent on the configuring in SIMADYN D The configuring engineer on the SIMADYN D side decides when configuring the message system which format is displayed refer to Configuring Guides P32 and P16 communications for SIMADYN D The OP2 displays the messages configured in SIMADYN D as follows Possible message formats for P32 messages P refix s uffix Evaluation and display on OP2 ae Message is not administered The prefix is evaluated as message class If the message class is permissible the message is administered in the prefix suffix format notes Messages without prefix suffix with text are always administered in OP 2 yes yes The prefix is evaluated as message class If itis valid the message is administered in the text format Possible message formats for P16 messages P refix s uffix Evaluation and display on OP 2 po
2. 11 INITIALIZATION RUNNING OP2 waits for general INIT data OP 2 not ready if required check bus 2 2 1 configuration and configuring 1 18 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview 12 MEASURED VALUE INITIALIZATION OP2 waits for process data initialization OP 2 not ready if required check the bus configuration or configuring 13 BINARY VALUE INITIALIZATION OP2 waits for binary value initialization OP 2 not ready if required check the bus configuration or configuring NO MEASURED VALUE INITIALIZED No process data were initialized and configured the VAL function is not possible NUMBER OF LOST MESSAGES Message processing overflow message This message is entered as the latest message in the message buffer The oldest messages are overwritten by the latest messages The number of lost messages are counted until messages are deleted with DEL 17 NO FURTHER MESSAGES PRESENT The message buffer was scrolled past its end 0 RAM TEST UNSUCCESSFUL REPLACE OP2 electronically defective and not functioning S elf test message THE UNIT 1 FLASH TEST UNSUCCESSFUL OP2 electronically defective and not functioning S elf test message REPLACE THE UNIT 2 EPROM INCORRECT EPROM OP2 electronically defective and not functioning S elf test message CHECKSUM REPLACE THE UNIT 34 INITIALIZATION REQUESTED OP2 waits for initialization data 35 EPROM SAVE UNSUCCESSFUL Mode VAL CHG EPROM save unsucc
3. INITIALIZED The text is displayed until another basic function is selected Siemens AG 465 981 7101 23 Edition 02 96 1 3 SIMADYN D STRUC G User manual 1 Overview 1 2 3 Operator control overview of data processing 1 3 Binary value processing 1 3 1 Overview Up to 32 binary values can be processed BIN and B1 B4 The binary values cannot be stored in the SIMADYN D EPROM If this is required then a binary value must be configured in SIMADYN D as process data Binary value processing is realized in two ways SIMADYN OP 2 SIEMENS Processing the binary value menu Two line display binary values 5 32 Each line 40 characters e D e es es VAL SYS Q EREE v4 Processing the binary KEYS B1 B4 binary values 1 4 v5 6 m sji N o LIE v10 vil V12 Le JE fe 4 FIEIE JEE AGE 1 3 2 Processing binary keys B1 B4 Keys B1 B4 can always be selected unless system processing is selected SYSTEM The LEDs in the four binary keys indicate whether the corresponding binary value is 0 LED dark or 1 LED bright The status is inverted by depressing the key The LED flashes each time the KEY is depressed untilSIMADYN D acknowledges the change If the binary values are not configured on the SIMADYN D side then the LEDs in keys B1 to B4 remain dark i e the keys have no effect 1 3 3 Operator control overview for
4. cables The following dimension diagram shows an individual labeling strip and the visible fields which can be used for labeling 88 3x 16 7 50 1 16 7 2 5 14 2 When producing your own labeling strips according to the dimension drawing above it must be ensured that the material thickness does not exceed 0 1 mm Siemens AG 465 981 7101 23 Edition 02 96 SIMADYN D STRUC G User manual
5. fe Message is not administered The prefix is evaluated as message class If the message class is permissible the message is administered in the prefix suffix format Example for P16 message text 54321 12345 Messages without prefix suffix but with text are always administered in OP2 Example for P16 message text motor with overcurrent yes only The prefix is evaluated as message class If itis valid the message is prefix administered in the text format Otherwise it is rejected Example for P16 message text 54321 motor with overcurrent 1 6 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview 1 4 4 Description ASCII text message If there is a process data with dimensions included in a message then the OP 2 cuts the message text after 28 characters if itis longer than these 28 characters independent as to whether a dimension is included or not If there is no process data included the message text may be 56 characters long or the rest is rejected by OP 2 If the message text is shorter than the maximum length then the remaining characters are filled with blanks i e the display remains dark at these positions Thus the following message format is obtained at the display 2x40 characters d day m month or minute y year h hour z milliseconds T message type alarm fault etc 1 P32 message with process data and dimension maximum 28 message tex
6. is not sending 2 CIRCULATION SCAN telegram with the OP node number 2 3 2 3 2 3 1 2 3 2 3 2 2 2 1 4 6 2 3 2 Operating messages Information texts alarms and fault error messages are displayed for approximately three seconds as operating messages in order to help the user when problem situations occur Text Description Cause Measures Reference Section MEASURED VALUE NOT INITIALIZED A process data number V1 V24 was selected which was not configured in SIMADYN D FUNCTION NOT PERMITTED Function not permitted in the current processing mode 3 UPPER LIMIT EXCEEDED When entering or changing a setpoint the configured upper limit was 1 2 exceeded LOWER LIMIT FALLEN BELOW When entering or changing a setpoint the configured lower limit was fallen below 1 2 SETPOINT CHANGE INHIBITED When selecting the change mode for a process data the change was not enabled by SIMADYN D It is presently occupied changed by another OP or was configured as ACT value LAST CHANGE STILL NOT ACCEPTED The last process data change was not accepted by SIMADYN D Repeat the 1 2 function or check the configuring 7 1 2 DELAY TIME EXPIRED The actual change of a process data was still not accepted by SIMADYN D The monitoring time has been exceeded Repeat the function or check the configuring 8 FUNCTION NOT POSSIBLE A key was depressed which was not possible in the current processing mode INCORRECT INPUT An invalid value was entered
7. they have been received in OP2 refer to 1 5 2 PRINT MESSAGE DIRECTLY YES NO If YES is entered then messages are printed out as soon as the message telegram has been received With this type of print out there is not guarantee that the messages will be printed out in the sequence in which they were received Siemens AG 465 981 7101 23 Edition 02 96 1 9 SIMADYN D STRUC G User manual 1 Overview 1 5 System operation In system operation the basic settings operating parameters are defined for the OP2 The settings are permanently stored in the FLASH memory J Selection Depress the SYSTEM key for longer than 3 seconds 1 5 1 Function overview The following menu appears in the system mode MESSAGE VALUE USS INTERFACE PRINTER END DISPLAY OPTIONS Operator control CURSOR a Function selection zal Function start Function MESSAGE Parameterization for the message system processing refer to Section 1 5 2 VALUE Parameterization for data processing refer to Section 1 5 3 USS INTERFACE Parameterization of the USS interface to SIMADYN D refer to Section 1 5 4 PRINTER Parameterization of the printer interface refer to Section 1 5 5 DISPLAY OPTIONS Language selection for all OP 2 messages refer to Section 1 5 7 1 5 2 Parameterization for message system processing 1 5 3 Parameterization for process data 1 10 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview 1 5 4 Paramete
8. 1 Overview 1 Function description 1 1 Function overview The OP 2 is an operator control device for the SIMADYN D system It offers the following performance scope Siemens AG 465 981 7101 23 Edition 02 96 1 1 SIMADYN D STRUC G User manual 1 Overview Data processing referto Section 1 2 VAL Displays and processes up to 24 pieces of process data 2 pieces of process data are always displayed Binary value processing refer to Section 1 3 Displays and processes up to 32 binary values Message system refer to Section 1 4 Autonomous message system for P16 and P32 messages Messages are stored sorted according to the time that they were received and can be deleted and printed Only one message is displayed at any one time max 80 characters SYS System message refer to Section 3 MSG System operation refer to Section 1 5 aie Changes and stores and basic function SIEMENS SIMADYN OP 2 Two line display 40 characters per line sys SYSTE seer MSG BS v10 HRR ENEE HEE Bae ale Bi V12 Hi oO BG Numerical block Process data panels V1 V12 Binary value keys B1 B4 1 2 Data processing Data processing is selected using the VAL key If data processing is selected then the LED keys are lit of the VAL key 1 2 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview 1 2 1 General information Two of a total of 24 pieces of pr
9. D IMENSI 0 4 P16 message without process data tt mm jj hh mm ss zz PASTAT A al S22 645 24 wl Example for a P16 message in the prefix suffix format without measured value 12 06 94 14 33 24 98 P 32 9 TS 1 1 4 6 Message output on a printer The message format at the printer is defined by the OP 2 so that 2 display lines i e a complete message are combined to form a printer line Thus OP2 automatically includes a line break after every message Thus a message atthe printer is always 80 characters long the printer character length should be appropriately set The message structure is not changed by OP2 Example for a message print out Characters 1 40 Characters 41 80 Narre ER EELGGGECEAGGKGGGEGEREGLGEGEGEREGLEGEEGEREELERR 11 10 94 571 W MOTOR NO 4 RPM 999 121234567E 01 RPM 1 4 6 1 Initiating a print out The usercan print out all messages with the PRINT OLD orPRINT ACT keys the two keys must be simultaneously depressed For OLD PRINT all messages including the just displayed message are printed out For ACT PRINT that message is printed out which is presently being displayed The messages are not automatically deleted after the print out Messages are only deleted via the DEL key 1 8 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview 1 4 6 2 Automatic printing When parameterizing OP 2 it must be specified whether messages should be printed out immediately after
10. SYSMSG key starts to flash The message can be displayed with the SYSMSG key All of the error messages and the associated counter measures and error causes are described in the following The errors faults cannot be acknowledged The cause must be removed otherwise fault free operation is not possible Function selection Scroll through all active messages If no message is active Message display No 19 NO SYSTEM ERROR Running functions are ABORTED Only possible after the INIT phase No function These are the system messages Text Description cause measures Reference Section 10 INITIALIZATION ERROR MEASURED Error for an INIT telegram for process data R epeat initialization Check the 2 2 1 VALUE NO configuring NO PRINTER BUFFER FREE The printer cannot print out the message fast enough Messages are lost 1 4 6 Check the printer and printer connections NO SYSTEM ERROR System operation No error messages are active DATA TRANSFER ERROR CHECK Data transfer errors occur on the USS bus HARDWARE Disturbances faults on the line Incorrect baud rate BUS conflict on the USS BUS Defective bus cable Siemens AG 465 981 7101 23 Edition 02 96 1 17 SIMADYN D STRUC G User manual 1 Overview SYSTEM ERROR Unit not functioning F atal electronics fault 25 INIT ERROR NO MEASURED VALUE INIT Process data initialization incomplete OP 2 expects additional process 2 3 DATA initialization data OP2 is not read
11. age which result from using self assembled cables or cables from other manufacturers 2 E General v 24 TTY Shield Assignment SS 1 and SS 2 A opis RxD TxD CTS TxD TxD Shield RxD OOAYDUBWNrH 20mA 10 20MA 11 Nb 4 9 Labeling and replacing the labeling strips The OP2 function keys are labeled when supplied with B1 to B4 and V1 to V12 A set 4 of unlabeled strips are provided with the OP 2 for your own key labeling When used they cover over the standard labeling CAUTION Before attaching the labeling strips the labeling must be absolutely non smearable as ink smeared on the inside of a membrane keyboard cannot be removed The front panel can only be replaced in the service workshop at a considerable cost If required remove all of the old labels at the tabs Insert the labeled strips non smearing labeling cautiously to their end stop until they cannot be inserted any further Lower unit side SS1 F1 SS2A IF2A SS2B IF2B CO e e eos ATLL h For already installed OP 2 units it is recommended that the screw tensioners are loosened and the unit cautiously pulled forward out of the mounting cut out 1 24 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview Caution It is not permissible to hang an OP 2 by its connecting
12. and cable The connection is realized through the 9 pin sub D connector with the following circuitry A Circuit configuration as node at the center of the bus 9 pin Sub D A B Circuitry as node at the end of the bus with bus termination 9 pin Sub D 4 8 Printer operation at the OP2 4 8 1 Printer configuration The OP2 printer interface at the unit can be parameterized in two settings 1 XON XOFF protocol formatted message texts are transferred to a printer whereby the formatting is executed by OP2 2 XON XOFF protocol with ETX ACK formatted message texts are transferred to a printer whereby formatting is realized by the OPP2 OP2 transmits an ETX end of text after every message which is then acknowledged by the printer with ACK acknowledge e g Mannesmann Tally printer Only then can be the OP2 transmit a new message 4 8 2 Printer connection A printer is always connected at the SS11 interface of the OP2 Pre assembled cables are available for the following Siemens printers DR210 N DR211 N DR230 N DR231 N 6XV1 440 2B for TTY transfer 6XV1 440 2C for V 24 transfer length code refer to Catalog ST80 Siemens AG 465 981 7101 23 Edition 02 96 1 23 SIMADYN D STRUC G User manual 1 Overview These cables can also be used for PT 88 89 90 printers It may be necessary to assemble cables for other printers u2 SIEMENS AG does not accept any liability for incorrect functions and dam
13. binary value processing 1 4 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview Display Designator configured in SIMADYN D Default designation SIGNAL No SIGNAL9 SIGNAL10 SIGNAL11 SIGNAL 12 Status display as display 0 1 as text alternative configurable text if not configured Change Select the next or previous 0 1 changeover binary value The status display flashes after each actuation until SIMADYN D acknowledges the change Running functions are ABORTED No function 1 4 Message system processing The OP2 gathers all of the incoming messages into its own message system where up to 30 messages can be administered stored If more messages are received then the first messages are overwritten ring buffer mechanism and an overflow signal is entered into the buffer memory Operating message No 15 MESSAGE LOST QUANTITY xx xx specifies the number of messages which were overwritten Only one message can be displayed at any one time OP 2 chronologically sorts all of the received messages 1 4 1 Evaluation of message class areas An OP2 must not administer all messages which are sent from SIMADYN D Message classes are assigned as selection criteria as to which messages should be administered by an OP2 These message classes must be specified when parameterizing the OP 2 All messages can be permitted or one two or three message class areas refer to Secti
14. cable 2 1 Run up 2 1 1 OP2 firmware release message The following message appears for approximately 5 seconds after the unit has been powered up OP2 version V1 0 the actual firmware release is displayed 2 1 2 Hardware test The OP2 then automatically runs through a hardware test The following messages are displayed in the sequence during the run EL OM ok Faut gt EPROM memory failure gt OP2 defective replace PAN ok Faut gt RAM memory failure gt OP2 defective replace FLASH TEST Faut gt FLASH memory failure OP2 defective replace Fault gt FLASH memory erased Faut gt Incorrect FLASH memory checks Incorrect contents checksum of the flash memory FLASH is being re initialized FLASH TEST Start with DEFAULT initialization TEST ok The unit then automatically establishes a connection to SIMADYN D 2 2 Establishing the connection to SIMADYN D After a successful OP 2 self test the connection is established to the SIMADYN D racks The connection can either be initiated from SIMADYN D or from OP2 For SIMADYN D After a reset or the rack power supply has been switched on OP2 After the OP2 power supply has been switched on or optionally when the system mode is exited for the menu item INIT REQUEST in the END main menu Siemens AG 465 981 7101 23 Edition 02 96 1 15 SIMADYN D STRUC G User manual 1 Overview 2 2 1 Establishing the connection s
15. equence The OP 2 displays the start of the connection with the following message in the upper display line INITIALIZATION REQUESTED The process value is automatically initialized after the firstinformation is exchanged with SIMADYN D message in the upper display line PROCESS DATA INITIALIZATION and then the binary value initialization message in the lower display line BINARY VALUE INITIALIZATION If all of the initialization data have been completely loaded into the OP2 then OP2 automatically goes into the process data display mode refer to Section 1 2 The OP2 remains at the particular initialization step as long as this hasn t been completed The time to establish a connection can take up to a minute depending on the particular configuring It is only possible to start establishing a connection after the SIMADYN D rack has run up If an attempt is made to select the operating modes process data or binary values display while a connection is being established then OP 2 ignores this attempt However received message telegrams are processed 2 2 2 Errors when establishing a connection If faults occur when a connection is being established an appropriate system message is generated and the LED on the SYSMSG key starts to flash The message can be read out by depressing the SYSMSG key OP2 waits until the fault has been removed The following faults can occur No activity on the USS bus system message S24 This m
16. essage is set once when OP2 starts and then disappears as soon as the first telegram is transmitted along the bus f SIMADYN D racks are not switched on or don t run up f BUS connection not available or faulted cable not inserted f Incorrectly set baud rate No SCAN telegram with the node number of the OP2 after the protocol monitoring time expires system message S25 f Incorrectly set bus address in the OP2 refer to Section 1 5 4 f Incorrect configuring in SIMADYN D Transfer error system message S4 This message only appears until a correct telegram is received f Disturbance fault on the line incorrect baud rate Erronous INIT data The received data are logically incorrect f Fault disturbance on the line incorrect baud rate f Check the configuring The faults errors must be removed Re initialization of the OP 2 can be requested via the system mode 1 16 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview 3 OP 2 fault handling OP2 can identify two types off fault messages System messages The messages can be analyzed using the SYSMSG key refer to 3 1 Operating messages The messages are displayed for approximately 3 seconds and they then automatically disappear refer to 3 2 3 1 System messages If the OP 2 identifies an error fault during parameterization initialization or in cyclic operation an appropriate error message is entered in the system error field and the LED in the
17. essfu Check the configuring Self elf gt N N N i i E 3 38 39 7 1 FLASHRAM READ WRITE TEST Self test message TEST OK Self test message gt N Siemens AG 465 981 7101 23 Edition 02 96 1 19 SIMADYN D STRUC G User manual 1 Overview 4 Technical data 4 1 Front panel The OP2 has a two section aluminum housing consisting of a cast housing frame and a rear cover panel The degree of protection at the front is IP 65 and at the rear IP20 The OP 2 is ventilated through ventilation slots in the upper and lower side of the housing The housing frame consists of Insertable labeling strips to label the function keys The glued in front panel with membrane keyboard and LEDs Housing frame CesT FHHAHHHAAAAAYA AARAAR LSIMADYN OP 2 SIEMENS Two line display Each line 40 characters Ba Jor om Pens aa BRE Bi pt e Ss lt Ss lt m N i s a N gt m o ui N Membrane keyboard ir 4 2 Equipment dimensions and mechanical installation r og al A H H y L le 240 si ig 229 si Tt o The OP2 can be mounted in cabinets or desks Mounting cut out 230 x 158 mm Mounting depth 40 mm Max front panel thickness 16 mm 1 20 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview mw When installing the OP 2 the followi
18. ested using a short circuit plug The short circuit plug is assigned as follows Siemens AG 465 981 7101 23 Edition 02 96 1 13 SIMADYN D STRUC G User manual 1 Overview 5 General v 24 TTY Shield Assignment SS landSS 2A RxD TxD I CTS TxD TxD gt Shield RxD RTS 20mA GND GND 20mA 10 5V 11 GND WOONANDUBWNEFE The test is terminated with ENTER Hardware OP2 tests the internal memory OP2 displays the operating status in the upper display line RAM EPROM FLASH TEST The actual test step is displayed in the lower line If a fault is present OP 2 remains at the appropriate test step with the message TEST ERROR Foran error free testsequence the OP 2 automatically returns to the self test menu after the test has been completed The test takes approximately two minutes Message texts during the test run WRITE READ TEST OF RAM CALCULATE CHECK SUM OF EPROM WRITE READ TEST OF FLASH END End of the self test and a return to the SYSTEM mode 1 14 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview 2 System start The OP2 is switched on by switching in the 24 V power supply voltage All connections must be correctly connected up to ensure perfect functioning of the unit USS connecting cable to SIMADYN D Printer cable if the printer is connected Power supply
19. isplayed in the upper line USS INTERFACE TEST gt ENTER FOR END After the end of the test the following message is displayed in the lower line USS INTERFACE OK or USS INTERFACE ERROR the test is terminated with ENTER In the case of the last mentioned error message the two following steps are executed for further diagnostics Step 1 Test without the bus connector inserted this checks the USS bus interface of the OP 2 The OP must be replaced if a fault is identified Step 2 Test with the bus connector inserted It is not permissible that the bus master is active check the BUS wiring The wiring is incorrect damaged if a fault condition is identified KEYBOARD TEST In the keyboard test all key actuations are individually displayed If keys with LEDs are depressed then the assigned LED is simultaneously lit When the keys are actuated the particular descriptive text is displayed in the first line When simultaneously depressing two keys exception BIN and VAL the DOUBLE KEY message is displayed The test is terminated by simultaneously depressing the BIN and VAL keys Possible faults when depressing a key a message does not appear gt key defective when depressing a key the DOUBLE KEY message is displayed gt keyboard defective The OP must be replaced if a fault condition is identified PRINTER INTERFACE TEST A test telegram is output to the printer via the printer port The printer port can be t
20. ng points must be observed S S Sufficient space must be provided below the installation cut out for connectors which extend out when using standard cables at least 20 mm Ensure that the sealing gasket is correctly located The tabs of the labeling strips mustn t be clamped in The air ventilating slots of the housing rack mustn t be covered over by the installed equipment The OP2 must be protected from direct solar radiation Installation measures Insert the unit in the prepared cut out and ensure that it doesn t fall out until it is retained in place The labeling strip tabs mustn t be clamped in Mount the unit in the front panel using the screw tensioners provided and insert the screw tensioners in the OP housing and rotate the threaded spindles backwards against the front panel Threaded spindle Allen key Cale 8 4 3 Replacing the batteries The Lithium batteries are used to back up operating data in the static RAM and to supply the CMOS clock module when the power supply voltage is switched out Procedure 1E To prevent data loss the battery may only be changed with the power supply voltage switched on 1 Remove the battery cover and take the battery out of its holder 2 Remove the battery connector to the cable 3 Insert the new battery in the inverse sequence Battery type 3 V 480 mAh Lithium cell Siemens AG SIMADYN D Caution Please observe the ESD guidelines and the
21. ocess data can be simultaneously displayed upper and lower display line The 24 values are distributed over two panels V1 V12 SHIFT for selection Both panels can be sub divided according to the reference and actual values as required for example 20 actual values can be configured or just 3 The distribution according to reference and actual values is exclusively realized by the SIMADYN D configuring The selected process data values are as default setting always displayed normalized and with dimension information and names If a name hasn t been configured then the designator VALUE xy xy 1 24 is displayed as default If a non configured process data is selected the following display appears No 14 NO MEASURED VALUE INITIALIZED This text is displayed for 3 seconds and then the previous text is re displayed 1 2 2 Behavior at run up After OP 2 has been initialized it automatically goes into the data processing mode The last selected values are re displayed At first run up the first two configured values are displayed normally the V1 and V2 If only one process data has been configured operating message No 14 is displayed in the lower line NO MEASURED VALUE INITIALIZED If no process data have been configured in SIMADYN D OP2 goes into the basic message system processing function If data processing is selected later then operating message No 14 is displayed in the upper line NO MEASURED VALUE
22. on 1 5 The message classes are defined in SIMADYN D when configuring the message systems refer to the communication configuring instructions message class prefix 1 4 2 Operator control overview for message processing The message system processing is selected via the MSG key After selection the LED key is lit If the OP2 has not received any messages then operating message No 16 is displayed NO MESSAGES PRESENT The text is displayed until either a new message is received or another function is selected e g VAL key If the OP 2 received new messages from SIMADYN D since the last message system processing selection then the MSG key LED flashes if the message system processing is not selected If the message system processing is selected for the first time the last selected message is re displayed If the key is repeatedly depressed the latest message is displayed The selected OP2 message system is scrolled through using the raise lower keys The key actuation sequences for all functions in the message processing are subsequently listed OP 2 rejects inadmissible key combinations with the appropriate acknowledgement Siemens AG 465 981 7101 23 Edition 02 96 1 5 SIMADYN D STRUC G User manual 1 Overview 1 4 3 Message display The OP2 displays messages in two different message formats The two message formats are ASCII text messages they consist of Date time message type message text and process data dimensions
23. rization for the USS interface Siemens AG 465 981 7101 23 Edition 02 96 1 11 SIMADYN D STRUC G User manual 1 Overview 1 5 5 Parameterization for the printer m 1 5 6 End of system operation System operation is ended by selecting END and depressing the ENTER key MESSAGE USS INTERFACE lt q PRINTER DISPLAY OPTIONS CURSOR Function selection ew Description If a new bus initialization to SIMADYN D is requested YES must be specified otherwise NO Display INIT REQUEST CURSOR ENTER en Transfer Ea Le Function selection 1 12 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview 1 5 7 Parameterization display options a 1 5 8 Self test The user can test all OP 2 partial components using the self test The self test can only be selected from the system mode Starting the self test The system mode is selected by pressing the SYSTEM key longer than 3 seconds The start of the self test is initiated by simultaneously depressing the following keys The particular function is selected with the cursor keys and confirmed with ENTER The fo DISPLAY TEST Various test patterns are displayed Display errors faults can be visually checked The test is ended with ENTER USS INTERFACE TEST Cyclic data are sent simultaneously received and checked via the USS bus During the test the following message is d
24. safety related information for Lithium batteries in the preamble to Section 4 of the Equipment Manual 465 981 7101 23 Edition 02 96 1 21 STRUC G User manual 1 Overview 4 4 Connecting element Printer SIMADYN D control DR210 211 N DR230 231 N USS master USS bus OP2 Lower side of the unit V 24 TTY RS485 SS1 IF1 SS2A IF2A SS2B IF2B Te ets Je eke eL Terminal block voltage power supply Unused V 24 TTY Ground connection 4 5 Power supply The 4 pole terminal block is used to connect up the power supply voltage and the authorization input The authorization input is not used Connecting up individual cables Terminal block connections 1 4 ms ee e Se A Unused i lt H mm OV 24 V DC power supply voltage AN Cable cross section which can be used 0 5 2 5mm 4 6 Baud rates OP 2 can be operated on the USS bus with the following baud rates 9 6 19 2 93 75 187 5 Kbaud 4 7 Cable and connectors 4 7 1 Connector assignment OP2 is always connected at the SS 2B interface RS485 USS bus 1 22 Edition 02 96 Siemens AG 465 981 7101 23 SIMADYN D STRUC G User manual 1 Overview Assignment SS 2B 5 1 Pin RS 485 eo 1 Ke e o o o 3 2 J 3 DataB 4 9 6 5 GND 6 5V 7 8 DataA 9 4 7 2 Bus configuration
25. t characters tt mm jj hh mm ss 222 T MAX 28 CHARACTERS 999 12345 678 E 99 DI MENSI O 2 P32 message without process data maximum 56 message text characters tt mm jj hh mm ss 222 T MAX 5 6 CHARACTERS RECEIVED FROM SI MADYN D 3 P16 message with process data and dimension maximum 28 message text characters tt mm jj hh mm ss zz MAX 2 8 CHARACTERS 999 12345678901 23 DI MENSIO 4 P16 message without process data maximum 56 message text characters tt mm jj hh mm ss zz MAX 56 CHARACTERS RECEIVED FROM SI MADYN D Example of a P32 message in the ASCII 2 text format with measured value without dimension 01 10 94 00 00 05 1167 W MOTOR OPERATES WITH UE CURR 99999 1234567 E 99 W stands for the alarm message type is configured in SIMADYN D 1 4 5 Prefix suffix message F or prefix suffix format the following message formats can be displayed at the OP 2 d day m month or minute y year h hour z millisecond t message type alarm fault etc 1 P32 message with process data and dimensions tt mm jj hh mm ss 222 T P 54321 GG by Abc eal 999 12345678 E 99 DI MENSI O Siemens AG 465 981 7101 23 Edition 02 96 1 7 SIMADYN D STRUC G User manual 1 Overview 2 P32 message without process data tt mm jj hh mm ss 222 T ye tho A al S52 6g 2 il 3 P16 message with process data and dimensions tt mm jj hh mm ss zz Pe BoA ul Ob 8 Ge 7G 999 1234567890123
26. y Check the bus configuration and software 26 INIT ERROR NO BINARY VALUE INIT Process data initialization incomplete OP 2 expects additional binary value DATA initialization data OP 2 is not ready Check the bus configuration and software 27 INIT ERROR MEASURED VALUE INIT Erroneous initialization data for process data OP2 is not ready Check the bus DATA configuration and software 2 NIT ERROR BINARY VALUE INIT DATA Erroneous initialization data for binary values OP2 is not ready Check the bus configuration and software 29 MEASURED VALUE CHANGE ERROR Process data change error Unsuccessful process data change in the VAL CHANGE mode Repeat the function and if required check the software 30 INITIALIZATION ERROR DELAY Time monitoring exceeded during initialization OP 2 not ready Check the bus configuration and software 31 INTERRUPTION TO THE HOST No USS telegrams received CONNECTION Check the bus connection cable 32 NO BUS CONNECTION INCORRECT No telegrams are received with their own station address Configuring erroror 2 2 1 5 4 STATION ADDRESS incorrectly set bus address 33 PRINTER NOT READY OR NOT OP2 cannot print The printer does not respond Check the printer and printer CONNECTED connecting cable EPROM SAVE UNSUCCESSFUL Unsuccessful data save in the EPROM VAL CHG mode Check the software 1 2 3 36 TELEGRAM ERROR NO BUS Check the bus configuration check the configuring master