The Manual of KL8500

image

Contents

1. 5 The 4th time to press button then the system goes into standard mode the screen shows Sz The button backlighting is double color 4 Automatic frozen preventing function When the water temperature is below 44 F 6 7 C or much lower the function of anti freeze is automatic starting all the pumps and air pumps work for 30 seconds and then ie a turn off All the heaters and circulating pumps turn on The panel shows L E When the water temperature is reaching 44 F 6 7 C or above all the heaters and circulating pumps stop working V Clock setting At clock setting status show as Fig 3 to press the button to set the hour down button the adjusting range is from 0 to 23 And to press the button to set the minute up button the adjusting range is from 0 to 59 LY le NI LL tc www ethink spa com www ethink cn com 4 Ve The Manual of KL8500 Fig 3 It is 12 34 now Fig 4 The starting time for filtering is 3 00 VI Pre settings filtering antivirus cycle Valid of A1 off 1 When A2 ON the time for filtering antivirus is fixed It starts to work at 14 00 every day and it will last for 3 hours 2 It is only able to set the starting time for the first filtering antivirus cycle The setting of the filtering time can be1 11hours The default time is 3 hours 3 When A3 OFF it has twice filtering antivirus cycle every day And the second filtering cycle is
2. Keep pressing button for more than 5 seconds until it appears a IN flashing E L on the screen it means that the system is entering to the setting pattern and at the same time it also enters to a real time clock setting 2 Under the setting mode click on to set open time of filter cycle the screen shows F5 E CE er FR 3 The 3rd time to click on to set timer of filter the screen shows l 4 The 4th time to click on CMD to set tuning temperature the screen shows Ad J 5 The 5th time to click on back to forced drainage setting the screen shows Ou 6 The 6th time to click on CM back to real time clock setting and the screen shows flashing I E L When finish the setting or being without pressing any setting button within 6 seconds the data will be saved and then it exits the setting pattern Any modification must be operated within 6 seconds NOS 1 When A1 ON or A2 ON then it skips the 2nd and 3rd steps 2 When B4 OFF it skips the fifth steps 3 Only button has the operation of keep pressing and click pressing the other buttons are click pressing 4 Keep pressing means to click the button and hold until it appears some icons or enters to a certain status 5 Click pressing means to click the button and let go right now within 1 second Iv Working Mode 1 Three kinds of wo
3. 8W Not being punctured www ethink spa com www ethink cn com 11
4. The function of moisturizing and forced drainage 16 Error code hinting II Function Description Initial electrical testing During the whole process of the initial electrical testing LED shows Pr HE 1 Overvoltage testing When it is initial to power on the system is working under a protecting status The system is testing the voltage from the input transformer when the input voltage is Vf beyond 280VAC LED shows EL H then the system stops working If the input voltage is below 280VAC the system will go into normal power supply In anormal power supply turn off all the load and then test the input voltage again It is normal working voltage if the voltage shows below 260VAC It is the over voltage if it is 11 beyond 260VAC then LED shows uO In these two kinds of situation the system will not go into normal operation II Temperature Settings 77 104 F 25 40 C In the status of being without any settings the first time to press Avr button it can enter to the setting status of temperature At this time the setting temperature is flashing in the screen Before the temperature stop flashing press the Aor button again it can change settings temperature Within 6 seconds without any pressing button it will exit and save settings temperature and begin to show the current SPA temperature www ethink spa com www ethink cn com 2 Ve The Manual of KL8500 HI The Operation of Button 1
5. automatic added it will start after 12 hours later For example it starts at 14 00 and the second filtering time is at 2 00 4 In the setting status of starting time of filtering cycle show as Fig 4 Press the NO button to change starting time and both hour and minute are 00 5 In the setting status of continuous working time of filtering cycle press button to change the time the settings are1 11 hours and the default time is 3 hours show as Fig 5 6 At the initial stage of each filtering cycle all the devices will run for 15 seconds to purify the pipeline equipment Ozone will start to work 15 seconds later In order to prolong the service life of anti virus system every 15 minutes ozone stops working for 15 minutes When any surfing pump or high speed pump and air pump is power on the anti virus system will stop working at once VII temperature Adjust Keep pressing button to enter to the setting mode and continuous press i button to enter to temperature adjust mode show as Fig 6 At this moment to press OD button and AD button can change the fine tune number adjusting range is 7 7F If the current water temperature shows 98 F but the real water temperature is 100 F At the moment as long as to adjust the fine tuning number for 2 F then the showing temperature will turn into 100 F Ci l LA AS Fig b filtering lasis for 3 hours Fig 6 Temperature A
6. cables about the water probe are normal or not EUH Input voltage is more than 280 10V Whether Power input line is wrong to connect Elo Input voltage is more than 260 5V Check input power supply voltage Flo The working current of underwater lamp is over limit Whether underwater light interface is short circuit or not LPD The current of circulating pump is oversize Check whether the circulation pump is jammed to cause the flow stream En Automatic moisturizing overtime 1 If there is without tap water 2 Please manual filling water to the water level probe Other operation information ER F 1 I L L It detected that it is going to freeze and it is operating the protection about anti freeze www ethink spa com www ethink cn com 10 The Manual of KL8500 PANG d 25 mM M gt The system is moisturizing and the other function can be operated normally L 3 OLI L Compulsory drainage is running VIl Electrical parameters 1 Performance index Working voltage AC220 240V 50Hz Maximum working current 48 A 220V Compression strength 1250V 1 minute Insulation resistance 200MO Waterproof level IPX5 Electric shock preventing 1 class 2 Maximum output load index Thermostatic furnace AC220V 3KW x2 Surfing pump AC220V 3HPx4 Circulating pump AC220V 1HP Air pump AC220V 800W Bottom lamp AC12V 20W or DC12V 20W Ozone AC12V
7. Tew The Manual of KL8500 I Overview of the Panel Fig 1 The panel plan of 9 buttons 200 167 OCP ARAA LIL D seers 100 ALS AUS EG 305 SSS a Fig 2 The installation plan of 9 buttons 200 100mm II The function summary 1 Plug and play mode is to get the easy operating and easy setting up 2 Three working modes Normal Standard Mode Energy saving Economy Mode and Filtering Sleep Mode 3 The clock display and function about the setup of circulation cleaning for 24 hours 4 Max 6 KW thermostat function water temperature display and the setting function 5 Max 4 surfing pumps and 1 circulating pump or 3 surfing pump and 1double speed www ethink spa com www ethink cn com 1 Vie The Manual of KL8500 pump and an air pump 6 Functions of synchronous changing color with multiple lights and fixed color bottom lamp and ozone antivirus system 7 The function of automatic water frozen preventing 8 The function of double color buttons backlighting 9 Optional inputting about one phase three phase or dual 110V optional outputting about 110 120VAC or 220 240VAC 10 A group of additional power output it can be used for DVD TV or others 11 Switchbank selecting the different functions 12 The protection of overvoltage or undervoltage 13 Low pressure part bottom lamp and ozone overcurrent protection 14 overcurrent protection of circulating pump 15
8. The Manual of KL8500 Fault Failure cause Solutions indication FEO Temperature sensor open 1 Check whether the plug loose or not and m ml AA circuit or short circuit whether cable is damaged or not CE Water flow sensor open 2 If plug and cable are intact please replace CIO circuit short circuit the mainboard rt It is detected that water flow 3 If changing the mainboard is still invalid coo sensor is over limit please replace heaters It is detected that inside the TULI heater the temperature 1 Check whether environmental temperature mt reaches 118 F 48 C or is over high more than 2 Check whether filter is blocking or just It is detected that inside the replaced T L heater the temperature 3 Check whether the metering valves and m ml I reaches 110F 43 5C or circulating pump are normal or not more than Ce The water flow inside the 1 Check whether filter is blocking or is just LI Lk heater is possibly too low replaced 2 Check whether the metering valves and BS rs It is sure that the water flow circulating pump are normal or not Er b inside the heater is not If the above is normal please turn off the enough power supply for 15 seconds then turn on the power and reset the system in an Le It lacks of water or water level is not reaching 1 Please check whether the water level is reaching the normal level or not 2 Please check whether all the
9. djust www ethink spa com www ethink cn com 5 AR The Manual of KL8500 Vill The Main Board Specifications and DIP jumpers settings show as Fig 7 A1 OFF Three working modes ON Just having standard mode and the antivirus function is of no avail A2 OFF It is able to set filtering antivirus cycle artificially ON Filtering antivirus cycle built in is unchanged It starts to work at 14 00 and it works for 3 hours A3 OFF There is twice to filter antivirus cycle every day And the second starting time to start is 12 hours later ON There is once to filter antivirus cycle every day A4 OFF Display the Fahrenheit temperature ON Display Celsius temperature A5 OFF Surfing pump1 is a single speed pump ON Surfing pump 1 is a double speed pump A6 OFF When the temperature appears abnormal all high pressure loads will stop working ON All high pressure load without heater and heat pump are not affected by temperature sensor control A7 OFF There is a flowing induction sensor when it is detected there is no flowing the heater will not work ON There is no flowing induction sensor A8 OFF There is a water level probe which controls the water pump and heater ON There is no water level probe cece munnmmnn 1234959678 12345 6 7 8 Fig 7 Switchbank A B B1 OFF When it is initial power on there is detection about inputting power supply voltage ON Without power supply voltage detection B2 OFF The air pump is not co
10. l automatically turn off when it works for 25 minutes II The operating of the air pump There is a button iB to control the air pump to be ON OFF The air pump will automatically turn off when it works for 25 minutes www ethink spa com www ethink cn com 7 Vie The Manual of KL8500 IIN gt Power supply function button Orig the button about the sound of the system or the other power supply function IV The operating of the lamp There is a button Ce to control the lamp for turning on off The lamp will automatically turn off when it works for 120 minutes V gt The operation of automatic moisturizing when A8 ON it is invalid When B3 ON and the A8 OFF the function of automatically moisturizing is effective When the water probes detect that there is no water automatic moisturizing function will start 12 VDC moisturizing solenoid valves will turn on And LCD shows in F at this time After filling water to water level probes the moisturizing solenoid valves will delay 1 minute to work then it will turn off the solenoid valves During moisturizing if it has not reached the water level probe in an hour maybe without tap water moisturizing solenoid valve will also turn off and it shows Ei MP Then it won t turn on the automatic moisturizing At the moment it can work regularly unless manual moisturizing to water level moisturizing When filling water is finished in F mark will disappea
11. ntrolled by water level probe ON The air pump is controlled by water level probe air pump loading place can be the third surfing pump B3 OFF No moisturizing function ON Auto moisturizing function B4 OFF No forced drainage ON Forced drainage www ethink spa com www ethink cn com 6 Vee The Manual of KL8500 B5 OFF 3 surfing pumps ON 4 surfing pumps B6 OFF Heater ETHINK heater ON Heater hot pump B7 OFF ON B8 OFF Normal working mode ON Testing mode noi 1 The setting of all the jumpers is effective only when it is re power on And the spacing interval for re power on is more than 60 seconds 2 All the jumpers have been set in the factory The user had better not change the product setting 3 When any surfing pump is turned on the heater stops working IV The operating instructions of output load part 1 The operating of surfing pump D Gz and Gs buttons are to control surfing pump1 2 3 to be ON OFF When there is no water in the bathtub or it is below the water level the system will display flashing after all the pumps are turning on f N When B5 ON and B2 ON amp position of the heater 2 button is to control the fourth surfing pump the When B5 ON and B2 OFF the 1st time to press D button to turn on pump2 and the 2nd time to press putton to turn on pump2 and pump 4 and the 3rd time to sesa Dipun to turn off the pump2 pump 4 The surfing pump wil
12. r It will start moisturizing function when the next water shortages VI Operation of Compulsive Drainage When B4 ON in the fifth step of the Settings mode to press button to ON OFF compulsive drainage at this time the LCD shows ON or OFF After finishing the setting according to the ON OFF instructions turn on or turn off compulsive drainage At this time all surfing pumps and air pumps will start to work to stir the water in the SPA After 15 seconds all pumps and heater will stop working and drainage solenoid valves will start When the water is below the water level probe drainage solenoid valves will delay 1 hour to work and then turn off www ethink spa com www ethink cn com 8 Vie The Manual of KL8500 WATER 000 SENSOR HT2 P4 m e 220V N Ip e e N D PUMP3 m at a HT48R10 A 1 6666866630 WSOOS OSC OC OO8O HT46R KEY TIS e A B WUDUUUDUNUDUUDUUL piL pump HEAT pump2 AUX2 BLOWER N e e e DVI e N tf e e N N t ik N N N N 0 the the the Gi Fig 8 Control box structure 1 Single phase 3 line input A1 A2 A3 ACL phase line A4 ACN zero line 2 Three phase 5 line input A1 L1 phase line 1 A2 L2 phase line 2 A3 L3 phase line 3 N ACN zero line www ethink spa com www ethink cn com 9 VI System malfunction warning
13. rking modes Normal Standard Mode Energy saving Economy Mode and Filtering Sleep Mode The work of the mode is just effective for circulation pump circulation filter of heater and antivirus function 2 When A1 ON it just has Normal Standard Mode and CM button cannot switch the working modes www ethink spa com www ethink cn com 3 Ve The Manual of KL8500 3 The switching of the modes 1 When it is power up the system is working at the Normal Standard Mode and the screen shows Std ia system is keeping setting temperature in all weather At the moment the button backlighting is double color backlighting 2 The 1st time to press button then the system enters into standard mode turning into economic mode and Sie is normally on the screen EN is flashing The system will turn into economic mode after going standard mode for an hour At the moment the button backlighting is double color backlighting 3 The 2nd time to press button then the system enters to economic mode the screen shows Ecni system is just working during the filter cycle and it will heat the SPA to the setting temperature At the moment the button backlighting is green 4 The 3rd time to press button then the system goes into sleep mode the screen shows S DA The system is just working during the filter cycle in this mode the heater doesn t work At the moment the button backlighting is blue