Home

NI 9469 Operating Instructions and Specifications

image

Contents

1. 60529 and EN 60529 gt be amp Special Conditions for Hazardous Locations Use in Europe This equipment has been evaluated as Ex nA IIC T4 equipment under DEMKO Certificate No 07 ATEX 0626664X Each module is marked II 3G and is suitable for use in Zone 2 hazardous locations in ambient temperatures of 40 C lt Ta lt 70 C If you are using the NI 9469 in Gas Group IIC hazardous locations you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4 EEx nC IIC T4 Ex nA IIC T4 or Ex nL IC T4 equipment NI 9469 Operating Instructions and Specifications 4 ni com Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility EMC as stated in the product specifications These requirements and limits are designed to provide reasonable protection against harmful interference when the product is operated in its intended operational electromagnetic environment This product is intended for use in industrial locations There is no guarantee that harmful interference will not occur in a particular installation when the product is connected to a test object or if the product is used in residential areas To minimize the potential for the product to cause interference to radio and television reception or to experience unacceptable performance degradation install and use this product in strict accordance with the ins
2. Instructions and Specifications If maximum separation distance is required connect the modules using a daisychain topology with maximum cable length per hop as shown in Figure 4 Refer to the Cable section for information about maximum cable length Topologies for mM It om 0 om Master LCE Slave Chassis 1 Slave Chassis 2 Chassis 5 n o oa o DL for po CFL pm po po pm Slave Slave Slave Slave Chassis 3 Chassis 4 Chassis 6 Chassis 7 NI 9469 Operating Instructions and Specifications Figure 2 Tree Topology 10 ni com o ox Tir CS pa for Slave Slave Chassis 7 Chassis 2 for om ml ox for pa pr Oo pa ez Slave Slave Master Slave Slave Chassis 6 ee Chassis 3 or D Dm ou oar Slave Slave Chassis 5 Chassis 4 Figure 3 Star Topology O National Instruments 11 NI 9469 Operating Instructions and Specifications fo Bn pA Oo fen fen JL offe Or Ra L m on for Oe for fom Master Slave Slave Chassis 1 Chassis 2 Chassis 3 Slave Slave Chassis 5 Chassis 6 Figure 4 Daisychain Topology NI 9469 Operating Instruc
3. 02 96 EC on Waste and Electronic Equipment visit ni com environment weee Bar RSA dE MA CPE ROHS RS E National Instruments A t EHETE So ram BAS ill 38 IO A ES ROHS RT National Instruments F E ROHS ZIL D TEESE ni com environment rohs_china For information about China RoHS compliance go to ni com environment rohs china NI 9469 Operating Instructions and Specifications 22 ni com Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request atni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office Web sites which provide up to date contact information support phone numbers email addresses and current events National Instruments 23 NI 9469 Operating Instructions and Specifications LabVIEW National Instruments NI ni com the National I
4. OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9469 Synchronization Module Fran ais Deutsch HAR SSO fP ni com manuals WwW NATIONAL P INSTRUMENTS This document describes how to use the NI 9469 and includes specifications Visitni com info andenter rdsoftwareversion to determine which software you need for the modules you are using For information about installing configuring and programming the system refer to the system documentation Visit ni com info and enter the following info codes e cseriesdoc for information about C Series and system documentation e compatibility for information about chassis and carrier compatibility for the modules you are using e xdsoftwareversion for information about which software you need for the modules you are using el Note The safety guidelines and specifications in this document are specific to the NI 9469 The other components in the system might not meet the same safety ratings and specifications Refer to the documentation for each component in the system to determine the safety ratings and specifications for the entire system Visit ni com info and enter cseriesdoc for information about C Series documentation NI 9469 Operating Instructions and Specifications 2 ni com Safety Guidelines Operate the NI 9469 only as described in these operating instructions AN Hot Surface This icon denotes that the component may be hot Touching this comp
5. Trig 2 Trig 3 Clk Gen Onboard Figure 1 Routing Capabilities of the Crosspoint Switch NI 9469 Operating Instructions and Specifications 8 nicom Note Figure 1 details hardware routing capability only 3 There may be software imposed limitations that prevent certain routing or input output function from being realized For more information refer to the documentation for your specific software platform NI 9469 Application In a basic application a single NI 9469 module is inserted into each host C Series chassis One module is set as master the remainder as slaves and all of the modules are connected with a tree topology Figure 2 shows a tree topology example More advanced and customizable options are available that enable a flexible topological network of NI 9469 modules to be achieved Refer to the Topologies section for examples of various topological networks Based on user needs certain topologies may be desired over others due to application or timing requirements Since signals are physically propagated over cabling inherent cable delays and skew exist that the module cannot compensate for If for example all slave modules must receive triggers at the same time with minimal skew and delay a star topology with short length matched cables is preferred Refer to Figure 3 for an example of a star topology configuration National Instruments 9 NI 9469 Operating
6. e chassis you are using for more information about meeting these specifications Operating temperature IEC 60068 2 1 IEC 60068 2 2 40 to 70 C NI 9469 Operating Instructions and Specifications 20 ni com Storage temperature IEC 60068 2 1 IEC 60068 2 2 40 to 85 C Ingress DrotecHon eee IP 40 Operating humidity TEC oO0o8 2261 10 to 90 RH noncondensing Storage humidity IEC 60068 2 56 5 to 95 RH noncondensing Maximum al tude 2 000 m Indoor use only Pollution Degree IEC 60664 2 Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers National Instruments 21 NI 9469 Operating Instructions and Specifications For additional environmental information refer to the NI and the Environment Web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document Waste Electrical and Electronic Equipment WEEE S EU Customers At the end of the product life cycle all products must be sent to a WEEE recycling center For more information about WEEE recycling centers National Instruments WEEE initiatives and compliance with WEEE Directive 20
7. e clock generation settings if used must be reconfigured when the module exits sleep mode and power is restored NI 9469 Operating Instructions and Specifications 14 ni com Specifications The following specifications are typical for the range 40 to 70 C unless otherwise noted 1 0 Characteristics Front panel connectors Shielded RJ45 receptacle Front panel indicators 4 green LEDs Number of Porte 3 Port 0 1 and 2 Number of input output signals 4 Line 0 1 2 and 3 per port 12 total EE Differential Maximum simultaneous OU pU S e de ee cece cece eee a eE 8 Number of I O triggers to backplane ee eeeeeseeeeeeeeeeeeeeeee 4 Trig 0 1 2 and 3 Clock Generation DDS Frequency senres eeeeeeeseeeeeee 12 8 MHz or 13 1072 MHz E EE 3 5 ppm typical O National Instruments 5 MI 9469 Operating Instructions and Specifications Cable Au CAT 5e Shielded Twisted Pair straight through Maximum propagation delay 4 98 ns m Maximum length eee 100 m Power Requirements Power consumption from chassis Active mode sesesssessesssessreereese 1 W max Sle p mode sirrien 25 uW Thermal dissipation at 70 C Active mode sesessessesesssesseesseese 1 W max Sleep Modene 25 uW Physical Characteristics 1 Refer to the 7 0 Characteristics section for more information 2 As specified for CAT 5e in TIA EIA 568 Standard NI 9469 Operating Instructions and S
8. ee RJ45 connectors on the front panel labeled Port 0 1 and 2 These connectors use standard straight through CAT Se Ethernet cabling to provide connection to other NI 9469 modules only Each port is software configurable to drive or receive 4 differential signals through the cable which are referred to as Line 0 to 3 Each port can carry either 4 triggers or 3 triggers and 1 clock in which Line 3 is dedicated to carry the clock Routing the NI 9469 The NI 9469 features a configurable crosspoint switch You can control the routing of signals and the onboard clock generator between each front port and the trigger lines in the backplane However the crosspoint switch is not a full routing matrix Only the same Line or Trig number can be connected together For example Line 0 to Trig 0 but not Line 0 to Trig 2 However clock signals can only be routed on Line 3 or Trig 3 Figure 1 details the routing capabilities of the crosspoint switch 3 Note Only 8 of the 12 total port lines are allowed to be set as outputs due to power constraints National Instruments 7 NI 9469 Operating Instructions and Specifications Destinations Port 2 Backplane Line 0 Line 0 Line 3 lt Line o Line 1 Line 2 Line 3 Line 1 Port 0 Line 2 Line 3 Line 0 Line 1 Port 1 Line 2 Line 3 Line 0 Line 1 Sources Port 2 Line 2 Line 3 Trigo Trig 1 Backplane
9. nstruments corporate logo and the Eagle logo are trademarks of National Instruments Corporation Refer to the Trademark Information at ni com trademarks for other National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data 2012 National Instruments All rights reserved 373337A 01 Junt2
10. onent may result in bodily injury A Caution If you need to clean the NI 9469 wipe it with a dry towel The product must be completely dry and free from contaminants before you return it to service A Caution Do not operate the NI 9469 in a manner not specified in the user manual or operating instructions Product misuse can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the product is damaged return it to National Instruments for repair Safety Guidelines for Hazardous Locations The NI 9469 is suitable for use in Class I Division 2 Groups A B C D T4 hazardous locations Class I Zone 2 AEx nA IIC T4 and Ex nA IIC T4 hazardous locations and nonhazardous locations only Follow these guidelines if you are installing the NI 9469 in a potentially explosive environment Not following these guidelines may result in serious injury or death National Instruments 3 NI9469 Operating Instructions and Specifications Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhazardous Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous Caution Substitution of components may impair suitability for Class I Division 2 Caution For Division 2 and Zone 2 applications install the system in an enclosure rated to at least IP 54 as defined by IEC
11. pecifications 16 ni com Safety Safety Voltages Isolation Channel to channel None Channel to earth ground None Hazardous Locations US EE WEE Class L Division 2 Groups A B C D T4 Class I Zone 2 AEx nA IIC T4 Canada CHL Class I Division 2 Groups A B C D T4 Class I Zone 2 Ex nA IIC T4 Europe DEMKO Ex nA IIC T4 O National Instruments 17 NI 9469 Operating Instructions and Specifications Safety Standards This product meets the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use e IEC 61010 1 EN 61010 1 e UL61010 1 CSA 61010 1 3 Note For UL and other safety certifications refer to the product label or the Online Product Certification section Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory use es EN 61326 1 IEC 61326 1 Class A emissions Industrial immunity EN 55011 CISPR 11 Group 1 Class A emissions e AS NZS CISPR 11 Group 1 Class A emissions e FCC 47 CFR Part 15B Class A emissions e ICES 001 Class A emissions NI 9469 Operating Instructions and Specifications 18 ni com Ei Ei Note In the United States per FCC 47 CFR Class A equipment is intended for use in commercial light industrial and heavy industrial locations In E
12. tions and Specifications 12 ni com T m DE Slave Slave Chassis 2 Chassis 3 Chassis 4 Chassis 7 wM fem e A fom ory mo a ma Master Slave Slave Chassis 6 Chassis 1 ai Chassis 8 m por por mm en It mem Slave Slave Slave Chassis 5 Chassis 9 Figure 5 Hybrid Topology O National Instruments 13 NI 9469 Operating Instructions and Specifications Activity LEDs The NI 9469 has four front panel LEDs labeled Trig 0 Trig 1 Trig 2 and Trig 3 Clk The LEDs blink when activity is detected on the corresponding line to or from the carrier Sleep Mode This module supports a low power sleep mode Support for sleep mode at the system level depends on the chassis that the module is plugged into Refer to the chassis manual for information about support for sleep mode If the chassis supports sleep mode refer to the software help for information about enabling sleep mode Visit ni com info and enter cseriesdoc for information about C Series documentation Typically when a system is in sleep mode you cannot communicate with the modules In sleep mode the system consumes minimal power and may dissipate less heat than it does in normal mode Refer to the Specifications section for more information about power consumption and thermal dissipation Notice that when the NI 9469 is in sleep mode th
13. tructions in the product documentation Furthermore any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules Caution To ensure the specified EMC performance operate this product only with shielded cables and accessories National Instruments 5 NI 9469 Operating Instructions and Specifications Special Guidelines for Marine Applications Some products are Lloyd s Register LR Type Approved for marine shipboard applications To verify Lloyd s Register certification for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product label Caution In order to meet the EMC requirements for marine applications install the product in a shielded enclosure with shielded and or filtered power and input output ports In addition take precautions when designing selecting and installing measurement probes and cables to ensure that the desired EMC performance is attained NI 9469 Overview The NI 9469 is a synchronization module for C Series platforms It has a configurable multi port interface that enables distribution of triggers and clocks from a host chassis and it has an onboard DDS and PLL for clock generation and synchronization capabilities NI 9469 Operating Instructions and Specifications 6 ni com Connecting the NI 9469 The NI 9469 has thr
14. urope Canada Australia and New Zealand per CISPR 11 Class A equipment is intended for use only in heavy industrial locations Note Group 1 equipment per CISPR 11 is any industrial scientific or medical equipment that does not intentionally generates radio frequency energy for the treatment of material or inspection analysis purposes Note For EMC declarations and certifications and additional information refer to the Online Product Certification section CE Compliance C This product meets the essential requirements of applicable European Directives as follows e 2006 95 EC Low Voltage Directive safety e 2004 108 EC Electromagnetic Compatibility Directive EMC National Instruments 19 NI 9469 Operating Instructions and Specifications Online Product Certification Refer to the product Declaration of Conformity DoC for additional regulatory compliance information To obtain product certifications and the DoC for this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column Shock and Vibration To meet these specifications you must panel mount the system Operating vibration Random TEC 60068 2 64 5 Sims 10 to 500 Hz Sinusoidal TEC 60068 2 6 5 g 10 to 500 Hz Operating shock TEC oe 220 30 g 11 ms half sine 50 g 3 ms half sine 18 shocks at 6 orientations Environmental Refer to the manual for th