AY-M25 Installation & Operating Manual

image

Contents

1. Programming AUXILIARY MODE 8 Auxiliary input function Green LED control Auxiliary output activated by Valid usercode Auxiliary code Eg In auxiliary mode 8 the controllercan function asa two door controllerand also provide indicator functionality control The auxiliary relay is connected to the lock on the second door The auxiliary setting definesthe door open time forthe second door The auxilia ry input is used to control the Door indicator If the auxiliary input is open the indicator will flash green if the auxiliary input is closed the Door indicator will flash red ee A This mode takes control of the Door indicator LED The indicator LED will not be lit when Il 1 A valid code isentered 2 While in secure mode when waiting fora secondary code AUXILIARY MODE 9 Auxiliary input function Red LED control Auxiliary output activated by Valid user code Auxiliary code Eg In auxiliary mode 9 the controllercan function asa two door controller and also provide indicator functionality control The auxiliary relay is connected to the lock on the second door The auxiliary setting definesthe door open time forthe second door The auxiliary input is used to control the indicator If the auxiliary input is open the Door indicator will flash red if the auxiliary input is closed the Door indicator will flash green This mode takes control of the Door indicator LED The indicator LED will not be lit when 1 A valid code is e
2. Orange Green Page 31 AC Q4x Family Installation and user Manual Programming 3 Hereafter are four different waysto program the nomal bypasscode and doorchime a Disable both Bypass Code and the doorchime Enter the code 0000 b Disable BypassCode and enable the doorchime Enter the code 0001 c Enable BypassCode and disable the doorchime Enter any code ending with 0 d Enable BypassCode and enable the allello a doorchime a Entera code not ending with 0 4 System retumsto its normal mode e You will hearthree beeps e The Doorindicator will tum off Mode Door e The Mode indicator will tum green Green 4 77 SETTING FAILSAFE SECURE OPERATION In this paragraph the failsafe fail secure operation of the door lock and the door lock strike release time are set Setting the sounding period forthe siren feature requires a BL D40 Extemal Sounder Mode Door 1 Enterthe programming mode Greek 2 Depress6 to enter Menu 6 Mode aS Door e The Mode indicator will flash green Green Green AC Q4x Family Installation and user Manual Page 32 Programming 3 Construct a code using instructions hereafter First Digit For fail secure operation the first digit is set to 0 For failsafe operation the first digit is set to 1 Second Digit Siren time enterany number from 0 to 9 minutes Third and Fourth Digits The Lock S
3. 25802580 29 2 Change auxiliary code 0852 08520 085208 08520852 29 3 Change program code 1234 12341 123412 12341234 30 4 Change nomal secure code 3838 38383 383838 38383838 31 5 Change nomal bypasscode 31 6 Change door release time 0004 32 6 Define auxiliary inputs outputs 2004 33 6 Enable ordisable keypad 3000 41 heater 6 Set Lockout Feature 4000 41 7 Enroll proximity cards PIN or 42 both 8 Delete proximity cards or PIN 46 9 Code assignment with 48 strike auxiliary 0 Retum to factory defaults 50 Change PIN code Length Table 1 programming Menu Page 27 AC Q4x Family Installation and user Manual Programming 4 1 1 Entering the Programming Mode r E e The controller must be in nomal mode to enter the programming mode e The factory default 4 digit programming code is 1234 e Ifa programming code isnot entered within 5 seconds the controller will retum to its normal mode 1 Depressthe key twice within 0 5 seconds e Mode indicator will tum off Mode Door e Doorindicator will tum red Red 2 Enteryour programming code If the programming code is valid the door Mode Door Indicator will tum green and the controller will Green enterthe programming mode 4 1 2 Exiting the Programming Mode r E A e Wrong entries may reset the controller back to its nomal mode I e fno key is pressed for 1 minute while in programming mode the controller will exit the progra
4. AC FROM TRANSFORMER AUXILIARY LOAD Transorb type 1 5KE47C optional for inductive loads not supplied Figure 4 Pre Wired Connection for Auxiliary Input amp Output Page 13 AC Q4x Family Installation and user Manual Installation CONTROLLER BLACK UNIT GROUND BL D40 Figure 5 Pre Wired Connection for the BL D40 External Sounder AC Q4x Family Installation and user Manual Page 14 Installation 2 2 2 Terminal Block Models These controllers come with removable terminal blocks that are pushed on pinson the motherboard of the controllers Wire according to the following steps 1 Route the wiresorcable through the large hole in the back cover See Figure 6 Connect the terminal blocks as shown 2 Wire the cabling according to the following diagrams Wiring the Lock Strike Relay amp REX Figure 7 Wiring for Auxiliary Input amp Output Figure 8 Wiring forthe BL D40 Extemal Sounder Figure 9 Push the terminal blocks onto the controllers connector pins Figure 6 Connections to Terminal Blocks Page 15 AC Q4x Family Installation and user Manual Installation Controller ELECTRIC LOCK STRIKE COMMON POWER SUPPLY 12V 24V DC or 16V 24V AC ROM TRANSFORMER FAIL SAFE or FAIL SECURE Transorb 1 5KE47C connect to load optional not supplied Figure 7 Terminal Block Wiring of the Lock Strike Relay amp
5. KEY FEATURES 500 Users Water and vandal resistant Backlight Bac klit fa mily option B Three user levels normal secure master Three modes of operation nomal bypass secure Integrated keypad for PIN entry Piezo electric Q44 only Integrated proximity card reader Q42 and Q44 only Selectable PIN code length up to 8 digits Auxiliary input and auxiliary output Ten auxiliary modes including door ajar forced door shunt door monitor nomal secure LED control Input for Request to Exit REX button Code search feature for easy maintenance of usercodes Intemal buzzer Vandal proof screw special tool supplied Two tri color LED indicators for status programming Interface Built in case and back tamper protection Lockout feature on wrong entries Keypad Card Tamper Bell chime siren and strobe features available with BL D40 Programmable siren time with BL D40 Programmable lock strike release time Supplied with mounting template for easy installation Page 7 AC Q4x Family Installation and user Manual General Information 1 7 FRONT PANEL DESCRIPTION Controls and indicators of all controller versions are identical See Figure 1 excluding the antenna which is unique to Q42 and Q44 Mode Door Indicator Indicator Antenna AC Q42 amp AC Q44 only Bell Button t ia Case Screw Figure 1 Front Panel AC Q4x Family Installation and user Manual Page 8 Installation 2 Installation 2 1
6. and or by presenting a proximity card 1 2 CONTROLLER TYPES The different types of control units described in this manual are e Type 41 is PIN only e Type 42 is PIN and proximity card e Type 44is PIN and proximity card with Piezo contacts Heater Relay Backlight Keypad Proximity Curent Type AC Q41H va 3A x Standard x AC Q41HB vA 3A va Standard x AC Q41S s 2A x Standard x AC Q41SB va 2A wa Standard x AC Q42H va 3A x Standard va AC Q42HB v 3A s Standard va AC Q42S va 2A x Standard lt s AC Q42SB s 2A va Standard vA AC Q44 x 3A x Piezo lt s AC Q4x Family Installation and user Manual Page 4 General Information 1 3 BOX CONTENT Before beginning venfy that all of the following isin the box if anything is missing please report the discrepancy to your nearest Rosslare Office 1 4 One unit One Drilling Template Label Sticker One security spline key One security hex screw Fourmounting screwsand wall plugs ANCILLARY EQUIPMENT The following ancillary equipment may be required to complete your installation Electric Lock Strike Mechanism fail safe power to lock or fail secure powerto open Power Supply with Backup Battery 12 to 24 VDC froma regulated power supply or 16 to 24 VAC froma transformer Request to Exit REX Button optional normally open type switch is closed when pressed BL D40 Extema l Sounder optional provides
7. configured in ten different modes of operation Referto Setting the Auxiliary Mode on paragraph 4 8 3 4 2 Request to Exit Button REX The REX pushbutton islocated within the premises and is used to open the door from the inside It is usually located ina convenient location e g next to the doororata receptionist s desk The doorchime if enabled in the BL D40 does not sound when the REX pushbutton is used to open the door The function of the REX pushbutton dependson the Lock Strike relay whether it is programmed for failsafe or for fail sec ure operation Fail Secure Operation from the moment the REX pushbutton is depressed the doorwill be unlocked until the Lock Strike release Page 23 AC Q4x Family Installation and user Manual Operation time has elapsed After this time the door will be locked even if the REX pushbutton has not been released Failsafe Operation from the moment the REX pushbutton is depressed the doorwill be unlocked until the REX pushbutton is released In this case the Lock Strike relay only begins its countdown once the REX pushbutton has been released This feature isdesigned to keep the dooropen when used in conjunction with fire systems 3 4 3 Tamper Feature In case the controller is forcibly opened or the controller is removed from the wall a tamper event is triggered A tamper signal is sent to the BL D40 If the BL D40 Extemal Sounder receivesa tamper event signal it will activ
8. mail support apac rosslaresecurity com United States and Canada 1600 Hart Court Suite 103 Southlake TX USA 76092 Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 E mail sup port na rossla resec urity com Europe Global Technical Support amp Training Center HaMelecha 22 Rosh HaAyin Israel 48091 Tel 972 3 938 6838 Fax 972 3 938 6830 E mail support eu rosslaresec urity com South America Pringles 868 1640 Martinez Buenos Aires Argentina Tel 54 11 4798 0095 Fax 54 11 4798 2228 Web Site www rossiaresec urity com Page 55 AC Q4x Family Installation and user Manual SECURITY PRODUCTS WWW ROSSLARESECURITY COM CE 0706 0960121 01
9. siren bell and chime Magnetic Contact optional installed for door monitor capabilities Page 5 AC Q4x Family Installation and user Manual General Information 15 TECHNICAL SPECIFICATIONS AC Q41H AC Q4IHBJAC Q42H AC Q42HBIAC Q415 AC Q41B AC Q42S AC qa2sac Q44 Input Voltage VDC 12 24 VDC VAC 12 24 VAC 16 24 VAC 12 24 VAC 16 24 VAC Maximum Input Heater Off 100mA 130mA 125mA 145mA 100mA 130mA 125mA 145mA 125mA Current 12VDC HeaterOn 580mA 610mA 605mA 625mA 580mA 610mA 605mA 625mA N A Standby Input Heater Off 40mA 70MA 65mA 85mA 40mA 70MA 65MA 85mA 65mA Curent 12VDC HeaterOn 520mA 550mA 545mA 565mA 520mA 550mA 545mA 565mA N A Maximum Relay Current 3A 2A 3A REX Input Normally Open Dry Contact Aux Input Normally Open Dry Contact Max Proximity read range N A 65 mm 2 5 N A 65 mm 2 5 Proximity Modulation N A ASK at 125 KHz N A ASK at 125 KHz Proximity card compatibility N A 26 Bits EM cards N A 26 Bits EM cards LED Indicators Two 3 colored LED Mode and Door Operating Temperatures 20 C to 60 C 4 F to 140 F Outdoor Usage Water resistant meets IP 54 Weather resistant meets IP 65 Epoxy potted Size H120xW 76xT27mm_ H4 72 xW 3 xT1 06 H120xW 76xT22mm_ H 4 72 x W 3 xT0 85 Weight 440gr 1lbs 521 gr 1 18 Ibs AC Q4x Family Installation and user Manual Page 6 General Information j 6
10. 5 enter either 00012345 or 12345 e Both the Mode and Doorindicators Mode y 6 Door will flash red Red Red 3 Enteryour programming code If the programming code is valid all memory will be erased you will hear three beepsand the controller will retum to normal mode If the programming code is invalid you will heara long beep and the controller will retum to nomal mode without erasing the memory contents AC Q4x Family Installation and user Manual Page 50 Programming 4 15 REPLACING A PROGRAMMING CODE f A The controller must be in its normal mode forthe procedure fl to work Insure that the Mode indicator is green before proceeding 1 Remove power from the controller 2 Depressand hold the REX pushbutton 3 Apply powerto the unit with the REX pushbutton depressed 4 Release the REX pushbutton 5 Younow have 15 secondsto program a new programming code into the unit using the initial default code before the controller reverts to the existing code the deafult code depends on the pin length selected reffer to the programming Menu table on page 27 4 16 REPLACING A NORMAL SECURE CODE A e The controller must be in its secure mode forthe procedure fl to work Insure that the Mode indicatorisred before proceeding 1 Remove power from the controller 2 Depressand hold the REX pushbutton 3 Apply powerto the unit with the REX pushbutton depressed 4 Release the REX pushbutton 5 You now have 15 s
11. AC Q4x Family Vandal Resistant Stand Alone controllers Instruction Manual Models AC Q41H HB AC Q41S SB AC Q42H HB AC Q42S SB AC Q44 January 2006 ROSSLNR SECURITY PRODUCTS Table of Contents Table of Contents General Information 1 1 INTRODUCTION 1 2 CONTROLLER TYPES 1 3 BOX CONTENT 1 4 ANCILLARY EQUIPMENT 1 5 TECHNICAL SPECIFICATIONS 1 6 KEY FEATURES 1 7 FRONT PANEL DESCRIPTION Installation di 2 1 MOUNTING THE CONTROLLER 2 2 WIRING THE CONTROLLER 2 2 1 Pre wired Models 2 2 2 Terminal Block Mode 3 1 MODES OF OPERATION 3 1 1 Normal Mode Default 3 1 2 Secure Mode 3 1 3 Bypass Mode 3 2 USERLEVELS 3 2 1 Normal User 3 2 2 Secure User 3 2 3 Master User 3 3 SWITCHING OPERATIONAL MODES 3 3 1 From Normal to Secure Mode 3 3 2 From Secure to Normal Mode 3 3 3 From Normal to Bypass Mode 3 3 4 From Bypass to Normal Mode 3 4 SPECIAL OPERATIONAL FEATURES 3 4 1 Auxiliary Input amp Output 3 4 2 Request to Exit Button REX 3 4 3 Tamper Feature 3 44 Lockout Feature Keypad Card Tamper 3 4 5 BL D40 External Sounder AC Q4x Family Installation and user Manual Page ii Table of Contents 4 1 4 1 1 4 1 2 4 2 43 4 4 4 5 4 6 4 7 4 8 4 8 1 4 8 2 4 8 3 4 9 4 10 4 11 4 11 4 11 2 4 11 3 4 11 4 4 11 5 4 12 4 12 4 12 2 4 13 4 13 INTRODUCTION 26 Entering the Program
12. E AUXILIARY CODE The auxiliary code is mainly used asa method to quickly test the Auxiliary relay during installation The default 4 Digit factory setting forthe auxiliary code is 0852 For security reasons when the first user is added to the controller or the open code ischanged the default auxiliary code will automatically be deleted non default codes will not be erased automatically Page 29 AC Q4x Family Installation and user Manual Programming enU e Auxiliary code doesnot function in secure mode Il e Auxiliary code only works when the auxiliary mode isO 1 8 or 9 e Wrong entres you will heara long beep and the controller will retum to its nomal mode e Code 0000 will erase and deactivate the auxiliary code 1 Enterthe programming mode Moe Q Door 2 Depres2to enter Menu 2 Green e The Mode indicator willtum orange Mode Door 3 Entera new auxiliary code Orange Green 4 System retumsto its nomal mode e You will hearthree beeps e The Doorindicator will tum off Mode Q Door e The Mode indicator will tum green Green 4 4 CHANGING THE PROGRAMMING CODE r E e The code 0000 is not valid thus the programming code cannot I be erased e Wrong entres you will heara long beep and the controller will retum to its nomal mode 1 Enterthe programming mode Mode QO Poor Green 2 Depress 3to enter Menu 3 e The Mode indicator willtum green Mode Door 3 Enterthe new programming code
13. Greet Gree 4 System retumsto its normal mode e You willhearthree beeps Mode Door e The Door indicator will tum off ate G e The Mode indicator will tum green A AC Q4x Family Installation and user Manual Page 30 Programming 4 5 CHANGING THE NORMAL SECURE CODE e When the auxiliary mode is 1 2 3 or 4 the auxiliary input takes Il priority over the nomal secure code e Wrong entries you will heara long beep and the controller will retum to its nomal mode e Code 0000 will erase and deactivate the nomal secure code 1 Enterthe programming mode Mode Q Door Green 2 Depress4to enter Menu 4 e The Mode indicator will flash red Mode 3 Door 3 Enterthe new Nomal Secure code Red Green 4 System retumsto its normal mode e You will hearthree beeps Mode Door e The Doorindicator will tum off are G e The Mode indicator will tum green i 4 6 CHANGING THE NORMAL BYPASS CODE The nomal bypasscode is also used to tum the doorchime off and on Chime only functions with the BL D40 Exte mal Sounder r ww e The chime is only heard when the Lock Strike relay is activated I by a valid code entry e Wrong entries you will heara long beep and the controller will retum to its nomal mode e Code 0000 will erase and deactivate the nomal bypass code 1 Enterthe programming mode Mode Q Door Green 2 Depress5 to enterMenu 5 Mode xe Door e The Mode indicator will flash orange T
14. MOUNTING THE CONTROLLER Priorto starting select the location where the controller unit isto be mounted Perfom the following steps 1 Open the controller by loosening and removing the case security screw at the bottom using the security spline key 2 Depending on the type of installation gang box or panel mount drill the respective holes in the rearcover See Figure 2 for details For gang box mounting drill two holes marked A Forflat panel mount drill four holes marked B CAUTION DO NOT DRILL Tamper Lens Figure 2 Drilling Holes Identification SSS O A The central hole marked C is for routing the wiring to the Il controller Page 9 AC Q4x Family Installation and user Manual Installation 3 Use the provided drilling template to accurately locate and drill the required holes in the wall or panel 4 Use the hardware provided to mount the back plate on the wallorona gang box Be sure to route the wiring via the large center hole in the back plate Check for level 5 Wire the controlleraccording to the type supplied pre wired cable orterminal block terminal as instructed hereafter 6 Once wired replace the controller back onto its back plate and secure using tamper proof screw and special tool supplied with the hardware 2 2 WIRING THE CONTROLLER The controllers are provided either with a one meter pre wired 10 conductorcable orwith a screw type terminal block Spec
15. REX AC Q4x Family Installation and user Manual Page 16 Installation Controller Unit AUXILIARY COMMON INPUT POWER SUPPLY MONITOR 12V 24V DC or 16V 24V AC FROM TRANSFORMER AUXILIARY LOAD Transorb type 1 5KE47C optional for inductive loads not supplied Figure 8 Terminal Block Wiring of the Auxiliary Input amp Output Page 17 AC Q4x Family Installation and user Manual Installation Controller Unit COMMON POWER SUPPLY 12V 24V DC or 16V 24V AC FROM TRANSFORMER Figure 9 Terminal Block Wiring of the BL D40 External Sounder AC Q4x Family Installation and user Manual Page 18 Operation 3 Operation e Inthe Operation chapter code refers to a PIN code or proximity card depending on the unit you have e Memory dotscan be a proximity card or PIN code depending on the unit you have 3 1 MODES OF OPERATION The Control units have three modes of operation These are indicated by the colorof the Mode indicator 3 1 1 Normal Mode Default e Mode indicator is green In normal mode the dooris locked until a valid primary code is presented to the controller The controllercan only be programmed in nomal mode 3 1 2 Secure Mode e Mode indicatoris red Only secure and master users can access the premises in secure mode A secure user must entera primary and secondary code to gain entry Once the primary code has been entered the Door ind
16. an AC Q4x Family Installation and user Manual Page 20 Operation gain accessin any mode of operation In normal mode the secure user must use the primary code to gain entry In secure mode the secure user must first enter the primary and then the secondary code in orderto gain entry 3 2 3 Master User A master user must have identical primary and secondary codes assigned The codesare entered with the same proximity card or the same PIN The master user can gain access during any mode of operation by entering their code only once 3 3 SWITCHING OPERATIONAL MODES The three modes of operation defined above can be changed through a few steps 3 3 1 From Normal to Secure Mode The default factory setting forthe normal secure code is 3838 1 Enterthe nomal secure code Mode Q Door Green e Mode indicator will flash red Mode 3 O Door Red 2 Depressthe key to confirm the Mode cha nge Mode O Door e Mode indicatoris red Red The auxiliary input of the controllercan also be used to switch the mode of operation from secure to normal and vice versa if the auxiliary input is selected it de activates the Norma Secure mode code Referto Setting the Auxiliary Mode paragraph 4 8 3 3 2 From Secure to Normal Mode The default factory setting forthe normal secure code is 3838 Page 21 AC Q4x Family Installation and user Manual Operation 1 Enterthe nomal secure code Mode Door Red e Mode indicator will flash g
17. ate a tamper output and a strobe light The siren time can be easily programmed in the controller from 0 to 9 minutes The tamper event can activate the auxiliary output if the controlleris in Auxiliary Mode 3 Referto the Quick Reference Guide for Auxiliary Mode Setting table in paragraph 4 8 2 below 3 4 4 Lockout Feature Keypad Card Tamper In case the controlleris presented with wrong codes PIN orCard consecutively several times the unit goes into lockout mode When a lockout occurs the controller keypad and readerare de activated so no codescan be entered until the set lockout period expires During Lockout Mode LED is Off Door LED flashes Red and the controller beeps every two seconds AC Q4x Family Installation and user Manual Page 24 Operation Referto programming menu 6 fordetailed programming of this feature 3 4 5 BL D40 External Sounder The BL D40 Extemal Sounderis designed for indoor use only and installed within the secured premises The Sounder can be powered bya 12 to 24VDC power supply or bya 16VAC transformer The BL D40 is capable of emitting four different types of audible and visual alerts bell chime siren and strobe light e The bell sounds when the controller s bell button is depressed e The doorchime can be programmed to sound whenevera valid code isentered aswell asfora doorheld open alert e The siren can be programmed to sound when the controller is tampered with opened orremoved fro
18. ccepta primary code b Ifthe selected slot already hasa primary code but no secondary code the Mode Mode X Door indicator will flash red indicating Red Orange that the controlleris ready to accepta secondary code c Ifthe selected slot already hasa primary and secondary code a long beep will be heard and the controller will retum to its nomal mode 5 Enterthe code to be assigned asthe primary orsecondary code for this slot number If the code that is entered is valid the Mode indicator will cease flashing and the controller is ready forthe next 3 digit slot number step 3 ordepressthe key to move to the next slot number step 4 If you do not wish to continue enrolling codes depress the key twice and the controller will retum to itsnormal mode AC Q4x Family Installation and user Manual Page 44 Programming 4 11 5 Search Method for Codes Enrolling The code search method enables to quickly enroll a secondary code fora user whose primary code is known and whose slot number is unknown Mode O Door 1 Enterthe programming mode Crean 2 Depress7 to enterMenu 7 Aica D e The Doorindicatorwilltum orange M O Por Orange 3 Enterthe 3 digit user slot number 000 e The Doorindic ator will flash orange The controller isnow waiting forthe Mode Bom Door primary code of the user Orange 4 Enterthe primary code belonging to the user who needsa secondary code A A e The Mode indicator will flash red Mo
19. de 3 3f Door If the primary code entered is not Red Orange valid a long beep will sound and the controller will wait fora valid primary code 5 Enterthe code to be used asthe secondary code If the secondary code is valid the controller will beep three times and retum to its normal mode If the secondary code is invalid the controller will produce a long beep and will wait fora valid secondary code to be entered Page 45 AC Q4x Family Installation and user Manual Programming 412 DELETING CODES There are two methodsto delete primary and secondary codes a standard method and a search method When deleting a user slot both the primary code and the secondary code are erased are Bo Nols a eee O A It is recommended thata record be kept of added and deleted users This makes it easier to keep track of user sots status Il empty or not 4 12 1 Standard Method for Deleting Codes 1 Enterthe programming mode Mode Door Green 2 Depress8 to enter Menu 8 Mode Door e The Mode indicator will tum red Red Orange 3 Enterthe 3 digit user slot code to be deleted PRISE The Mode indicator will flash red Moie Door indic ating the controller is waiting for ays Red Orange a programming code to confirm the deletion If the user dot is empty a long beep will be heard and the controller will retum to its normal mode 4 Enteryour programming code to confirm the deletion If the programmi
20. descannot be the same asany system codes such as the normal secure code orthe open code e Users possessing secondary codescan gain entry in any mode of operation e A Secondary code can be the same asthe primary code of any user 4 11 3 Primary and Secondary Codes Enrolling Methods There are two methods used to enroll primary and secondary codes the standard method and the code search method 1 The standard method is used when the user slot number for the user you wish to program is known You can program both primary and secondary codesusing this method 2 The code search method is mainly used when enrolling a secondary code and the user sslot code is unknown The code search method will function only if a user s primary code isalready enrolled and the secondary code isnot Page 43 AC Q4x Family Installation and user Manual Programming 4 11 4 Standard Method for Codes Enrolling 1 Enterthe programming mode Mode Door Green 2 Depress 7 to enterMenu 7 e The Doorindicator willtum orange Mode Door Orange 3 Enterthe 3 digit user slot number into the memory PIESE from 001 to 500 so asto enrolla primary or secondary code Forexample the user slot 003 represents user no 3 4 Atthistime three possibilities exist a Ifthe selected slot hasno primary code the Mode indicator will flash green indicating oe that the controller is ready to Mode ae eee Green Orange a
21. econdsto use the normal secure code to retum to the nomal mode Once in the normal mode enter the programming mode to programa new nomal secure code the deafult code depends on the pin length selected reffer to the programming Menu table on page 27 Page 51 AC Q4x Family Installation and user Manual Programming AC Q4x Family Installation and user Manual Page 52 Limited Warranty Appendix A Limited Warranty ROSSLARE ENTERPRISES LIMITED S Rosslare TWO YEARS LIMITED WARRANTY is applicable worldwide This warranty supersedes any other warranty Rosslare s TWO YEARS LIMITED WARRANTY is subject to the following conditions Warranty Warranty of Rosslare s products extends to the original purchaser Customer of the Rosslare product and is not transferable Products Covered By This Warranty and Duration ROSSLARE ENTERPRISES LTD AND ORSUBSIDIARIES ROSSLARE warrants that the AC Qx metal stand alone controller family as listed above to be free from defects in materials and assembly in the course of normal use and service The warranty period commences with the date of shipment to the original purchaser and extends for a period of 2 years 24 Months Warranty Remedy Coverage n the event of a breach of warranty ROSSLARE will credit Customer with the price of the Product paid by Customer provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of
22. ecure modes Auxiliary output activated by direct shunt explanation below E g In auxiliary mode 4 the controller is capable of bypassing an alam zone by shunting an alam system s door sensor The auxiliary output is to be wired in parallel to the doorsensor output When in use the auxiliary output is normally open and the door sensor functions no mally When a valid code is entered the auxiliary relay shuntsthe door sensor forthe duration of the shunt time as defined by the auxiliary setting If the dooris left open longerthan the shunt time an alam will be triggered AUXILIARY MODE 5 Auxiliary input function Door Monitor Auxiliary output activated by Shunt explanation below E g In auxiliary mode 5 the controller is capable of shunting an alam system In this mode the auxiliary input is to be wired to the magnetic contact switch on the door The auxiliary relay is wired to the alam system Without a valid code entered the auxiliary relay will match the condition of the magnetic contact switch if the dooropens the auxiliary relay will open if the doorcloses the auxiliary relay will close When a valid code isentered a count down for maximum shunt time as defined by the auxiliary setting begins if the dooris not closed before the maximum shunt time the alam will be triggered AC Q4x Family Installation and user Manual Page 38 Programming AUXILIARY MODE 6 Auxiliary input function Door Monitor Auxiliary output ac
23. ffice hours to secure mode after office hours AC Q4x Family Installation and user Manual Page 36 Programming AUXILIARY MODE 2 Auxiliary input function Toggles nomal secure modes Auxiliary output activated by Star Button E g In auxiliary mode 2 the auxiliary relay can function asa general purpose time switch that can be activated when the star button is depressed The auxiliary setting establishes for how long the auxiliary relay isto be activated The auxiliary input can switch the mode of operation of the controller between nomal and secure mode By connecting a switch timer or alarm system output to the auxiliary input the controller can be automatically switched from nomal mode during office hours to secure mode after office hours AUXILIARY MODE 3 Auxiliary input function Toggles nomal secure modes Auxiliary output activated by Alarms E g In auxiliary mode 3 the auxiliary output is activated if the controller is tampered that is if the case is forcibly opened or removed from the wall The auxiliary input can switch the mode of operation of the controller between nomal and secure mode By connecting a switch timer or alam system output to the auxiliary input the controller can be automatic ally switched from nomal mode during office hours to secure mode after office hours Page 37 AC Q4x Family Installation and user Manual Programming AUXILIARY MODE 4 Auxiliary input function Toggles nomal s
24. here are two methods to assign relay codesto users a standard method and a search method 4 13 1 Relay Code Assignment using Standard Method 1 Enterthe programming mode Mode Q Door Green 2 Depress 9 to enterMenu 9 e The Mode indicatorwilltum green Mode Door e The Doorindicator will tum orange Green Orange 3 Enterthe 3 digit user slot for code assignment PIES ers n Mode 3 O Door e The Door indicator will flash green ce sreen Orange 4 Enterthe assignment digit forthe current user dot e 1will activate the Lock Strike relay only deafult e 2will activate the Auxiliary relay only e 3will activate the Lock Strike and Auxiliary relays If the assignment code is valid the Mode Mode Door indicator will stop flashing Green Orange The controller is now waiting foranother slot number Depress the key to move to the next slot or enter a new slot number If you do not wish to continue depress the key twice and the controller will retum to its normal mode AC Q4x Family Installation and user Manual Page 48 Programming 4 13 2 Relay Code Assignment using Search Method 1 Enterthe programming mode Mode Door 2 Depress9 to enterMenu 9 Green e The Mode indicatorwilltum green Mode Door e The Doorindicator will tum orange Green Orange 3 Enter 000 for user slot access ollollo Mode a gt Door e The Doorindicator will flash orange bolt ae The c
25. icator will flash green for 10 seconds During thistime the secondary code must be entered A master user only needs to enter his code to gain entry Page 19 AC Q4x Family Installation and user Manual Operation 3 1 3 Bypass Mode e Mode indicatoris orange In bypass mode access to the premisesis dependent on the Lock Strike relays that is if the relay is programmed for failsafe operation or fail secure operation When the Lock Strike relay is programmed for fail secure operation the doorislocked until the star button is depressed When the Lock Strike relay is programmed for failsafe operation the dooris constantly unlocked In case of power failure once the poweris restored the controller will retum to nomal mode for security reasons 3 2 USER LEVELS AC Q4x series Access Control units accept up to 500 users and provide entry via the use of codes Each user is allocated two memory slots Memory Slot 1 primary code and Memory Slot 2 secondary code The way in which the two memory Slots are programmed determinesa usersaccess level and also establishes access is granted foreach of the three modes of operation There are three user levels 3 2 1 Normal User A nomal user only hasa primary code and isgranted access only when the controlleris in its normal or bypass mode 3 2 2 Secure User A secure user must have a primary and secondary code assigned and the two codes must not be the same The secure userc
26. ifically Pre wired cabling Models Terminal block models AC Q41S SB AC Q41H HB AC Q42S SB AC Q42H HB AC Q44 2 2 1 Pre wired Models These controllers come with 18 AWG wiring Wire according to the following steps 1 Cutand strip the conductors to the necessary length 2 Splice the controller pigtail wires to the corresponding ancillary devicesand insulate each connection including unused wires Referto the wiring color guide table below and to the wiring diagrams depending on the desired application Wiring the Lock Strike Relay amp REX Figure 3 Wiring for Auxiliary Input amp Output Figure 4 Wiring forthe BL D40 Extemal Sounder Figure 5 AC Q4x Family Installation and user Manual Page 10 Installation Wiring Color Guide Color Description Red V input Black Ground Green REX BL White In Monitor Purple Lock Com Gray Lock N O Brown Lock N C Blue Aux Com Yellow Aux N O Orange Aux N C Page 11 AC Q4x Family Installation and user Manual Installation ay Controller GROUND Unit VIN REX BL ELECTRIC LOCK STRIKE FAIL SAFE or 16V 24V AC FAIL SECURE FROM TRANSFORMER Transorb 1 5KE47C connect to load Optional not supplied Figure 3 Pre Wired Connection for Lock Strike Relay amp REX AC Q4x Family Installation and user Manual Page 12 Installation Controller Unit aux GROUND VIN COMMON POWER SUPPLY 12V 24V DC or 16V 24V
27. le Page 35 AC Q4x Family Installation and user Manual Programming 4 8 3 Detailed Reference Guide The following are bref descriptions of each auxiliary mode To implement the features of each mode refer to Setting the Auxiliary Mode paragraph 4 8 1 AUXILIARY MODE 0 Auxiliary input function Activates the auxiliary output Auxiliary output activated by Valid user code Auxiliary code Auxiliary input E g In auxiliary mode 0 the controller can function asa two door controller The auxiliary relay isto be attached to the lock on the second door The auxiliary setting defines the door open time for the second door The auxiliary input isto be attached to the REX pushbutton forthe second door Door Monitor input feature for the second doorisnot enabled when using this mode AUXILIARY MODE 1 Auxiliary input function Toggles nomal secure modes Auxiliary output activated by Valid usercode Auxiliary code E g In auxiliary mode 1 the controller can function asa two door controller The auxiliary relay isto be attached to the lock on the second door REX feature forthe second dooris not enabled when using this mode The auxiliary setting defines the door open time for the second door The auxiliary input can switch the mode of operation of the controller between nomal and secure mode By connecting a switch timer or alarm system output to the auxiliary input the controller can be automatically switched from nomal mode during o
28. le for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE which is attached to or used in conjunction with a Product nor to any Product that is used with any ancillary equipment which is not furnished by ROSSLARE This warranty does not cover expenses incurred in the transportation freight cost to the repair center removal or reinstallation of the product whether or not proven defective Specifically excluded from this warranty are any failures resulting from Customer s improper testing operation installation or damage resulting from use of the Product in other than its normal and customary manner or any maintenance modification alteration or adjustment or any type of abuse neglect accident misuse improper operation normal wear defects or damage due to lightning or other electrical discharge This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument or any modification or abuse of or tampering with the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim ROSSLARE does not warrant the installation maintenance or service of the Product Service life of the product is dependent upon the care it receives and
29. m the wall The length of the siren can also be programmed in the controller The controller communicates with the BL D40 via a Rosslare proprietary protocol If the BL D40 receives an unrecognized code over its communication line or communications between the controllerand the BL D40 are severed the strobe will flash repeatedly until the communication problem has been resolved Page 25 AC Q4x Family Installation and user Manual Programming 4 Programming e Inthe Programming chapter code refersto a PIN code or proximity card depending on the unit you have e When entering a PIN or presenting a proximity card is mentioned the meaning may vary between units 4 1 INTRODUCTION Programming an AC Q4x series Access Control unit is done solely via the unit s keypad driven Programming Menu System To reach the Programming Menu System the controller must first be placed into Programming Mode Referto Entering Programming Mode paragraph 4 1 1 During the manufacturing process certain codesand settings are pre programmed These settingsare the called default factory settings AC Q4x Family Installation and user Manual Page 26 Programming The Programming menu table below shows the names of all programming menus with default factory codesand settings Menu Description Default Page No 4 Digit 5 Digit 6 Digit 4 8 Digits No 1 Change open code 2580 25802 258025
30. ming Mode we 28 Exiting the Programming Mode 2 28 CHANGING THE OPEN CODE e529 CHANGING THE AUXILIARY CODE CHANGING THE PROGRAMMING CODE CHANGING THE NORMAL SECURE CODE CHANGING THE NORMAL BYPASS CODE SETTING FAILSAFE SECURE OPERATION SETTING AUXILIARY MODES G n ral ancen eiry tients Quick Reference Guide for Auxiliary Mode Setting Detailed Reference Guide KEYPAD HEATER OPERATION SETTING THE LOCKOUT FEATURE ENROLLING CODES Primary Codes Definition Secondary Codes Definition Primary and Secondary Codes Enrolling Methods Standard Method for Codes Enrolling Search Method for Codes Enrolling DELETING CODES Standard Method for Deleting Codes Search Method for Deleting Codes RELAY CODES ASSIGNMENT Relay Code Assignment using Standard Method Appendix A Limited Wananty Appendix B Technical Suppotrt Page iii 4 13 2 Relay Code Assignment using Search Method 4 14 PIN CODE LENGTH FACTORY DEFAULT SETTINGS 4 15 REPLACING A PROGRAMMING CODE 4 16 REPLACING A NORMAL SECURE CODE AC Q4x Family Installation and userManual General Information 1 General Information 1 1 INTRODUCTION The AC Q 4x series Access Control units are vandal resistant sand alone controllers All the units are water resistant and suitable for indooror outdoor mounting The unit s accepts up to 500 users and allowsentry via a personal identification number PIN
31. mming mode and retum to its nomal mode To exit the programming mode depress the key twice within 0 5 seconds e You willhearthree beeps e The door indicator will be off e The mode indicator will tum green Mode O Door Green The above indicates that the controller has retumed to its nomal mode nnu A While enrolling deleting users or while in code assignment mode depressthe key twice to exit the programming mode AC Q4x Family Installation and user Manual Page 28 Programming 4 2 CHANGING THE OPEN CODE The open code is mainly used asa method to quickly test the Lock Strike relay during installation The factory 4 digit default setting for the open code is 2580 For security reasons when the first user is added to the controller or the auxiliary code ischanged the default open code will automatically be deleted non default codes will not be erased automatically nuU e Open code doesnot function in secure mode fl e Wrong entres you will heara long beep and the controller will retum to its nomal mode e Code 0000 will erase and deactivate the open code 1 Enterthe programming mode 2 Depress1to enter Menu 1 Mode Door e The Mode indicator will tum red Red Green 3 Enterthe new code you wish to set asopen code 4 System retumsto its normal mode e You will hearthree beeps e The Doorindicator will tum off Mode Q Door The Mode indicator will tum green Green 43 CHANGING TH
32. ng code is valid three beeps will be heard and the controller will retum to its normal mode If the programming code is invalid a long beep will be heard and the controller will retum to its normal mode AC Q4x Family Installation and user Manual Page 46 Programming 4 12 2 Search Method for Deleting Codes 1 Enterthe programming mode Mode Door Green 2 Press8to enterMenu 8 Mode Door e The Mode indicator will tum red Red Orange 3 Enter 000 for user slot ollollo e The Doorindicator will flash orange The controller isnow waiting forthe Mode Of Door primary code of the userto be Red Orange deleted 4 Enterthe primary code to be deleted Mode 3 Jp Door e The Mode indicator will flash red Red Orange 5 Enter your programming code to confirm the deletion If the programming code is valid three beeps will be heard and the controller will retum to its normal mode If the programming code is invalid a long beep will be heard and the controller will retum to its normal mode Page 47 AC Q4x Family Installation and user Manual Programming 4 13 RELAY CODES ASSIGNMENT When a primary code isenrolled for any user the useris authorized to activate the Lock Strike relay However different user codes may be set to operate the auxiliary relay instead or operate both the Lock strike and auxiliary relay Assignment of such codesis achievable for any valid usercode entered in the controller T
33. ntered 2 While in secure mode when waiting fora secondary code AC Q4x Family Installation and user Manual Page 40 Programming 49 KEYPAD HEATER OPERATION DO APPLICABLE TO H VERSIONS ONLY with keypad heater The Hversions of the controller contains a built in keypad heater Once the heater circuitry is activated the heater will tum on when the ambient temperature dropsto 441 C and will remain on until the keypad temperature risesto 7 2 or 1 C When the heaterison the controllercan operate down to an ambient temperature of 20 C When the heateris disabled the lowest operating temperature is 0 C The default setting for the keypad heateris disabled state 3000 1 Enterthe programming mode 2 Depress6 to enter Menu 6 Mode us Door e The Mode indicator will flash green Green Green 3 Constructa code using the following instructions To disable the heater the fourth digit is set to 0 To enable the heater the fourth digit isset to 1 410 SETTING THE LOCKOUT FEATURE In case the controlleris presented with wrong codes PIN orCard consecutively several times the unit goes into lockout mode When a lockout occurs the controllerkeypad and readerare locked so no codescan be entered until the set lockout period expires During Lockout Mode LED is Off Door LED flashes Red and the controller beeps every two seconds Page 41 AC Q4x Family Installation and user Manual Prog
34. ontroller is now waiting forthe primary code of the user 4 Enterthe primary code belonging to the user e The Mode indicator will flash green A A Mode ye Door w w Green Orange 5 Enterthe assignment digit for the current user slot e 1will activate the Lock Strike relay only deafult e 2will activate the Auxiliary relay only e 3will activate the Lock Strike and Auxiliary relays If the assignment digit is valid three beepswill be heard and the controller will retum to its nomal mode If the assignment digit is invalid a long beep will sound and the controller will wait for another assignment digit to be entered Page 49 AC Q4x Family Installation and user Manual Programming 4 14 PIN CODE LENGTH FACTORY DEFAULT SETTINGS A You must be very careful before using this command Changing the pin code length will also erase the entire memory contents including all userand special codes and retum all codes to their factory default settings 1 Enterthe programming mode Mode O Door Green 2 Selectthe desired pin code length as followes a 00 Retumsto factury defaults and setsa 4 digit code b 05 Retumsto factury defaults and setsa 5 digit code c 06 Retumsto factury defaults and setsa 6 digit code d 08 Retumsto factury defaults and setsa 4 8 digit code When choosing the 4 8 option please note that you should either enter zeros before the code or press pound at the end for example if your code is 1234
35. ra more detailed explanation on each auxiliary mode referto the Auxiliary Mode Reference table below Auxiliary Settings Each of the auxiliary modes hasa two digit setting which affects the operation of the related relay s 4 System retumsto its normal mode Mode Q Door e You will hearthree beeps Green e The Doorindicator will tum off The Mode indicator will tum green AC Q4x Family Installation and user Manual Page 34 Programming 4 8 2 Quick Reference Guide for Auxiliary Mode Setting Auxiliary Auxiliary Input Auxiliary Auxiliary Auxiliary Settings Mode Function Output Relay in seconds Activated by 0 AUX REX Valid code or N O 01 to 99 Aux relay release time AUX REX 00 Aux relay toggle 1 Nommal Secure Valid code N O 01 to 99 Aux relay release time switch 00 Aux relay toggle 2 Nomal Secure Star button N O 01 to 99 Aux relay release time switch 00 Aux relay toggle 3 Nommal Secure Tamperevent N C 01 to 99 Aux relay release time switch 00 Aux relay tamperactivated 4 Norma VSecure Direct shunt N O 01 to 99 Shunt time switch 5 Door Monitor Shunt N C 01 to 99 Maximum shunt time 6 Door Monitor Forced door N C 01 to 99 Forced delay 7 Door Monitor Doorajar N C Olto 99 Ajardelay 8 LED control Valid code N O 01 to 99 Aux relay release time Green 00 Aux relay toggle 9 LED control Red Valid code N O 01 to 99 Aux relay release time 00 Aux relay togg
36. ramming The default setting for the Lockout Feature is 4000 Lockout Disabled awe Qn SS A Using the lockout feature is highly recommended especially when selecting to use short PIN code length 4 or 5 digits 1 Enterthe programming mode A 2 Depress 6 to enter Menu 6 Mode 38 Door e The Mode indicator will flash green Green Green 3 Construct a code using the following alll instructions Set the numberof wrong code attempts which will cause Lockout between 0 and 9 attempts Sets the Duration of the lockout between 00 and 99 the value is multiplied by ten resulting in 0 990 seconds 4 11 ENROLLING CODES 4 11 1 Primary Codes Definition e Primary codescan only be enrolled to an empty user slot a slot with no existing primary code in the controllers memory e A primary code must be unique for instance one users primary code may not be the same as that of another user e Primary codescannot be the same as system codes such as the normal secure code orthe open code e Users possessing a primary code can gain entry during nomaland bypass modes AC Q4x Family Installation and user Manual Page 42 Programming 4 11 2 Secondary Codes Definition e Secondary codescan only be enrolled to a user sot that already includesa primary code e A Secondary code need not be unique for instance one users Secondary code may be the same as that of another user e Secondary co
37. reen Mode Yay D ode X O oor Green 2 Depressthe key to confim the Mode Mode O Door change e Mode indicator will tum green Green The auxiliary input of the controllercan also be used to switch the mode of operation from secure to normal and vice versa if the auxiliary input is selected it de activates the Norma Secure mode code Referto Setting the Auxiliary Mode paragraph 4 8 3 3 3 From Normal to Bypass Mode By default there isno normal bypasscode The nomal bypass code must first be programmed to use this function Refer to paragraph 4 6 to create modify the normal bypasscode 1 Enterthe normal bypasscode Mode Door Green e Mode indicator will flash orange Mode 34 CO Door Orange 2 pea key to confirm the mode Mode Door e Mode indicator will tum orange Orange 3 3 4 From Bypass to Normal Mode 1 Enterthe normal bypasscode Mode Q Door Orange A AC Q4x Family Installation and user Manual Mode 3 Cpdge 22 v Green Operation e Mode indicator will flash green 2 Depressthe key to confirm the mode change e Mode indicator will tum green Mode Door Green 3 4 SPECIAL OPERATIONAL FEATURES Some installation specific features are exercised as required by the system These features are implemented asshown in Figures 4 thru 9 3 4 1 Auxiliary Input amp Output For optimum usability in different applications the controller s auxiliary input and output can be
38. the conditions under which it has to operate In no event shall Rosslare be liable for incidental or consequential damages Limited Warranty Terms THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD AND IT S SUBSIDIARIES S WARRANTY THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON WHETHER OR NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE SPECIFICALLY EXCLUDED IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT OR FOR ANY OTHER INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF USE LOSS OF TIME COMMERCIAL LOSS INCONVENIENCE AND LOSS OF PROFITS ARISING OUT OF THE INSTALLATION USE OR INABILITY TO USE SUCH PRODUCT TO THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE DISCLAIMED BY LAW THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE PROVISIONS OF THIS LIMITED WARRANTY AC Q4x Family Installation and user Manual Page 54 Technical Support Appendix B Technical Support Asia Pacific Middle East Africa Rosslare Security Products Headquarters 905 912 Wing Fat Industrial Bldg 12 Wang Tai Road Kowloon Bay Hong Kong Tel 852 2795 5630 Fax 852 2795 1508 E
39. this warranty Unless otherwise requested by ROSSLARE ENTERPRISES LTD AND OR SUBSIDIARIES representative return of the failed product s is not immediately required f ROSSLARE has not contacted the Customer within a sixty 60 day holding period following the delivery of the warranty claim Customer will not be required to return the failed product s All returned Product s as may be requested at ROSSLARE ENTERPRISES LTD AND OR SUBSIDIARY S sole discretion shall become the property of ROSSLARE ENTERPRISES LTD AND OR SUBSIDIARIES To exercise the warranty the user must contact Rosslare Enterprises Ltd to obtain an RMA number after which the product must be returned to the Manufacturer freight prepaid and insured In the event ROSSLARE chooses to perform a product evaluation within the sixty 60 day holding period and no defect is found a minimum US 50 00 or equivalent charge will be applied to each Product for labor required in the evaluation Rosslare will repair or replace at its discretion any product that under normal conditions of use and service proves to be defective in material or workmanship No charge will be applied for labor or parts with respect to defects covered by this warranty provided that the work is done by Rosslare or a Rosslare authorized service center Page 53 AC Q4x Family Installation and user Manual Limited Warranty Exclusions and Limitations ROSSLARE shall not be responsible or liab
40. tivated by Forced entry E g In auxiliary mode 6 the controller can triggerthe auxiliary relay if the door has been forced If the Siren Settings is enabled the siren will be activated In this mode the auxiliary input functions asa door monitor switch and is wired to the magnetic contact switch on the door The auxiliary relay isto be wired to the alam system If the dooris forced open the controller will wait forthe period of the forced doordelay time to elapse and then it will activate the auxiliary relay The auxiliary setting sets the forced doordelay period AUXILIARY MODE 7 Auxiliary input function Door Monitor Auxiliary output activated by Door Ajar doorheld open E g In auxiliary mode 7 the controller can triggerthe auxiliary relay if it detectsthat the doorhas been held open ajar too long In this mode the auxiliary input functionsasa door monitor switch and is wired to the magnetic contact switch on the door The auxiliary relay isto be wired to the alam system If the dooris opened the controller will wait forthe doorajardelay time to elapse and if the doordoesnot close priorto the end of this period the controller will activate the auxiliary relay The auxiliary setting defines the door ajartime If the BL D40 Extemal Sounder isconnected in the system and a door ajar event occurs the BL D40 will chime every few seconds for 1 minute or until the door is closed Page 39 AC Q4x Family Installation and user Manual
41. trike isto be released afterthe number of seconds entered 1 to 99 For example 0512 means fail secure operation 0 with5 minutes siren time 5 and a 12 second Lock Strike release time 12 4 System retumsto its normal mode Mode Door e You will hearthree beeps Green e The Doorindicator will tum off e The Mode indicator will tum green 4 8 SETTING AUXILIARY MODES 4 8 1 General The default auxiliary setting is 2004 1 Enterthe Programming Mode Mode Door Green 2 Depress6 to enter Menu 6 Mode e Door e The Mode indicator will flash green Grten Green Page 33 AC Q4x Family Installation and user Manual Programming 3 Constructa code using the instructions hereafter The Quick Reference Guide for Auxiliary Mode 2lhellelle Setting Table providesa quick reference listing forthe auxiliary modesand settings Auxiliary Mode Auxiliary Setting A Auxiliary Relay activation is subject to users Auxiliary code assignment Excluding Shunt which is activated by all users for Il more details see paragraph 4 13 RELAY C ODES ASSIGNMENT Auxiliary Mode In addition to the Lock Strike relay and the Lock Strike REX the controller features an auxiliary output relay and an auxiliary input whose function is established by the auxiliary mode selection 0 thru 9 The auxiliary mode also determines if the auxiliary output relay is set for failsafe or for fail secure operation Fo