1. 10 seconds self recording alarm voice will be sent out when alarming support monitor and intercom function 6 Arm disarm partial arm partial disarm by keyboard remote controller SMS or remote telephone mobile phone disarm by keyboard need password 7 Timing control arm partial arm disarm 8 Program the alarm host by keyboard or SMS 9 Modify the name of 26 wireless guarding zones and inquire the status of alarm host by SMS demand 10 Define the 26 wireless guarding zones as arm partial arm by keyboard on the alarm host 11 With standby rechargeable battery 12 The alarm host automatically stores system status while its power is off 13 Connect with the alarm center through GSM network Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworld com 4 13 Home Alarm System HA G50B User Manual Specification a GSM GSM frequency 900 1800MHz or 850 1900MHz b Alarm method adopts SMS data transmission and voice platform c Stand by power consumption lt 0 6W b External power failure alarm e Alarm response time Less than 8s GSM in normality f The volume of siren More than 110db g Power Standby battery DC GAN lithium battery Standby battery working hours more than 15 Hours h Working conditions Operating temperature 10 55 Humidity lt 95 no condensation i Dimension of alarm host Dimension 170mm Long 118mm Wide 40mm High Installation 2 1 Main
2. and begin 10 second record When finish the record release the button and then the indicator turn off and quit the recording state Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworld com 9 13 Home Alarm System HA G50B User Manual SMS control command 4 1 Set three mobile phone numbers for SMS alarm Input SMS 4 numbers for password DD serial number mobile phone number Example Set 1388888888 as the first mobile phone number for SMS alarm The host s password is 1234 Send SMS 1234DD11388888888 Note The serial number shows alarm sequence must be 1 2 and 3 4 2 Set three phone numbers for auto dialing alarm Input SMS 4 numbers for password DD serial number phone number Example Set 01088888888 as the first phone number for auto dialing alarm The host s password is 1234 Send SMS 1234DD401088888888 Note The serial number shows alarm sequence must be 4 5 and 6 4 3 Delete alarm phone numbers Input SMS 4 numbers for password DD serial number Example The host s password is 1234 If you want to delete the first alarm phone number Send SMS 1234DD1 Note The serial number shows alarm sequence must be 1 2 3 4 5 and 6 4 4 Change password of alarm host Input SMS 4 numbers for password DD 7 4 new numbers for password Example The initial password is 1234 if you want to set 5678 as the new password Send SMS 1234DD75678 4 5 Arm disarm
3. unit layout Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworld com 5 13 Home Alarm System HA G50B User Manual GSM Antenna CAD 1000 DN Speaker Keypad Disarm Cover at e e S d n bk n See we m SS a ne A ap e w a H A D k ki ers J Ti TON d Da dee CH Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworld com 6 13 Home Alarm System HA G50B User Manual 2 21 Insert a valid SIM into the alarm host GSM wireless alarm system adopts SMS and voice data transmission platform of GSM network to send control command and receive alarm remotely Before installation make sure the SIM card is valid and turn off the power eject the SIM card holder and finish the installation after inserting the holder back with SIM card 2 22 Wired alarm zones Alarm host has two wired alarm zones which display 25 26 on screen about connection please check main unit layout IN1 IN2 Inserted the 4P cable which in standard package to the wired alarm connector the neighbor two lines can forms a wired zones The input alarm signal of the wired zone require contact close detector alarm output signal should be change from open state alarm to closed state alarm 2 23 Main host with tamper alarm Hold down the button of tamper switch when you want to put the host on the desks or walls It will alarm when host is moved Display 55 alarm ringing and i
4. will hear di di sound for confirmation To cancel it press 9999 OK in arm mode b Timing partial arm In partial arm status press SET when SET appears on the LCD display then input time hour minute OK Example Set 16 25 as the partial arm time input 1625 OK then you will hear di di sound for confirmation To cancel it press 9999 OK in partial arm mode c Timing disarm In disarming status press SET when SET appears on the LCD display then input time hour minute OK Example Set 16 35 as the disarm time input 1635 OK then you will hear di di sound for conformation To cancel it press 9999 OK in disarm mode 3 1 9 Prohibit allow sending SMS when arm disarm the system by controller or keyboard After passing the verification of password press SET when SET appears on LCD display input 9 OK then you will hear di di sound for confirmation 3 20 Alarm When alarming the screen DEE SMS TEL and alarm zone number OP means power failure OE means emergency call OF means fire 01 26 are wireless alarm zones 55 for the tamper alarm warning for 90 seconds 3 2 1 Exit setting status In the setting status the host will exit automatically if there is no response within 15 seconds After setting successfully press ESC to exit 3 3 Recording Holding down REC then the recording indicator Z2 will on
5. 30 seconas later the host enters into partial arm mode and L is on Press the Jn the host will enter into partial arm mode immediately c Disarm Press mi to close the system the host enters into disarm status after the host makes di di sound and bere is on Di 1 IS 5 11 Disarm by keyboard on the host In arming status press Disarm button when SET appears on the LCD display then Input password OK will disarm 5 2 Emergency alarm When an emergency alarm occurs press and the host will enter into emergency alarm status immediately and the siren will alarm for 90 seconds to inform the neighbors At the same time it will automatically dial the preset alarm phone numbers cycled for three times and send SMS of Emergency alarm 5 3 External power failure alarm When the system checks out that there is something wrong with the external power or the external power is off for more than 2 seconds it will enter into alarm status immediately At the same time the system will automatically dial the preset phone numbers cycled for three times and send the SMS of External power failed When the power supply is on the system will stop alarming immediately and send the SMS of External power is OK 5 4 Alarm and Handle The siren sounds loudly for 90 seconds to inform the neighbors At the same time the Winwill World Co Ltd Website www winwillworld com Inquire now sales winwil
6. Home Alarm System HA G50B User Manual HA G50B GSM alarm User Manual Ver 1210 100706 Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworld com 1 13 Home Alarm System HA G50B User Manual Dear users Thank you for purchasing our products Please read through this manual before using this product so as to operate the product properly The GSM alarm system adopts the newest GSM network and Digital Signal Processing technology and is widely used in security field With SMS data transmission and voice platform of GSM network it really realizes wireless alarm control and remote managements and solves the limitation of wired data transmission in telephone and wired network Perfect structure convenient installation easy operation with wireless control keyboard are designed for the idea of people oriented which will make you feel easy and comfortable while use this system People is center technology is first is our company s action rule Customer Satisfaction is our consistent pursuit Perfect system excellent services sincere attitudes will bring you a new enjoyment Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworld com 2 13 Home Alarm System HA G50B User Manual Contents Bes WES CPC NO ME 4 0 ENS tal 2 1 Alarm Host s section Toure 5 22 ANWO AM AA MI OND au shear ie E teka tt ete n e ip n e ae E A tt tt E pk e a a a eee 2 21 Insert a valid SIM int
7. SMS for remote arm 4 numbers for password A1 SMS for remote disarm 4 numbers for password A2 Example The host s password is 1234 If you want to set the host in arm mode Send SMS 1234A1 4 6 Change zone s name Input SMS 4 numbers for password DM zone s code 2 numbers changed name Reply SMS Changed zone s name Note The zone name zone is 1 6 characters Zone number is two figures form 01 to 26 Example The password is 1234 If you want to change zone O6 s name to be PIR alarm for bedroom Send SMS 1234DMO06 PIR alarm for bedroom Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworld com 10 13 Home Alarm System HA G50B User Manual Note Changed name should be less than 24 characters Zone s code 01 to 08 each code with two numbers 4 7 Inquire host s arm disarm status Input SMS 4 numbers for password W1 Reply SMS The host s arm disarm status 4 8 Inquire host s external power status Input SMS 4 numbers for password W2 Reply SMS The host s external power status TT Usage 5 1 Arm disarm by remote controller a Arm Press Mai on remote controller the host will make di sound the LCD display is on Bi is twinkling 30 seconds later the host enters into arm mode and the Bik is on If you want to arm the system quickly please press CA b Partial arm press s t the host will make di sound the LCD display is on twinkling
8. com 3 13 Home Alarm System HA G50B User Manual 5 11 Disarm by keyboard on the boset el ll tele etat etat a arete aereaosteseeseseeesonos 11 5 2 Emergency aarm TI 5 3 External power failure alamm ll 54 Alarm and NAN AN ENN Operation GAU MON EN 12 Encode the wireless detectors and remote controller cessseeseeees 12 Appendix Operation guidelme lili ate a tt tett anana aaa ar tsasasttanasannnanasananasasannnnaannnn DO 1 Instruction 1 Instruction The alarm system adopts SMS data transmission and voice platform of GSM network to send control command and receive alarm remotely The system can be set delayed arm When a signal is detected by detectors the detectors will send alarm signal to host immediately then the host sends alarm SMS to its preset mobile phone numbers and meanwhile dials its preset telephone mobile phone numbers automatically and drive wiretap In addition the color LCD can show the time date and the status of arm disarm GSM signal power alarm etc With the LCD it is very easy for you to operate Following are the specific functions 1 Built in SIMCOM double frequency GSM module SIM300 or SIM340 2 With color LCD show screen and keyboard on the host 3 1 wireless SOS zone 1 fire alarm zone 24 wireless guarding zones 1 external power failure alarm zone 2 wired alarm zone 4 Send SMS to 3 group mobile numbers and call to 3 preset telephone numbers by turns while alarming 5
9. d com 7 13 Home Alarm System HA G50B User Manual Note Serial number can only be 1 2 3 and the number 1 is the first mobile phone number For SMS alarm The phone No must be less than in 20 numbers b Delete the mobile phone number Input serial number OK then you can cancel the mobile phone numbers 3 1 3 Set delete three phone numbers for auto dialing alarm a After passing the verification of password press SET button when SET TEL appears on the LCD display Input serial number phone number OK Example Set 1368888888 as the first phone number for auto dialing alarm Input 4 1368888888 OK then you will hear di di sound for confirmation Note Serial number can only be 4 5 6 and the number 4 is the first phone number for auto dialing alarm The phone number can be mobile phone or telephone but mustn t be more than 20 numbers b Delete the phone number Input serial number Ok then you can cancel it 3 1 4 Change password of the alarm host After passing the verification of password press SET when SET PAS appears on the LCD display Input 7 new password OK Example Set 4321 as the new password Input 7 4321 OK then you will hear di di sound for confirmation Note The initial password is 1234 must be four numbers 3 1 5 Set new ID of the alarm host After passing the verification of password press SET when SET ID appea
10. d com 13 13
11. lworld com 11 13 Home Alarm System HA G50B User Manual system automatically sends SMS alert and auto dial the preset phone numbers by turn The user can listen to the pre recording warming voice and enter monitoring status which supports intercom function The system will auto dial the next phone number if the phone line is busy or can t put through It will stop to call the next one when somebody answers the phone If nobody answers the phone the system will stop dialing after auto dialing circularly for three times VI Operation Cautions Make sure the equipments have no water Install the system in a hidden place Turn off the power supply before insert take out the SIM card Connect the power supply firmiy and provide good heat dissipation Don t install the system close to the objects which generate strong interference such as TV set and computer 6 Check all the detectors and their battery in time and change them when voltage is low 7 Inspect the GSM alarm system termly 8 This product is designed for the indoor use rather than outdoor use aoe YS Encode the wireless detectors and Remote controller Name el e 2288 A7 8 DQ 130 D0 120 DA 119 D30 100 of product AO to A7 a pe xe me ne ne Main unit A0 A6 PIR wireless address code of sensor the alarm host Magneti c contact detector Zone 16 oe el e Winwill World Co Ltd Website www winwillworld com Inquire now sale
12. nform master by SMS and remainder 2 3 Run The host will search GSM signal and the signal indicator flash in every 3 second regularly after start up After setting the time the screen will show the time the strength of the GSM signal arm or disarm status and com blinking When the host s external power supply is normal LCD backlight is on When the host detects there is no external power supply LCD backlight will be turn off automatically but for alarm partial alarm delay alarm and keyboard settings LCD backlight will keeps on 3 Operation steps 3 1 keyboard setting Note When setting by the keyboard every time you press the button you will hear di sound for confirmation Please press it again if there s no voice Press CLS button before inputting OK to cancel the input numbers If the LCD display shows FAIL check and reset it 3 1 2 Set delete three mobile phone numbers for SMS alarm a Set the mobile phone number After passing the verification of password press SET button when SET SMS appears on the LCD display input serial number mobile phone number OK Example Set 1368888888 as the first mobile phone number for SMS alarm Input 1 1368888888 OK then you will hear di di sound for confirmation According to the method you can finish the setting of the other two mobile phone numbers Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworl
13. o the alarm host 2 22 Wired zooms 2 23 Main host with tamper alarm 2 3 Run Operation SCS EG Oe Sel DV keyboard EE 7 3 1 1Password VETIFICATION e 3 1 2 Set delete three mobile phone numbers for SMS aam 7 3 1 3 Set delete three phone numbers for auto dialing aam 8 3 1 4 Change password of the alarm bhoset 0 ccceeccceeceseeeeeseeeeeeeeseeeaeeeeeaaes 3 1 5 Set new ID of the alarm host 0 cece cece ee ceeeeeeeseeeeeseeeeeseeeeseeeeaeeeeaee ees 3 1 6 Set type of 8 wireless guarding zone CE oO 3 1 7 Set time of the alarm boer 3 1 8 Set cancel the time of arm disarm partial am 9 3 1 9 Prohibit allow sending SMS while arm disarm the system by controller or keyboard 9 22 Q EXIT SOURI OS A US ei onn ankre er cs anl ke a kn pov en a e kep so e e et e a ko e n 2 3 3 Ke del ue BE 9 SMS control commande tee a aaa nana a aa aaa aaa aa asa a asa assassssessssesossosssaossaasosnonnonn 9 4 1 Set three mobile phone numbers for SMS aam 9 4 2 Set three phone numbers for auto dialing aam 10 4 3 Delete alarm phone numbers 10 4 4 Change password of the alarm boer 10 ED PUTA US UU EE 4 6 Change guard zoneename eee eee tt eetteeotoseooooeoooseooeooeoeoeeooooon 10 4 7 Inquire host s arm diSarm status IO 4 8 Inquire host s external power status 11 5 1 Arm partial arm disarm by remote controller 11 Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworld
14. rs on the LCD display Input O six new ID numbers OK Note the initial ID is 000000 Example Set 123456 as the new ID Input 0 123456 OK then you will hear di di sound for confirmation 3 1 6 Set type of 8 wireless guarding zones After passing the verification of password press SET when SET TYPE appears on the LCD display Input zone numbers When there is illegal intrusion the zones will alarm in partial arm mode OK Example Set zone 4 6 8 as alarm zones in partial arm mode input 468 OK then you will hear di di sound for confirmation When alarming zone 4 6 8 will alarm but other five zones will not alarm in partial arm mode 3 1 7 Set time of the alarm host After passing the verification of password press SET when SET appears on the LCD display Input 8 year month day hour minute second each with two numbers OK then you will hear di di sound for confirmation Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworld com 8 13 Home Alarm System HA G50B User Manual Example Suppose the present time is 12 13 05 and the date is 08 01 2007 input 8 070108121305 OK 3 1 8 Set cancel the time of arm disarm partial arm a Timing arm In arming status press SET when SET appears on the LCD display then Input time hour minute OK Example Set 16 08 as the arm time input 1608 OK then you
15. s winwillworld com 12 13 Home Alarm System HA G50B User Manual pe BS E Zone 19 Request High level N connect with H Request Low level N connect with L No connect NC No request Appendix Operation Guideline By following steps you can operate it easily though it is the first time to use this product 1 Remove the SIM slot cover with screwdriver and insert a valid SIM card into the alarm host Please see 2 2 2 Make sure the power supply is connected turn on the host power switch Please see 2 3 3 Set the mobile phone telephone numbers for SMS alarm and auto dialing alarm For details please see 3 1 2 3 1 3 4 1 and 4 2 4 Set time of the alarm host for details please see 3 1 7 5 As per the operation instruction of page 13 encode the wireless detectors and remote controller to match with the alarm host and allocate the detectors to wireless zones separately Please make sure to record the corresponding zone number of each detector 6 Set zone type please see 3 1 6 for details 8 Change zone s name according to your needing Please see 4 6 for more details 9 Change password of the alarm host Please see 3 1 4 and 4 4 for more details 10 Set time of arm disarm according to your needing Please see 3 1 8 for more details For specific operation please read this manual carefully Winwill World Co Ltd Website www winwillworld com Inquire now sales winwillworl

Download Pdf Manuals

image

Related Search

Related Contents

Cisco Systems CALLMANAGER OL-1531-01 User's Manual  Zenith P42W46X 42 in. Plasma EDTV  GQ GMC-300E Plus Geiger Counter User Guide  October/December 2012  Philips monitor accessory SB7S19S  Mode d`Emploi Vintage MP  TUBELED CONTROLLER user manual - COMPLETE  Mode d`emploi  MAN-YCO02IS-0CE-d  LG WT1201CV Specification Sheet  