Home

Loop-IP6700 TDMoEthernet

image

Contents

1. mws a LOoop 1P6700 E ATAYA i TDMoEthernet iT CONSOLE CON mR s a Description The Loop IP6700 TDMoEthernet is an ideal solution for transporting varied TDM traffic over IP networks As the core communications network migrates from Circuit Switched Network to Packet Switched Network the Loop IP6700 provides a flexible and cost effective choice On the WAN side the Ethernet interface can be 10 100 BaseT or 100 BaseFX For the User Tributary interface the TDM Tributary interface can be either multiple E1 or T1 or serial or E3 DS3 The Ethernet Tributary interface can be 2 10 100 BaseT ports Loop IP6700 converts the TDM data stream and timing information into packets and transmits to the connected Packet Switched Network Another Pseudowire device converts the received packet stream back to original TDM data stream along with the original timing information The Loop IP6700 has built in AC or DC power Management choices include DB 9 console port Ethernet port and SNMP port with default IP address in addition to Inband management for communication with remote management centers For transport of TDM signals the Jitter and Wander adheres to G 823 G 824 Traffic Interface and G 823 G 824 Synchronous Interface when OCXO is selected in order to provide excellent clock traceability and stability The IP6700 s Ethernet uplink can further be uploaded into other equipment such as microwave and wireless lin
2. Main unit Loop IP6700 S EL PPM E75 E75 22 22 AC TP2 gt A low speed unit with G 823 G 824 traffic 1 electric Ethernet WAN port 2x E75 ports two V 35 ports 100 to 240 Vac power and temperature range from 0 60 C Examples 3 Main unit Loop IP6700 S OH PPB AC TP1 gt A high speed unit with G 823 synchronous an optical Ethernet WAN port one E3 DS3 100 to 240 Vac power temperature range from 0 50 C Examples 4 Main unit Loop IP6700 S OL PPB E120 E120 22 22 AC TP2 gt A low speed unit with G 823 synchronous an optical Ethernet WAN port two E120 ports two V 35 ports 100 to 240 Vac power and temperature range from 0 60 C et WATOA E vv aw E Telecom Loop IP6702 TDMoEthernet TDMoE Specifications SFP Optical Module Please refer to SFP optical module brochure for detail WAN Interface Number of Ports 1 Electrical port or 1 Optical port Electrical Port Optical Port Speed 10 100 BaseT 802 3i 802 3u Speed 100 BaseFX 802 3u Auto negotiation 10 100 Connector SFP Auto MDI MDIX Full nalf Duplex Connector RJ45 Ethernet Tributary Interface Number of Ports 2 Speed 10 100 BaseT 802 3i 802 3u Auto negotiation 10 100 Auto MDI MDIX Full Half Duplex Connector RJ45 E1 Tributary Interface Number of Ports 1 4 Input Signal ITU G 703 Line Rate 2 048Mbps 50 ppm Output Signal ITU G703 Line Code AMI HDB3 Jitter and Wander ITU G823 Framing ITU G704 Impedance 75 ohm coax 120 ohm twisted p
3. Management High Speed TDM Application Tributary ports IP6700 IP6700 TDMoEthernet TDMoEthernet E3 DS3 WAN port IP 3 DS3 Network gt 0 Lea ae o 0 te W o 4 Electrical Ethernet yi os Lan _ n 10 100 BaseT or E LAN 10 100 Optical Ethernet 10 100 BaseT 100 BaseT BaseT LAN2 100 Rase Lanz SNMP Management IP6700 Clock Option To set same clock source to all remote To set different clock source to different v0 606 E1 T1 7 3 5 i 606 60 FES 19100Mbps gt 1P6700 eal s o Wa aa ane remote units Remote Remote waasisi IP6700 Taa Master IP6700 FE YA iis 7 l a ops IPA poe Jea ae C cw ey aaa O IP __ E ies PSS a P6700 MPLS oO f z o 10 100Mbps l I FE x N 10100Mbps IP6700 i _ J Master Clock Source NOTE If independent clocks are used with T1 signals and the WAN port is transported over a wireless network then a possibility of an occasional 1 second pattern loss exists IP6700 Extension Phone System Telecom Loop IP6702 TDMoEthernet TDMoE a a Site A F usc at oan ae PBX IP6700 on VPN Network Sz uu 9 aa suma SSE Basses X21 10 100B JE aseT wi oe GK 10 100 BaseFx AI Building A j lt _ WAN VPN _ _ KF Network Ea a 10 100 BaseT 10 100 BaseT lt 10 100 BaseFx 10 100 BaseFx Building B a 10
4. keypad e LCD is supported for ANSI shelf only e LCD only supports the temperature range of 0 50 C m Where temp is used to select the temperature range This module must be selected one from the list below temp Description Note TP1 Temperature range from 0 50 C TP2 Temperature range from 0 60 C Accessories Model Description Note User s Manual Loop IP6700 UM User s Manual optional paper hard copy A CD version of the manual is included with every order Firmware Upgrade Loop IP67003 FWUPGR_ Firmware Upgrade Customers who desire to have a firmware upgrade after their warranty has expired can purchase this option This will upgrade the firmware to the most current version and provide an additional 12 months of software repair and patches on existing functionality as necessary Power Cord Loop ACC PC USA G AC power cord for Taiwan America a Loop ACC PC EU G AC power cord for Europe a Loop ACC PC UK G AC power cord for UK zs _ NX Loop ACC PC AUS G AC power cord for Australia NX Loop ACC PC CH G AC power cord for China i SFP Optical Modules Please place your order using the 5 digit alphanumeric codes listed in the separate SFP Optical Module Brochure Ordering Examples Examples 1 Main unit Loop IP6700 S EH PPM AC LCD TP1 gt A high speed unit with G 823 G 824 traffic 1 electric Ethernet WAN port 1x E3 DS3 100 to 240 Vac power LCD and temperature range from 0 50 C Examples 2
5. 100 Base 10 100 BaseT 2 7 10 100 BaseFx TOON SaSe RA Building C aw at a E WAVAVI UA LoopTelecom com Worldwide Taipei Taiwan 8F No 8 Hsin Ann Road Hsinchu Science Park Hsinchu Taiwan 30078 886 3 578 7696 www looptelecom com sales loop com tw 2013 Loop Telecommunication International Inc Version 29 29 March 2013 po ae FE 6F No 36 Alley 38 Lane 358 Rueiguang Road Neihu Taiwan 11492 886 2 2659 0399 michael_tzeng loop com tw IP MPLS Network All Rights Reserved X20 lt o zi aa _ Fi 022 ave ae _ ee d Building A w 2 gt Co w Le a CCC C O 2 ai OQ WWW C LLL 2 5 LOOP TELECOMMUNICATION INTERNATIONAL INC ISO 9001 ISO 14001 North America 8 Carrick Road Palm Beach Gardens Florida 33418 U S A 1 561 627 7947 jimber561 aol com Tianjin China No 240 Baidi Road Nankai District Tianjin 300192 China 86 22 8789 4027 wym loop tj com Subject to change without notice vV aa ya Telecom
6. Depth For E1 Up to 256 ms For Unframed T1 Up to 340 ms For Framed T1 Up to 256 ms For Framed T1 with CAS Up to 192 ms For Unframed E3 Up to 60 ms For Unframed DS3 Up to 45 ms Timing Source Primary Secondary Clock Internal Line A B C or D Adaptive Clock Recovery External for low speed tributary port E1 T1 serial only manufacture option External Timing Alarm Relay Input Signal E1 2 048M bps 2M bps 75 ohm Alarm Relay Fuse alarm performance alarm Connector BNC Connector 3 pin terminal block Maximum Current 1A for 30 Vdc 0 3A for 125 Vac Network Management Console Port SNMP Port Electrical RS232 interface Protocol SNMP v1 v3 Terminal Menu driven VT 100 Connector RJ45 at front panel Connector DB9 female serial Inband Management Through any one time slot 64K bps for low speed ports E1 T1 with frame mode only HDLC and PPP management protocol Performance Monitors E1 T1 Performance Store The last 24 hour performance in 15 minute interval Performance Reports Date amp Time Error Second ES Unavailable Second UAS Bursty Errored Second BES Severe Error Second SES Controlled Slip Second CSS and Loss of Frame Count LOF Alarm Reports E1 T1 Alarm History Date amp time alarm type i e master clock loss RAI AIS LOS BPV ES CSS Alarm Queue Contains up to 160 alarm records of latest alarm types alarm severity date and time Currently Active Alarm Summary CAAS Diagnostics T
7. PPM a IP6700 with G 823 G 824 traffic interface 1 electric Ethernet synchronous interface a bb cc dd pp add temp G WAN port 1 LAN port 1 SNMP port and low speed interfaces G823 for E1 G824 for described below T1 Loop IP6700 S OH PPM IP6700 with G 823 G 824 traffic interface 1 optical Ethernet pp add temp G WAN port 1 LAN port 1 SNMP port 1x E3 DS3 high speed e High Speed for E3 DS3 interface SFP optical module is not included only E3 DS3 software Loop IP6700 S OL PPM a IP6700 with G 823 G 824 traffic interface 1 optical Ethernet Programmable a bb cc dd pp add temp G WAN port 1 LAN port 1 SNMP port low speed interfaces Low Speed for E1 T1 and described below SFP optical module is not included serial interface Loop IP6700 S EH PPB p IP6700 with G 823 G 824 synchronous interface 1 electric p add temp G Ethernet WAN port 1 LAN port 1 SNMP port 1x E3 DS3 high speed interface Loop IP6700 S EL PPB a IP6700 with G 823 G 824 synchronous interface 1 electric a bb cc dd pp add temp G Ethernet WAN port 1 LAN port 1 SNMP port low speed interfaces described below Loop IP6700 S OH PPB p IP6700 with G 823 G 824 synchronous interface 1 optical p add temp G Ethernet WAN port 1 LAN interface 1 SNMP port 1x E3 DS3 high speed interface SFP optical module is not included Loop IP6700 S OL PPB a IP6700 with G 823 G 824 synchronous interface 1 optical a bb cc dd pp add temp G Ethernet WAN port 1 LAN port 1 SNMP port lo
8. air CRC on off CAS on off unframed Connector BNC RJ48C NOTE E1 T1 is jumper selectable T1 Tributary Interface Number of ports 1 4 Input Signal DS 1 from 0 dB to 26 dB w ALBO Line Rate 1 544M bps 32 ppm Output Signal DSX 1 DS 1 Line Code AMI B8ZS Pulse Template Per AT amp T TR 62411 Framing D4 ESF ESF amp T1 403 NONE clear Impedance 100 ohm twisted pair channel Connector RJ48C NOTE E1 T1 is jumper selectable Serial Tributary Interface Number of Ports 1 2 Type DCE Line Rate n x 56K bps n 1 to 31 or n x 64K bps n 1 to 32 Interface Connector V 35 DB25S EIA530 DB25S X 21 DB15S via DB25P to DB15S conversion cable V 36 RS449 DB37S via DB25P to DB37S conversion cable RS422 V 11 DB25S E3 Tributary Interface Number of ports 1 Output Signal ITU G 703 Line Rate 34 368M bps 4 6 pom Output Mask ETS 300 689 Sec 4 2 1 2 ITU G 703 Line Code HDB3 Jitter and Wander ITU G 824 Framing Unframed Impedance 75 ohm coax Input Signal ITU G 703 Connector BNC connector NOTE E3 DS3 is software selectable DS3 Tributary Interface Number of ports 1 Output Signa l ITU G 703 Line Rate 44 736M bps 4 6 ppm Output Mask Bellcore GR 499 core Line Code B3ZS Jitter and Wander ITU G824 Framing Unframed Impedance 75 ohm coax Input Signal ITU G 703 Connector BNC connector NOTE E3 DS3 is software selectable Telecom E WAA TA Loop IP6702 TDMoEthernet TDMoE Packet Delay Variation Compensation
9. ction e ARP Ping and Trace Route e IP MAC Table Display e Pseudowire Information Packet Creation Time ms Jitter Tolerance Delay ms Single Trip Delay ms Total Frame Length bytes Packet per second Required Bandwidth Mbps Header Overhead Jitter and Wander e PPM version Conforms to G 823 G 824 Traffic Interface e PPB version Conforms to G823 G 824 WAVAVI Synchronous Interface Timing Reference e Internal e External BNC connector e Line E1 T1 e Adaptive Clock Recovery All Pseudowires can apply ACR OAM Capability Supports 2 SNTP Timing References Multi color LED indicators Alarm relay ACO Alarm Cutoff button Management Interface 1 user selectable Ethernet SNMP port SNMPv1 v3 LCD and keypad DB 9 Console port with VT100 menu Telnet and SSHv1 SSHv2 C VLAN S VLAN tag on management traffic LoopView GUI Inband management through one time slot 64Kbps Standards Compliance e TDMoIP SAToP CESoPSN MEF 8 Future option Telecom Loop IP6702 TDMoEthernet TDMoE Ordering Information Note RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code Main Unit Model Description Note Loop IP6700 S EH PPM p IP6700 with G 823 G 824 traffic interface 1 electric Ethernet e PPM G823 G 824 p add temp G WAN port 1 LAN port 1 SNMP port and 1x E3 DS3 high traffic interface speed interface e PPB G823 G 824 Loop IP6700 S EL
10. est E1 T1 Loopback Line loopback Payload loopback and Local loopback Remote Loopback Payload loopback Power Physical and Environmental AC Module 100 to 240 Vac 50 60 Hz Dimensions 212 6 x 44mm x 197 mm W x H x D DC Module 36 to 72 Vdc Net Weight 1 8 kg Consumption Maximum 10W Temperature 0 50 C or 0 60 C Humidity 0 95 RH non condensing Mounting Desk top stackable 19 rack mountable Standards Compliance IEEE ITU 802 1p Priority Code Point G 703 E1 DS1 802 19 VLAN Tagging G 704 DSO 802 1ad Q in Q G 706 Frame Alignment and CRC IETF G 823 G 824 Traffic and Synchronous Interface RFC3411 SNMPvV1 v2c v3 G 826 End to End Error Performance RFC4553 SAToP PWE3 Pseudo Wire Emulation Edge to Edge RFC5086 CESOPSN V 11 Balanced Interface with a Maximum Data Rate of 10Mbps RFC5087 TDMolP RoHS Restriction of Hazardous Substances Directive MEF 8 CESoETH Certifications EMC EN55022 Class A EN50024 EN300 386 FCC Part 15 Subpart B Class A Safety IEC60950 1 CB EN60950 1 CE Telecom E WAA TA Loop IP6702 TDMoEthernet TDMoE Application Illustrations Low Speed TDM Application Tributary ponts IP6700 Electrical Ethernet IP6700 10 100 BaseT or TDMoEthernet aie TDMoEthernet Optical Ethernet E1 T1 E1 T1 100 BaseT IP E1 T1 E1 T1 DTE lt Network usa E1 T1 DTE E1 T1 DTE a 2o Ti WAN port a o ii ENTI DTE LAN ee m Ba 10 100 10 100 BaseT LAN2 BaseT LAN2 SNMP
11. ks for applications like emergency services and public transportation Features Mechanics and Electrics L2 Switching Capability e ANSI shelf e Jumbo frame size up to 1916 bytes e Power Module Single AC or DC power a transparency Maximum 4K VLAN ID WAN Interface Maximum 16 con current VLAN Groups e 1 Electric Ethernet 10 100 BaseT port or 1 Supports C VLAN S VLAN tag adding and Optical Ethernet 1 00 BaseFX port removing on Pseudowire Supports 802 1q Port Based VLAN on User Tributary Interface Ethernet SNMP Port e TDM Tributary interface e Supports 802 1d MAC Learning Up to 4 E1 T1 e Supports 803 3x Flow control on input ports Up to 2 serial V 35 or EIA530 or X 21 or V 36 RS449 or RS422 V 11 QoS 1 E3 DS3 l l e Ingress Rate Limiting per Ethernet port with e Ethernet tributary interface 32Kbps granularity 1x 10 100 BaseT Ethernet port plus 1 e IP Network Level user selectable 10 100 BaseT 6 bit DiffServ Code Point DSCP field ToS Ethernet SNMP port Aas E WAA Ja Pseudowire Capability e Supports TDMoIP AAL1 SAToP CESoPSN and MEF 8 e Supports E1 T1 traffic emulation over UDP IP and Ethernet network e Supports Timeslot Grooming e Maximum 64 pseudowires e PDV Compensation Depth E1 up to 256ms T1 up to 340ms Jitter Buffer size 1 ms to 512 ms e Minimum packetization latency lt 1 ms e Excel calculator is provided Pseudowire Diagnostics Function e Built in BERT for E1 T1 to Line or WAN dire
12. w speed interfaces described below SFP optical module is not included m Where aa and bb are used to select connector If these modules are not required leave this field blank aa bb Description Notes E75 E1 75 ohm with BNC connector e 75 ohm 120 ohm is E120 E1 120 ohm with RJ48C connector software selectable T1 T1 with RJ48C connector m Where cc and dd are used to select connector If these modules are not required leave this field blank cc dd Description Notes E75 E1 75 ohm interface with BNC connector e 75 ohm 120 ohm is E120 E1 120 ohm interface with RJ48C connector software selectable T1 T1 interface with RJ48C connector 22 V 35 interface with DB25 female connector 33 EIA530 interface with DB25 female connector 44 X 21 interface via DB25P male to DB15S female 1 feet conversion cable 66 V 36 RS449 interface via DB25P male to DB37S female 1 feet conversion cable 77 RS422 V 11 interface with DB25 female connector m Where pp is used to select power module This module must be selected one from the list below pp Description Notes AC Single AC power plug in module 100 to 240 Vac e For AC choose an DC Single 48Vdc power plug in module 36 to 72 Vdc appropriate power cord et ATATIWA i vv aw E Telecom Loop IP6702 TDMoEthernet TDMoE m Where add is used to select the LCD and keypad If these modules are not required leave this field blank add Description Note LCD Front panel with LCD and

Download Pdf Manuals

image

Related Search