Home
User`s Manual Centrifugal Roof Fans
Contents
1. R alnor systemy wentylacji User s Manual Centrifugal Roof Fans Models DV ROF V 225 DV ROF V 315 DV ROF V 355 DV ROF V 400 DV ROF V 450 DV ROF V 500 Manual Roof fans DV ROF V Safety warnings e These fans contain rotating parts and electrical connections Therefore pay attention to safety warnings during their e assembly maintenance and operation e Electrical connections and assembly must be made by authorized persons e Electrical connections of the fan should not be damaged when the ceiling or the wall is drilled or broken e The product must have an air duct of its own e During transport operation and maintenance hands should be protected with gloves against cuts e The fan should in no way be touched while operating e Proper cleaning should be done with periodic intervals otherwise the product might be harmed e Keep the fan away from children and do not let unauthorized people to use it e Do not use do product at ambient temperature over 40 C e We herewith declare that our products do not contain asbestos mercury PCBs polychlorinated biphenyls deemed harm ful to human or environmental health Dimensions DZ 5 O 9 b O G 2 J T Q gt S z S Type A B C D E F G DV ROF V 225 350 295 190 335 146 245 10 DV ROF V 315 552 450 330 505 185 450 10 DV ROF V 355 745 607 385 595 234 450 10 DV ROF V 400 745
2. correctly and safely e Be sure that safety equipment is connected correctly e Properly establish earthing connections e Be sure that the cable and electric connection box are closed correctly and do not admit water leakage e Air exit direction should be in the direction indicated with the label on the body There shall not be any obstacles in the air flow route ALNOR ventilation systems is a legally protected trademark and technical patent All rights reserved Manual Roof fans DV ROF V e The wings should rotate in the correct direction e While the product is operating there shall not be any vibration or internal rubbing or hitting voice due to the rotation of the fan e or the suction fan e Power supply current and frequency values shall comply with the product label e If any electricity warning device turns on electric connection should immediately be cut from the main power supply Before starting the product all the installation should be controlled again carefully e If any problem occurs please consult authorized persons In case of any defect after you have started using the product continuously the type of defect should be determined In order to remove the defect the technical service must be contacted You must not try to fix the problem yourself Defects and How to Fix Them Abnormal Situation Possible Cause How to Fix Too much sound noise Rotor imbalance Change
3. the rotor Motor is damaged Change the motor The device is not working Condensator is not working Change the condensator Faulty speed adjustment connection Check the installation assembly The device is rotating slowly Faulty connection Check the electrical connection Cleaning maintenance and transport In order to protect your product from being damage during transport The product has been packaged according to normal transport conditions In order to avoid possible damage it should always be carried in its original package e The product shall be kept in its own package in a vibration free dust free environment away from abrasive orchemical material until it isdelivered to its placeof assembly Do not accept the products which are not in their original package or which were opened before being delivered to you e The products should be stocked into the vehicle in a way to stay motionless in case of any turn over or fall down e While heavy products are being carried use appropriate lifters to protect products or the people carrying the products e All necessary measures should be taken in order to prevent damages arising from sudden and careless lifting and putting down e The products should be carried one by one carefully They shall not be thrown or carried carelessly from hand to hand After taking the product out of its package e The delivered product should be checked e The product must be checked for damage durin
4. wet cloth e The product should in no way be exposed to water or pressure water ALNOR ventilation systems is a legally protected trademark and technical patent All rights reserved 6 ct D ct O 7 2 O TX A O aoe O 9 b O G 2 J alse Q gt S z S Manual Roof fans DV ROF V Warranty and Service Dear Customer We believe that providing good service is as important as providing good products for You therefore we will appreciate any remarks concerning technical features and exploitation of our products We recommend You to use Your product according to the user s manual The warranty provided by ALNOR Systemy Wentylacji Sp z 0 0 does not cover the damages arising out of using the product under conditions other than its normal conditions of use The following conditions are also not included in the warranty 1 Damages and defects arising out of faulty usage 2 Damages and defects which occur while loading unloading or carrying the product after ithas been delivered 3 Damages and defects arising due to low or high voltage faulty electrical installation and using the product at a different voltage than the one written on its label 4 Damages and defects due to fire eathquake lightening strike etc 5 Damages occuring due to using the product under conditions not conforming to the issues stated in the user s manual The above menti
5. 607 385 595 270 450 10 DV ROF V 450 900 742 512 665 282 630 10 DV ROF V 500 900 742 512 665 320 630 12 Technical Data g 3 3 8 5 3 gt 3 amp i 8 Type a amp iv 3 V Hz WwW uf d d m3 h dB A kg DV ROF V 225 230 50 130 5 2640 850 40 7 DV ROF V 315 230 50 180 4 1430 1550 54 22 DV ROF V 355 230 50 220 6 1400 2400 56 34 DV ROF V 400 230 50 360 12 1420 3500 59 39 DV ROF V 450 230 50 620 18 1410 5000 60 51 DV ROF V 500 380 50 950 1400 7550 62 60 Markings on the products or declared values on the other printed documents has been obtained in the laboratory in accordan ce with related standards These values may vary depending on product usage and environmental conditions ALNOR ventilation systems is a legally protected trademark and technical patent All rights reserved Manual Roof fans DV ROF V Assembly INSULATION ASSEMBLY DUCT ROOF BASE 6 ct D ct O 7 2 O TX A O 1 For roof installation use appropiate roof base in order to provide correct distance from a roof 2 Use insulation material as shown in fig 3 A fan connects to assembly duct see fig 4 Secure the fan against extreme weather conditions with steel cables prevent it from falling 5 Correctly connect the power cord make su
6. eriod of the product which is purchased 4 In case the product has material work manship and manufacturing defects during warranty period the product will be repaired free of charge and expenses of any sort including labor the value of the parts replaced or any our charges 5 The consumer may request for replacement of product free of charge or price reductions in the rate of defects In case the product permanently dysfunctions due to repeating of the same defect for more than twice or more than twice or more than four different times within the warranty period In case the maximum period for repairing is exceeded In case it is determined by a written report that the defect cannot be removed by the seller agency representative impor ter or manufacturer of the product respectively in case of absence of service centres 6 The present warranty does not cover damages resulting from use of product against the instructions in the manual 7 General Administration of Protection of Consumer Rights and Competition in the Ministry of Industry and Commerce may be applied for problems regarding the warranty certificate ALNOR ventilation systems is a legally protected trademark and technical patent All rights reserved
7. g transport If there is any lost or damaged part it should immediately be nformed to the transporter or our firm verbally or by writing e Do not hold the product on its connection box or electric cables Abstain from applications which will damage the wings or the protective cage while carrying Periodic cleaning and maintenanceof the product e Before cleaning or maintenance even if the product is turned off be surethatelectric connection has been cut from the main power supply e All electrical eqipment should be regularly controlled connections should be checked and damaged or worn out cables and equipment should be replaced e Periodic maintenance should be carried out at least once every six months or more frequently depending on its frequency of use Maintenance and cleaning of the productshould be carried out by qualified staff e Check the product regularly In order to prevent dirt or accumulations in the wing motor or grill carry out the maintenan ce according to the operating conditions of the product Otherwise the expected life of your product can be substantially shortened or serious damage can occur e While cleaning the product pay attention to protecting the balance on the wing and the turbine e Bolts which might become loose during maintenance should be checked e Inappropriate parts should be immediately replaced e The product should not be cleaned with inflammable or combustible cleaners it should be cleaned with a
8. oned damages are fixed on payment In case the warranty service is unfounded the customer will be responsible for any costs associated with non warranty con ditions Assembly and transport of the product is not included in the product price Warranty deed form is available for download from our website www ventilation alnor co uk Since the invoice will be taken as reference if a misunderstanding occurs about the warranty period the user must keep the invoice and a copy of it together with the Warranty Deed If the warranty deed is altered the original serial number on the product is removed or altered the warranty deed will become invalid Warranty terms and Conditions 1 The warranty period is 24 months from the date of sale 2 The product including all its components is under the warranty of our company 3 Incase of defects with in the warranty period the period spent in repairing is added to the warranty period The repairing period is maximum 30 days This period starts from the date of delivery of the product to the services centre or in case of absence of service centre to the seller the agency there presentative the importer or the manufacturer of the product re spectively In case the defect is not repaired within 10 working days the importer or the manufacturer is entitled to supply another product with similar features until the repair is completed The warranty period of the replaced product is limited with the warranty p
9. ply to the product is switched off You should make sure of that once more while connecting facilities e Before installation please check whether the electrical connection information voltage power frequency etc which is indicated on product label is matching with mounting area specification e There is no obstruction on the Air flow way e In terms of safety ground terminal which is located in connection box should be connected to the building ground e Make sure that motor thermal and overload relay are connected properly e Product wiring electrical connections must be as in the diagram e Contact separation in all poles along with a switch that must be connected to fixed wiring installations in accordance with the rules Usage Roof Mounted Fans DV ROF V are perfect solution for ventilation needs where polluted air exhaust is at a premium DV ROF V roof fans are perfect for the places where air can not be ventilated horizontally Roof fans DV ROF V are perfect for industrial and construc tional applications in factories hospitals offices kitchens bathrooms theatres restaurants etc Users are obliged to read carefully the manual before attempting to assemble operate or maintain fans Expected life of the products is 10 years When using your product for the first time e Before connecting electric cables you must not forget to cut the power supply Be sure that electrical connections of the e product are established
10. re to look at the wiring diagram All poles of a circuit breaker mounted devices connect with the separator 6 Be sure to install according to the direction of air flow 7 Please try to run the fan after installation check for vibration and errors Wiring diagram Single phase connection Yellow Green ALNOR ventilation systems is a legally protected trademark and technical patent All rights reserved Manual Roof fans DV ROF V Three phase connection 4 5 O 9 b O G 2 J alse Q gt S z S e Products should be installed only by authorized persons e Installation of the product should be specified in the project installation to the wall or floor must be securely mounted If mounted on the wall it should be mounted with bracket or with clamps e Fan blades must be installed at least 2 3 m above floor level in case of wall installation e Fan can not be installed outside the window or wall e Necessary precautionary measures should be done to avoid back flow of gases into the chamber from outdoor gas pipe or other fuels device Wearing gloves is recommended during the assembly process e The product must be connected to the input and output channels e Turn off the power before connecting electrical cords e When mounting brackets and mounts are installed correctly make sure that they are solid enough to safely carry the weight of product e Even if main power sup