FlowStart Evo high temperature upgrade

image

Contents

1. FlowStart Evo high temperature upgrade CAUTION Use the PEEK microreactor cartridge part of the upgrade kit If the original green cartridge is used above 140 C the cartridge will melt and may damage the FlowStart Evo The FlowStart Evo B 401 can be updated to reach 200 C The upgrade procedure below is intended for technical staff of FutureChemistry and distributors The procedure is not recommended for customers When in doubt please contact FutureChemistry 31 24 711 4029 1 Upgrade Steps 1 1 Removing B 221 or B 221 2 Some FlowStart Evos are still fitting with the 10 port version of the microreactor holder B 221 In order to use the FlowStart Evo at higher temperatures the 4 port version B 221 2 is needed In any case the first step of upgrading the FlowStart Evo to 140 C Just slide the holder to the left as illustrated on the picture below gt move holder by the left g future amp Chemistry 1 2 Replacing bolts The aluminium heating plate is attached with PVDF bolts These bolts cannot be used above 140 C and need to be replaced with PEEK version CAREFUL throughout the whole process please be careful to not shift or move the aluminum heating plate Underneath the plate Peltier elements fit into a recess so there is an edge on the bottom side of the aluminium plate If the plate is shifted the edge could rest on the top of the Peltier elements destroying the Peltier elements First remove t
2. he left PVDF bolt and replace it with a PEEK bolt Tightening the bolt will deform the heating plate a little bit This is intended tighten the bolt just enough so that the heating plate becomes completely straight again Left removing the PVDF bolt Right replacing with PEEK bolt During this phase the aluminium heating plate will be a bit warped This is indicated with the red line exaggerating When the PEEK bolt is tightened just enough the aluminium heating plate will be completely straight again Future Chemistry After this do the same with the right bolt You now will end up with a straight aluminium plate positioned level with the instrument Do the same with the right bolt If not e g if you see that the plate is not level it could mean the aluminium plate is shifted with respect to the Peltier elements In that case the plate needs complete repositioning Please contact us to help you with that User s Manual FlowStart Evo Support Future Chemistry 1 3 Replacing microreactor holder B 221 2 Now just slide the holder from the left as illustrated on the picture below Make sure the holder clicks in place lace holder by User s Manual FlowStart Evo Support Future Chemistry 1 4 Reconfigure temperature controller The temperature controller is normally configured with a maximum temperature of 140 C First switch on the FlowStart Evo and follow the steps to reach configuratio
3. lt and may damage the FlowStart Evo Future Chemistry User s Manual FlowStart Evo Support Future Chemistry FutureChemistry Holding BV Toernooiveld 1 6525 EC Nijmegen The Netherlands Tel 31 24 711 4029 Fax 31 24 89 1446 E mail support futurechemistry com COPYRIGHT BY FUTURECHEMSITRY HOLDING BV User s Manual FlowStart Evo Support
4. n level 2 The 1O button is the left most button on the controller this button is not used under normal operation 5 1 To Enter Level 2 1 From any display press and hold 2 After a few seconds the display will E uf show G0To 3 Release If no button is pressed for about 45 seconds the display returns to the HOME display l Eug 4 Press or to 5010 choose LEu C Level 2 5 After 2 seconds the rane LUJ display will show 6 Press Ca or Cy to enter the Lue pass code Default i If an incorrect code is entered the controller reverts to Level 1 Press a few times to reach the parameter SP HI Now use the B button to set the maximum temperature to 200 C Now press the 1O button to return to the home screen Switch off the FlowStart Evo and switch back on Without any microreactor placed set the temperature to 200 C The instrument should reach this temperature without any problems even though it will take some time a few minutes User s Manual FlowStart Evo Support Future Chemistry 2 Usage IMPORTANT When using the FlowStart Evo above 140 C always use the following high temperature parts High temperature cartridge PEEK part of B 450 or B 4501 High temperature inlets B 4410 and outlet B 4420 with blue or brown PEEK tubing and white ferrules CAUTION If the original green cartridge is used above 140 C the cartridge will me

Download Pdf Manuals

image

Related Search

Related Contents

リサイクル対象廃棄物(家電4品目)一覧  Command Line Interface: Industrial Wireless LAN Client BAT-C  SCALPEL 29`ER.  Manual de Usuario SIDEMAR - Servicio Nacional de Aduanas  Cadastramento do Trabalhador em Lote Procedimento - TDN  Philips DVP3120/55 User's Manual  MANUAL PURIFICADOR DE AR  F200 User Manual  MC92N0-G User Guide {English] (P/N 72E-162536-02  

Copyright © All rights reserved.
Failed to retrieve file