1. Press any key to boot from CD or DVD system will boot from CD to launch Windows installation 3 Configure according to actual needs Language to install Time and currency format Keyboard or input method and then click lt Next gt to continue 4 Click lt Install now gt on installation confirmation interface to continue 5 If Load Driver window pops up it indicates A Required CD DVD drive device driver is missing If you have a driver floppy disk CD DVD or USB flash driver please insert it now Note Ifthe Windows installation media is in the CD DVD drive you can safely remove it for this step Now it is required to load a hard disk controller driver If you use a USB floppy disk please insert a floppy disk into floppy driver If you use an Inspur drive U disk or a normal U disk please confirm U disk connection is correct Then click lt Browse gt button select path of the drive click lt OK gt system will search drivers automatically 6 On Select the driver to be installed interface select the driver to be installed and then click lt Next gt to start driver loading 7 On Type your product key for activation interface input your Product Key 25 characters and then click lt Next gt to continue 8 On Select the edition of Windows that you purchased interface select the edition of operation system to be installed and then select I have selected the edition of Windows that I pur
2. on self check hard disk state 2 If the power on self check can detect the hard disk but the hard disk can t be detected when installing the system it may be caused by the following conditions e If you are using the system CD to boot and install the operating system directly the hard disk drive is generally added through the floppy driver or Inspur driver U disk When using USB floppy driver to add the drive please set the BIOS first and close the onboard floppy driver controller When using Inspur driver U disk to add the drive please connect Inspur driver U disk when starting the server e Please check whether the driver having been made is correct or not the drive Chapter Six Install Operating System for external RAID card should be made directly from the attached RAID card driver CD and whether there is fault in the floppy disk or Inspur driver U disk 6 2 4 Instruction of Onboard SATA Controller If it is configured onboard SATA HostRAID it only supports windows system of above Windows XP versions and connects 6 SATA devices at most 6 2 5 Keyboard and Mouse Do Not Work 1 Check whether the cable joint of the mouse and keyboard is plugged and connected correctly Make sure the joint pin has no curve 2 Check whether the mouse setting in the control panel of the operating system is correct or not 3 Clean the scrolling and drive shaft of the mouse 4 It is suggested that you use the keyboard and mouse tested for compa
3. s no volume created at present there re four volume levels of RAIDO Stripe RAID1 Mirror RAID10 RAIDO 1 and RAIDS Parity for selection please select volume level according to actual needs RAIDO It is allowed to use 2 or more hard disks to make this RAID volume RAIDI1 It is allowed to use 2 hard disks to make this RAID volume RAID10 It is allowed to use 4 hard disks to make this RAID volume this option is only available when the number of hard disks is 4 or above RAIDS Parity It is allowed to use 3 or more hard disks to make this RAID QD Chapter Four SATA RAID Setting ES volume Disks To select hard disks to make RAID volume select this option and press Enter system enters hard disk select interface please use Space to select hard disks accordingly to make RAID volume and then press enter to return to volume create menu Strip Size Please select volume size this option is only available on RAIDO and RAIDS volumes Capacity Please set volume capacity which is the maximum capacity by default After the above settings are done please select Create Volume and press Enter system prompts WARNING ALL DATA ON THE SELECTED DISKS WILL BE LOST Are you sure you want to create this volume Y N To create RAID volume please enter Y volume will be created meanwhile data on the selected hard disk will all lose Otherwise please enter N to exit volume create Here we enter
4. t change the ground joint in the cabinet unless it is of absolute necessity Temperature if installed in the cabinet the operation and working temperature of the server can t be lower than 5 C and higher than 35 C Ventilation the cabinet used by server cluster must provide enough wind current for the front of the server to ventilate and must ensure 4100Btu heat discharge per hour The cabinet selected by the cluster and ventilation condition must correspond GD with requirements of the server Chapter One Safety Information SS 8 2 Components Needed in Server Installation Accompanying guide rail suit of1U server includes the following objects 1 Front frame 2 Back frame 2 3 Outer rail 2 4 Middle rail 2 5 Inner rail 2 6 Frame fixing screw nut lock catch 2 wraps 7 Frame fixing screw 1 wrap Inner rail middle rail outer rail front frame and back frame have been fixed together beforehand One wrap of frame fixing screw nut lock catch includes 4 and one wrap of frame fixing screw M6 includes 10 Frame fixing screw s 2 Frame fixing screw nut lock catch Inner rail Front frame Outer frame Back frame Middle rail Figure 8 1 8 3 Install Guide Rail into Cabinet 1 Make sure the installation location of the guide rail on the cabinet which needs 1U space shown in figure 8 2 2 Fix the frame fixing screw nut lock catch on the fixed hole of the angle rail from the inner side of the angl
5. prevent damage to the components or scratching of the arms Carefully deal with the components and plug in cards and please never touch the components or connection points on the plug in cards When taking the plug in cards or components you should grab the edges of the plug in cards or components or lt gt Chapter One Safety Information o their metal fixed supports 8 During the process of cabinet installation and application please pay attention to the following matters After the installation of cabinet is finished please ensure that the supporting feet have been fixed to the rack and supported to the ground and all weight of the rack have been fell onto the ground It shall install into the cabinet according to the sequences from the bottom to the top and first install the heaviest component When pulling out the components from the cabinet it shall apply force slightly to ensure the cabinet to keep balance and stabilization When pressing down the release latch of the sliding rail of components and sliding in or out please be careful as the sliding rail may hurt your figures Never make the AC power branch circuit in the cabinet overload The sum of cabinet load shall not exceed 80 of the ratings of branch circuits Ensure that components in the cabinet have good ventilation When repairing components in the cabinet never step on any other components Chapter Two Product Introduction Chapter T
6. the following settings Enabled Default Open integrated SAS controller Chapter Three System Setup O D Disabled Close integrated SAS controller Onboard SAS Oprom This option is used to open or close integrated SAS controller ROM there re two options of Enabled and Disabled default settings When SCU devices option is set to Disabled this option will be hidden automatically When this option is set to Disabled it could be used as a storage drive via connecting 4 SATA hard disks If it is required to connect SAS hard driver use connected SATA hard drives system disk this option should be set to Enabled Onboard SATA RAID Oprom This option is used to open or close integrated SATA RAID controller ROM there re two options of Enabled default settings and Disabled ME Subsystem This menu is used to set ME subsystem ME Subsystem This option is used open or close ME subsystem when set to Enabled default users could view related ME information IV Server Mgmt Menu Wait For BMC This option is used to set whether to wait for BMS startup there re two options of Enabled and Disabled default settings System Event Log This menu is used to set system even log features modification on settings made in this menu could only validate after reboot SEL Components This option is used to set whether to record all event logs during system startup there re two option
7. Chapter Six Install Operating System o 6 3 Machine Alarm If there s machine alarm in startup or utilization process please refer to the following measures 1 If this happens after you plugged in some external board you may need to pull off this device and to do another test If the alarm goes off it shows that your external board is incompatible with the machine It is suggested not to use it any more if the alarm is still on please go on referring to the following steps 2 Locate the alarm sound e When the alarm sound is from the front of the chassis usually we notice abnormal changes of the fault indicating light There is the possibility of abnormal fans or hard disk module e If the alarm sound is from the rear of the chassis please check whether a redundant power supply is configured or not and whether there is an abnormal status light of the power supply module or a module without power cable when power alarm goes on the shield switch can be pressed to stop it e If the alarm sound is in the chassis the alarm may be from motherboard RAID card or hard disk back plane If it is also accompanied by no display on the monitor or power on faults there is high possibility of something wrong with motherboard You can try to pull or plug RAM or clear CMOS if the starting self check is normal and the alarm starts when the RAID card is under test and there is abnormal array information then it is likely that the RAID card has se
8. Considering the height and weight of the chassis at least two people are needed to complete its movement Warning 12 Declaration The product is Grade A product and in the living environment it may cause D Chapter One Safety Information o radio interference In such case it may need the user to take feasible measures for the interference Notes In order to help you use the equipment the following considerations can help avoid the occurrence of problems that may damage the components or cause data loss 1 In case of the following cases please unplug the power line plug of products from the power socket and contact the customer service department of Inspur The power cables extended cables or power plugs are damaged The products get wet by water The products have fallen off or been damaged Objects fall into the products When operating according to the operation instructions the products cannot function normally 2 If the system becomes damp please treat it according to the following steps Switch off the power supplies of the system and the equipment disconnect them with the power socket wait for 10 to 20 minutes and then open the cover of the host Move the equipment to the ventilation place to dry the system at least for 24 hours and make sure that the system is fully dried Close the cover of the host re connect the system to the power socket and then start the equipment In case of operat
9. Integrated Management Card eee You could also use an Inspur driver CD enter java directory under CD root Java SE Runtime Environment 6 and Update 18 plug in based on Windows system are provided and install browser plug in directly Please install browser plug in on client before login remote desktops 7 2 2 Remote Login Method Enter BMC IP address in IP address field of client browser press Enter management login interface will display as shown in the following figure Please enter default administrator name Username and password Password Username admin Password admin Note Users could carry out configuration of all modules and set rights via default username and password in order to guarantee system security it is suggested to modify login password after login 7 2 3 Function Menu Introduction Default displayed interface after login is as shown in the following figure Dashboard FRU Information Server Health Configuration Remote Control Maintenance Dashboard F Dashboard gives the overall information about the status of the device and remote server L Device Information Sensor Monitoring Firmware Revision 1 1 0 Firmware Dulid Time Dec 28 2012 15 41 15 CST Status Sensor Reading munasa o wee Network Information Ean CPU Saus 10K P MAC Address 60 92 8F05 00 0E Momor Sisus 10K A V4 Network Mode DHCP Powert_status 10K A IPva Address 10 5211 163 z V6 Network Mode DHCP Po
10. Layout Menu in remote desktop C Remote desktop Mouse menu Video Keyboard Mouse Options Media Keyboard Layo Video Recor Power Active User Help Zoom Size 110 S A Z Show Cursor ac gam es B n 3 J m O i 50 100 150 Q O Mouse Calibration Mouse Mode Menu Functions Select this option to display local mouse on remote desktop h f Snow Cu rgoi synchronously and redirect mouse on the picture Mouse Mode Select this option to set mouse mode D Remote desktop Options menu Video Keyboar Mouse Options Media Keyboard Layo Video Recor Power Active User Help Zoom Size 110 7 m A C Bee i l E 50 TA 150 T O J Keyboard Mouse Encryption Zoot Bandwidth Select this option to set to display bandwidth Keyboard Mouse Encryption Keyboard Mouse encryption setting Select this option to zoom in out remote desktop display Zoom window Zoom In means to enlarge display window while Zoom Out means to reduce display window E Remote desktop Media menu Click Media menu Virtual Media Wizard window will display use this window to load client floppy mirror CD mirror and CD drive as shown in the following figure GS Chapter Seven Use Instructions on Management Functions of Integrated Management Card E Virtual Media e ew a Floppy Key Media
11. Up and Down arrow buttons to select this menu and then press Enter to enter this menu System prompts Are you sure you want to exit Y N enter Y system exits SATA HostRAID configuration interface enter N to cancel exit operation Chapter Six Common Problems and Trouble shooting Chapter Five Operation System Installation This chapter mainly introduces manual installation of mainstream operation system on this server Rui Jie server kit supports intelligent automatic installation of mainstream operation systems of Windows and Linux Actual supported operation systems are those in dropdown list in lt Select the Operating System gt automatic installation of these operation systems may not be supported by certain configuration of the server and you may need to install operation systems of other editions manually according to actual requirements During manual operation of operation system some operation systems may need a floppy drive or Inspur drive U disk to load hard disk controller drive for methods to make a floppy drive see readme pdf under root directory in Inspur drive CD if the configuration purchased is integrated with Inspur drive U disk for the making of a drive U disk please see related content in this chapter If the server is configured with an external RAID card or SAS card please refer to electronic user manual in external RAID card or SAS card CD to add a hard disk controller drive As
12. Use All Space Replace Existing Linux System s Shrink Current System Use Free Space Create Custom Layout Here custom manual partition is taken as an example select Create Custom layout and click Next to continue 12 Installation enters installation hard disk selection interface in Data Storage Devices to be mounted only list system displays storage devices detected Please click the hard disk to install system according to actual needs add this hard disk under the Install Target Devices list select a hard disk as Boot Loader and then click Next to continue 13 Installation program enters Please Select A Device partition create interface if a partition has been created on hard disk existing partition will be displayed and this partition could be deleted if not necessary Select Free partition or another existing partition under the hard disk click Create Create Storage window will pop up select partition type to be created according to actual needs and then click Create Add Partition will pop up Chapter Six Common Problems and Trouble shooting create a partition according to actual needs Create root partition and boot partition Select root partition in Mount point select the hard disk to install system in Allowable Drives windows enter partition size in Size MB and click OK to complete creation or root partition Create boot partition in the same wa
13. interface automatically 2 Select in Select OS column Windows 2008 3 Select in Select Hardware column Network card driver 4 Click lt Next gt to install 5 Enter Intel Network Connections interface double click the Install Drivers and Software option 6 Enter Welcome to the InstallShield Wizard for Intel R Network Connections interface click lt Next gt to continue 7 Enter License Agreement interface select I accept the terms in the license agreement and then click to continue 8 Enter Setup Options interface click lt Next gt to continue 9 Enter Ready to Install the Program interface click lt Install gt to continue GD Chapter Six Common Problems and Trouble shooting 10 Installation starts after installation completes click lt Finish gt according to prompt 18 Install video driver After network card driver installation completes do not exit driver CD installation interface and continue to install display card driver 1 Select in Please select operation system column Windows 2008 2 Select in Please select component Video driver 3 Click lt Next gt to start installation 4 Enter Welcome to the InstallShield Wizard interface click lt Next gt to continue 5 Enter License Agreement interface select I accept the terms in the license agreement and then click lt Next gt to continue
14. is introduced We suggest you read this manual seriously before you use this server in case of the unnecessary faults in your operation Content Chapter One Safety Information 0 cece ecceeseeeceeseeeeeeeneeeneceneseeeeneeeneeeneees Chapter Two Product Introduction 0 cc ccceecceeseesceeeeeeneeeneeeneeeneeneeeneeeneeees 2 1 Server Technical Specification cccccceesscesseeeseeeseeeeseeeeseeenseesseeensreeees 2 2 Front Panel VIEW vyseesecses cvsaesacevssactsec cssevsedsecevlaessscvdactedvscevdadssseveeseacvacevlans 23 BACK Panel VAC W asses fe seats hep fas cb ads teed tas Seared dees teed dep uaes ao iaevtandde dies vantiass 2 4 RJ45 Interface Network Card Indicator Introduction 0 0 0 eeeeeeeeeteees Chapter Three System Setup cccccccssccessessceceseeeeseeeseeeseeesseecnsessseeessneeees 31 Mainboatd BIOS Stu wcccsssiascicedsssankeayiess davies dankeaa ays gantedosdauresieasiaaniedsi 3 2 Mainboard Jumper Seine c ccoissiteinsedisdigeesdagieveteels ieceassnaeeueeeeheetvas Chapter Four SATA RAID Setting 00 cece cccccceereceteeeeneeeeeeeneeenseeensneeees 4 1 How to Enter SATA HostRAID Configuration Interface eee 4 2 Application of Control Buttons cc eeeceeseeneeeneceeeeseeeseeeaeeeaeeaeeeaeeeaeees 4 3 SATA HostRAID Configuration ccccceccsecesceeeseeeseeeeseeesseeenseesneeessneeee Chapter Five Operation System Installation cece eeseeeeeeeeeeeeeeeeeee
15. is required to enter user password in BIOS Setup configuration interface user will have the same rights with those of administrator after entering user password VII Save amp Exit Menu Options in this menu could realize saving or abandoning BIOS setup modification and could exit setup program Save Changes and Exit Select this option press Enter and select Yes in prompt popped up all modifications in BIOS Setup will be saved and system will exit BIOS Setup Function of this menu could be realized using shortcut key F10 Discard Changes and Exit Select this option press Enter and select Yes in prompt popped up all modifications in BIOS Setup will be discarded and system will exit BIOS Setup Save Changes and Reset Select this option press Enter and select Yes in prompt popped up to save modification in BIOS exit BIOS settings and then restart the computer Discard Changes and Reset Select this option press Enter and select Yes in prompt popped up all modifications in BIOS Setup will be discarded and system will exit BIOS Setup then restart the computer Save Changes Select this option press Enter and select Yes in prompt popped up all modifications in BIOS Setup will be saved and system won t exit BIOS Setup for this action Discard Changes Select this option press Enter and select Yes in prompt popped up all modifications in BIOS Setup will be discarded and
16. possible Note Some options in BIOS could not be set such as system self checking and configuration information Some options have a right arrow at the front indicating if this option is selected a cascade menu which is sub menu will display on the screen via pressing Enter 3 1 2 BIOS System Menu Introduction This section introduces the following main function menus in BIOS Menu Name Menu Functions Main Configure basic system setup i e system time system date display BIOS information etc Advanced Configure advanced features of CPU and integrated SATA controller etc Chipset Configure memory mode and CPU properties etc Server Mgmt Configure server management function Boot Configure boot sequence of system equipment Security Configure system super user and user password Save amp Exit Save BIOS setup and exit BIOS setup etc Button introduction Description Down Select the previous menu or value Select the next menu or value lt Left Select the left menu or value Right Select the right menu or value Esc Button Return to the previous menu or main menu Button Change option value Change current option value of the menu to the previous option value This button only displays values related to selected options rather than all option values Button Change option value Change current opt
17. required to delete all partitions on hard disk and create a new partition on hard disk U disk will not occupy any disk by then If hard disk is not partitioned it is required to create 1 disk partition on unpartitioned space and delete this new disk partition U disk will not occupy any disk by then and then create a disk partition according to actual needs complete installation of operation system according to prompts Note Make sure to distinguish U disk and hard disk do not delete or format U disk 5 2 Install Windows Server 2008 R2 Manually 5 2 1 Preparation before Installation e Windows Server 2008 installation DVD e Inspur Driver CD e Hard disk controller drive floppy disk external LSI 2108 RAID configured for Windows Server 2008 R2 installation does not need any driver e If a USB floppy disk is used for the above drivers please make the driver into a floppy disk if an Inspur drive U disk is used please make the driver into Inspur drive U disk if a normal drive U disk is used during driver make enter normal U disk and save category according to prompts and make driver into a normal U disk GD Chapter Six Common Problems and Trouble shooting o D 5 2 2 Installation Steps 1 Connect USB floppy disk or Inspur drive U disk or normal U disk power on server put Windows Server 2008 installation CD into the drive enter BIOS to configure and enable the server to boot from CD 2 Press any key when system prompts
18. router IP address etc manually when set to Dynamic default it is not required to set the above options User Configuration Options under this menu are used to set username for remote login IPMI management interface user privilege whether username is available or not and to change user password etc V UserID To set user group there re five options of Anonymous ADMIN Userl User2 and User3 When set to admin user group user privilege whether user is available or not options could not be changed only password could be set When set to Anonymous only user privilege whether user is available or not could be set Y Privilege To set user privilege of this user group there re three options of USER OPERATOR and ADMIN Chapter Three System Setup o Vv User Status To set whether user is available or not there re two options of ENABLE and DISABLE Y User Name To set username of user group user name length should be at least 4 bytes not exceeding 15 bytes Y PASSWORD To set login password of username for this user group password length should be at least 4 bytes not exceeding 15 bytes It is required to reboot system after modification on this option is done wait till BMC status indicator flashes and BMC operates normally System Health Information Enter this menu to view information such as CPU temperature temperature of memory slot installed with memory PCH temperature sys
19. system won t exit BIOS Setup for this action Chapter Three System Setup o D Restore Defaults Select this option press Enter and then select Yes to confirm system default optimization will be loaded while system won t exit BIOS Setup Function of this menu could be realized using shortcut key F9 Save as User Defaults Select this option press Enter and select Yes to confirm saving set values of current BIOS options as user default options Restore User Defaults Select this option press Enter and select Yes to confirm user default value will be loaded Boot Override Select device options in this menu and then press Enter to confirm it will guide system from equipment selected 3 2 Mainboard Jumper Setting Mainboard jumper setting is to short circuit two pins of the jumper to change interface function see the following figure so as to adjust mainboard functions WU vs Bac J Jumper Cap Settiie eee TTEA E BE Select to short circuit pin 1 2 Jumper Setting Figure 3 2 1 Open Case Top Panel If the following operation is required please obtain authorization of Inspur Group Co Ltd first open top panel of the case detailed steps are as follows 1 Shut down the system disconnect AC power cable 2 Loosen two bolts at the back of case top panel 3 Vertically press down card slots on case top panel with two thumbs and push QCD Chapter Three System S
20. 1 i T Floppy image aueteaesied Connect Floppy CD DVD Media1 ISO Image Browse Coonan CoD OG Hard disk USB Key Media1 HDIUSB Image ponosne Connect Hard disk USB Key PhysicalDrive0 Z C D E F Fixed Drive Status Target Drive Connected To Read Bytes Virtual Floppy 1 Not connected na Virtual CD 1 Not connected n a Virtual HardDisk 1 Not connected nla cose Select mirror type to be loaded if it is a floppy mirror please select Floppy Image if it is a CD mirror please select ISO Image and then click Browse to select mirror location and then click corresponding Connect button to complete mirror loading If CDs in synchronized client CD drive are startup CDs or system installation CDs please set client CD as the first boot sequence in server BIOS settings Installation method of ISO files is the same with that via remote CDROM so it is required to set boot sequence in server BIOS settings F Remote desktop Keyboard layout menu Menu Functions Auto Detect Select this option to detect keyboard type automatically Use soft keyboard there will be keyboard types of multiple SofiKeyboard languages for selection G Remote desktop VideoRecord menu Select VideoRecord menu to set options related to video records Start Record Select this option to start video recording Stop Record Select this option to stop video recording This option is us
21. 6 Enter Customer Information interface please input User Name and Organization and then click lt Next gt to continue 7 Enter Setup Type interface please select installation type there re two options of Complete and Complete select Custom here and click lt Next gt to continue 8 Enter Custom Setup interface click lt Next gt to continue 9 Enter Ready to Install the Program interface click lt Install gt to install display card driver 10 Installation starts and then completes on Install Shield Wizard Completed interface please click lt Finish gt a window pops up indicating to reboot the server to make the setting effective take out all disks in drivers and select lt Yes gt to reboot the server Note During installation of the above video driver for different editions of installed 08 system some installation steps may be different please refer to actual installation 5 3 Install Red Hat Enterprise Linux 6 3 Manually 5 3 1 Preparation before Installation e Red Hat Enterprise Linux 6 3 installation CD 1 DVD in this case it is 64bit e Inspur driver CD e External RAID driver for Red Hat Enterprise Linux 6 3 2108 RAID card does not need driver Chapter Six Common Problems and Trouble shooting az e If a USB floppy drive is used by the above drivers please make the driver to a floppy disk if an Inspur drive U disk or normal U disk is used please ma
22. Dear users of Inspur server Sincerely thank you for selection of Inspur server This manual introduces the technical characteristics and the system installation and setup of the server and helps you to particularly understand and expediently use this server Please deliver the package of our product to the waste recycling station for recycling in favor of pollution prevent and benefit the humankind This manual is the property of the Inspur Group Co Ltd This User Manual is not to be copied by any group or person in any manner without the consent of Inspur Group Co Ltd The Inspur Group Co Ltd reserves the right of revise this manual momentarily Any alteration about the content of this manual will be noticed Please contact Inspur Group Co Ltd if you have any questions or advice about this manual Inspur Group Co Ltd Jun 2013 Inspur is registered trademark of Inspur Group Co Ltd Other trade marks belong to other corresponding registered companies Statement Please read the following statement before you use this server formally Only when you have read this statement hereinafter and agreed the following terms you can formally use this server If you have any questions about the following terms please contact our supplier or us directly If you have no questions about these terms and start to use this server it acquiesces that you have agreed the following terms 1 We must call your attention that you
23. E Mode When this option is set to Enhanced it could support 4 SATA 3 0Gb s devices Serial ATA Controller 1 This option could only be used when SATA Mode option is set to IDE Mode When this option is set to Enhanced it could support 2 SATA 3 0Gb s devices Port0 1 2 3 4 5 Hot Plug This option could only be used when SATA Mode option is set to AHCI Mode or RAID Mode SATA interface could be set to support hot plugging or not including two options of Enabled and Disabled default SAS Configuration Enter this option to view devices connected to all SATA interfaces and to set SATA controller USB Configuration This menu is used to set options related to USB and to display USB devices automatically detected by system Legacy USB Support For USB support settings under traditional environment there re three options of Enabled default settings Disabled and Auto Ifsetto Auto USB device is not supported by default under traditional environment when no USB device Chapter Three System Setup O is connected Onboard LAN Configuration Launch PXE Oprom This option could open or close PXE function of integrated network card there re two options of Disabled and Enabled default settings When this option is set to Enabled it is required to set related network card of PXE function to Enabled HI Chipset Menu CPU Advanced Settings This menu is used to set related
24. QPI information PCIE slot transmission rate and related memory options etc IOH Configuration This menu is used to set VGA boot sequence and transmission rate of all PCIE slots supported by CPU Y Intel R I O0AT This option is used to open or close Intel I 0 accelerating technology There re two options of Enabled and Disabled default settings Y VGA Priority This option is used to set priority of integrated display card and external display card options include Offboard default External display card is the prior device Onboard Mainboard integrated display card is the prior device Vv IOH PCle Link Speed Control PCIE_0 PCIE_1 PCIE_2 PCIE_3 PCIE _4 PCIE_5 Link Speed Control Sets transmission rates of PCIE _0 PCIE_1 PCIE _2 PCIE 3 PCIE 4 PCIE_5 slots respectively including three options of GEN3 default GEN2 and GEN1 1 QPI Configuration Submenu option of this menu could be used to set options such as QPI speed mode and frequency etc If it is single CPU configuration when QPI Link Speed Mode option is set to Fast actual display status of Current QPI Link Speed will be Slow DIMM Information This menu is used to view installation slots of system memory supported CPU Chapter Three System Setup ES and memory volume information Y Memory Mode Set memory mode there re 4 options of Independent Mirroring Lock Step and Sparing If memory configur
25. Y to create an RAID volume after creation is done system returns to SATA HostRAI configuration interface and displays the created RAID volume in RAID volume list II Delete RAID Volume Menu After entering SATA HostRAID configuration interface we could use Up and Down arrow buttons to select this menu and then press Enter to delete RAID volume menu System prompts Deleting a volume will reset the disks to non RAID Warning ALL DISKS DATA WILL BE DELETED To delete RAID volume please press DEL system prompts ALL DATA IN THE VOLUME WILL BE LOST Are you sure you want to delete Volume Y N again to delete this RAID volume please enter Y to cancel the deletion of RAID volume please enter N HI Reset Disks to Non RAID Menu After entering SATA HostRAID configuration interface users could use Up and Down arrow buttons to select this menu and then press Enter to enter this menu System will display all hard disks in RAID volume please select hard disks to be reset using Space according to actual needs and then press Enter to reset these hard disks system prompts whether you want to reset hard disk input Y or N Chapter Four SATA RAID Setting according to prompt Note during hard disk reset all data on the hard disk will be lost meanwhile this hard disk will no longer belong to RAID volume IV Exit Menu After entering SATA HostRAID configuration interface use
26. ailed information of system currently installed CPU Hyper threading CPU hyper threading function setting includes two options of Enabled default and Disabled Active Processor Cores Enable call CPU cores including five options of AN default 1 2 4 6 Intel R Virtualization Technology CPU virtualization technology support setting there re two options of Disabled and Enabled default CPU Power Management Configuration This option could carry out CPU power consumption management e SATA Configuration as Chapter Three System Setup Enter this option to view SATA devices connected to all SATA interfaces and to carry out SATA controller mode and settings on all SATA interfaces SATA Mode This options is used to set the mode of mainboard integrated SATA controller there re four options of Disabled IDE Mode AHCI Mode and RAID Mode While using mainboard integrated SATA controller if it is required to use serial device as parallel IDE storage device please set this option to IDE Mode While using mainboard integrated SATA controller if it is required to connect 1 6 SATA devices without RAID please set this option to AHCI Mode While using mainboard integrated SATA controller if it is required to make integrated SATA HostRAID please set this option to RAID Mode Serial ATA Controller 0 This option could only be used when SATA Mode option is set to ID
27. ard 1 interface 1350 Network Card 1 Interface Can be used as a mainboard to integrate IPMI reuse management interface 1350 Network Card 2 Interface Integrates Intel 1350 network card 1 interface Chapter Two Product Introduction Mainboard integrates special interface for IPMI management IPMI Management Interface USB Interface Connects USB interface device VGA Interface Connects VGA interface display device Can externally connects to Low Profile half height PCI and PCI E Extension Slots PCL and PCIE extension cards 2 4 RJ45 Interface Network Card Indicator Introduction Active Indicator Rate Indicator RJ45 Interface Network Card Indicator Indicator Name Color Indicator Status Function Description Off Network disconnected Active Indicator Yellow On Network connected Flash Network communicating Orange On 100Mbit s data transmission Rate Indicator Green On 1000Mbit s data transmission Chapter Three System Setup o Chapter Three System Setup This chapter introduces BIOS function setup and mainboard jumper of the server All operations described in this section are only limited to operators or administrators with system maintenance qualification 3 1 Mainboard BIOS Setup BIOS is a basic input and output system The system parameter and the hard drive parameter can be adjusted through special set program BIOS has great influence on the system start and running s
28. are packages of Desktop X Windows System and Development in Desktops 18 Installation starts to build file system and copy files 19 Installation enters Congratulations your Red Hat Enterprise Linux installation is complete Interface indicating system has been installed successfully Click Reboot take out installation CD system will restart Chapter Six Common Problems and Trouble shooting 20 System enters Welcome interface after reboot click Forward to continue 21 Installation enters License Information interface select Yes I agree to the License Agreement click Forward to continue 22 Installation enters Set Up Software Updates interface click to continue Forward installation 23 Installation enters Create User interface user could set password add a new user according to actual needs and then click Forward to continue 24 Installation enters Date and time interface please set the correct time and date and then click Forward to continue 25 Installation enters Kdump setting interface set according to actual needs and then click Finish to complete installation 26 Enter Username and Password to login Chapter Six Install Operating System Se Chapter Six Common Problems and Trouble shooting This chapter focuses on the common problems and trouble shooting of the server If you are not sure about the cause of a failure and its removal method please co
29. ation of the system supports Mirroring and Sparing functions status of these two function modes displayed above this setting option should be Supported otherwise it should be Not Possible In order to realize Mirroring memory mirroring function for single CPU allocate memory on all channel memory slots supported by CPU_O memory of the same number installed on each memory channel could realize memory mirroring among 4 memory channels Under this mode actual available system memory volume reduces by half Y DDR Speed This option is used to set DDR speed If 4Rank memory of DDR3 1066 1333MHz is configured in the system and when this memory is installed on the 1st DIMM of the first memory channel system memory speed will be limited to 800MHz and Force DDR3 1066 1333 is disabled PCH This menu is used to realize display of related PCH chip information and parameter settings SMBus Controller This option is used to open or close system bus controller there re two options of Enabled default settings and Disabled Restore AC Power Loss This option is used to set system status for power on after abnormal power off including the following setting options Power Off default Power off status which requires to be started manually Last State Status before power off Power On Power on status SCU devices This option is used open or close mainboard integrated SAS controller including
30. bles of the system and peripheral equipment are correctly connected to the earthed power socket Please connect the three core power line plug to the three core AC power socket that is well earthed and easy to access be sure to use the earthing pin of power lines and do not use the patch plug or the earthing pin unplugged with cables In case of the earthing conductors not installed and it is uncertain whether there are appropriate earthing protections please do not operate or use the equipment Contact and consult with the electrician please Warning 6 To avoid short circuit of internal components and fire or electric lt gt Chapter One Safety Information shock hazards please do not fill any object into the open pores of the system Warning 7 Please place the system far away from the cooling plate and at the place with heat sources and be sure not to block the air vents Warning 8 Be sure not to scatter food or liquid in the system or on other components and do not use the product in humid and dusty environment Warning 9 The replacement of batteries with those of another model may cause explosion When replacement of batteries is required please consult first the manufacturer and choose batteries of the same or a similar model recommended by the manufacturer Do not dismount extrude and pink the batteries or make the external connection point short circuit and do not expose them in the environment over 60 C Never throw them i
31. chased click lt Next gt to continue 9 On interface you could understand Microsoft software license terms and select I accept the license terms option after reading then click lt Next gt to continue 10 On Which type of installation do you want interface select installation type here it is the first installation by default select Custom method to continue 11 System enters Where do you want to install Windows interface existing partitions and unpartitioned spaces on this computer are displayed click lt Drive GD Chapter Six Common Problems and Trouble shooting options gt to carry out the following operations Select an existed disk partition and then click lt Delete gt to delete Select an existed disk partition and then click lt Format gt to format Select an unpartitioned disk space and then click lt New gt to create a new partition You could carry out operation according to actual needs Here we take no partition created on disk for example 1 Select an unallocated space on disk then click lt New gt delete numbers in Size input box input disk partition size unit is MB to be created and then click lt Apply gt to continue if a confirmation window pops up click lt OK gt to continue Note It is suggested the partition shall be above 30GB 2 Select the newly created disk partition and then click lt Format gt click lt OK gt in confirmation interface to
32. continue 3 After formatting partition click lt Next gt to continue 12 System starts to install Windows and system will complete operations such as Copying files Expanding Windows files Installing features Installing updates and Completing installation etc during this process system may reboot for several times automatically 13 After installation completes system will boot to The user s password must be changed before logging on the first time interface take out installation CD and click lt OK gt to continue Note The above installation steps of Windows Server 2008 operation system may be different for different editions of system CD used please carry out operation according to actually displayed interface 14 Set Administrator password according to prompt and then click the arrow on the right of password input box if the password complies with requirement system will prompt Your password has been changed and then click lt OK gt to confirm the password has been changed Windows Server 2008 requires a strong typed password so password shall contain letters numbers and special characters otherwise the setting will not succeed 15 After login on Initial Configuration Tasks interface select Do not show this window at logon under below and then click lt Close gt on Server Manager interface newly popped up select Do not show me this console at l
33. ction 3 After selecting corresponding operation system and controller drive to make according to actual needs click lt Next gt button to make corresponding driver Driver making interfaces and methods will be different for different operation systems selected e Windows System Driver Make During driver make of Windows OS copy the drive into analog floppy disk A of Inspur drive U disk directly Select Windows edition and drive to make and then click lt Next gt The following prompt appears Please confirm Inspur drive U disk has been correctly connected and format analog floppy disk A of Inspur drive U disk then click lt OK gt to start driver make Make Driver Inspur driver U disk Chapter Six Common Problems and Trouble shooting After driver make completes a window will pop up indicating driver make is done click lt OK gt to complete driver make Make Driver Inspur driver U disk EJ Driver has been completed e Notes for Loading Driver Using Inspur Drive U Disk under Windows System During installation of Windows operation system if you load hard disk controller driver using Inspur drive U disk enter disk partition interface Inspur drive U disk will occupy a disk if the hard disk is not partitioned U disk will occupy disk C otherwise U disk will occupy another disk Please distinguish according to actual hard disk partition If there s any other partition on hard disk it is
34. e users need to adopt feasible measures to the interference 9 The copyrights of the markers and names of the software and hardware product referred in this manual are the property of corresponding companies 10 In the above statement us indicates the Inspur Group Co Ltd The Inspur Group Co Ltd holds the right of final explanation about the above statement Regarding the Manual e Chapter One Safety Information In this chapter safety information regarding server usage is introduced e Chapter Two Product Description In this chapter the technical characteristics appearance characteristics and I O interface technical specification of this server are introduced e Chapter Three System Setup In this chapter the setup of jumper wire and the system BIOS of this server is introduced e Chapter Four SATA RAID Setup In this chapter how to set up the RAID of the onboard SATA controller is introduced e Chapter Five Operating System Installation In this chapter how to install the prevailing operating systems to the server is introduced e Chapter Six Common Problem and Trouble shooting In this chapter solutions of some common problems are introduced e Chapter Seven Use Instructions on Management Functions of Integrated Management Card In this chapter how to use the onboard management card is introduced e Chapter Eight Installation Introduction In this chapter how to install the server into the cabinet through rails
35. e rail and the lock tongue in the middle of the lock catch will fix the lock catch on the angle rail shown in figure 8 2 3 Match the screw holes on the front frame of guide rail with the corresponding Chapter One Safety Information o fixing holes on the angle rail of cabinet and then use 2 frame fixing screws to fix on the up and down screw holes of the front frame shown in figure8 3 4 Then based on the depth of the cabinet properly adjust the back frame match the screw holes on the back frame of guide rail to the corresponding fixing holes on the angle rail of cabinet and then use 2 frame fixing screws to fix 5 Repeat the above steps install the other guide rail to the cabinet Notices According to the signs L R on the front inner side of the inner rail install the guide rails to the left and right sides of the cabinet respectively Make sure the front and back guide rail at the same level at the same time the left and right guide rail must be at the same level too shown in figure 8 4 Figure 8 2 Chapter One Safety Information ES Figure8 4 8 4 Install the Server to Cabinet 1 Completely pull out the middle rail and inner rail in the guide rails of the two sides until they can t be pulled any more 3 hole slots can be seen on the pulled out inner rail shown in figure 8 5 2 Every side of the server has 3 screws corresponding to the hole slots on the Chapter One Safety Information o in
36. ed to set video recording time and storage Settings directory and video recording could be carried out only after setting storage directory Chapter Seven Use Instructions on Management Functions of Integrated Management Card O H Remote desktop Power menu Video Keyboar Mouse Options Media Keyboard Layo Video Recor MELELE Active User Help Zoom Size 110 ag sz Reset Server Immediate Shutdown Orderly Shutdown Power On Server Power Cycle Server Menu Functions Reset Server Select this option to restart server Immediate Shutdown Select this option to shut down server immediately Orderly Shutdown Select this option to shut down server according to sequence Power On Server Select this option to start server Power Cycle Server Select this option to restart after server shutdown I Remote Desktop Active User Click Active User menu to view current remote login username and IP address J Remote Desktop Help Menu Click menu dropdown menus About JViewer will display select this option version of this relocated browser will display Server Power Control Menu Select Server Power Control menu to enter the interface as shown in the following admintAdministratc C Refresh Print Logout Dashboard FRU Information Server Health Configuration Remote Control Maintenance HELP Power Control and Status J The current server power
37. eeees 5 1 Inspur Drive U Disk Use Instructions ceceeseeeceneeeecececeseeeeceneeeneeees 5 2 Install Windows Server 2008 R2 Manually ccceescesssseeeseeeteeeeteeeeees 5 3 Install Red Hat Enterprise Linux 6 3 Manually 0 cc ceceeceeseeseeereeeeeeees Chapter Six Common Problems and Trouble shooting cceceereeees 6 1 ReStartin Server s incase tiissesvccsseeseeuveed lecwouw ald waveisdinsvesseele issue deed tgedestendies 6 2 Problems When Starting the Machine ccccccececeeeseeeeteeeeteeeteeeeteeeeaes 6 3 Machine Alarm rnn e ERA EEEE 6A Additonal NOS iwicaszicsestecasieanscatcastesvecasseaianeeagiaavacdtansaaneagieaetesieayraanteayy Chapter Seven Use Instructions on Management Functions of Integrated Management Card cccccecceeseeeseeeeeeceeeneeeneeees 1 Management Chip BMC IP ananira e vente dteesas Ta Romol Log ionansnnn an S Chapter Eight Server Installation Guide 0 0 cccccccceccccesseeeseeeeeeeeneeneneeees 8 1 Cabinet Preparatore nte n E E E 8 2 Components Needed in Server Installation 2 0 0 ceceeeeseeeseeeeeeeeeeeeeneeees 8 3 Install Guide Rail into Cabinet eee ceceeeseeseeeseeeseeeeeeeeeeeeeeeeeeaeeneeenes 8 4 Install the Server to Cabinet c0 ccsccesccsscstscsscsnsossenscstesnnessnestesnaesacsnae Chapter One Safety Information y varine the following warnings show that there are potential dangers that may cause property loss personal injur
38. etup top panel towards back of the machine 4 Remove case top panel Open Case Top Panel 3 2 2 Mainboard Jumper Function Introduction Positions of mainboard jumpers are as shown in the following figure CLR_CMOS BEE Mainboard Jumper Position Figure QD Chapter Three System Setup _ Jumper Name Function Description Jumper Function CLR_CMOS Jumper CMOS Jumper Short circuit pin 1 2 normal status default Short circuit pin 2 3 clear CMOS Note 1 It is required to shut down the system when clearing CMOS and cut off power 2 After jumper operation completes please install top panel of the case Chapter Four SATA RAID Setting This chapter mainly introduces configuration of mainboard integrated Intel SATA Controller HostRAID and its usage If the server you ve purchased does not use mainboard integrated SATA HostRAID this option could be neglected Use mainboard to integrate SATA HostRAID it is required to enter BIOS and set Advanced gt SATA Configuration gt SATA Mode to RAID Mode 4 1 How to Enter SATA HostRAID Configuration Interface 1 During system startup screen will prompt Press lt CTRL I gt to enter Configuration Utility 2 Press Ctrl I buttons to enter SATA HostRAID configuration interface 4 2 Application of C
39. for net drive display drive and system service pack you could still refer to instructions in this chapter for installation This installation instructs manual installation of operation system taking 2108 SAS RAID configuration as an example if your server is configured with other external RAID cards please refer to user manual in CD to add hard disk controller drive as for net drive display drive and system service pack you could still refer to instructions in this chapter for installation For whether the selected operation system edition is supported by the machine purchased confirmation is suggested to be carried out in advance 5 1 Inspur Drive U Disk Use Instructions Inspur drive U disk could be recognized into analog floppy disk 3 5 floppy disk A and normal U disk partition UDISK PRO When install some operation systems manually you could use Inspur drive U disk to load hard disk controller drive which is currently supported by operation systems such as Windows XP and above Red Hat Linux 4 5 and above Suse Linux 9 0 SP2 and above Chapter Six Common Problems and Trouble shooting Warning During operation system installation by using Inspur drive Inspur drive U disk may be detected in disk partition interface at this time you need to distinguish U disk and hard disk do not delete or format U disk During operation system installation if you need to boot system from hard disk after reboot it is required to ente
40. formation Server Health Configuration Remote Control Maintenance This page gives detailed information for the various FRU devices present in this system Basic Information FRU Device ID o FRU Device Name BMC_FRU Server Information Chassis Type Rack Mount Chassis Product Name NF5270M3 d Product Manufacturer Name Inspur Product Part Number 00001 Product Version 00001 Product Serial Number 00001 Product Asset Tag Inspur0001 Board Manufacturer Inspur Manufacture Date Time Thu Dec 27 13 37 00 2012 3 Server Health Menu This function menu could view data information related to server health including three menus which are namely Sensor Readings Event Log and System and Audit Log Sensor Readings Menu It will display all sensor values sensor data mainly Chapter Seven Use Instructions on Management Functions of Integrated Management Card Se includes temperature voltage value and fan speed which could be refreshed or displayed according to types Event Log Menu It will display sensor events BIOS events system management software events OEM events and remote console software event logs which could be displayed according to classification or in a unified way Users could view logs or clear logs at anytime 3 System and Audit Log Menu It will display system logs and audit logs System logs need to be displayed according to classification 4 Configuration Menu Deshboerd FRU Intormation Server Health Conf
41. he computer is connected to a USB floppy disk make sure when Inspur drive U disk is connected to your computer part of analog floppy disk under Windows system shall be recognized into A so as to guarantee normal making of subsequent driver 2 Put driver CD driver CD includes Inspur system driver CD and RAID card driver CD into CD driver driver make program will run automatically If CD automatic running is disabled by the system please enter CD directory run dolphin bat in CD Inspur driver CD or setup exe RAID card driver CD under CD directory 3 Steps to make a driver using Inspur system driver CD 1 After running dolphin bat system enters Welcome to Inspur driver CD interface e Welcome to use Inspur driver co we a There re two methods for entering driver make main interface as shown in the following e Enter navigation code in textbox under Please input navigation NO See driver CD cover click lt OK gt button login main interface of driver make Click lt Exit gt button to exit e Select local server type in dropdown list under Please select the machine type Detailed machine type see host nameplate label Chapter Six Common Problems and Trouble shooting 2 After login via entering navigation code or selecting machine type enter main interface for driver make you could make a driver directly on this interface as shown in the following figure Common Tools Introdu
42. iguration Remote Control Maintenance Active Active Directory Settings ons Event Log iSe The Active Directory is ouirordy disabled To enabte Active RESAH a Etiam setings Click on Advanced Settings bution lete or modify a role group select the name in the list and INCoAMigUTeS siot and press Add Rote Group The kst below shows the current bst of configured Role Crd press Oelete Rote Group or Modify Role Group To add an Number of configures Rove groups 0 System and Auda Log Users Vitual Media Configuration menu is as shown in the above figure the following is brief introduction on commonly used menus Mouse Mode Menu Set mouse mode Set Mode to Absolute Recommended when server OS is Windows and Redhat Linux Set mouse mode to absolute while absolute mouse could shift freely between remote picture and local picture Set Mode to Relative Recommended when server OS is Linux without Redhat Set mouse mode to relative while relative mouse should select shortcuts of Alt H M to shift between remote picture and local picture Set Mode to Other Mode Recommended for SLES 11 OS Installation Set mouse mode Others which is suggested while installing SLES 11 operation system Network Menu Carry out configuration on network please change IP address or select DHCP according to needs NTP Menu Set date and time which could synchronize with time server or set time If remo
43. ion This will preserve all the configuration settings during the firmware update irrespective of the individual items marked as preserve overwrite in the table below All configuration items below will be preserved by default during a restore factory default operation Click Enter Preserve Configuration to modify the Preserve status settings 3 Preserve Configuration item gt Preserve Status 1 SDR Overwrite 2 FRU Overwrite 3 SEL Overwrite 4 IPMI Overwrite This function menu could realize BMC Firmware remote update and restart IPMI management card Firmware Update Menu This menu could carry out remote update of IPMI management card Firmware it is not suggested to carry out update by yourself if necessary update files should be authorized by us in advance Preserve Configuration This menu could be used to preserve option values in dropdown menu before loading factory default values Selected option values will not change while loading factory default values Restore Factory Defaults This menu is used to load factory default values of IPMI management card System Administrator This menu is used to modify rights and password of system administrator Chapter One Safety Information o Chapter Eight Server Installation Guide e The Guide will help you to understand how to install Inspur 1U server in Inspur server cabinet or compatible standard industrial cabinet e After in
44. ion failure or abnormal situation please contact Inspur and get technical support 3 Pay attention to the position of the system cables and power cables wire them in places not to be stepped on or knocked down and ensure not to place other objectives on the cables 4 Before dismounting the cover of host or contacting the internal components you shall cool down the equipment first to avoid damaging the main board please power off the system and wait for 5 seconds and then dismount the components from the main board or disconnect the connection of peripheral equipment of the system 5 If there are modulator demodulator telecommunication or local area network options in the equipment please pay attention to the following matters In case of thunder and lightning weather please do not connect or use the modulator demodulator Otherwise it may be subject to lightning strike ED Chapter One Safety Information Never connect or use modulator demodulator in moist environment Never insert the modulator demodulator or telephone cables to the socket of network interface controller NIC Before unpacking the product package contacting or installing internal components or contacting un insulated cables or jacks of the modulator demodulator please disconnect the modulator demodulator cables 6 In order to prevent the electrostatic discharge from damaging the electronic components in the equipment please pay attention to the fol
45. ion value of the menu to the next option value This button only displays values related to selected options rather than all option values F1 Function Button Help hotkey displays related instructions on current menu F2 Function Button Restore previous default setup F9 Function Button Restore system default optimal performance setup F10 Function Button Save CMOS setting and exit Enter Function Button Execute current commands or enter sub menu Chapter Three System Setup o D I Main Menu Enter BIOS setup main menu displays first user could view BIOS version and memory volume in this menu and could set system time and date etc When configuring system date and time use arrow buttons to select options press Enter to select subfield and use button and button to set field value e BIOS Information Displays system BIOS version BIOS modification time e Memory Information Displays system memory volume e System Date Sets system date the format is Week Day Month Year e System Time Sets system time adopting 24 hour system and the format is Hour Minute Second II Advanced Menu This menu is mainly used to set enhanced features if set improperly it may arouse abnormal system working it is suggested that you should use factory settings Main and common sub menus or options are introduced in the following e CPU Configuration Socket 0 1 CPU Information Displays det
46. ke the driver toa U disk 5 3 2 Installation Steps 1 To load hard disk controller driver connect an Inspur drive U disk or a normal U disk power on the system insert installation CD into CD driver here an installation DVD is used as an example enter BIOS to configure and enable the server to boot from CD driver 2 System enters Welcome to Red Hat Enterprise Linux 6 3 interface options are as shown in the following Install or upgrade an existing system Install system with basic video driver Rescue installed system Boot from local driver Memory test You could use up and down arrows to select here it is the first installation by default select Install or upgrade an existing system To add a new hard disk controller driver after selecting Install or upgrade an existing system press Tab enter linux dd after vmlinuz initrd initrd img and press Enter to continue installation as shown in the following figure Welcome to Red Hat Enterprise Linux 6 2 Install or upgrade an existing system Install system with basic video driver Rescue installed system Boot from local drive Memory test gt umlinuz initrd initrd img linux dd_ RED HAT ENTERPRISE LINUX 6 Copyright 2003 2010 Red Hat Inc and others All rights reserved Chapter Six Common Problems and Trouble shooting Screen prompts Do you have a driver disk select Yes press Enter to continue System prompts Dri
47. lowing matters You shall conduct off the static electricity on the body before dismounting or contacting any electronic component in the equipment You can conduct off the static electricity on the body by contacting the metal earthing objects such as the unpainted metal surface on the chassis to prevent the static electricity on the body from conducting itself to the sensitive components For electrostatic sensitive components not ready to be installed for application please do not take them out from the antistatic package materials During the work please touch the earthing conductor or the unpainted metal surface on the cabinet regularly to conduct off the static electricity on the body that may damage the internal components 7 When dismounting the internal components with the approval of Inspur please pay attention to the following matters Switch off the system power supply and disconnect the cables including disconnecting any connection of the system When disconnecting the cables please grab the connector of cables and plug it out and never pull the cables Before dismounting the cover of cabinet or touching the internal components the products need to be cooled down Before dismounting and touching any electronic component in the equipment you shall conduct off the static electricity on the body by touching the metal earthing objectives During the dismounting process the operation shall not be too big so as to
48. must not alter any other parameters in the main board BIOS of this server at any time except for the parameters which we promote that you can alter 2 If there are any hardware problems when you use this server or you wish to upgrade the hardware please feed back the detail hardware configuration of your computer to our Customer Service Don t disassemble the server case or any hardware components in the case by yourself 3 In this server the MEMORY CPU CPU Fan and Fan are in given standard Please don t use them with the corresponding components of any other computers confusedly 4 When you have any software problems during the application of this server we hope that you firstly contact the corresponding software supplier and then he will contact us in favor of communication so as to solve your problem together especially the software problems about the database the installation and running of the network management software or other networking product 5 Pictures in printings are for reference only please refer to the machine purchased actually 6 Please firstly read the accompany Brief User Guide when you install this server Please contact our Customer Service Center if you have any questions about the application 7 We must call your attention that in the application process you should pay attention to do necessary backup of your file 8 This is a Grade A product and this product may induce radio jamming In this cas
49. n the right at Hold Right Alt Key the same time during operation Select this option which is equal to pressing Ctrl button on the left at Hold Left Ciri Key the same time during operation Select this option which is equal to pressing Alt button on the left at Hole Les ey the same time during operation Select this option Hold down and Press and Release will display indicating to press or release Windows button on the left Left Windows Key Select this option Hold down and Press and Release will display Right Windows Key indicating to press or release Windows button on the right Select this option which is equal to pressing Ctrl Alt Del buttons at Alt cae the same time during operation Context Menu Context Menu Select this option and users could add hot keys according to actual Hot Keys ees Chapter Seven Use Instructions on Management Functions of Integrated Management Card O Note When carrying out RAID configuration via remote console it is required to enter RAID configuration interface via the following three methods taking Ctrl H key combination as an example Check Hold Left Ctrl Key option in Keyboard menu on desktop and then click H button on keyboard Select LCTRL button on lower right corner of remote desktop and then click H button on keyboard Click ctrl h on soft keyboard via SoftKeyboard in Keyboard
50. ner rail shown in figure 8 6 3 Raise the server and carry it close to the cabinet and then let the screws on the end of the server side stuck into the hole slots on the end of the inner rail from the top down Slowly lower the server to let all the screws stuck into the hole slots of the inner rail and the screws on the most front hole slot can be locked by plastic bayonet lock which can be pulled forward shown in figure 8 7 and8 8 4 Keep the server horizontal and push it steadily into the cabinet If it is blocked during the pushing lift slightly the blue bayonet locks on the both sides of the inner rail at the same time and push it into the cabinet meanwhile 5 Use 2 frame fixing screws to fix the server to the angle rail of the cabinet shown in figure 8 10 hole slot AN ps hole slot A Figure 8 6 Chapter One Safety Information ES Figure 8 9 Chapter One Safety Information O Figure8 10 Chapter One Safety Information Ste Chapter One Safety Information O Chapter One Safety Information Ste Chapter One Safety Information O Chapter One Safety Information Ste Chapter One Safety Information O Chapter One Safety Information Ste Chapter One Safety Information O
51. ng system In the AHCI mode if you want to install the operating system on the first physical disk when installing the operating system you can insert the first disk and pull out other disks You can insert other disks after the installation is completed Or enter BIOS SATA Configuration SATA Port item and set SATA Port3 Port4 Port5 item to Disabled At this time the system will be installed to the first physical disk After the completion of operating system installation set SATA Port3 Port4 Port5 item to Enabled In the HostRAID mode please record the name of the RAID volume when you are doing the RAID setting When installing the operating system please distinguish the name of RAID volume so that the operating system can be installed in specified place 5 Explanation that the disk array capacity under SATA HostRAID mode is not the maximum capacity This product integrates SATA HostRAID During the creation of RAID volume the system will automatically analyze the size of the physical disk and will automatically adjust the size of the RAID volume to 97 of the minimum physical disk volume Because of the different suppliers physical disk capacity may vary 6 For more notices of our products please refer to the FAQ for server in the official website of Inspur http www inspur com support Channel_ Home support_sv asp Chapter Seven Use Instructions on Management Functions of Integrated Management Card This product in
52. nnected 2 Repeatedly press the power button to start the machine pay attention not to exerting too much force Chapter Six Install Operating System o 3 Disconnect the power cable from the system and open the chassis to check 4 Check the fastness of the cable connection and accessory plugging in the chassis 5 Remove other external components other than Inspur s 6 Pack the chassis connect the power cable correctly and start the machine 6 2 2 Monitor Has No Display The server can be powered on the host can start and run normally but the monitor doesn t work 1 Check the correctness and fastness of the signal cable and power cable connected to the monitor 2 Make sure to power on the display 3 Adjust the contrast and brightness of the monitor to confirm whether it can display or not 4 Shut down the system and disconnect the power cable to check whether there is curve in the pin at the connecting end of the monitor signal cable and the host 5 Find another monitor for test if possible 6 If the machine is installed with components other than Inspur ones please remove them first 7 With the permission of Inspur technical support personnel you may pull and plug RAM and clear CMOS for test 6 2 3 Installation System Can t Find Hard Disk 1 When installing the system directly booted with the system CD if it prompts that no hard disk can be found please check the normality of the disk state and power
53. ntact our customer service center for solution Notes When replacing or installing hardware device for the server you should disconnect the power cable from the server completely It is recommended to use the anti static wrist strap and to earth connect the other end to provide electrostatic protection in dismounting the server 6 1 Restarting Server When a failure occurs please try to restart the machine according to the following methods first Purpose How to operate Restart the software clear up system memory and restart the operatin poy y peranns lt Ctrl Alt Del gt system Cl t self check the POST again and restart th ti system memory self check the again and restart the operating p oset button sy Cold boot again switch off and restart the system power so that to clear up the system memory to self check the POST again to restart the operating Power button system and to power up all peripherals again 6 2 Problems When Starting the Machine Some problems often occur when the machine is started generally due to incorrect hardware installation and configuration You may find and solve the problems by the following methods 6 2 1 System Can Not Be Powered on After pressing the power button the power light is not on and the system stays in non electric state Please try the following steps 1 Check whether your power socket can supply power normally and the power cable is correctly co
54. nto fire or water Please do not try to open or repair the batteries and be sure to reasonably deal with the flat batteries and do not put the flat batteries the circuit boards that may include the batteries and other components with other wastes For relevant battery recovery please contact the local waste recovery and treatment mechanism If what you bought is the chassis besides carefully read the installation description attached with the cabinet products and get known about the special warning notices and installation process you must abide by the following preventive measures to guarantee the cabinet to be stable and safe Warning 10 Before installing equipment in the chassis please install front and side supporting feet on the independent chassis for cabinet connecting with other chassis it shall install the front supporting foot first If you fail to install correspondingly the supporting foot before installing equipment in the chassis it may cause the cabinet to turn over in some cases and thus may cause personal injury Therefore it is necessary to install supporting feet before installing equipment in the chassis After installing the equipment and other components in the chassis it can only pull out one component from the cabinet through its sliding component at one time Pulling out several components at the same time may lead the cabinet to turn over and cause serious personal injury Warning 11 Please do not move the chassis
55. o that setting parameters improperly may arose the conflict among the hardware resource or fall down the system run performance Hence understanding the BIOS setup is significant to the configuration of your server If no especial requirement you are suggested to use the default value and not alter the parameters optionally A Notes 1 Before the server BIOS setup is altered please record the corresponding original setup Hence when there are operating problems in the system due to the option altered the setup can revert 2 Ordinarily the factory default system value is the optimized setup Don t try to alter the parameters before you understand their denotations 3 The common setup is introduced in detail in this paper The less referred options in the application procedure are simply explained or not 4 The content of the BIOS is diverse based on the different configurations of the products hence the detailed introduction is elided 3 1 1 How to Enter the BIOS Setup Power on the server system starts to guide when the following prompts on the screen Press lt DEL gt to SETUP or lt TAB gt to POST press DEL wait a few seconds to enter system BIOS setup If user could not enter setup procedure via the above operation please press Ctrl Alt Del to restart system repeat the above operation if system prompts to lt gt Chapter Three System Setup press DEL again complete the action as soon as
56. ogon and close the Chapter Six Common Problems and Trouble shooting window 16 Install Chipset patch 1 Insert Inspur system driver CD into CD driver click install on autoplay interface popped up after CD running or run the blue dolphin icon under running programs enter Welcome to use Inspur driver CD windows input navigation code see driver CD cover or select machine type see host nameplate label for detailed machine type click lt OK gt to enter installation interface automatically 2 Select in Select OS column Windows 2008 3 Select in Select Hardware column Chipset patch 4 Click lt Next gt to install 5 Enter Welcome to the Setup Program interface click lt Next gt to continue 6 Enter License Agreement interface select lt Yes gt to continue 7 Enter Readme File Information interface click to continue 8 Installation starts click lt Next gt according prompt 9 Complete installation click lt Finish gt according to prompt take out drive CD and reboot system 17 Install network card driver 1 Insert Inspur system driver CD into driver click install on autoplay interface popped up after CD running or click blue dolphin icon under running program enter Welcome to use Inspur driver CD windows enter navigation code see driver CD cover or select machine type see host nameplate label for detailed machine type click lt OK gt to enter installation
57. ontrol Buttons Button Description Used to move cursor in different menus or change menu option values To select the next menu setting option To select menu To exit menu or return to the previous menu from submenu 4 3 SATA HostRAID Configuration After entering SATA HostRAID configuration interface menu list information of hard disk connected to SATA controller hard disk ID hard disk type hard disk volume and whether hard disk is volume member or not etc existed RAID volume information including volume ID name RAID level capacity status whether it could guide information or not As shown in the following figure Chapter Four SATA RAID Setting Create RAID Volume Reset D o Non RAID Delete RAID Volume 4 There re 4 executable menus in this SATA configuration interface as follows Create RAID Volume Create RAID volume Delete RAID Volume Delete existed RAID volume Reset Disks to Non RAID Reset hard disks in RAID volume and restore to non RAID status Exit Exit SATA HostRAID configuration interface I Create RAID Volume Menu After entering SATA HostRAID configuration interface use Up and Down arrow buttons to select this menu and press Enter to enter RAID volume menu System displays the following menu options Name Please enter a volume name not exceeding 16 characters without special characters RAID Level Please select RAID volume level if there
58. ormal status System Abnormal Indicator Chapter Two Product Introduction _ It provides alarming function for system abnormal status i e abnormal status such as over high system temperature etc amber Indicator off when system operates normally while AC power on BMC initiating indicator on is a normal status ID Indicator After the server is connected to power supply press ID button indicator on blue to identify machine press again to turn off Network Card 1 Indicators Intel 1350 network card 1 indicators Flash Network is connected or is transmitting data green Off Network disconnected Network Card 2 Indicator Intel 1350 network card 2 indicator Flash Network is connected or is transmitting data green Off Network disconnected Power Status Indicator Lights on green when server starts to run lights off when server shuts down USB Interface Connects USB device Installation Positions of 1 8 Hard Disks Installation Positions of 1 4 Hard Disks 2 3 Back Panel View Installation positions of 2 5 inches 8HD type 1 8 hard disks Installation positions of 3 5 inches 4HD type 1 4 hard disks Name Back Panel View Function and Description Power Input Interface Connects power cable the above figure is an example for dual power configuration Serial Interface Connects serial interface device Integrates Intel 1350 network c
59. owser during usage please install according to suggestion A Remote desktop Video menu Keyboar Mouse Options Media Keyboard Layo Video Recon Power Active User Help Zoom Size 110 Pause Redirection Alt P Resume Redirection Alt Refresh Video AIL E Compression Mode DCT Quantization Table E Host Video Output O Full Screen Exit Chapter Seven Use Instructions on Management Functions of Integrated Management Card ES Menu Functions Pause Redirection Pause Remote Desktop Display Resume Redirection Resume Remote Desktop Display Refresh Video Refresh Remote Desktop Display Compression Mode Compression Mode Setting Det Quantization Table Remote Desktop Display Quality Setting Host Video Output Full Screen Display of Remote Desktop Full Screen Exit Remote Desktop Exit Pause Remote Desktop Display B Remote desktop Keyboard menu Video Keyboari Mouse Options Media Keyboard Layo Video Recor Power Active User Help Zoom Size 110 O Hold Right Ctri Key Ge B e f ISE so ES ie E Hold Right Alt Key Hold Left Ctrl Key Hold Left Alt Key Left Windows Key gt Right Windows Key gt Ctri Alt Del Context Menu Hot Keys Menu Functions Select this option which is equal to pressing Ctrl button on the right Hold Right Ctrl Key at the same time during operation Select this option which is equal to pressing Alt button o
60. r server BIOS to set so as to guarantee hard disk boot sequence is before U disk boot sequence and system could boot from hard disk otherwise system will not be able to boot from hard disk The following is a brief introduction on the making of mainboard integrated hard disk controller drive while installing operation system via using Inspur drive U disk For driver make of external RAID card or SAS card please refer to related content in external card drive CD Driver Make 1 Prepare a computer configured with Windows system connect Inspur drive U disk to USB port of the computer as shown in the following figure Inspur drive U disk will be recognized into two parts of analog floppy disk 3 2 Floppy A and U disk normal partition Removable Disk E among which drive E in Removable Disk E will be different according to actual partition in your computer 5 x File Edit View Favorites Tools Help amp pak O F A search gt Folders gt X 19 Fle E Hard Disk Drives Local Disk C Local Disk 19 5 GB 15 7 GB Devices with Removable Storage B5 Floppy AJ 3 4 Inch Floppy Disk Ll 420080818_1446 CD Drive 2 30 GB O bytes SP Removable Disk E Removable Disk kr Note Before connect Inspur drive U disk to the computer if your computer Chapter Six Common Problems and Trouble shooting is configured with a standard floppy disk please enter BIOS to close this floppy disk if t
61. r supply or 650W and above 1 1 redundancy power supply Power Input Please refer to specification in nameplate label of the host Physical Specification External Dimension of Package W Width 669mm H Height 287mm D Depth 909mm Machine Size W Width 430 6mm H Height 44 4mm D Depth 680mm Weight Full configuration 8hard disks Whole machine weight 19 2Kg Gross weight 35 Kg Gross weight includes Main machine package box guide rail accessory box Chapter Two Product Introduction __ Environment Parameters Working Environment Temperature We nee Storage amp Transportation Temperature 0 CIG Working Humidity 35 80 relative humidity Storage amp Transportation OF _ 0 K i idi Humidity 20 93 40 C relative humidity 2 2 Front Panel View This server has two configurations of 2 5 inches 8HD type 3 5 inches 4HD type pictures in the following are for reference only please refer to the machine purchased actually 0 2 5 Inches 8HD Type Front Panel View 3 5 Inches 4HD Type Front Panel View Name Description Power Button Server On Off button ID Button System ID identification button It provides alarming function for fan failure When system operates normally indicator not on Fan Failure Indicator When system fan fails indicator on amber When power off or AC power on BMC initiating indicator on is a n
62. s of Enabled and Disabled default settings If set to Enabled settings on cleaning methods for system event logs etc could also be carried out Erase SEL For settings on system event log erasing methods there re the following three options No default No log erasing Yes On next reset Erase logs during the next reboot a Chapter Three System Setup Yes On every reset Erase logs during each reboot When SEL is Full For erasing methods when system event logs reach the maximum recording number there re the following two options Do Nothing default Do nothing Erase Immediately Erase logs immediately BMC network configuration This menu is used for information configuration on BMC network interface Lan channel 1 Related options under this menu could be used to set information such as IP address acquiring methods IP address subnet mask and router IP address etc when mainboard integrated Intel 1350 network card 1 is used as reuse management interface When set to Static it is required to set information such as IP address subnet mask and router IP address etc manually when set to Dynamic default it is not required to set the above options Lan channel 2 Related options under this menu could be used set IP address acquiring methods for special IPMI management interface When set to Static it is required to set information such as IP address subnet mask and
63. stalling the server in the cabinet according to the Guide please refer to other accompany material to acquire more application directions e Please uncover the film on the cover plate of the server and then power up to use it e Pictures in the Guide just for reference please give priority to real products 8 1 Cabinet Preparation Angle rail adjustment in order to guarantee the 1U server can be installed in the cabinet normally the clearance between the front and rear part of the angle rail should be adjusted to be at least larger than 740mm Leveling cabinet the cabinet must be installed in a stable place Adjust the four support feet at the bottom of the adjustment cabinet to make the cabinet stable on the ground Meanwhile dismount the cabinet door for convenience of guide rail installation Cabinet grounding to avoid electric shock a grounding device must be installed in the cabinet If the server power line is installed in the power socket which constitutes a portion of the cabinet grounding should be properly provided for the cabinet If the server power line is inserted into the power socket in the wall the grounding device in the power socket just provides grounding for the server and then proper grounding protection for cabinet and other internal devices should be provided We recommend you to use the cabinet specially designed by Inspur for the server If so the internal of the cabinet should be already grounded Please don
64. status is shown below To perform a power control operation select one ofthe options below and press Perform Action Hostis currently on Reset Server Power Off Server Immediate i Power Off Server Orderly Shutdown Power On Server Power Cycle Server Server Power Control Menu To display current power status of server providing five options which are namely server restart instant shutdown sequential shutdown startup restart after system shutdown select one option to be executed and click Perform Action to perform Chapter Seven Use Instructions on Management Functions of Integrated Management Card 6 Maintenance Menu admin a Refresh 9 Print FRU Information Server Health Configuration Remote Control Maintenance Dashboard Firmware Update Firmware Update Preserve Configuration Upgrade firmware of the device Press Enter Update Mode to put the device in update mode Restore Factory Defaults n System Administrator The protocol information to be used for firmware image transfer during this update is as follows Ti Configuration under Firmware Update menu Protocol Type HTTP HTTPS WARNING Please note that after entering update mode widgets other web pages and services will not work All open widgets will be closed automatically If upgrade process is cancelled in the middle of the wizard the device will reset Preserve all Configurat
65. t off the alarm There may be array abnormality when the hard disk back plane alarms there is always abnormal status light of the hard disk on the front panel which can be used to help analysis 3 After having collected the basic information please feedback the detailed alarm information to Inspur technical support personnel in a timely manner We will make further analysis and judgment and help you solve the problem as soon as possible 6 4 Additional Notes 1 In order to guarantee the reliability of the system it is suggested that you use the component of the relevant Model tested and authenticated by us when expanding and equipping components 2 Please guarantee the fine electricity utilization environment of the server normal voltage input and earth connecting condition and temperature and humidity and Chapter Six Install Operating System SES so on within the normal range 3 For special needs when transferring the server pay attention to avoiding the vibration and carry out in power off condition 4 The out of order problem introduction in Windows Server 2008 system The phenomenon that the system disk RAID volume is inconsistent with the physical disk RAID volume will appear when this product is in the AHCI mode with more than one disks or HostRAID mode with more than one RAID volume of SATA configuration when installing Windows Server 2008 operating system This phenomenon is the Bug of Windows Server 2008 operati
66. te management requires selecting time server synchronization please Chapter Seven Use Instructions on Management Functions of Integrated Management Card o enter address of time synchronization server Remote Session Menu Set loading methods for virtual media SMTP Menu Set IP address of SMTP server as well as user name and user password User Menu Carry out configuration on users could add delete and modify users etc Set user name should begin with an English letter and should be within the range of 4 32 characters while password length should be at least 8 characters Virtual Media Devices Menu Set the number supported by various virtual devices the maximum number supported by various virtual devices is 2 and whether to support SD media or not 5 Remote Control Menu admin Adm 7 C Refresh Print Cogout Dashboard FRU Information Server Health Configuration Remote Control HELP z s Console Redirection Console Redirection Server Power Control Press the button to launch the redirection console and manage the server remotely Java Console This function menu could execute various remote operations with respect to server such as running remote console system on off as well as other control operations Console Redirection Menu Login to console After selecting this menu click Java Console button system will login to remote desktop If it is suggested to install Jviewer br
67. tegrated SATA controller mainboard led four SATA II interfaces two SATA III interfaces During standard CD driver configuration 1 SATA interface is used to connect SATA CD driver Management Card Management Card Chip Management Card Interface Integrated Aspeed 2300 chip supports IPM12 0 IK VM It can use IPMI special interface for management or reuse the 1st network card of Intel 1350 Network Card Network Card Controller Intel 1350 network controller leads two network interfaces PCI Extension Slot PCI Bus Type PCI Express bus supports horizontal plug half height extension card PCI Slot 3 PCIE 3 0 x8 slots supports 3 when dual CPUs supports 2 when single CPU unable to use PCIE_5 slot for case structure limitation 3 PCIE 3 0 x16 slots supports 3 when dual CPUs supports 1 when single CPU Hard Disk Hard Drive Type 3 5 inches SAS hard disk and SATA hard disk 2 5 inches AS hard disk SATA hard disk and SSD hard disk different types support different hard disk types please refer to actual configuration Quy 2 5 inches 8HD type Supports maximum8 2 5 inches hard disks 3 5inches 4HD type Supports maximum 4 3 5 inches hard disks External Storage Driver Inspur U Drive Disk It can select Inspur U Drive Disk and can load driver program of hard drive controller while installing operation system manually Power Supply Specification 700W single powe
68. tegrates IPMI management card and could remote login server via management card use of integrated management functions of management card is described in brief in the following 7 1 Management Chip BMC IP IP address of integrated IPMI management card could be viewed or set in Server Megmt BMC network configuration Lan channel1 2 Station IP address menu in BIOS A Notes Lan channel Indicates reuse management interface mainboard integrated Intel 1350 network card 1 Lan channel 2 Indicates exclusive interface for IPMI management Please set or view IP address according to actual use situation of net card If you ve reset IP address of IPMI management card after saving it is required to restart or power off the server plug off the cable for normal use 7 2 Remote Login 7 2 1 System Requirements of Remote Client System requirements on client connecting to server management chip GUI interface via a web browser are shown in the following table Requirements Remote Web Console Client Operation System To support OS of Microsoft Internet Explorer browsers To install Java SE Runtime Environment 6 Update 12 or higher Browser Plug in version TCP IP Network Protocol Stack To support TCP IP network protocol stack Download address of browser plug in Java SE Runtime Environment http www java com en download Chapter Seven Use Instructions on Management Functions of
69. tem fan speed and voltage etc View System Information Enter this menu to view system detailed information including system manufacturer product name BMC version etc V Boot Menu Boot menu is mainly used to set system startup and priority of system guiding device Quiet Boot This option could be used to set display status during system startup When set to Disabled it will display self check process and detection information when set to Enabled default it will display manufacturer LOGO Boot Option 1 2 Select a certain guiding sequence option press enter to pop up optional guiding device table select a certain device via arrow button and then press enter to complete setting this guiding sequence option Network Device BBS Priorities Press Enter to enter sub option of this menu user could set guiding sequence of all network cards supporting PXE function Hard Drive BBS Priorities Press Enter to enter sub option of this menu user could set guiding sequence of all hard disks VI Security Menu Administrator Password Chapter Three System Setup This option is used to set system administrator password After setting administrator password enter BIOS Setup program it is required to enter administrator password otherwise some administrator rights will be restricted User Password This option is used to set user password After setting user password during system startup and entering BIOS Setup program it
70. tibility by Inspur group or replace with other keyboard and mouse for testing 6 2 6 System Blue Screen Halt or Restart For blue screen restart or halt of the machine in the utilization of the system you may refer to the following measures 1 If other external non Inspur components or some application program software are installed before the fault it is suggested removing it and going on to test your server 2 Use the latest antivirus software for antivirus test 3 It is suggested that you record the displayed information code for blue screen such as stop c000000218 stop 0x0000007b This kind of information reveals problems in the system It is suggested that you reinstall it For the installation process you can refer to the user manual 4 If all above operations failed to solve the problem it is suggested that you backup the file winnt minidump in disk C and call the service center for support from professional technical engineers who may ask you to provide minidump file for further analysis on the cause for blue screen and halt If there is no minidump folder in disk C please refer to the following steps right click on My Computer select lt Property gt lt advanced gt lt startup and recovery gt then select lt settings gt change lt write debugging information gt in the next page to small RAM dump and restart the machine The system will produce minidump file automatically in the next blue screen
71. ur installation involve Basic Storage Devices Installs or upgrades to typical type of storage devices If you re not sure which option is right for you This is probably it Specialized Storage Devices Installs or upgrades to enterprise devices such as Storage Area Networks SANs This option will allow you to add Foe Ischia Zech disks and to filter out devices the installer should ignore Here we select Basic Storage Devices and then select Next to continue Chapter Six Common Problems and Trouble shooting 8 System enters Please name this computer The hostname identifies the computer on a network Please input Hostname Here we could also select Configure Network on the bottom left to carry out network configuration add or delete network card and configure network IP address After network configuration completes select Next to continue 9 Installation enters Please select the nearest city in your time zone time zone selection interface select Asia shanghai and then click Next to continue 10 Installation enters Root Password Setting interface please set according to requirements the password shall be at least 6 digits and then click Next to continue The root account is used for administering the system Enter a password for the root user 11 Installation enters Which type of installation would you like installation type selection interface and installation options are as follows
72. ver Disk Source for we use a U disk here please select sda and then select LOK to continue If a floppy disk is used please select sdb 3 System prompts Driver Disk Source for multiple U disk partitions please select the partition containing the driver and then select OK to continue System prompts Select driver disk image select the driver image to be loaded and then select OK system starts driver loading After loading completes system prompts More Drivers Disk asking whether to load another driver here we select No to complete driver loading If you do not need to add any hard disk controller driver press Enter directly to continue 3 System prompts Disc Found to begin testing the media before installation press OK Choose Skip to skip the media test and start the installation Here select to skip media testing press Enter to continue 4 Enter RED HAT ENTERPRISE LINUX 6 interface select Next to continue 5 System enters What language would you like to use during the installation process interface select the language to be used during installation here we select English English and then select Next to continue 6 Enter Select the appropriate keyboard for the system interface and select keyboard type according to actual situation here we select US Englsh and then select Next to continue 7 Installation enters What type of devices will yo
73. wer2 Status NotAvailable IPV6 Address CPUILYR 38 C A PCE arc A Remote Control i lamh ps a g Chapter Seven Use Instructions on Management Functions of Integrated Management Card o On top of the interface the following function menus could be seen Dashboard FRU Information Server Health Configuration Remote Control and Maintenance User login name and user group to which login user belongs will display on top right of the interface context menus such as Refresh refresh page Print print page Logout logout Simplified Chinese language switch are also available 1 Dashboard Menu Users could see management chip Firmware version modify time as well as MAC address etc in this menu interface Click Edit button behind Network Information to enter network setting interface set IP address and gateway etc Window at the bottom of remote control displays remote console information Click Launch at the back of remote control to login to console if system prompts to install Jviewer browser during operation please install according to prompts 2 FRU Information Menu FRU information will display in this menu including Basic Information and Server Information ID number and name of FRU device will display in Basic Information Server machine type name and manufacturer etc will display in Server Information Detailed information is shown in the following figure admin Refresh Print Dashboard FRU In
74. wo Product Introduction 2 1 Server Technical Specification Processor Processor Type Intel 2 way Xeon E5 26XX series CPU Processor Qty 1 2 Processor Interface Socket 2011 Chip Group Chip Group Type South Bridge PCH A Memory Memory Type Single Inline Memory Module Qty DDR3 ECC Unbuffered Registered Memory Single CPU can support maximum 12 double CPUs can support maximum 20 Memory Volume When single 16G memory is used it can support maximum 320GB Maximum memory volume will increase with the increase in single memory volume T O Interface USB Interface 2 front USB interfaces 2 back USB interfaces 1 built in Type A USB interface Serial Interface Network Interface 1 back serial interface 2 optional RJ45 network interfaces 1 special interface for management Display Interface 1 back VGA interface ID Indicators and Buttons ID Indicators and Buttons 1 ID indicator blue at the front of the case 1 ID button 1 ID button including ID indicator blue at back of the case Display Controller Controller Type Mainboard integrated AST2300 display controller Display Memory Size 16MB display memory Hard Disk Controller SAS Controller Mainboard integrated 4 SAS interfaces various optional ROMs supports different RAID level SATA Controller Chapter Two Product Introduction _ South Bridge in
75. y boot Create swap partition Swap Select Swap in File System Type select the hard disk to install system in Allowable Drives window enter swap size in Size MB According to memory size if memory is under 512MB set according to twice of the memory if memory is over 512MB set swap partition to 2GB click OK to complete swap partition creation You could also create another partition according to needs after creation click Next to continue 14 System pops up a prompt Writing storage configuration to disk The partitioning options you have selected will now be written to disk Any data on deleted or reformatted partitions will be lost Select Write changes to disk to continue installation system starts to format hard disk partition 15 Installation enters Boot Loader setting interface please set according to needs and then click Next to continue 16 System prompts The default installation of Red Hat Enterprise Linux is a basic server install You can optionally select s different set of software now Please select the type to be installed as well as software package to be customized according to actual needs Here we select Customize now option click to Next continue 17 Installation enters software package selection interface please select according to actual needs confirm the software package to be installed and click Next to continue Here we select development tool softw
76. y or death Warning 1 The power supply equipment in the system may generate high voltage and dangerous electrical energy and thus cause personal injury Please do not dismount the cover of the host or to dismount and replace any component in the system by yourself unless otherwise informed by Inspur only maintenance technicians trained by Inspur have the right to disassemble the cover of the host dismount and replace the internal components Warning 2 Please connect the equipment to appropriate power supply and the power should be supplied by external power supply which is indicated on the rated input label To prevent your equipment from damages caused by momentary spike or plunge of the voltage please use relevant voltage stabilizing equipment or uninterruptible power supply equipment Warning 3 If extended cables are needed please use the three core cables matched with correct earthed plug and check the ratings of the extended cables to make sure that the sum of rated current of all products inserted into the extended cables do not exceed 80 of the limits of the rated currents of the extended cables Warning 4 Please be sure to use the supplied power supply component such as power lines power socket if supplied with the equipment etc For the safety of equipment and the user do not replace randomly power cables or plugs Warning 5 To prevent electric shock dangers caused by leakage in the system please make sure that the power ca

Download Pdf Manuals

image

Related Search

Related Contents

GE Profile CustomStyle PSI23NGR Side by Side Refrigerator  DÉBRAYAGE - Théâtre(s) Politique(s)  InstallatIon · Manual 4.0073 1/4  GeoMax Zipp10 Series - Geomax Calabria GPS e Stazioni Totali  Samsung 931C 用户手册  取扱説明書 - マックスレイ    Blanco 510-876 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file