5400 Installer Manual
Contents
1. stage conventional u HP 22HP 2 stage conventional single stage 32 HP heat pump 2 stage heat pump or 3 stage heat pump 7 First Stage IHG IHONHE Not available with a heat pump Fan Control system Selects between 1st stage gas or electric heat 8 Aux Stage Control 2HE 2HE 1H Only available with multi stage heat pump system Selects multi stage gas or electric heat 9 Fossil Fuel AUHAE AUHAE Only available with a multi stage Backup Option AUHAB heat pump system Locks out 1st stage during 2nd stage heat call for fossil fuel backup system AUXAG With an electric backup system AUXAE both stages will run 10 AC Power ore AC ore AC Only available when thermostat is Interrupt Warning on AC installed as a hardwired unit Select between turning the AC power interrupt warning off or on Installer Options 11 Compressor Power Outage 12 Short Cycle Protection 13 Residual Cooling Fan Off Delay 14 Recirculating Fan Lock 15 Enable Disable ARM 16 Set Sensor Control IMPORTANT At installation Remote Indoor Sensor must be at room temperature 17 Set Security Level for Keypad Lock 18 Humidification Option 19 Automatic Humidity Set Point Limit 20 Dehumidification Option 21 Zero Stage Dehumidification Differential 22 Dehumidification Fan Speed Control 23 Dead Band Factory Default crap UF cscp 5
2. system should stop within several seconds 4 Scroll through system settings to COOL 5 If the compressor has previously been running then you must wait 5 minutes or until the installer programmed delay set in Section 4 Option 12 for the automatic compressor short cycle protection period to expire You can also press the RESET button to bypass this feature for initial testing purposes See Section 4 Page 5 for a list of all functions that will return to their factory default settings after the RESET button is pressed 6 Press the V button on the keypad until the set point temperature is a minimum of 3 degrees lower than the current room temperature 7 The cooling system should start within several seconds Scroll through system settings to OFF The cooling system should stop within 90 seconds dependent on the setting of the Residual Cooling Fan Feature 8 Scroll the fan settings to ON the system blower should start 9 Scroll the fan settings to AUTO the system blower should stop 10 If thermostat is controlling auxiliary equipment adjust thermostat setting to test humidifier economizer etc if applicable 12 L Wiring Diagrams Remove Factory Installed Jumper Co
3. than installer setting Select from no lockout or a setting between 10 F to 50 F 9 C to 10 C Only available with multi stage heat pump and outdoor sensor connected Locks out the use of the auxiliary heat stage for outside air temperatures over installer setting Select from no lockout or a setting between 70 F to 40 F 21 C to 4 C NOTE This balance point overrides the fossil fuel compressor lockout If the lockout is set to AG and the outdoor temperature is over the AUX balance point the compressor will remain on during a second stage call The unit will recover to the set point without the AUX stage Selects Outside Air Intake Options Scroll between none disabled economizer mode and time of day mode Enables the operation of an outside air damper system in either the economizer mode or time of day mode Not available unless the Dehumidification Fan Speed Limiting is set to NO Available only in commercial mode Selects the heating set point upper limit scrolls between 90 F and 60 F 32 C and 10 C 28 Selects the cooling set point lower limit scrolls between 45 F and 80 F 7 C and 27 C Time Step Override Cooling Call External Air Output A Economizer Time of Disabled Mode Day Mode Occupied YES or NO ON ON OFF Unoccupied YES ON OFF OFF NO OFF OFF OFF Override YES or NO ON ON OFF 11 4 Testing the Thermostat _ WARNING Read BEFORE Testing e Do no
4. together for 3 seconds Installer Option 1 Residential or Commercial will be displayed Pressing the Aor V buttons will scroll between choices To scroll to the next installer option press the RETURN button To scroll backwards between installer options press the PROG button The thermostat will return to normal operating mode by pressing the RETURN and PROG buttons at the same time NOTE The thermostat will return to normal operating mode automatically after 30 seconds if no buttons are pressed NOTE Any changes to Installer Option 6 System Type will cause Options 7 8 9 10 and 11 to reset to the default values that are dependent on system selection NOTE Any changes to Installer Options 1 through 6 will cause all User Options and Programming to reset to their default values if the User Options were previously programmed See User Manual Section 2 see page 8 for Installer Options Factory Default Options Comment more information 1 Residential or RES RES BUS Selects a Residential or Commercial Commercial BUS profile 2 Programming PROSI PAGE Not available if thermostat Mode paceSe is in the Commercial PRSNO BUS profile 3 12 24 Clock ih IZh Hh Selects either 12 hour or 24 hour clock 4 Temperature Scale S 6F GESF C66 Selects either Fahrenheit or Celsius 5 Auto Changeover AUECUT puesii Either enables or disables AuULOUFE Auto Changeover 6 System Type ne Heel Selects single
5. Braeburn 5400 Premier Series Universal Auto Changeover Up to 3 Heat 2 Cool Conventional and Heat Pump Thermostat Installer Guide Before Installing Programming or Operating PLEASE READ ALL INSTRUCTIONS 1 Specifications 2 Installation 3 Quick Reference 4 Programming Installer Settings SEE USER MANUAL FOR TROUBLESHOOTING Important Safety Information 5 Testing Thermostat 6 Wiring Diagrams e Always turn off power to the air conditioning or heating system prior to Installing removing cleaning or servicing thermostat e This thermostat is a dual power thermostat and either requires 24 Volt AC Power or two 2 properly installed AA Alkaline batteries for normal operation and control of the heating or cooling system e Properly installed batteries will allow the thermostat to retain clock settings in the event of loss of AC Power due to power outage or rolling blackouts when used as a hardwired thermostat e This thermostat should only be used as described in this manual Any other use is not recommended and will void the warranty l V Specifications e Electrical Rating 24 Volt AC 18 30 Volt AC 1 amp maximum load per terminal 6 amp maximum load all terminals e Control Range 45 90 F 7 C 32 C e Accuracy 1 F 5 C 3 RH e AC Power 18 30 Volt AC e DC Power 3 0 Volt DC 2 AA Alkaline batteries included 2008 Braeburn Systems LLC Patents Pending Al
6. FANBU OFF DEHUMID OGIF mm VUIF LU Fan NO DEHUMID Bano 3 Options CPOPUF cpap DN cscp 5 csce 4 cscp 3 cscpe csce 0 ran DO can sv Fan 6G Fan SO ciacOF rec Of nec OF SENSI SENSE Sensh SEC I SECO none HUMID OFF DEHUMID n DEHUMID c 3 CICICICI EHUMID EHUMID DEHUMID nnn e pe e Bane 2 Bans 3 Bana 4 Bane S i Programming Installer Settings conr Setting Thermostat Installer Options continued Comment Only available with multi stage heat pump and AC power protection connected Select between compressor lock off and compressor lock on Selects 5 4 3 2 or 0 minutes for the compressor short cycle protection Selects 0 30 60 or 90 seconds as the time the fan will stay on after the cooling system has satisfied the set point temperature and turned off the compressor Selects between Recirculating Fan Lock off or on Enables or disables ARM Not available in non programmable mode Selects between Internal 1 External E and Averaging A and Averaging control of Internal and External indoor sensor for temperature control or Outdoor sensor for humidity or balance point control This option is only available if the remote sensor is connected Selects between level 1 or level 2 keypad lockout Selects between None humidification disabled Dependant manual and Independent humidification Not available unless Sensor Con
7. GorF G Fan Control Rc 24 Volt AC Cooling for Dual Transformer Systems R V VR or VR R Rh 24 Volt AC W1 W2 or W U W2 Stage 2 Heating B B Reversing Valve Heating OorR 0 Reversing Valve Cooling Y Y1 or M vi Stage 1 Compressor Y2 Y2 Stage 2 Compressor W1 E W3 W1 E W3 1st Stage Heating for Conventional Systems or Emergency Heating for 3 Stage Heat Pumps C Xor B C 24 Volt AC Transformer Common LorX L System Malfunction Indicator Si S1 Optional Remote Sensor S2 2 Optional Remote Sensor we Installation cont Replacing Existing Thermostat continued 4 After labeling the old wires loosen each connection and remove them from old sub base Secure the wires to prevent them from slipping into the opening in the wall 5 Remove the old sub base from the wall again being careful that the wires do not slip into the opening in the wall 6 Use the chart on page 1 to determine the new thermostat connections As an example if the old thermostat had a G or F connection it goes to G on the new thermostat It may be helpful to use the chart by circling with a pencil or pen the letter of each wire removed from the old thermostat NOTE This thermostat is designed for use on low voltage 24 volt AC single stage or multi stage systems including heat pumps with up to three stages of heating and two stages of cooling Do not use this thermostat on systems with voltage higher than 30 Volts AC This thermostat requires a
8. NONE manual control DEP or independent control IND The DEP setting controls humidification only during heating calls The IND setting allows humidification output in the heat mode but does not require a heat call Braeburn recommends that the IND setting only be used with systems designed for low air temperature humidification such as steam humidification Always ensure the heat exchanger or other system parts are NOT exposed to excess water from condensation or other sources When there is any doubt use the NONE or DEP setting Only available if outdoor sensor is connected and humidification is enabled Select between turning the Automatic Humidity Set Point limit OFF or ON Selecting OFF lets you set the Automatic Humidity Set Point manually Selecting ON limits the automatic set point which reduces the chance of condensation on windows Enables or disables Dehumidification Zero stage dehumidification differential selects the number of degrees the system is allowed to over cool in attempting to reduce humidity Options available when dehumidification is enabled are 1 2 or 3 F continued 10 24 25 26 27 Dehumidification Allowable Dead Band Zero Stage Differential Dehumidification not Enabled 2 3 4 or 5 F TF 3 4 0r 5 F ak 4or5 F 3 F 5 F Only available with multi stage heat pump and outdoor sensor connected Locks out the use of the compressor heat stage for outside air temperatures less
9. common C terminal must be connected Braeburn YEAR LIMITED aog WARRANTY ey Bk EZ ED Store this booklet for future reference Braeburn Grog ti C Braeburn Systems LLC as an Energy Star partner has determined that this product meets the Energy Star Guidelines developed by the U S Environmental ENERG Protection Agency amp the U S Department of Energy for maximum energy efficiency For more information on energy savings go to www energystar gov Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are due to faulty material or workmanship for a period of five years after the original date of purchase by a professional service technician This warranty and our liability does not apply to batteries nor does it include damage to merchandise or the thermostat resulting from accident alteration neglect misuse improper installation or any other failure to follow Braeburn installation and operating instructions Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period with proof of the original date of purchase and a brief description of the malfunction This limited warranty does not include the cost of removal or re installation This warranty gives you specific legal rights and you may also have other rights that vary from stat
10. disabled Economizer Mode and Time of Day Mode 27 Heating Set Point HER SO HERE 90 Scrolls between 90 and 60 F Upper Limit HERt BO 82 and 10 C 28 Cooling Set Point coo 45 coo 45 Scrolls between 45 and 80 F Lower Limit coo 80 7 and 27 C _ Selects Residential or Commercial BUS profile Determines programming events per day If Residential is selected 4 events per day are available If Commercial is selected 2 events per day are available Only the 7 day programmable mode is available for the Commercial profile 2 Selects the programming mode either full 7 day or 5 2 day weekday weekend programming or non programmable If the Commercial profile was selected in step 1 this option is not available 3 Selects either a 12 hour or 24 hour clock 4 Selects preferred temperature scale of either F or C 5 Selects Auto Changeover on or off When off is selected the AUTO icon will not be displayed when selecting the system options with the system switch When Auto Changeover mode is enabled and selected the system automatically switches between heating and cooling when the room temperature meets the programmed heating or cooling set points 6 Selects single stage conventional 11C 2 stage conventional 22C single stage heat pump 11HP 2 stage heat pump 22HP or 3 stage heat pump 32HP Any change made to the system type resets Installer Options 7 through 11 to their default values dependen
11. e to maintain the set point temperature The compressor lockout can be disabled by setting this option to OFF This thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling This thermostat automatically provides an adjustable delay after turning off the cooling system output to protect the compressor This protection is also present in the heat mode of operation on single stage heat pump systems to protect the compressor During the COOL mode of normal operation the fan will stay on for 60 seconds after the cooling system has satisfied the set point temperature and has turned off the compressor This allows the system to provide higher efficiency during cooling operation The delay is selectable between 0 30 60 or 90 seconds The Recirculating Fan can be locked on so that the only fan selections available to the user are CIRC and ON The Recirculating Fan Mode provides more even temperature distribution and improves indoor air quality by circulating air through the furnace filtration system more often By locking the Recirculating Fan on the user will only have the option to run the fan all the time ON or use the Recirculating Fan Feature CIRC If the Recirculating Fan lock is set to off the thermostat is put into the Recirculating Fan Mode by pressing the FAN button until the CIRC icon is displayed If no call for heating or cooling occurs within the fan off cycle s
12. e to state or province to province Answers to any questions regarding our limited warranty may be obtained by writing our corporate offices WARRANTY FACILITY Braeburn Systems LLC Attn Warranty Department 2215 Cornell Avenue Montgomery IL 60538 Braeburn Braeburn Systems LLC 2215 Cornell Avenue Montgomery IL 60538 Technical Assistance www braeburnonline com Call us toll free 866 268 5599 U S Only 630 844 1968 Outside the U S 2008 Braeburn Systems LLC Patents Pending All Rights Reserved Made in China No 5400 100 007
13. es in the wall 6 Place the thermostat sub base against the wall in the desired location Ensure the thermostat is level the wires are inserted in the opening and the mounting holes are aligned with the slots on the sub base 7 Fasten sub base to wall using supplied screws into the plastic wall anchors 8 Connect wires to the quick wiring terminal blocks Use the wiring diagram chart to ensure the old and new connections are correct 9 To prevent electrical shorts and potential damage to the thermostat make sure all wire connections are secure and not touching each other 10 Locate the thermostat body and ensure the cover is still installed properly Using the mounting tabs on the top of the sub base as a guide or hinge close up the thermostat case by pivoting the body and cover closed The latch on the bottom of the thermostat will click when the case is properly closed Because this thermostat has 15 possible connection points you may need to apply moderate force to close the case continued on page 3 2 wz Installation cone Installing New Thermostat continued 11 Flip the front thermostat cover up and open the battery compartment door 12 Locate the positive ends of the batteries and match them with the positive terminals located in the battery compartment Install the two new AA alkaline batteries supplied Close battery compartment door 13 Restore system power and proceed to programming and system checkou
14. et in the User Options see User Manual the fan will run for 24 minutes When the fan lock is set to on the highest setting 120 minutes will run the fan least often 9 minimum running time The lowest setting 24 minutes factory default will run the fan most often 33 minimum running time The Recirculating Fan feature is available in the COOL OFF HEAT or EMER mode Enables or disables the ARM feature During ARM room temperature is recovered gradually by turning on the heating or cooling before the end of the set back period In a multi stage configuration room temperature is recovered gradually by using only the first stage heating or cooling until the last 20 minutes to minimize the use of the 2nd stage heating or cooling The set point temperature is changed to that of the upcoming comfort program temperature The start time of recovery is based on the difference between the current room temperature and the upcoming comfort program set point temperature The recovery to the upcoming heating set point starts 10 minutes before the upcoming set point time for each degree of temperature change required up to a maximum of 2 hours The recovery to the upcoming cooling set point starts 15 minutes before the upcoming set point time for each degree of temperature change required up to a maximum of 3 hours ARM does not operate when the unit is in the temporary or permanent HOLD mode or if the program is temporarily overridden o
15. g off NO or on D output normally active NA and D output normally inactive NI 23 When Auto Changeover mode is enabled and selected the system automatically switches between heating and cooling when the room temperature meets the normal criteria for either a heating or cooling call There is a forced separation dead band between the heating and cooling set points so the systems do not work against each other This option selects Auto Changeover Dead Band of 2 3 4 or 5 F The default is 3 F unless dehumidification is enabled When dehumidification is enabled the deadbands are as follows 17 18 19 20 21 Option Setting Temperature Balance Points and Control Humidity Set Limit Control Outdoor Display sens Internal At Thermostat N A Thermostat Sensor sens R Remote At Remote Sensor N A Indoor Sensor sens A Internal Average between N A and Remote Internal and Remote The keypad lockout feature has two levels of security Level one locks all buttons including the reset except for the A Vand backlight buttons Level 2 locks the entire keypad except the backlight button The A and V buttons can be pressed together to enter the lock code but the buttons do not work individually to adjust the temperature The lock level is set during the Installer Options and the lock code is set in the User Options See the User Manual Section 2 Selects between disabling humidification
16. ither for Outdoor or Indoor Remote Sensor depending on installer settings 4 Terminal can be used either for Outside Air Control or Dehumidification Fan Speed Reduction depending on installer settings 5 For millivolt or other 2 wire heating systems connect wires from heating control to R and W1 uy Wiring Diagrams One and Two Stage Heat Pump Systems Outside Air Control or Fan Speed Reduction Relay NOTE 7 Outside Air Control or Fan Speed Reduction Relay NOTE 4 Factory Installed Jumper See NOTE 5 pa A D H G Rc Rh w2 B 0 Y1 Y2 W1 E W3 C L S1 S2 S SD O OOOO D S iif 2nd Stage Reversing Valve Heat Control Active in S NOTE 2 Cooling See Es E 3 amp e o Fan Control Tst Stage Emergency F Remote Compressor Heat Control 2 8 Sensor Control See NOTE 4 5 T NOTE 6 Neutral 120 VAC Hot NOTES 1 Transformer Common connection not required for battery only operation of thermostat 2 Second Stage Control connections not used for single stage heating or cooling systems 3 For units requiring reversing valve to be energized during heating connect reversing valve to B terminal For units requiring reversing valve to be energized during cooling connect reversing valve to O te
17. l Rights Reserved Pub No 5400 100 007 Specifications cont e Compatibility Compatible with low voltage single stage or multi stage Heat Cool systems including heat pumps with up to three stages of heating and two stages of cooling This thermostat can also be used on 250 to 750 millivolt heating only systems e Terminations A D H G Rc Rh W2 B O Y1 Y2 W1 E W3 C L 1 S2 3 Installation Replacing Existing Thermostat Most existing thermostats have three parts e The cover which may snap or hinge over the existing thermostat e The electronics or body which controls the existing system e The sub base where the wires attach through the wall to the existing system 1 Always turn off power to the air conditioning and heating system prior to removing existing thermostat 2 Carefully remove the cover and electronics body from the old thermostat sub base Depending on the brand these parts may pull off or need to be unscrewed The old sub base should remain wired and on the wall until steps 4 and 5 3 Label every old wire with the letter of the connection to which the wire is attached Example letters are R M Y etc Depending on the brand of the old thermostat your letters may be different continued on page 2 Old Terminal from New Terminal for Existing Thermostat New Thermostat Terminal Description Model 5400 A DHM A D External Air output or Fan Speed Reduction Relay H H Humidifier Output
18. nabled Permanent and temporary hold cleared AUTO 12 00 pm Monday Display 70 F 21 0 C to be renewed within 5 seconds 62 F 17 0 C for Heat and Emergency Heat 83 F 28 0 C for Cool Fahrenheit DAY program Monday Off to be renewed within 5 seconds Off to be renewed within 5 seconds 5 F 0 2 C 2 F 1 0 C 2 F 1 0 C 7 Day 4 Event PIE 60 seconds On 5 minutes Reset ON All turned off Timer reset with 24 min OFF 12 min ON Lock OFF Long indefinite 0 days No Warning Timer reset Complete level 2 unlocked 555 universal code Conventional Single Stage Gas Electric Off Enabled Off Timer reset Internal 12 hour 0 OFF OFF Residential 0 deg No Lockout iy Programming Installer Settings conr Status After CLEAR Factory Default Settings continued Function Auxiliary Balance Point Humidification Dehumidification Economizer Control UV Monitor Humidifier Pad Monitor Heat Limit Cool Limit Maximum Override Duration Zero Stage Differential for Dehumidification Maximum Humidification Set Point Limit Dehumidification Fan Speed Reduction Status After CLEAR 0 deg No Lockout 10 disabled 80 disabled None Disabled 0 days No Warning Timer reset 0 days No Warning Timer reset 90 deg No Limit 45 deg No Limit 4 hours 1 0 F ON OFF Disabled Status After RESET Factory Default Setti
19. ngs When the User RESET button is pressed the following options will reset to the factory defaults All other settings are saved when the RESET button is pressed Function Programming Clock ist stage differential 2nd stage differential 3rd stage differential Filter UV and Humidity Pad Check Monitor Adjustment Limit from Set Point Temperature Hold Short Cycle Timer Recirculating Fan Humidification Setting Dehumidification Setting Maximum Temporary Override Duration Status After RESET Default setting depending on programming mode setting see User Manual For manual mode Heat 62 F Cool 83 F 12 00 pm Monday P E G 2 F 1 0 2 F 1 0 C 0 days No Warning Timer reset 0 OFF Permanent and temporary hold cleared reset to Long Hold Reset Timer reset 24 minute off cycle With recirculating lock set fan state defaults to CIRC 10 80 4 hours i Programming Installer Settings conz Setting Thermostat Installer Options The Installer Options section allows the system and programming parameters to be set up at installation The Installer Options mode is menu driven As the different options are programmed you may eliminate specific options For example if the system is set to single stage heat pump Option 8 selecting the AUX stage fan control will no longer be available The Installer Option mode is entered by holding the RETURN and A or V buttons
20. nventional Systems Dual Transformer A D H G Rc Rh Ww2 B 0 Y1 Y2 W1 E W3 C L S1 s2 ao E EE E E E E a DF GBD VD D iif 2nd Stage Compressor Heat Humidifier Heat Control Control S Control Se Remote Outside Air Fan Control g Sensor Control or Fan S NOTE 2 Speed Reduction S Relay NOTE 3 gt N L _ Neutral A C 24 VAC 120 VAC a Hot Neutral Heating 120 VAC 24 VAC Hot J ig Cooling NOTES 1 Transformer Common connection not required for battery only operation of thermostat 2 Remote Sensor Terminals can be either for Outdoor or Indoor Remote Sensor depending on installer settings 3 Terminal can be used either for Outside Air Control or Dehumidification Fan Speed Reduction depending on installer settings 4 For millivolt or other 2 wire heating systems connect wires from heating control to R and W1 Factory Installed Jumper Conventional Systems Single Transformer A D H G Re Rh w2 B 0 Y1 Y2 W1 E W3 C L S1 s2 aODQOTQGD DO FAA GF G amp G GS DS Humidifier ist Stage Tst Stage Compressor Heat Control Control sz Outside Air Fan Control S 8 Control or Fan 2nd Stage i emor Speed Reduction Heat Control SS NOTE 3 Relay NOTE 4 NOTE 2 s gt Neutral gt 24 VAC 120 VAC 4 Hot NOTES 1 Transformer Common connection not required for battery only operation of thermostat 2 Second Stage Control connections not used for single stage heating or cooling systems 3 Remote Sensor Terminals can be e
21. ow button for 3 seconds PROG and DAY TIME Buttons When pressed at the same time displays the current room humidity and humidification set points HOLD and PROG Buttons When pressed at the same time displays outdoor sensor if installed and enabled CLEAR Button Located on the back side of the circuit board resets thermostat to all factory default settings See Page 4 and 5 for a complete listing e600 00 O 3 i Programming Installer Settings Status After CLEAR Factory Default Settings At initial power up or after Installer CLEAR is pressed the thermostat is reset to factory defaults Installer CLEAR is located on the circuit board Function Operation mode Temperature hold Fan Switch Clock Room temperature Set point temperature Temperature scale Operating program Low battery warning AC interrupted warning 1st stage differential 2nd stage differential 3rd stage differential Programming Deadband Residual Cooling Fan Delay Short cycle protection timer Adaptive Recovery Mode Output relays Recirculating Fan Extended Hold Filter Check Monitor Keypad Lock System type 1st Stage Heat Fan Control 2nd Stage Heat Fan Control Fossil Fuel Compressor Lock Auto Changeover Compressor Outage Protection Temperature Sensor 12 24 Hour Clock Adjustment Limit from Set Point AC Interrupt Warning Mode User Profile Compressor Balance Point Status After CLEAR OFF Auto Changeover e
22. r if emergency heat is selected for multi stage heat pumps If the ARM feature is disabled the thermostat will recover the set point temperature at the programmed set point time after the setback period ends Lp Programming Installer Settings cone 16 If a Braeburne indoor or outdoor remote sensor is connected during installation the thermostat will automatically detect the type of sensor When an indoor sensor is detected you may select between internal sensl external sensE or averaging sensA of internal and external for temperature control When an outdoor sensor is automatically detected the thermostat will remove the choices for indoor sensing from the menu and enable outdoor measure ment The outdoor sensor may be used to determine if balance points have been exceeded for outdoor temperature dependent humidity control and outdoor temperature display For proper auto detection you must use a Braeburn brand external sensor Should the external sensor become unwired the thermostat will retain the settings but the balance points temperature dependent humidity control and outdoor temperature display will be disabled until the external sensor is repaired Test the operation of the external sensor by pressing the PROG and HOLD buttons at the same time i Programming Installer Settings cone 22 Feature accommodates either a normally open relay or a normally closed relay Selects between Dehumidification fan speed limitin
23. rminal 4 Required for units with 2 stage heat only 5 For 2 stage heat units not having a separate Emergency Heat Terminal add installer supplied jumper 6 Remote Sensor Terminals can be either for Outdoor or Indoor Remote Sensor depending on installer settings 7 Terminal can be used either for Outside Air Control or Dehumidification Fan Speed Reduction depending on installer settings 8 If L Terminal is used 24VAC common C terminal must be connected Factory Installed Jumper Three Stage Heat Pump Systems A D H G Re Rh W2 B 0 Y1 Y2 W1 E W3 C L S1 s2 aaO O D Dd D Humidifier Reversing Valve 2nd Stage Active in Compressor Cooling See Control 5 NOTE 2 Ea Se Fan Control Reversing Valve Ist Stage Aux Heat 55 Remote Active in Compressor Control SA Sensor Heating See Control s8 NOTE 3 NOTE 2 E Neutral 24 VAC 120 VAC Hot NOTES 1 Transformer Common connection not required for battery only operation of thermostat 2 For units requiring reversing valve to be energized during heating connect reversing valve to B terminal For units requiring reversing valve to be energized during cooling connect reversing valve to O terminal 3 Remote Sensor Terminals can be either for Outdoor or Indoor Remote Sensor depending on installer settings 4 Terminal can be used either for Outside Air Control or Dehumidification Fan Speed Reduction depending on installer settings 5 If L Terminal is used 24VAC
24. t i gt Quick Reference Model 5400 shown with cover open SYSTEM PROG HOLD RETURN DAY TIME FAN BRI SYSTEM Button Selects AUTO Heat Cool COOL OFF HEAT or EMER PROG Button Program setup mode selects set point time set point temperature and fan setting for each program Scrolls backwards between installer setup screens HOLD Button Enables extended hold clears extended hold or temporary override RETURN Button Scrolls between installer setup screens or returns unit to the normal mode from program mode Option setting mode for stage differential and residual cooling Is entered when holding the RETURN button for 4 seconds when in the normal mode DAY TIME Button Selects hour minute and day setting Selects program day in program setting mode FAN Button Selects AUTO ON CIRC recirculate and PROG program modes RESET Button Located on front of thermostat See Page 5 for a list of all functions that will return to their factory default settings after the RESET button is pressed 3 Button Turns on backlight for 10 seconds A Button Increases setting time temperature etc Scrolls between option settings V Button Decreases setting time temperature etc Scrolls between option settings RETURN and PROG Buttons When pressed at the same time returns unit to the normal mode from Installer setup option mode To enter installer mode press and hold both the RETURN and the A arr
25. t on system selected 7 Selects between 1st stage gas or electric heat Fan Control This Installer Option is not available with a heat pump system 8 Selects aux stage gas or electric heat Fan Control This Installer Option is only available with a 2 or 3 stage heat pump system 9 For heat pump units with an electric auxiliary stage both the first and second stages of heating will run when a call for second stage heat is made For heat pump units with a fossil fuel auxiliary stage the compressor stage s will be locked out one minute after a second stage heat call and the second stage will only be used NOTE Can be overridden by auxiliary balance point See item 25 on page 11 for details i Programming Installer Settings cone 10 11 12 13 14 15 Select between turning the AC power interrupt warning off or on During a power loss the thermostat will display an outage warning The system clock will continue to run and all settings will be maintained until the outage period is over This Installer Option is only available when thermostat is installed as a hardwired unit This thermostat provides cold weather compressor protection by locking out the compressor stage 1st stage of heating for a period of time after a power outage greater than 60 minutes The lockout period is one hour less than the outage time up to a maximum of 12 hours During that period of time the auxiliary heat stage will still be availabl
26. t short or jumper across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation This could damage the thermostat and void the warranty e Do not select the COOL mode of operation if the outside temperature is below 50 F 10 C This could possibly damage the controlled cooling system and may cause personal injury e This thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling The default is to provide a 5 minute delay after turning off the cooling or heating output to protect the compressor This default can be changed in Section 4 Option 12 Programming Installer Options NOTE Test your thermostat prior to programming any user settings Pressing the Installer CLEAR button will reset the thermostat to all factory default settings See Page 4 and 5 for a complete listing See Page 5 for a list of all functions that will return to their default settings after the RESET bution is pressed 1 Using the system button scroll through settings on the left side of the display to HEAT 2 Press the A button on the keypad until the set point temperature setting is a minimum of 3 degrees higher than the current room temperature The heating system should start within several seconds The fan may not turn on immediately due to the heating system built in fan delay 3 Scroll through system settings to OFF The heating
27. transformer common wire for proper installation if used as a hardwired thermostat Installing New Thermostat NOTE When installing this thermostat in a new location following a few simple guidelines and the applicable building codes will give the best results Install the thermostat in a location that provides good airflow by avoiding areas behind doors near corners air vents direct sunlight or heat generating devices The wiring must conform to all building codes and ordinances as required by local and national code authorities having jurisdiction for this installation 1 Always turn off the power to the air conditioning and heating system prior to installing this thermostat 2 Locate the release latch on the bottom not the back of the thermostat Press the release latch in and separate the body from the sub base of the thermostat Because this thermostat has 15 possible connection points you may need to apply moderate force to separate the parts 3 Set the thermostat electronics and cover down on a clean surface Place the sub base on the wall in the desired location 4 Using the slotted mounting holes in the sub base mark the placement of the mounting holes through the slots and onto the wall Ensure the wires come out of the wall into the center hole of the sub base 5 After verifying the drill will not damage items in the wall use a 3 16 drill to create the mounting holes Gently tap the supplied plastic anchors into the hol
28. trol is set to sens O and Humidification Option is enabled Selects between automatic limiting of humidification set point to on or off Selects between Dehumidification Option off or on Not available if Dehumidification Option is set to OFF Automatically adjusts deadband Selects between Dehumidification fan speed off NO D output normally active NA and D output normally inactive NI Not available if dehumidification option is set to OFF Selects Auto Changeover Dead Band of 2 3 4 5 F 1 0 1 5 2 0 2 5 C if Auto Changeover is enabled If dehumidification is enabled selections are shown on next page L9 Programming Installer Settings conr Setting Thermostat Installer Options continued Installer Options Factory Default Options Comment 24 Compressor BALCH BALCND Scrolls between NO no lockout Balance Point BALC 10 and 10 to 50 F 12 to 10 C to sac 50 set Compressor Balance Point Only available with multi stage heat pump and outdoor sensor connected 25 Auxiliary Balance BALANO BALA NO Scrolls between NO no lockout Point BALA IG and 70 to 40 F 21 to 4 C to set pate HO Auxiliary Balance Point Only available with multi stage heat pump and outdoor sensor connected 26 Outside Air Intake Aone DA none DA Available only in Business Mode Options ecan GA and if Dehumidification Fan Speed 20 DA Control is set to NO Selects Outside Air Intake Options of None
Download Pdf Manuals
Related Search
Related Contents
Manual do Usuário Medidor de Vibração CHANNEL INTELLIGENCE Adapter "取扱説明書" ASUS RT-AC56U TR7967 User's Manual Verbatim 3.5'' HDD 640GB WJ-NT104 Manual Paragraph Styles Reference (delete when done) Ferris Industries BGF48KAV15 User's Manual Q uadro com ando program m abile Istruzioni d`uso ed avvertenze Copyright © All rights reserved.