Home
620203- PD60-LAR manual-english
Contents
1. should be clear and free from obstacles which will block the air flow for the unit 5 Clean the filtering net once every two weeks never use alcohol the Kyoto Protocol gasoline on or hot water with a temperature of 40 degrees C Its total global warming potential GWP is 1975 This marking indicates that this product should not bedisposed with other household wastes throughout the EU To prevent possible harmto the environment or human health from uncontrolled waste disposal recycle itresponsibly to promote the sustainable reuse of material resources To returnyour used device please use the return and collection systems or fF contact theretailer where the product was purchased They can take this product forenvironmental safe recycling SALVADOR ESCODA S A once 392 pl 2 08025 Barcelona Tel 34 93 446 27 81 Fax 34 93 446 27 96 www salvadorescoda com export salvadorescoda com
2. MUNDESICLIMA M60 N DEHUMIDIFIER USER MANUAL SAFETY INFORMATION 11 12 Please read the operating instructions carefully before using your dehumidifier for the first time and keep them in a safe place Never immerse the appliance in water or other liquids Never operate the appliance if a cable or connector has been damaged after appliance malfunction or if the appliance was dropped or otherwise damaged Electric appliance may only be repaired by qualified personal improper repair work can be a source of considerable danger for the users Children are not aware of the hazards of electric appliance Therefore never allow children to manipulate electric appliance unless properly supervised Disconnect the appliance from mains power whenever it is not in use before relocating it and before cleaning Operate the appliance only at the voltage specified on the type plate Use the appliance only in the household and only for the purpose it was designed for Do not place heavy objects on the appliance To prevent spillage empty the water tank before relocating the appliance Do not tip the appliance to any side as escaping water could damage the appliance This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsibl
3. e for their safety Children should be supervised to ensure that they do not play with the appliance 13 When the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 14 The devices should be installed at minimum distant of 50CM from the wall or other obstacle 15 Unplug the appliance before cleaning 2 OPERATING INSTRUCTIONS 1 Control panel 2 Air outlet 3 Handle 4 Front panel 5 Back panel 6 Water out hole 7 Water tank CONTROL PLATE DESCRIPTION O O O TANK FULL OPERATION DEFROST OPERATION INSTRUCTION Starting the unit 1 Firstly turn the humidity control switch to the OFF position 2 Plug in the dehumidifier 3 Turn on the humidity control switch to right side and turn the same switch to the reading of the desired humidity 60 in general as shown on position 4 Turning off the unit 1 Turn the humidity control switch to the left side to the OFF position and the power supply is cut off and the unit stops in operation 2 If the dehumidifier is not in use for a long time please disconnect the power cord plug from the outlet PRECAUTIONS 1 The dehumidifier shall not operate if the humidity setting is higher than the ambient humidity 2 Drain the water in the water storage tank when the water in the tank is full and the water level indicator light illuminates And then install
4. the empty water tank back to its position so the unit can continue its operation 3 When the unit stops you have to wait for 3 minutes before you can restart the unit to protect the compressor from damage 4 The humidify and its related position number on the humidity control switch CONTROL SWITCH APPROXIMATE POSITION NO HUMIDITY SETTING 5 The operational temperature range for this unit is 5 32 C 6 If the dehumidifier does not start the operational light does not illuminate or the dehumidifier makes intermediate stop on unknown reasons please check the plug and power supply for poor connection If the plug and power supply are in normal condition wait for 10 minutes and restart the unit because take about 10 minutes to reposition If the unit still does not starts in 10 minutes please contact your local distributor service station for repair 7 When the dehumidifier is in operation the running compressor will produce heat and make the room temperature higher This is normal condition 8 defrost light on is to indicate the operation of defrost is start During this operation mode compressor will be switched off and air motor will be turned on DRAINAGE INSTRUCTION The extracted water can be collected by water tank or drained continuously with a PVC hose not available USE OF WATER TANK and the fan will stop operation please empty the water tank 1 Remove the water tank as Fig 01 and empt
5. y it 2 Insert gently the water tank into the unit reach to its original position CONTINUOUS DRAINAGE 1 When you want to use this function please Pull out the water tank and plug the discharge water pipe in Water out hole See Fig 02 replace the water tank into the unit then you can operate the unit Filter Removal e he filter can be removed from its slot by gripping the filter handle and sliding it out from the back of the appliance e Every 2 weeks remove the filter and clean it with warm water below 40 Filter Handle Allow it to dry naturally and then Filter VAAN Vat AIK AN NNN SA VAAN replace AWN Maintenance Instruction SPECIFICATIONS 1 The unit is not allow to be located on the floor of soft and uneven surface when the unit is in operation to avoid occurrence of vibration and noise POOU ERN SPECIFICATION 2 Never insert any slim rod and hard object into the unit body to avoid occurrence of hazard or unit failure RATED POWER 1150W 3 During power off or when not in use for a long time please pull out the INPUT EN60335 power cord from the outlet RUNNING CURRENT ff NET WEIGHT 23Kg aD MOISTURE REMOVAL oea 30 CRH 80 CABINETDIMEMSION 481W x 286D x 628H TEMP RANGE FOR USE 5 C 32 C 4 Fora better dehumidifying effect the areas in front and rear of the unit CE N 842 2006 R410A is a kind of fluorinated greenhouse gases covered by
Download Pdf Manuals
Related Search
Related Contents
Baixar o Arquivo - Módulo de Consulta dos Magistrados Sportline Series - Universo Sniper Airsoft MANUALE USO E MANUTENZIONE DEL - Cnc Samsung SGH-E360 دليل المستخدم Herkules 2 Lancelot User Manual I-Tech Company SLR-CH-470-R User's Manual LG DH4220S home cinema system Pioneer DEH-9300SD User Guide Manual - CaRadio Copyright © All rights reserved.
Failed to retrieve file