Contents
1. SSI Solid State Interlocking Tester Memory Module Tester UV Ultraviolet PS PSL RD 309 MAN 011 Park Signalling Limited 2009 Page 3 of 7 Issue 5 Registered number 03895736 2 EQUIPMENT DESCRIPTION 2 1 Supplied Items The Tester consists of test control software an interface unit a mains power supply an interface cable and a serial communications lead e The software is supplied on a CD and installation on the host PC is described in Section 4 e The interface unit is a metal box 100 x 45 x 110 mm housing all of the electrical and electronic circuits of the Memory Module Tester Mounted on the box are a 40 way IDC connector for connection to the Memory Module under test a 9 way D type connector for connection to the PC a barrel type socket for connection to the power supply and an ON OFF switch e The power supply is a 230V 50Hz to 5V 1A DC switched mode power supply mounted in a UK plug housing e The interface cable is a ribbon cable with two IDC connectors Two interface cables are supplied One has a 40 way IDC at the interface unit end and a 50 way IDC at the Memory Module end and is used for Westinghouse MkII MPMs Specification WS1905B only The other cable has a 40 way IDC at the interface unit end and a 40 way IDC at the Memory Module end and is used for all other MPMs and for PPMs e The serial comms lead has a 9 way D type socket female at both ends to connect the interface unit to a serial comms port on the ho
2. Limited 2009 Page 6 of 7 Issue 5 Registered number 03895736 5 4 Running the test 1 Enter operator name on the PC 2 Enter your location on the PC 3 Enter the interlocking system s name on the PC 4 Select the Memory Module manufacturer on the PC 5 Select the Memory Module type on the PC 6 Enter the Memory Module s serial number on the PC 7 Enter the IC4 checksum on the PC 8 Enter the IC5 checksum on the PC 9 Press the Test module button on the PC 5 5 Results f Memory Module Tester version oos x Communications okay Date 22 08 2008 Operator Name Time 10 00 44 Operator Colin Car Location Park Signalling Stockport System Egham Junction Test Location Module type 551331 Serial No 77 0003 Park Signalling Stockport System Name Icz RAM okay IC4 Checksum Ox9Acs IcS Checksum 0x4584 le gham Junction gt Manufacturer f ALS C GEC C WSL 551331 E Module Serial Number 7 0003 IC4 Checksum IC5 Checksum 9AC8 458a lil Test module The PC will display the results for IC2 ICS e Ifthe checksums calculated by the Tester matches those entered by the user the IC s box will be green and the test has passed the checksums will be displayed If the checksums do not match then the result is a failure e Ifthe IC s box is red then the test has failed e Ifthe IC s box is grey then that component has not been tested because it is not present on the type o
3. User Manual for the PS PSL RD 309 MAN 011 SSI Memory Module Issue 5 Tester DG ingee i ose P info park signalling co uk Lim ited www park signalling co uk Summary This document describes how to use the ST 301 SSI Memory Module Tester Issues Issue number Date Issue 1 November 2007 First Issue Issue 2 April 2008 Updated to include changes to electrical connections amp interfaces Issue 3 April 2009 User interface changes requested by Network Rail Issue 4 April 2009 Amended in line with ISA comments Issue 5 December 2009 Detailed description of all supplied items added to Section 2 Author Checked Authorised C Exley M Duffy V G Patel Date Date Date PS PSL RD 309 MAN 011 Park Signalling Limited 2009 Page of 7 Issue 5 Registered number 03895736 User Manual for the SSI Memory gt Module Tester Park Signalling www park signalling co uk 2 aS e pa T e PS PSL RD 309 MAN 011 Park Signalling Limited 2009 Page 2 of 7 Issue 5 Registered number 03895736 1 INTRODUCTION 1 1 Purpose This document provides instructions on the use of Park Signalling s ST301 Memory Module Tester 1 2 Scope This document details how to use the Memory Module Tester Note that information on obtaining authorisation permission to work on a live signalling system is beyond this document s scope 1 3 Abbreviations EPROM Erasable Programmable Read Only Memory RAM Random Access Memory
4. f Memory Module being tested After testing the Memory Module can be disconnected from the Tester Turn the Tester off before disconnecting the Memory Module and connecting the next Memory Module to be tested PS PSL RD 309 MAN 011 Park Signalling Limited 2009 Page 7 of 7 Issue 5 Registered number 03895736
5. sion x vy and follow the on screen instructions PS PSL RD 309 MAN 011 Park Signalling Limited 2009 Page 5 of 7 Issue 5 Registered number 03895736 5 OPERATION 5 1 Condition check Check for any signs of damage particularly to the connector that mates with the Memory Module If the Tester appears to be damaged then do not use it Contact Park Signalling immediately and arrange for the Tester to be repaired 5 2 Compatibility check Ensure that the Memory Module to be tested is one of the following Testing a Memory Module not included in the list below may result in damage to the Memory Module and or to the Tester 5 2 1 Alstom Memory Modules e SS1311 e SS1321 e S1331 5 2 2 GEC Memory Modules SS1312 SS1315 SS1316 SS1317 SS1325 5 2 3 Westinghouse Signalling Memory Modules E20816 1 E20816 3 E20816 5 E25000 1 5 3 Connections amp settings 1 Turn on the PC and start the Memory Module Tester software 2 When prompted select the COM port to which the serial data cable will be connected and the file location to save test results in 3 Connect the power supply to the Tester 4 Connect the Tester s serial data cable to the serial port of the PC running the Tester program 5 Connect the Tester s interface cable to the Memory Module being tested 6 Turn the Tester on Communications okay will be displayed on the screen to confirm connections PS PSL RD 309 MAN 011 Park Signalling
6. st PC 2 2 Storage and Handling The Tester should be stored in a dry environment with a temperature range of 0 35 C The Tester should not be carried by its flying leads When using the Tester be aware of the trip hazard presented by the leads As the Tester is electronic equipment please dispose of it responsibly when it is life expired PS PSL RD 309 MAN 011 Park Signalling Limited 2009 Page 4 of 7 Issue 5 Registered number 03895736 DESCRIPTION The Tester consists of test control software a memory module interface unit mains power supply and serial communications lead The software is designed to run on a PC running Windows 2000 or later SSI Memory Modules contain UV EPROMs and RAM The EPROMS contain the main program software and data specific to the railway scheme Some versions of the Memory Module use paged memory to access EPROM data The Tester is capable of diagnosing the status of the Memory Module under test and provides a clear indication of any failure found Test results may be saved to the PC s hard drive The Tester provides the following functions e Go No go test of the Memory Module e Identifies checksums of the EPROMs e Tests the RAM e Test the address mapping 4 SOFTWARE INSTALLATION Administrative rights will be needed in order to carry out the installation If the Tester software is not pre installed on the PC double click the MMT_x_yy msi file on the installation CD where Tester ver
Download Pdf Manuals
Related Search
Related Contents
VGN-Z Series/Windows Vista Upgrade Kit USER GUIDE for the HES92020, HES92021, HES92220 Info Speed Basic Specifications et manuel d`utilisation Guide d`autocontrôle pour la production et la vente de PROCOTEX LISO MATE Sony Xperia Z1 16GB White Jabra Speak™ 410 SISTEMA ÍNDIGO Venha conhecer a mais recente Samsung 730MW manual de utilizador Copyright © All rights reserved.