Home

OneWireless Adapter for HART Devices Specifications

image

Contents

1. Factory Identification ee RESTRICTIONS Restriction Available Only With Not Available With Letter__ Table Selection _ Selection _______ _ __ ae ee ee OWA 100 OneWireless Adapter T OneWireless and XYR are trademarks and Experion is a registered trademark of Honeywell International Inc For More Information Learn more about how Honeywell s OWA 100 OneWireless Adapter can increase performance reduce downtime and decrease configuration costs visit our website www honeywell com ps wireless or contact your Honeywell account manager Honeywell Honeywell Process Solutions 1860 West Rose Garden Lane 34 03 43 Phoenix Arizona 85027 June 2011 Tel 1 800 423 9883 or 1 800 343 0228 2011 Honeywell International Inc www honeywell com ps hfs
2. Technical Information Honeywell OneWireless Adapter for HART Devices Specifications Model OWA 100 34 XY 03 43 June 2011 Introduction The Honeywell OneWireless Adapter 100 allows you to easily gain access to the information locked in your wired HART devices and bring it into any ISA100 11a compliant control system Save time and money by avoiding the cost of installing long runs of cable to your installed HART devices by using the OneWireless Adapter Improve the monitoring capabilities by automating the collection of information from these remote field devices by just adding the adapter to these 2 or 4 wired HART devices that can either be difficult or cost prohibitive to reach The OneWireless Adapter utilizes the proven radio electronics of the XYR 6000 family of transmitters providing a proven and reliable solution for getting the data wirelessly from any HART device ARNG The OneWireless Adapter adds to the Honeywell OneWireless and XYR 6000 line of wireless products allowing you to add wireless communications to almost any measurement point Using the OWA 100 es OneWireless Adapter customers can obtain data to 2 create information from remote hazardous 4 measurement locations without the need to run wires _ where running wire can be cost prohibitive and or difficult if the measurement is in a hazardous location The a
3. Temp 40 C lt Ta lt 85 C Encl Type 4x IP46 IECEx DEKRA Intrinsic Safety Ex ia IIB T4 Ex tb T90 C IP66 Amb Temp 40 C lt lt 70 C Encl IP66 IECEx DEKRA Non Sparking Ex IIB T4 Gc Zone 22 Ex tb IIIC T90 C IP66 Dc 40 C lt Ta lt 85 Encl IP66 ATEX DEKRA Intrinsic Safety Ex 1G Exia IIB T4 II 1 D Ex tb T90 C IP66 Amb Temp 40 C lt Tas 70 C Encl IP66 ATEX DEKRA Non Sparking Ex G Ex nA IIB T4 Il 3 D Ex tb IIIC T90 C IP66 40 C lt Ta lt 85 C Encl IP66 4 OneWireless Adapter OWA 100 Wiring SPLICE CONNECTOR y A sv 4 20 mA LOOP 4 20 mA LOOP 4 20 mA HART 4 20 mA HART Figure 2 OWA 100 TWO WIRE CONFIGURATION HART DEVICE wi ae i ama L 1 OWA 100 JUNCTION BOX Figure 3 OWA 100 AS A ROUTER NO WIRED DEVICE OneWireless Adapter OWA 100 5 HOST TRANSMITTER SPLICE CONNECTOR Ca CONTROL ASSOCIATED a EQUIPMENT EQUIPMENT LL 7 CONDUIT YEL BLU aaa Comes 4 20 4 20 HOST MAY HAVE LS JUNCTION BOX Figure 4 REMOTE INSTALLATION Dimensions mm inches Ha a gt n Figure 5 Example of typical mounting position Typical mounting dimensions for reference only OD OneW
4. dapter can be installed on an existing 2 or 4 wired _ HART device and operational in minutes quickly Figure 1 OneWireless Adapter OWA 100 providing information back to your control system These applications can also configure the HART device The OneWireless Adapter is part of the Honeywell over the network OneWireless system and is ISA100 11a compliant The Honeywell OneWireless Network ensures reliable Each OneWireless Adapter can scavenge power from the and fast transmission of field information into 4 20ma loop in addition to being battery powered by a PKS or any other control system wirelessly via OPC client long life D size lithium battery The OWA 100 Adapter s or Modbus TCP transmission range is 1 000 ft 305 m line of site LOS under ideal conditions The OWA 100 will transmit the HART PV s and diagnostic data over the Honeywell OneWireless network The four e Measure remote access points simply safe HART PVs can be viewed using a standard internet and securely browser through the Wireless Device Manager s user interface This interface is the same user interface used for configuring and viewing the entire OneWireless network Implement the value of wireless technology today e Gain wireless access to HART information e Obtain and utilize previously inaccessible information due to high wiring cost or hazardous locations The diagnostic data is passed from the HART transmitter Pasy me
5. et ve culrements through the OneWireless network FDM AMS or some e Improve process efficiency similar application running on the user s process control system is able to read the HART data from the transmitter wirelessly through the OneWireless network e Increase productivity by eliminating manual field readings of instruments 2 OneWireless Adapter OWA 100 Operating Conditions Parameter Reference Rated Condition Operative Limits Transportation and Condition Storage pc ec ce F Ambient 40 1085 4010 185 40 085 4010 185 40 10 85 40 to 185 Humidity RH 10 to 55 O to 100 to 100 0 to 100 Vibration Maximum of 4g over 15 to 200 Hz Maximum of 40g Battery powered 3 6V Lithium thionyl chloride LiISOCI2 battery non rechargeable size D Connected into a powered 4 20 mA loop power supply 7 to 30 Vdc 25 mA for power scavenging maximum loop voltage drop due to adapter is 2 52 Vdc over the ambient temperature range across the loop minimum loop load resistance is 250 Ohms Battery life reference conditions with 30 second publish cycle time set for non Routing is 3 years The ambient limits shown are for ordinary non hazardous locations only Refer to the appropriate control drawing FM CSA ATEX or IECEx for the ambient limits when installed in hazardous locations Physical Specifications 7 NPT or M20 316 Stainless Steel fitting that allo
6. ireless Adapter OWA 100 Model Selection Guides are subject to change and are inserted into the specifications as guidance only Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at http npsweb honeywell com Cultures en US Products Instrumentation ProductModelSelectionGuides default htm Model Selection Guide 34 XY 16 93 Section 13 Honeywell 1 of 1 OneWireless Adapter Model Selection Guide OWA 100 Model Selection Guide 34 XY 16 93 Issue 1 Instructions Select key number e Make one selection from each table and Il using the column below the proper arrow e denotes unrestricted availability Aletter denotes restricted availability Key Number ll lll WA100 _ ___ KEY NUMBER Availability Description _______ OneWireless Adapter Table Options M20 316 SS Conduit Adaptor 1 2 NPT 316 SS Conduit Adapter Battery Holder Only No Battery Included Battery Power Location or Classification see listing below No approvals CSA cus IECEx amp ATEX Factory Mutual No Selection No Selection Manual Option User Manual CD User Manual Paper Copy None Certificate of Conformance F3391 Certificate of Origin 50195 Certificate of Origin FO0195 Conformance 3391 Table Il Country Code Description North America Canada European Union Table Ill Factory Use
7. wo OWA s both having TX Power set to 14 dBm with a clear line of site nominal signal range is 240 m 790ft An XYR 6000 transmitter having TX Power set to 16 dBm and an OWA with TX Power set to 14 dBm with a clear line of site nominal signal range is 170 m 560ft OneWireless Adapter OWA 100 3 Parameter Specification Unit can be set as a Field Routing or non Field Routing device the number Routing vs non of routing devices is set by the system manager Routing Using the device as a routing device will impact battery life the more messages routed through a device the greater the impact on battery life CE Conformity These transmitters conform with the protection requirements of European Council Directives 2004 108 EC the EMC Directive and 1999 5 EC the Radio amp Telecommunications Directive per EN 300 328 V1 7 1 2004 11 EN 300 489 1 V1 6 1 2005 09 EN 300 489 17 V1 2 1 2002 08 EN 301 893 V1 4 1 and EN 61326 1 2005 Electrical Equipment for Measurement Control and Laboratory Use EMC Requirements Actual range can vary depending on site topography Hazardous Location Certifications c CSA us Intrinsic Safety Entity CL I II Ill 1 GPs T4 Ta 85 Ex ia IIB 4 Ex tb IIIC T90 C IP66 Amb Temp 40 C lt Ta lt 70 C Encl Type 4x IP46 c CSA us Non Incendive CL I Div 2 GPs CD CL II Div 2 GPs F amp G Suitable for CL III Div 2 T4 CL I Zone 2 AEx nA IIB T4 Amb
8. ws the adapter to be attached directly to the conduit entry of any 2 or 4 wire HART device standard options Mounting should result in the antenna being vertically oriented An optional Remote Mounting Kit is available Molded Polycarbonate UL rating of 11 for outdoor use UV stabilized and 0 rating Meets Type 4X hosedown and corrosion resistant 66 dust tight nosedown Net Weight Approximately 1 0lb 0 45Kg Specifications Input _______ Any 2 or 4 wire HART device Wireless Communication SA100 11a Compliant 2 400 to 2 4835 GHz 2 4 GHz Industrial Scientific and Medical ISM band per FCC 15 247 IEEE 802 15 4 2006 Every data packet transmitted in either direction is verified CRC check and acknowledged by the receiving device USA FCC Certified Canada IC Certified European Union RTTE ETSI Conformity RF Transmitter Power NA Selection 125 mW 20 9 dBm maximum transmit power not including antenna per FCC IC or 400 mW 26 0 dBm maximum EIRP including antenna for USA and Canadian locations EU Selection 10 mW 10 0 dBm maximum EIRP including antenna per RTTE ETSI for EU locations PV Data Publish Cycle Time Configurable from 5 seconds to 1 minute HART PV every 5 seconds minimum Rate 250 Kbps ISA100 11a Compliant output Integral 2 5 dBi omnidirectional monopole Signal Range OWA 100 Adapter to FDAP Nominal 305 m 1 000 feet with a clear line of sight T

Download Pdf Manuals

image

Related Search

Related Contents

Manual do Usuário  Manual de instrucciones User manual Manual de instruções  KitchenAid KCDP 9010/I cooker hood  Marantz CD5003 CD Player User Manual  Manual PDF  Laboratory Manual - Journal of the Australian Mathematical Society  Powermate PM0101207.01 User's Manual  MISE en page JUIN 2013 2  シングルレバー混合水栓  Approx appKBTV02  

Copyright © All rights reserved.
Failed to retrieve file