Home
User manual - Wassermann Dental
Contents
1. il All instructions for using the unit whether verbal written or in the form of practical guidance are based on individual experience and experimentation and can only be regarded as guidelines Prepare cap as per Point 5 Turn the pressure valve black knob on housing to CLOSED Now increase pressure with the lever staying within the permissible zone on the pressure gauge If necessary increase the pressure to the maximum Once the pressure remains steady it can be released valve opened Raise the piston and remove the cap ST WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor il The gauge will not be accurate while the pressure is being distributed through the plastic Full pressure can only be achieved by pumping on the lever several times with appropriate pauses in between Once the cap is fully enclosed the pressure remains steady 1 return spring the piston takes back automatically to its zero position It has a stroke of about 12 mm As soon as it reaches this level it is limited automatically No more pressure is possible il The oil level should be monitored on the gauge when the piston is down If necessary add hydraulic oil A black vent screw is provided for this purpose To remove oil filler nozzle This is located behind the left hand support at the top of the housing No damage can result from overfilling as the surplus oil merely flows out into the nozzle Note Use
2. SPECIAL DESIGN Working pressure Oil Piston Working range up to 6 tonnes SHELL TELLUS 32 hydraulic oil 95 mm working surface Width 152 mm distance between supports Height min 102 mm Height max 272 mm distance from piston to plate Width 200 mm Depth 158 mm Depth with lever 295 mm Weight 16 k 126999 hydraulic press WW 33 for 1 3 caps Overall dimensions Working pressure Oil Piston Working range up to 6 tonnes SHELL TELLUS 32 hydraulic oil 95 mm working surface Width 152 mm distance between supports Height min 42 mm Height max 212 mm distance from piston to plate Width 200 mm Depth 158 mm Depth with lever 295 mm 14 7 k Overall dimensions Weight Noise emission lt 70 dB A il We reserve the right to make technical changes 12 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 10 CONFORMITY CERTIFICATE accordance with 2006 42 EG machinery guidelines Manufacturer WASSERMANN Product description Hydraulic Dental Maschinen GmbH press for Rudorffweg 15 17 dental D 21031 Hamburg applications Model WW 33 for 2 4 flasks special design Item no 126998 WW 33 for 1 3 flasks Item no 126999 Applicable DIN EN ISO 12100 standards Hiermit wird bestatigt dass die oben bezeichnete Maschine den genannten EG Richtlinien entspricht Diese Erkl rung wird ung ltig falls die Maschine ohne unsere Zustim
3. oc P 2 1 FEATURES ee eet 2 2 FOR YOUR SAFETY iii nies teen ee coe ene Lo reor Deo a 3 YOUR USER re eire nennen rire nenn anne nenn ernennen nn 3 1 TSAFETY GUIDELINES coute En Ett cer de e EXE Enn ex dex Co ee pace dut eco See Peu 4 RESPONSIBILITY FOR OPERATION AND 1 1 ret re rii rre nennen 4 3 APPLIGATIONS 2 ier tuere ee An 5 A BEFORE YOU STAR T 2 22 22 coron ernennen 5 4 1 UNPACKING 1202041 eR reme ret retire tee nn retirer re reser rei 5 4 2 SET UP STORAGEu er DU ai eda 5 5 STARTSUP c 6 6 2252 202 gt eee 6 7 TROUBLESHOOTING CORRECTING 7 8 MAINTENANCE 2 c0cccecceeceeccecceeceeccecceeceeccecceeceecceceeeceeceeceeeseeseeceeeseeseeseesseneeeeees 8 8 1 CLEANING 0c ccccecceeccecceeceeeceecueeaeeceecaecaeeceeaecueceeaecueaecaeceenecuesecueceeaesueaesuesueaeseeaeeesaes 8 O 9 VVARPANTVIS 8 8 4 SP
4. ANN DENTAL MASCHINEN Die Basis f r Ihr Labor 8 2 Maintenance Your Wassermann hydraulic press is maintenance free Just make sure that it is kept clean 8 3 Warranty The warranty period for our instruments is 12 months If faults occur within the warranty period contact your dental depot or get in touch directly with our Service department Your hydraulic press should only be operated in perfect condition If faults occur which could harm operators or third parties the unit should not be used until it has been fixed This warranty does not cover damage caused by improper use external mechanical causes transport damage or interference with the unit by unauthorized persons 210 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 8 4 Spare parts and accessories Spare parts Description Lever Selector switch compl Round ball DIN 319 D25 x M6 black Square ring 6 x 1 5 for piston Rubber foot D20 H5 black 629004 Hydraulic oil in 100 bottle 629005 Hydraulic oil in 500 ml bottle Accessories 8 5 Repairs Servicing or repairs to the unit must only be carried out by trained technicians Only original spares are to be used Responsibility for the product is voided if altered by unauthorized persons or if inappropriate components are installed Ae WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 9 Technical data 126998 hydraulic press WW 33 for 2 4 caps
5. ARE PARTS AND nennen re resin ias 10 8 5 ae ehe siehe orig 10 9 TECHNICAL an nun nenne 11 126998 HypRauLic PRESS WW 33 For 2 4 caps SPECIAL DESIGN 11 126999 HYDRAULIC PRESS WW 33 FOR 1 5 11 10 EC CONFORMITY GERTIFICATE una 12 ee WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 1 Features The WW 33 hydraulic press with continuous pressure up to 6 tonnes presses caps individually and appropriately for the material used After ending one pressing it is immediately ready for further use as its solid plastic piston returns automatically once the valve has been opened A quality pressure gauge which shows the pressure achieved with great accuracy is recessed into the housing and is thus protected from dirt WW 33 s oxidation free piston plastic tensile steel construction no risk of breaking and sturdy plastic coated housing all contribute to the unit s long service life As the distance between supports is 152 mm the press is also suitable for larger caps IVOCAP and stirrup pieces SPECIAL DESIGN WW 33 hydraulic press is also available with longer supports for 4 caps 2 For your safety Your user manual Configuring and operating this equipment requires pre
6. User manual WW 33 hydraulic press 3 or 4 flasks Figure 1 WW 33 1 3 caps WASSERMANN DENTAL MASCHINEN GMBH il WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Dear customer Thank you for choosing a product from the Wassermann range Wassermann dental equipment incorporates the highest standards of quality and the latest technology In order to enjoy maximum performance and years of trouble free operation please read this instruction manual carefully before you connect this device and start work and operate the device according to the recommended guidelines The operation safety and the functionality of this device can only be guaranteed if you follow both the general safety guidelines and the applying laws to prevent accidents as well as the precautions given in this instruction manual We are not liable for any damages which occur due to inappropriate usage or faulty operation of this device Make sure that anyone using this device has read and understood this instruction manual Keep this instruction manual in a safe place where it can be referred to as required at any time Company address Wassermann Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Germany Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 E mail info wassermann dental com URL http www wassermann dental com xs WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Contents CONTENTS
7. cise knowledge and observance of the instructions in this user manual The equipment is designed only for its intended application Very important features are indicated as follows in this manual Warning This is a warning of risk situations and dangers Failure to observe A this warning could be life threatening These warnings must be observed Information i This symbol draws your attention to specific features which should be noted de WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 1 1 Safety guidelines e none Responsibility for operation and damage The responsibility for operating the unit lies exclusively with the owner or user if the said unit is incorrectly serviced maintained or altered by persons not employed by an accredited dealer or if the unit is used in a manner contrary to its specified purpose The unit must be maintained and operated in accordance with this user manual Wassermann Dental Maschinen GmbH is not responsible for damage arising from the non observance of these instructions Guarantee and responsibility provisions contained in the sales and supply conditions of Wassermann Dental Maschinen GmbH are not extended by these instructions il Ensure that this user manual is accessible at all times and has been read and understood din WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 3 Applications With a continuous working pressure of up to 6 tonnes t
8. he WW 33 hydraulic press is used to press caps individually and in accordance with the material used Only use the device for this type of application 4 Before you start 4 1 Unpacking Transport Open the cartons remove the packing materials and carefully lift out the instrument and accessories Check that the accessories are correct see 8 4 When transporting the unit use appropriate packing materials to avoid accidental damage 4 2 Set up Storage il The press must be at room temperature before you use it Set the unit up on a flat surface Always ensure that the work area is sufficiently large take the unit s dimensions into account Do not set it up out of doors If the unit is to be stored for an extended period protect it from moisture and dust Before you start the press 1 Take the pump lever out of the union piece 2 Undo the bolt and remove the safety packing Insert the lever and secure it with the bolt 3 Screw the ball on the end of the lever in WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 5 Start up Centre the cap on the piston to guarantee even pressure distribution Bring down the piston on the cap il The usual pressure is between 2 5 and 5 tonnes This is shown in the green area on the pressure gauge To avoid damage to the cap and the press do not pump beyond the zone on the pressure gauge 6 Operation
9. mung ver ndert wird This is to confirm that the above mentioned machine complies with the described EC rules This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur de la Communit Europ ene Cet avis est nul et non avenant si cette machine est modifi e sans notre accord Esta m quina anteriormente mencionada cumple con los limites requeridos por el reglamento EC Ahora bien esta declaraci n quedar invalidada en caso de realizar modificaciones al aparato sin nuestra aprobaci n Hiermee wordt bevestigd dat bovengenoemde machine voldoet aan de voorgeschreven EU normen Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke toestemming wijzigen aan de machine worden aangebracht Place date Hamburg 07 03 13 Company stamp Signature Wilfried Wassermann Managing Director 13 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Notes ds WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor WASSERMANN DENTAL MASCHINEN WASSERMANN Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 e mail info wassermann dental com Internet http www wassermann dental com
10. only SHELL TELLUS 32 hydraulic oil 7 Troubleshooting Correcting errors Fault Likelycause 7 Liklyscution Little or no pressure Oil level below minimum press as explained builds and air bubble has below entered system during filling Pressure drops to zero Dirty pressure valve Pump strongly with newly despite enclosed cap or filled oil recommended oil piston rises under pressure i WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor GUIDELINES FOR VENTING 1 Turn press on right side and pump 2 Nothing then remove piston as described below fill with oil up to top edge of cylinder Undo set screw U piece Pull lever forwards Pull piston up and out of cylinder Fill with oil recommended oil Re install in reverse order watching out for two points a Do not tip the piston b Do not damage the square ring If the above recommendations do not solve the problem contact your dental depot or our Service department 8 Maintenance 8 1 Cleaning The unit should be cleaned at regular intervals to ensure trouble free operation Use normal cleaning products sponge soft cloth mild detergent but no chemical additives The piston track should be cleaned daily with a clean linen cloth and then lightly lubricated with the recommended hydraulic oil The model plate must always be legible and should not be removed e WASSERM
Download Pdf Manuals
Related Search
Related Contents
CONTINUOUS FLOW ICEMAKER Bedienungsanleitung Operating instructions Manual de instruções intext:Bedienungsanleitung filetype:pdf GeoNorgP Manual de Usuario de la Aplicación GeoInfoMex para Android 第77期定時株主総会招集ご通知 (PDFファイル 511KB) Copyright © All rights reserved.
Failed to retrieve file