Home
User Manual Legion Meter USB
Contents
1. LeGioN _ _meter Legion Meter USB User Manual Patents Pending PLX Devices Inc 2014 All Rights Reserved Contents 1 Introduction Patents Warnings Key Features Package Contents 2 Overview Intelligent OLED Display 3 Operating Legion Meter Charging Your Device with Legion Meter Toggling Menus About Legion Meter Menus Display Orientation Data Pass Through Switch 4 Product Care and Maintenance Storage Safety Disposal 6 Technical Specifications www plxdevices com ON ON ON ON WO OW W GW N N Introduction Patents PLX Devices Inc currently has patents pending on the charge accelerator hardware firmware and algorithms Warnings Do not use this product and its accessories in any way other than specified by PLX Devices Inc PLX Devices Inc is not liable for accidents or damage caused by misuse of this product Do not tamper disassemble or modify this product This may cause an accident fire electric shock or product malfunction Features 1 Plug and Play Installs in Seconds 2 Integrated High Contrast Organic LED Display 3 Reads USB Voltage Current and Power 4 Resettable Battery Capacity Counter 5 Dynamically Switchable Apple and Android Charge Accelerator 6 Compatible with all USB Ports Package Contents 1 Legion Meter Unit 2 Quickstart Guide www plxdevices com 2 Overview 3 Operating Legion Meter Organic LED Display User Interface Button Charging Your
2. 2 3 x 1 3 cm 0 80Z Voltage Current in out Power mWh Counter PLX Intelligent Battery Monitoring and Metering PLX USB Charge Accelerator 1 Digital Push Button 1 Slide Switch ABS Plastic Power Metering Current Counter Charge Accelerator www plxdevices com TERMS OF USE PLX Devices Inc does not guarantee product functionality with any third party device Implementation and integration of PLX products with any other device s must be done at your own risk LIMITED WARRANTY PLX Devices Inc warrants this product to be free from defects for 1 year from the date of purchase If applicable non serviceable items are excluded from stated warranty Serviceable goods must be determined by PLX Devices to be defective before any warranty or replacement is issued PLX Devices obligation under warranty shall be limited to repairing or replacing under the discretion of PLX Devices any part proven defective This warranty is limited to the repair or replacement of parts in the manufactured good and the necessary labor done to affect its repair or replacement SERVICE UNDER WARRANTY In the unlikely event that your PLX Devices hardware should fail during the warranty period a Return Material Authorization number RMA must be first retrieved from PLX Devices Customer Support Support can be contacted through email rma plxdevices com or by phone 1 408 745 7591 All serviceable goods must be packaged securely with proof of purchase RMA num
3. expose this product to liquid or moisture Liquids can get into and affect the internal components of the product and moisture can lead to corrosion This may result in product malfunction fire and or electric shock Even if Legion Meter appears dry and operating normally after exposure corrosion can still occur and pose a safety hazard Exposure to Heat Do not operate or store this product in or near a heat source or under direct sunlight for extended periods of time Excessive heat can damage the plastic enclosures If your Legion Meter is exposed to liquid or moisture do not attempt to dry your Legion Meter with a heat source such as a microwave oven or hair dryer Disposal For those in the United States please visit the following website for more information on proper electronics dis posal laws and guidelines http www electronicsrecycling org public Be aware that different states might have different laws regarding proper disposal of electronics a L 7 amp www plxdevices com Patents Pending Technical Specifications Voltage Range Current Range Power Range Operating Temperature Connector Type Display Physical Dimensions Weight Meters Intellectual Properties Human Interface Construction Modes Legion Meter 3 0 6 0 Volts 0 3 7 Amps 0 22 2 Watts 0 85 Degrees Celsius 1 USB Male A 1 USB Female A Gold Plated High Contrast OLED 128 x 32 Pixels 2 5 x 0 9 x 0 5 6 3 x
4. Device with Legion Meter 1 Insert the USB Male A end of Legion Meter into any USB power source and make sure the data pass through slide switch is in the A position to enable accelerated charging 2 Press the interface button until the Mode screen is accessed and select your charge accelerator mode NOTE To switch between Apple mode and Android mode press and hold the interface button p a USB Compatible Charge Acceleration Data Pass Through Switch 3 Plug in any USB charging cable to the USB Female A end of Legion Meter Intelligent OLED Displa NOTE Connecting the cable improperly may cause serious damage to the device Any damage caused by S y misuse is not covered by the warranty ps the power in Watts your USB port is currently delivering to your 4 Insert the other end of your cable into the charging port of the device you want to charge evice device 0 r A Shows the current in Amps your USB port is currently delivering to your ca CURRENT OUT APPLE LeGioN MODE meter Shows the voltage of your USB port Resettable milliwatt hours counter used to diagnose battery storage capac ity Toggling Menus Charge accelerator mode allows you to optimize the charge speed of any USB port To toggle through the menus press and release the user interface button located to the right of the OLED display 4 re 7 L 7 A S qa L HR DEVICES INC Y gt DEVICES INC
5. ber with all shipping charges prepaid and shipped to PLX Devices Inc Goods returned under warran ty must be received by PLX Devices Inc within 10 business days after the RMA number has been issued Goods received after this period is subject to fees for the service of repair or replacement All repaired or replaced items shall be warranted for the remainder of the original product warranty RETURNS AND RESTOCKING FEE All returns must be within 30 days of receipt A 15 restocking fee will apply to applicable PLX Devices products returned for refund All returns are to be packed in original condition including packaging documentation manuals and accessories Returns that do not include all the accessories and components may be returned to the customer or charged on a per item basis The customer assumes responsibility for product until receipt at PLX Devices Inc Shipping via an insurable carrier is recommended Any unauthorized shipping charges will be billed to the customer or shipment will be refused DISCLAIMER PLX Devices Inc shall not be liable for direct special incidental or consequential damages resulting from any legal theory including but not limited to lost profits downtime goodwill damage injury to persons or replacement of equipment and property due to improper installation integration and or misuse of any PLX Devices Inc s product s This warranty applies to the original purchaser of product and is non transferable Al
6. l implied warranties shall be limited in duration to the said 1 year warranty period LegionMeterG1_USB_UGV 11 0 9 www plxdevices com
7. wn below sa O LA Press and LeaGioN Nels Release Button V1 0 meter Data Pass Through Switch When the integrated data pass through slide switch shown below is in Charge Accelerated mode A position the USB ports data lines D and D are physically disconnected This prevents any data from being transferred or synced providing ultimate safety for your data while accelerating your charge speed at the same time Howev er if you would like to enable data pass through on your Legion Meter simply move the slide switch to Data Pass Through mode D position f La HR DEVICES IN 4 www plxdevices com 4 Product Care and Maintenence Your Legion Meter is a product of superior design and should be treated with care The guidelines below will allow you to enjoy this product for years to come Storage Legion Meter should be stored at room temperature in cool or shaded areas ideally between 10 C 50 F to 25 C 77 F Safety PLX Devices Inc DOES NOT recommend disassembling this product on your own accord Disassembly of the product will result in void of warranty If you believe your unit is damaged or needs to be replaced contact technical support at www plxdevices com for inspection and replacement information Only qualified personnel should service this product Faulty service may be dangerous and may invalidate any warranty applicable to the device Exposure to Liquid or Moisture Do not
8. www plxdevices com www plxdevices com About Legion Meter Menus Five different menus may be displayed on Legion Meters OLED display These menus include Voltage Current Power Milliwatt Hour and Charge Accelerator mode selection Voltage Current and Power The Voltage Current and Power modes allow you to use Legion Meter as a multimeter for any USB port Storage Capacity The Milliwatt Hour mode is useful for analyzing the storage capacity of batteries To reset the mWh counter press and hold the user interface button while in the Milliwatt Hour mode until the counter resets to zero Charge Accelerator Mode The Charge Accelerator mode has two modes of operation Apple mode and Android mode This user selectable mode dynamically converts any USB port to optimize the charge speed by signaling your mobile device to safely draw the maximum amount of charge possible To switch modes press and hold the user interface button while in the charge accelerator mode until the screen changes as shown below NOTE Switch must be in charge accelerator A position for Charge Accelerator mode to be effective N E Press and N Too nee Display Oreintation In some cases Legion Meter s display may appear upside down to the user If you would like to change the orientation of the display press the user interface button while on the Legion Meter screen that appears when Legion Meter is initially plugged into a USB port as sho
Download Pdf Manuals
Related Search
Related Contents
LA30C & LA65C - Version 1.cdr Digital Network Public Address& Voice Alarm System Axim™ X30 [FR] - FEE DU LOGIS (Pliz) Surfaces modernes Nettoyant CR3™ • CR4™ WondeX SPT 100 Series Utility User Manual - GPS Utiliser la clé dynamométrique Dossier Accompagnateur USER MANUAL FOR PUSH BUTTON PANEL ELS01DG WITH Dorman® Power Window Regulator. Installation Copyright © All rights reserved.
Failed to retrieve file