Home
Table of contents
Contents
1. Example for Ericsson A1018s press keys then Yes to unlock the keypad if there is the case press key successively for 2 times Mail menu will show up press key Yes Read messages menu will show up Press key Yes press key or gt until the message to be erased was found press key Yes Enter the message reading mode If the current message is not the one to be erased press key NO and restart looking it up If the current message is the one to be erased press key CLR Press key YES to answer Erase question In case Store question shows up answer No press NO to exit the submenu 7 Exit the mobile phone programming menu 13 Example for Ericsson A1018s Press key NO for several times until the general message is displayed indicating the used GSM network and the current time and date eventually 8 connect the phone to the GSM module 9 Power up the GSM module In case of modifications modify the configuration SMS save it and erase the old one Do all these when the GSM module is not connected TECHNICAL CHARACTERISTICS supply voltage 11 13 8Vde maximum taken current including GSM phone loading 500mA average taken current loaded GSM phone 40mA Components GSM 11T module 1 pcs cable for mobile phone interconnection 1 pcs 6 wire cable 1 pcs 3 wire cable 1
2. lt esmeart GSM communicator Hook up Installation and Programming Manual Doc 10112 version 2 0 Table of contents GENERAL FEATURES eterin t En AAA EEEE EEEE a EER 3 Applications of the GSM 11T communicatot 0 cece eeeeeeeeees 3 Functions of GSM 11T communicator sA Functioning modes of the GSM 11T communicator cece 4 TECHNICAL FEATURES scssccrscncsnseinnescgeinsneimensga veabuieneenesseneess 5 DTMF communication formats of the alarm control panel 0 5 Available inputs and output 00 cece ceceeeseeseeseeeeeeeeeeeeeeseeeeaeeeeenateaee 5 Functioning indicators ra Consumption eee wD GSM network specifications 0 eceeceeceeseeeeeeeeeceseeeeeeeeeseseeeeaeeeeeneeeaes 6 INSTALLATION vissiiviss scaneawcs napailven dunce cuaneiniae NAINE 6 GSM module installation cc cgecescssysssescnsesesresvcsesterecstosvystonssevsevsncneeeset 6 GSM module programming cece eccece eee cseeeeeeceeeseeseeeesesseseeeeeeetaees 8 GENERAL FEATURES GSM 11T communicator can be used as an accessory for a burglary control panel with digital communicator or as a stand alone alarm unit It is made up of one GSM module and a GSM phone from Ericsson family see Usable GSM phones GSM 11T communicator can be connected to a burglary control panel as backup for the telephone line in case it is faulted or directly in case of missing telephone line Thus the communicator pr
3. ble only for Ademco Express 4x2 format 3 The meaning of sent codes associated to the events occurred was implemented in this software version of the GSM communicator according to the table below F9 Trouble Siren loss E9 Restoring Siren restoring FB Trouble Phone line loss EB Restoring Phone line restoring 1x Fire Fire alarm 2x Panic Panic 3x Burglary Alarm on zone x 4x Medical emergency Medical emergency 5x Tamper Ambush 6x Bypassed zone Bypass zone x 9x Periodical Test Periodical Test Bx Disarming Disarm by code x Cx Arming Arm with code x Ex Restoring Zone x restoring Fx Trouble Trouble on zone x Others Unknown code X zone or user number Event and zone user code Event denomination SMS message 00 communicator input 1 activation TRIG1 ON 01 communicator input 1 deactivation TRIG1 OFF 02 communicator input 2 activation TRIG2 ON 03 communicator input 2 deactivation TRIG2 OFF 04 communicator input 3 activation TRIG3 ON 05 communicator input 3 deactivation TRIG3 OFF 06 communicator input 4 activation TRIG4 ON 07 communicator input 4 deactivation TRIG4 OFF 08 communicator input 5 activation TRIG5 ON 09 communicator input 5 deactivation TRIG5 OFF 0B communicator input 6 activation TRIG6 ON 0c communicator input 6 deactivation TRIG6 OFF oD GSM signal weakening trouble with the GSM netw
4. comma code generated by activation ground connecting of the fifth communicator input 2 HEX digits comma code generated by deactivation of the fifth communicator input 2 HEX digits comma 11 code generated by activation ground connecting of the sixth communicator input 2 HEX digits comma code generated by deactivation of the sixth communicator input 2 HEX digits comma code generated by GSM signal weakening 2 HEX digits comma code generated by the periodical test 2 HEX digits comma duration in hours the periodical test is performed at 2 decimal digits period Note All fields previously defined will be filled in but the phone numbers eventually If the first phone number of the GSM monitoring station is present in the configuration SMS the communicator will transmit certain events to the monitoring station If the second phone number is programmed the communicator will transmit SMS messages to this second phone number A typical example of a configuration SMS message 0744111111 0744212223 123A FB EB 00 01 02 03 04 05 06 07 08 09 0B 0C 0D 90 10 By this SMS the GSM communicator is programmed to transmit its own and the burglary control panel generated event codes to the monitoring station with the phone number 0744111111 SMS messages associated to events will be transmitted onto the mobile phone number 0744212223 Codes generated by the burgla
5. er For format Ademco PID the interface will not generate clear SMS messages Notes In the edit mode digits can be obtained directly by pressing the corresponding keys longer The comma and period can be obtained by successively pressing key 1 Upon editing each key is used for several symbols i e letter C is obtained by successively pressing key 2 for 3 times Press shortly key in order to switch from capital to small letters or vice versa modifies the last edited character from capital to small letter or vice versa Keys gt and are used to move the slide to the right and left within the edited message By long pressing these keys the slide is directly moved to the beginning or end of the edited message Key CLR Clear is used to delete the character on the right or left of the slide conn also 6 Save this SMS with no destination phone number in the phone memory not the card s Example for Ericsson A1018s In the edit mode after the configuration message was edited press key Yes The destination phone number will be answered to with NO If there is the case to modify an existent message answer with key NO to the Store and Erase questions Note There must be only one message stored in the mobile phone that is the configuration SMS message Older messages must be erased The number of SMS messages in the card s memory is not restricted
6. ming SMS in the GSM phone press key gt once or several times until the configuration SMS appears on the display press key Yes 5 in this case a configuration SMS will be created having the next structure the phone number of the monitoring station it can miss in case events are not to be transmitted to the monitoring station comma the phone number for SMS messages it can miss in case SMS messages are not to be transmitted comma client s account 4 HEX digits comma code generated by phone line loss 2 HEX digits comma code generated by phone line restoring 2 HEX digits comma code generated by activation ground connecting of the first communicator input 2 HEX digits comma code generated by deactivation of the first communicator input 2 HEX digits comma code generated by activation ground connecting of the second communicator input 2 HEX digits comma code generated by deactivation of the second communicator input 2 HEX digits comma code generated by activation ground connecting of the third communicator input 2 HEX digits comma code generated by deactivation of the third communicator input 2 HEX digits comma code generated by activation ground connecting of the fourth communicator input 2 HEX digits comma code generated by deactivation of the fourth communicator input 2 HEX digits
7. nel and retransmitting them through the GSM network in digital format to a GSM interface monitoring station optionally clearly as SMS messages onto a different mobile phone i e on the mobile phone of the burglary control panel protected objective s owner provides 6 individual inputs to which sensors can be connected burglary fire etc allowing the independent usage of the GSM communicator when the burglary control panel is missing transmits a periodical test with a programmable period transmits a code in case of weak GSM signal detects mobile phone shutting down and commands its turning on Functioning modes of the GSM 11T communicator GSM 11T communicator can function in 3 ways it transmits events occurred at the objective protected by the burglary control panel only to a GSM monitoring station Xwatch DPC 08 it transmits events occurred at the objective protected by the burglary control panel only as SMS messages to the mobile phone of the objective s owner 4 it transmits events occurred at the objective protected by the burglary control panel both to a monitoring station and as SMS messages as well to the mobile phone of the objective s owner Define the phone number of the monitoring station and or of the mobile phone of the alarm system s owner within the configuration SMS in order to select the functioning mode Events generated by the burglary control panel are taken and for
8. of the burglary control panel protected objective s owner GSM phones with versions older than 1999 must not be used The software version of the mobile phone can be read if successively pressing the next keys gt ge cK INSTALLATION The GSM module will be connected between the burglary control panel and the GSM phone GSM module installation The connectors order from left to right is the next 6 pin connector the cable is connected to the GSM phone 6 pin detachable connector yellow wires will be connected to the phone line connectors of the burglary control anel 7 Ms red wire will be connected to the 12V power supply i e Ux 11V 14V the black wire must be connected to ground blue wires must be connected to the phone dose 6 8 pin detachable connector for automation outputs upon construction input detachable connector in 2 variants 3 pins ground and 2 inputs black white white optional 7 pins ground and 6 inputs for input extension Note If the green LED does not turn on or the GSM communicator is supposed not to function do the next 1 disconnect the GSM module and the GSM phone connectors JP1 and JR1 shut the GSM phone down wait for at least 10 seconds restart the GSM phone check if the local SMS message in the GSM phone can be read In case a Please wait or similar type message does not show
9. ol panel if the latter can supply 500mA or from a different power supply i e SC 3 GSM network specifications can be used in any GSM authorized network Usable GSM phones Ericsson A1018s Other technical features average duration of GSM communication 8s active inputs by GND maximum current at open collector outputs 500mA WARNING For this present version the software in the GSM communicator does not allow using the GSM phone connected to the GSM module in function for vocal phone communications Hence if this GSM phone is used simultaneously for conversations the proper functioning of the GSM communicator is no longer assured The mobile phone of the communicator is recommended to be used for this application exclusively Its client number must not be disclosed as someone could call it However if the phone must be used for an emergency the phone should be programmed as the client number is not displayed on the called phone display The GSM hardware was designed to allow more developed versions of the software free of charge upgrades in the future These versions will allow implementations of automation commands on the present hardware 6 outputs at the most and remote process supervision 6 inputs at the most The present software version of the GSM communicator allow its usage together with Xwatch DPC 08 monitoring station produced by Romano Electro and SMS message transmission on the mobile phone
10. ork FO Trouble AUX loss E0 Restoring AUX restoring F7 Trouble 220V loss E7 Restoring 220V restoring F8 Trouble Discharged battery E8 Restoring Loaded battery Programming mode 1 Disconnect the GSM module from the power supply if it was previously loaded 2 Disconnect the GSM phone from the GSM module connector 3 Deactivate the PIN code according to the phone user manual 4 Enter the programming mode of the GSM phone in menu Mail then Send Message Example for Ericsson A1018s Buttons and gt are for scrolling command menus and sub menus on the same level Button Yes is used for entering the submenus of the current command menu Button No is used to exit the current menu and return to the main menu Keys Yes and No are for positive or negative answers to current questions that the GSM phone user is asked press keys then Yes in order to unlock the keypad if the case press key twice Menu Mail appears press key Yes Menu Read messages appears press key gt Menu Send message appears press key Yes Sub menu New appears if the GSM phone has not been used to program the GSM module before or if the GSM phone does not contain any SMS for GSM communicator setting programming press key Yes 10 if the GSM communicator is reprogrammed or if there is a GSM module program
11. otices if the phone line is missing by accident or intentionally from the alarm system takes the control panel s events and drives them to a GSM monitoring station phone line back up Thus the alarm system is never vulnerable and will transmit any event to the monitoring station in real time an objective protected by an alarm system with digital communicator for which a phone line is not available remote villas depots can report system events to a monitoring and intervention for a lower cost compared to the radio monitoring an application for event transmission regarding some inputs status when no alarm system is needed panic buttons etc an application for input remote control using the own mobile phone turning on central heating light etc under construction Note for the first 3 cases appropriate events can be transmitted not only to a monitoring station but also onto the own mobile phone through clear messages in SMS format example for the objective with code 0261 an alarm was detected on zone 2 disarm by code 1 The next image describes functions of this communicator The digital GSM communicator performs several functions detects loss and restoring of the phone line which the burglary control panel is connected to and forwards these events supervises the phone line in case that one gets faulted the communicator will generate the line tone taking the events occurred at the control pa
12. ovides a higher security level for objectives protected by burglary alarm systems In case the control panel transmits events in DTMF formats the GSM module receives and codifies them while the GSM phone transmits them to the GSM monitoring station which must have a GSM interface This GSM interface decodes the signal transmitted by the communicator GSM phone The GSM interface is produced by Romano Electro Company as an accessory for the Xwatch DPC 08 monitoring station The owner of the burglary alarm system can optionally get SMS formatted event description on his her own GSM phone GSM 11T communicator can be used in all GSM telephone networks selected through the acquired SIM card GSM 11T communicator is totally compatible with the burglary control panels in Cerber XL Paradox families etc Parameter programming is performed by means of the GSM phone Applications of the GSM 11T communicator Connection of GSM 11T communicator in the alarm system Programmable outputs a a a The phone of the alarm system s owner alarm GSM control panel communicator Inputs with programmable codes Phone line from Rom Telecom control panel GSM monitoring station Functions of GSM 11T communicator GSM 11T communicator was designed to be used in one or several situations below an alarm system with a digital communicator can function more securely if an GSM 11T module is added This module n
13. pcs GSM phone from Ericsson family in accordance to the technical specifications is not for delivery purposes It can be acquired from the GSM network distributors agreed by the beneficiary Each user can choose the favorite type of subscription and GSM network Romano Electro Int sa n A innovating for safer life 27 29 Calimachi St 72266 Bucharest 1 Tel 021 204 47 00 Fax 021 242 20 30 E mail sales roel ro WwWW roel ro ZZ 14
14. ry control panel will keep the client s account number settled in the control panel Events generated by the communicator will have the account number 123A Upon phone line loss and phone line restoring respectively the communicator will generate codes FB and EB having the account number 123A Upon activation deactivation of the 6 inputs of the communicator codes 00 02 04 06 08 OB and 01 03 05 07 09 and 0C with account number 123A will be generated Upon GSM signal weakening the interface will transmit code OD settled in the configuration SMS to the monitoring station The interface transmits code 90 for the periodical test The duration for the periodical test performing is 10 hours Note Changing codes associated to events in the configuration SMS will trigger the appropriate interpretation of events associated to these codes For example if the 6th parameter is programmed 38 instead of 00 then upon activation of the first communicator input an Alarm on zone 8 SMS type will be transmitted instead of TRIG1 ON while the monitoring station will consider the event of the same type Any change of the configuration SMS is accompanied by a restart of the GSM module 12 Note Format DTMF 4x2 describes events in such a manner that necessary information is presented by means of 6 HEX digits AAAAEZ where AAAA is the client s account number E is the event code Z is the zone user numb
15. up wait for 5 seconds and try to read the SMS message again This sequence will be repeated until the SMS can be read 6 connect the phone to the GSM module connector JR1 and the GSM module connector JP1 The green LED should turn on after 2 8s ak OP D StatusLED for GSM phone White Inputs GND 412 Outputs Telephone dose GND 12V Phone line connectors in the burglary control panel Yellow GSM 11T GSM module programming Note Before programming the GSM module program the burglary control panel to phone line transmit events in DTMF formats Ademco Express or Ademco PID to the monitoring station All parameters of the GSM module will be programmed from the GSM phone keypad optionally the phone number of the monitoring station in case events are to be transmitted to the monitoring station optionally the phone number of a different mobile phone i e of the protected objective s owner for SMS messages associated to events client s account for events generated by the GSM communicator codes generated for phone line loss and restoring codes generated in order to activate deactivate the communicator s inputs code generated to make the GSM signal weaker code generated for the periodical test Notes 1 SMS messages are implicit and automatically generated Message issuing is not allowed in this software version 2 SMS messages are availa
16. warded to the monitoring station and or the mobile phone of the client The message containing these events also contains the control panel s account number If the regular phone line is present the events are directly sent on the phone line being ignored by the communicator If the regular phone line is not present the events are taken by the communicator and redirected through GSM The events generated by the communicator are phone line loss restoring communicator s local inputs activation deactivation weak GSM signal and periodical test A 4 HEX digit account number should be defined for these events These events generated by the GSM communicator are transmitted through GSM irrespective of the phone line status TECHNICAL FEATURES DTMF communication formats of the alarm control panel ADEMCO Express 4x2 Contact ID PID Available inputs and outputs 6 inputs with programmable codes for activation and deactivation 6 open collector outputs used for automations upon construction Functioning indicators The module has got a green signaling LED indicating GSM phone presence and proper functioning Consumption supply voltage 11 13 8Vde maximum taken current including GSM phone loading 500mA average taken current loaded GSM phone 40mA Notes 1 The GSM phone connected to the GSM module is loaded from the module 2 The GSM module will be loaded from the burglary contr
Download Pdf Manuals
Related Search
Related Contents
MANUEL UTILISATEUR / USER MANUAL - Infosec Volume 3 numéro 2 - ACSM - Association canadienne pour la santé user manual DM 03/08/2015 allegato 1 - Ordine degli Ingegneri della Provincia di 215D CE Parts Manual Rosemount 8732EM Magnetisch-induktives Durchfluss wartung - Husqvarna C-MAG HS 4 digital C-MAG HS 7 digital C Copyright © All rights reserved.