Home
Product User Manual
Contents
1. tured light exceeds the selected intervention threshold in this way we will have a reference to the current light conditions to establish the desired one PROGRAMMING KEYS AND INDICATOR LED SEL Key selects the type of function to memorise the choice is indicated by the flashing of the LED By repeatedly pressing the key it is possible to position oneself on the desired func tion The selection remains active for 15 seconds displayed by the flashing LED after which the control unit returns to the original status SET Key carries out programming of the function chosen with the SEL key Indicator LED LED on option memorised LED off option not memorised Flashing LED option selected LED On Impulse 1 sec Timer ON Relay Output NC LED Reference LED Off Monostable Timer OFF Relay Output NO 1 MONO 2 TEMP 3 CMD 1 MONO Monostable Operation Impulse 1 sec The control unit is supplied with the Monostable operational mode enabled MONO LED OFF meaning that the relay will activate every time that the sensor determines that there is no light and will deactivate in the presence of light When needing an Impulse type of functioning meaning that the relay is only activated for one second each time that the sensor determines that there is no light programming must be completed in the following way position the SEL key on the flashing of MONO LED then press the SET key the MONO LED will simultane
2. MSC50 Easy Light twilight switch makes it possible to carry out con trols without having light there are various operational modes and types of power supply Mod MSC50 Mod MSC50 230V TECHNICAL DATA 12 24 VAC DC 230VAC Power supply Power supply Power supply See model Max consumption OW Relay Contact 30VDC 10A Working temperature 10 55 C Dimensions 80x54x38mm Protection rating IP 54 amp LIGHT MONG TEMP LMC e e SEL SET VR CONNECTIONS OF THE CN1 TERMINAL BOARD 1 Power supply 230VAC 2 Power supply 230VAC CONNECTIONS OF THE CN2 TERMINAL BOARD Power supply 24 VAC DC Power supply OV Power supply 12VAC DC Relay Contact Output Relay Contact Output hore ee le INITIAL FUNCTIONING CONDITION The device makes it possible to activate controls based on the light detected through the integrated sensor Sensor sensitivity can be modified using the VR1 trimmer present inside of the device By using the SEL and SET programming keys it is possible to select different types of operation In the default configuration the device is set at an intermediate sensitivity to light through the VR1 trimmer and Monostable functioning with NO contact output ADJUSTING SENSITIVITY TO THE CAPTURED LIGHT The device makes it possible to adjust Sensitivity of the light captured through the VR1 trimmer The switching on of the LIGHT LED on the device indicates that the intensity of cap
3. ay attention while making holes in the outside casing when passing cables for connection and power supply and assem bling the cable glands that everything is installed in a way that keeps IP protection characteristics of the panel un changed as much as possible Pay careful attention when fastening the cables so that they are anchored in a manner that is stable The back casing is not equipped with suitable predisposi tions for fixing to a wall predisposition for holes for fixing us ing anchors or holes for fixing using screws Plan and im plement necessary solutions to achieve an installation that does not alter the IP protection IMPORTANT FOR THE INSTALLER ATTENTION keep this instruction manual and respect the important safety prescriptions contained herein The non com pliance with the prescriptions may cause damages and serious accidents The device must never be used by children or persons with reduced physical psychological abilities unless supervised or trained on the functioning and the use modalities Frequently examine the plant to detect any signs of damag ing Do not use the device if a repair intervention is necessary Attention All operations which require the opening of the casing cables connection programming etc must be carried out by expert personnel during installation For any further operation which requires the casing to be re opened re programming repair or installation amend
4. ments contact the after sales assistance STATEUROP declares that the products MSC50 MSC50 230V comply with the specifications of the Directives LVD 2006 95 EC EMC 2004 108 EC CE 1 Rev 1 0 07 05 2010
5. n needing an inverted mode of operation with the control output set at Normally Closed proceed as follows position the SEL key on the flashing of LED CMD then press the SET key the LED CMD will simultaneously switch on perma nently and the programming is completed Repeat the proce dure to restore the previous configuration RESET Rev 1 0 07 05 2010 In case it is necessary to reset the device to default factory set i indi tings press the SEL and SET keys together so that all indica tor LEDs switch on and then immediately off at the same time Stateurop Mea Fani HH STATEUROP sistemas automatizados para eur i J i op IMPORTANT FOR THE INSTALLER Rua do Sobreiro Lugar do Pinheiro Rio C vo St Eug nia Apto 50 Moy O las D E O D o w SS a B i O The product does not have any type of isolating device for the 230 Vac line It will therefore be the responsibility of the installer to arrange an isolating device inside the plant It must be positioned where it can be protected from accidental clos ing according to that prescribed in point 5 2 9 of EN 12453 Wiring of the various electrical components outside of the product must be carried out in compliance with that pre scribed in Standard EN 60204 1 and its amendments at point 5 2 7 of EN 12453 Power supply and connection cables must be fixed using the cable glands that can be supplied as an optional P
6. ously switch on permanently and the programming is com pleted Repeat the procedure to restore the previous configura tion 2 TEMP Timer Function enabled disabled The control unit is supplied with the Timer functioning disabled TIMER LED OFF When the device needs to be used with the timed function meaning that the control relay is active for the programmed amount of time after the sensor has been activated Proceed as follows position the SEL key on TIMER LED and press the SET key to start programming at the same time the TIMER LED will start to double flash every double flash of the TIMER LED corresponds to an increase of 30 minutes up to a maximum of 12 hours 24 double flashes press the SET key until the desired time is reached at the same time the selected value is saved and the TIMER LED will stay on It is possible to repeat the operation in case of an incorrect programming Displaying the programmed Time When verifying the previously programmed Time it is possible to display it in the following way with the SEL key position yourself on TIMER LED the LED will start to double flash for the number of times equal to the Time programmed in the memory every double flash of the TIMER LED corresponds an increase of 30 minutes example 4 TIMER LED flashes 120 minutes 3 I CMD Inversion of NO NC control functioning The control unit is with a Normally Open output operational mode LED I CMD OFF Whe
Download Pdf Manuals
Related Search
Related Contents
APW Wyott GGT-18H User's Manual ATN Diffusion LPF SA IPCMonitor User Manual vibra trainer fit / vibra trainer fit pro modelo: se211 Azur 540A V2 1380 Ko Virtu USA GD-50072-WMRO-ES Installation Guide 住宅用火災警報器 FIREXマルチタイプ 型式:4066CL 製品仕様 Copyright © All rights reserved.
Failed to retrieve file