Home

NI CVS-1450 Series Compact Vision System Quick Start Guide

image

Contents

1. QUICK START GUIDE NI CVS 1450 Series Compact Vision System Vision Builder for Automated Inspection Connect the Hardware UN Caution Before installing NI CVS 1450 Series hardware refer to the safety information in the NI CVS 1450 Series User Manual Connect the Camera and Monitor to the NI CVS 1450 Device A Connect the VGA cable from the monitor to the VGA port on the NI CVS 1450 device B Plug the IEEE 1394 cable into one of the IEEE 1394 ports on the NI CVS 1450 device Plug the other end of the cable into the IEEE 1394 port of the camera C Plug in and power on the monitor Wire Power to the NI CVS 1450 Device This section explains how to connect the power supply part number 778794 01 to the NI CVS 1450 device For instructions on how to connect a separate main supply refer to the N CVS 1450 Series User Manual A Caution Do notconnect the NI CVS 1450 device to a power source other than 24 VDC 10 Refer to the NI CVS 1450 Series User Manual for information about power requirements To Outlet A E D Plug the 4 position connector from the power supply into the power receptacle on the NI CVS 1450 device E Plug the power cord into the power supply F Plug the power cord into an outlet Once connected the NI CVS 1450 device runs a startup program that acquires images and displays them on the monitor These images verify that the hardware is p
2. click Select Network Target Configure Inspection Inspect Product Help Vision Builder lt for Automated Inspection aan E f This Computer ni com vision C Select the NI CVS 1450 WSelectRemoteTaget S device you configured Refresh and click OK a a amo mm n S Properties D On the Vision Builder Al TET Welcome screen click Configure Inspection OK v m El Cancel Inspection Steps Acquire Images Acquire Image IEEE 1394 Setup Main Features Trigger Format 7 Features el Step Name Acquire Image IEEE 1394 1 a Acquire Image IEEE 1394 Acquires an 1394 image from the selected IEEE 1394 camera Simulate Acquisition Simulates the a acquisition of images by reading images From file mma Select Image Selects a new image to o inspect Foa0xa80 Y Mono 16 30 00fps E From the Acquire Images palette F Click the Snap E button to acquire a click Acquire Image IEEE 1394 single image or click the Grab button to acquire continuous images Once you have configured your acquisition click OK to add the step You can now add inspection steps as described in the NI Vision Builder for Automated Inspection Configuration Help A QUICK START GUIDE NI CVS 1450 Series Compact Vision System This document describes how to set up and acquire an image using t
3. the nest page to Ja Plug the other end of Q Tip To uniquely identify unconfigured NI CVS 1450 devices connect and configure want to store the project and click i one NI CVS 1450 device at a time Next proleet nane cA the cable into the IEEE Welcome to LabVIEW 8 0 Real Time Module ARE 1394 port of the camera R a mE Install LabVIEW 8 0 Real Time Module A i FSI View Readme C Inthe Network Settings window type a name for the NI CVS 1450 device in the Name field C Plug in and power on es nae Explore the CD and a description of the NI CVS 1450 device in the Comment field the monitor Exit lt Back Next gt Finish Cancel Help Note Device names are limited to 15 characters with no spaces or special characters The first and last letters must be alphanumeric devices Wire Power to the NI CVS 1450 Device This section explains how to connect the power supply part number 778794 01 C Select Add blank vi to target Create new LabVIEW Real Time project and click Next z to the NI CVS 1450 device For instructions on how to connect a separate main supply ni com labview osa base ae ee D Ifthe network is configured to issue IP addresses using DHCP select Obtain IP ad
4. 1450 device and select E LabVIEW Support Add File X v LabWindows CVI Support Project Explorer PartValidation oe S X v NIMAQ 3 5 1 Driver software for IEEE 1394 Firewire IIDC File Edit Yiew Project Operate Tools Window Help JoSee xoOx l sea Ae e S b Project PartValidation yproj S Q My Computer X Microsoft Visual C Support y A X Microsoft Visual Basic Support es l Navigate to Program Fi les aF Dependencies X Microsoft NET Language Support ee ew E NIMAQ for IEEE 1394 Hardware Support This feature will be installed on the local hard drive X v NI 8254R Documentation S v NI CVS 1450 Series Support Ej National Instruments LabVIEW 8 0 examples i Build Specifications o Part alidation 10 0 58 137 G Using a standard CAT 5 Ethernet cable part number 189174 connect from the 245 E nman vo _ _ _ AAEE eee cman eh IMAQ IMAQ1394 i a network port to the Ethernet port on the NI CVS 1450 device require 180 KB of disk space examples 116 andclick 3 Season H Using a standard CAT 5 Ethernet cable connect from the network port to the a a Add File Directory for NIMAG for IEEE 1394 Cameras 2 0 2 a A A Ethernet port on the development computer C Program Files National Instruments NI IMAQ for IEEE 1394 Browse J Click Grab Vir and click Select Note If you are not connect
5. Remote Target Configuration Wizard Xi Model NI 1450 Series Serial Number FFFFFFFF MAC Address 00 80 2F D9 2D B8 System Status Running Name Partvalidation Description Line3 on 1al OK Cancel Hep f J Remote Target Configuration Wizard Xi Step 2 of 3 Network Settings O Obtain IP Address from DHCP Server Edit IP Settings suggest Values Reset to Default IP Address J 192 168 10 12 Subnet Mask 255 255 255 0 Gateway Gis Din Ga DNS Server 0 0 0 0 C Enable Password Set Password 0 Luo cance Help Download Software to the NI CVS 1450 Device l Select the Update Target Software checkbox J Click OK to begin configuring the IP address and downloading software onto the NI CVS 1450 device This initial installation process takes several minutes Step 3 of 3 Software Remote Target Configuration Wizard x v LabVIEW Real Time v NI IMAQ for IEEE 1394 RT y NI FIMAQ I O v NI IMAQ Server v NI RIO RT v NI Serial RT v NI 1394 External Drive Support v NI VISA v NI VISA Server Software Status Complete V Update Target Software m w gt lt O Acquire an Image A Launch Vision Builder Al Ni Vision Builder Al Welcome Jog B Expand the Execution Tin Target pull down listbox and
6. dress D Select the Networked option for C i aro th es Pa Conon ee 4 5 a FieldPoint Compact RIO Compact Vision System ieee from DHCP server Otherwise set the IP address manually by selecting Edit the IP settings Browse targets and click Browse al ail UN Caution Do not connect the NI CVS 1450 device to a power source other than Suggest Values and OK er a er 24 VDC 10 Refer to the NI CVS 1450 Series User Manual for information about Install the NI Vision Development Module and NI IMAQ for IEEE 1394 Cameras power requirements E Click Apply When prompted click Yes to restart the NI CVS 1450 device This initial C Insert the NI Vision Development Module CD When the installation screen appears installation process takes several minutes PanVaidaton EREN click Install NI Vision Development Module and follow the setup instructions While the NI CVS 1450 device is restarting a red X appears next to the f N device name to indicate that the NI CVS 1450 device is disconnected NATIONAL Ach i i V OL fh The MAX status bar also indicates the connection status of the NI CVS 1450 device ee re zE o Install NI Vision 8 0 Development Module oti Renta p Download Software to the NI CVS 1450 Device E Select the Existing target or device Tad Targets and Devices Explore the CD option from Targets and Devices EE E eu Exit F Inthe MAX configuration tree expand the device folder by clicking the plus sign nex
7. elow Dy m The specified folder does not contain the corect volume C Inthe Features tree select NI IMAQ for IEEE 1394 Cameras and NI IMAQ for IEEE 1394 Hardware Support FINI Vision 8 0 Acquisition Software Joe E Features NATIONAL Select the features to install OINSTRUMENTS BX NIMAQ 3 5 1 nea n Driver software for IEEE 1394 FireWire IIDC a j v NIMAQ for IEEE 1394 Cameras 2 0 2 compliant cameras including cameras configured on E Documentation NI CVS 1450 Series compact vision systems B E v LabVIEW Support E X vj LabWindows CVI Support E X vj Microsoft Visual C Support W X v Microsoft Visual Basic Support B X vj Microsoft NET Language Support S gt NIMAQ for IEEE 1394 Hardware Support This feature will be installed on the local hard drive X v NI 8254R Documentation E NI CVS 1450 Series Support S 9 NIMAQ 1 0 1 1 NI Measurement amp Automation Explorer 4 0 This feature and its selected subcomponents will require 180 KB of disk space w ES Directory for NIMAQ for IEEE 1394 Cameras 2 0 2 00 C Program Files National Instruments NI IMAQ for IEEE 1394 Restore Defaults Disk Cost lt lt Back Next gt gt Cancel D Click Next E Follow the installer prompts to complete the installation Configure the NI CVS 1450 Device Obtain an IP Address A Launch Vision Builder Al B Expand the Execution Tar
8. ew LabVIEW Real Time project J NI IMAQ I O 1 1 2 Connect the NI CVS 1450 Device to the Development Computer J NI IMAQ Server 1 6 1 G Verify that the NI CVS 1450 device AR A If the required files may be found elsewhere please enter LIMA for IEEE 1394 RT 2 0 2 SIR Project Partvaldation proj acy Verify that the development computer is connected to the network and powered on that location below jonas sia AREN appears correctly in the LabVIEW Piae D i P a 5S Build Specifications ee D m eee on Real Time Project and click Finish Saaana mia J NI 4 Untitled vi The specified folder does not contain the correct volume I NI VISA Server 3 4 1 a Pcie Ss Network Variable Engine 1 0 0 Variable Client Support 1 0 0 w E HEEJ sl i fal E In the Features tree select NI IMAQ for IEEE 1394 Cameras and NI IMAQ for IEEE 1394 ks Back aor gt gt Cre open vis when fished Hardware Support F NI Vision 8 0 Acquisition Software 3 x J Click Next lt Back next gt Finish cancel Help Features Select the features to install JEiNsTRUMENTS f H In the Project Explorer window The NI CVS 1450 device will automatically restart This process takes several seconds right click the name of your os i Cameras 2 0 li includi nfigured z i S a i Cvs 40 Serca compen ven ase NI CVS
9. get pull down listbox and click Select Network Target C Inthe Select Remote Target window click 192 168 10 12 to highlight the row This IP address is assigned to all unconfigured NI CVS 1450 devices NI Vision Builder Al Welcome a Vision Builder for Automated Inspection Configure Inspection Inspect Product Peas Description _ Status Refresh 192 168 10 12 Running J Monitoring 10 0 58 158 Line 2 Running x Sorting 10 0 58 168 Line1 Rumning configure j Properties Add Target Help 3 OK inal J m EA Cancel Tip To uniquely identify unconfigured NI CVS 1450 devices connect and configure one NI CVS 1450 device at a time D Click Configure to launch the Remote Target Configuration Wizard E Inthe Identification window enter a name for the NI CVS 1450 device in the Name field and a description of the NI CVS 1450 device in the Description field i Note Device names are limited to 15 characters with no spaces or special characters The first and last letters must be alphanumeric F Click Next G Ifthe network is configured to issue IP addresses using DHCP select Obtain IP Address from DHCP Server Otherwise set the IP address manually by selecting Edit IP Settings Suggest Values and OK H Click Next Step 1 of 3 Identification
10. he NI CVS 1450 Series compact vision system with NI Vision Builder for Automated Inspection or the LabVIEW Real Time Module and the NI Vision Development Module Use these instructions to verify that hardware and software are properly installed to configure an IP address for the CVS 1450 device and to acquire an image Note These instructions are intended for basic installation and configuration Refer to the NI CVS 1450 Series User Manual and the application software documentation for detailed installation and configuration instructions Refer to the blue side of this document if you are using Vision Builder for Automated Inspection Refer to the yellow side of this document if you are using the LabVIEW Real Time Module with the NI Vision Development Module 373609B 01 Mar06 National Instruments NI ni com and LabVIEW are trademarks of National Instruments Corporation Refer to the Terms of Use section on ni com 1egal for more information about National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your CD orni com patents 2003 2006 National Instruments Corporation All rights reserved Wir NATIONAL p INSTRUMENTS QUICK START GUIDE NI CVS 1450 Series Compact Vision System 2 Install
11. ing through a network use a crossover cable Restore Detauts _ _Disk Cost lt c Back _J _Newt gt _ K Click the Run button to begin acquiring images part number 187375 to connect the NI CVS 1450 device to the development computer F G Click Next Follow the installer prompts to complete the installation Now that you are acquiring images in LabVIEW you can use the NI Vision Development Module and the installed NI CVS 1450 device drivers to process images and to control inputs and outputs
12. roperly connected Connect the NI CVS 1450 Device to the Development Computer Verify that the development computer is connected to the network and powered on G Using a standard CAT 5 Ethernet cable part number 189174 connect from the network port to the Ethernet port on the NI CVS 1450 device H Using a standard CAT 5 Ethernet cable connect from the network port to the Ethernet port on the development computer Note If you are not connecting through a network use a crossover cable part number 187375 to connect the NI CVS 1450 device to the development computer Install the Software Note You must install Vision Builder for Automated Inspection Vision Builder Al before installing the NI IMAQ for IEEE 1394 Cameras driver software Install Vision Builder Al and NI IMAQ for IEEE 1394 Cameras A Insert the Vision Builder Al CD When the installation splash screen appears click Install Vision Builder for Automated Inspection and follow the setup instructions JENS TRUME INSTRUMENTS Install Vision Builder for Automated Inspection 2 6 1 Read me first Explore the CD Exit Vision Builder for Automated Inspection ni com vision Copyrig onal Instruments All right Install NI IMAQ for IEEE 1394 Cameras B When prompted insert the NI Vision Acquisition Software CD Insert Source X NI Vision Acquisition Software If the required files may be found elsewhere please enter that location b
13. t to expand the Compact Vision System S ceca ace AEE L Ey KE 0 Ouret gt the device name branch select your device and a na E A Vi a click OK O New target or device l ISI on G Click the Software bra nc h Create a new target or device by type Development Module Software Bee Corns veer ster H Click the Add Remove Software button T a PastValidation F D E SO Real Time Desktop 5 P H Real Time PXI l Select the software to install on the NI CVS 1450 device D Plug the 4 position connector from the power supply into the power receptacle ni com vision National Instruments All rights MiMi ce on the NI CVS 1450 device LabVIEW Real Time Software Wizard oe oe ry E Plug the power cord into the power supply D When prompted insert the NI Vision Acquisition Software CD select the features to install and installed components to uninstall FEiNsTRUMENTS E Plug the power cord into an outlet TnsertSurce B j National Instruments Real Time Software To install or Ki z il B E lf m Data uninstall software click on the icon and select the appropriate Once connected the NI CVS 1450 device runs a startup program that acquires images and NI Vision Acquisition Software LabVIEW Real Time 8 0 option From the drop down menu ox cancel ote Modbus I O Server 1 0 0 displays them on the monitor These images verify that the hardware is properly connected TAE NI 1394 External Drive Support 1 3 3 3 0 F Click Next Create n
14. tall LabVIEW 8 0 7 Password protect Reset F Halt system if TCP IP fail ves Caution Before installing NI CVS 1450 Series hardware refer to the safety View Readme Model pT information in the N CVS 1450 Series User Manual Paes p elek ine snap button pea ean aaa E Exit a single image or click the Grab z x ouar button to acquire continuous Connect the Camera and Monitor to the NI CVS 1450 Device WIEW 8 none q a l M eee ye A Connect the VGA Cable o ee A i com labvi A 7 from the monitor to ne E connected ERa 7 Acquire an Image using the LabVIEW Real Time Module the VGA port on the r NI CVS 1450 device A Launch Measurement amp Automation Explorer MAX and expand the Remote Systems A Launch LabVIEW and select to Cieale hew LabVIEW Real Time project B Plug the IEEE 1394 branch of the configuration tree create a new Real Time Project A u g t e f Select project type name and folder ble i f th lt D Es inser the LabVIEW Real Time Module CD When the installation screen appears B Click 192 168 10 12 to display the Network Settings window This IP address is assigned to B Select Custom project for the Project type i Eable Into ong ene K2 click Install LabVIEW Real Time Module and follow the setup instructions 4 Sem pees Ww se IEEE 1394 ports on the i all unconfigured NI CVS 1450 devices Project type enter a Project name Se llc NI CVS 1450 device select the Project folder where you Seclin tis bos l restiet options on
15. the Software Configure the NI CVS 1450 Device 4 Acquire an Image Note You must install LabVIEW the LabVIEW Real Time Module and the NI Vision Obtain an IP Address You can acquire an image using MAX or the LabVIEW Real Time Module Development Module software before installing the NI IMAQ for IEEE 1394 Cameras GaN EM LES Acquire an Image using MAX LabVIEW Real Time Module with the aie Coron O 4 OOO a ae Configuration Al J keot Blok Refresh Bape show Hela A Launch MAX nS BEI x Install LabVIEW and the LabVIEW Real Time Module TO T RE REEE TS a A ese aint ae eo Rem nee aoe p E Software Modet NI 1450 Series B In the MAX configuration tree Ogee ruins N Vi SI 0 n D eve l 0 me nt M 0 d T e A Insert the LabVIEW CD When the installation screen appears click Install LabVIEW and S Bae nar eaud ihe device falar Ea follow the setup instru ctions fi 327681012 MAC Address 00 80 2f 0a 57 c1 a Name Pavaiaaon wD i Pesan eA Ia 1901601012 C Expand Devices and Interfaces Ser tne stem State isconnecte WF address 100 1U ERE NEIMAG IEEE 199 Device j Subnet mask 255 255 255 0 r e hani Ea Aa D Expand NI IMAQ IEEE 1394 Devices Connect the Hardware Welcome to LabVIEW 8 0 bewsa ma eS L Select a camera we f Ins