ProSoft i-View User Manual

image

Contents

1. RLXIB IHN Industrial Hotspot ER T B Controller PC with all required software ProSoft Technology Inc Page 75 of 106 September 29 2011 Network Settings for Local Access User Manual ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 7 4 PLC Settings for Local Access For EIP Native protocol and Allen Bradley controllers use the RSLogix 5000 tool to set a fixed local IP for the PLC in the ethernet Module Properties dialog box General Connection RSNetwors Module Info fj IP Address 192 168 1 39 Must Match IP Address on General T ab 255 255 255 0 Gateway Address 192 168 1 1 Primary DNS Server Address nm Secondary DNS Server Address EB NOS ME Enable Bootp Subnet Mask Domain Name Host Name Select Port Speed 100 Mbps Y Current Port Speed 100 Mbps Select Duplex Full Duplex Current Duplex Full Duplex Changes to Port Speed and Duplex require module reset Enable DHCP DHCP must be configured to return a fixed address MV Enable DNS Auto Negotiate Port Speed and Duplex Status Running Refresh Set For EIP PCCC protocol use Allen Bradley s RSLogix 500 tool to set a fixed local IP for the PLC on the Channel Configuration panel For PLCs or devices based on the Modbus TCP IP protocol consult the relevant vendor documentation to know how to set ports and addresses
2. If you use a lot of boolean tags consider boolean arrays on EIP Native or bit access on registers on other protocols Bit readings on registers are faster because you get several boolean values with a single register read Finally if you are concerned about performance or you are planning a really big project do some planning following the above recommendations before even starting your project Then profile periodically your project for performance as you are developing it and adding more rows to it ProSoft Technology Inc Page 87 of 106 September 29 2011 Security ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Page 88 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 Pre installed Examples User Manual 10 Pre installed Examples In This Chapter DataTypesModbus csv DataTypesModbusWSource csv EIP TAG Examples csv EIP_PCCC_Examples csv PagesExampleModbus csv PagesExampleEIP csv StylesExampleModb Csv ssssseeeeeneeem enne StylesExampleEIP PCCO csv ssssseeeeemnennennennn AlarmsModbus CSv ivei e a a nnne ener nnn AlarmSEIP_PCCC CSV ccccccccceesceceeeeneeeeeeeeeeeseneeeeessaeeeessneeeesenseeees ColorfulControlsModbus CsSv eeeeeeneeeeenenen nennen ColorfulControlsEIP PCCOC csv
3. ssesssseeeeeeeennemee Formula ONE QSV inset nere ditior to devi EY doe Veg ProSoft Technology Inc September 29 2011 Page 89 of 106 Pre installed Examples User Manual ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 The ProSoft i View application comes with pre installed examples that can be used directly or downloaded to a PC to be used as templates for your own development The following examples are provided PROTOC OL Modbus TCP IP DataTypesModbusWSour MS Modbus ce csv Excel TCP IP EIP_TAG_Examples csv MS EIP Nativ Excel e EIP PCCC Examples cs MS EIP PCC V Excel C PagesExampleModbus cs MS Modbus V Excel TCP IP PagesExampleEIP csv MS EIP Nativ Excel e StylesExampleModb csv MS Modbus Excel TCP IP StylesExampleEIP PCCC MS EIP PCC CSV Excel C AlarmsModbus csv MS Modbus Excel TCP IP AlarmsEIP PCCC csv MS EIP PCC Excel C ColorfulControlsModbus c MS Modbus sv Excel TCP IP ColorfulControlsEIP_PCC MS EIP PCC C csv Excel C Formula ONE csv MS none Excel COMMUNICAT ION ATTRIBUTES NO YES NO NO NO NO NO NO NO NO NO NO NO ALAR ES MS YES NO YES NO dis adii m m YES NO YES NO YES YES YES YES YES NO YES NO YES YES EXPRESSIO NO NO NO NO NO NO NO NO NO NO NO NO YES Page 90 of 106 ProSoft Technology Inc September 29 2011
4. Mid Level Set Point L 350 Level at which pump 1 stops Low Level Set Point L Level at which pumps start 100 7 VALVE 1 Limit Switch Valve 1 Completely Open OPEN Limit Switch Valve 1 Completely Closed OFF Man Auto OFF Manual Open will stop process The following examples demonstrate several ways of displaying elements on the Home view list ProSoft Technology Inc Page 11 of 106 September 29 2011 User Interface Elements ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 An Alternate way to switch a bool Scalar Value Default Button Style Scaling Formating You can use a button instead Scaled fi Formated ud Wgt 3 399 kg Custom Button Style Bar Style Weight 3 399 kg And add a custom text on it I ail BOOL Examples Slider Style 3399 g Susi NEED a Format in Writable Value 3359 Conveyor Control Writable value with bezel and format g Push to move Right Writable Value Conveyor Control LEFT Writable value with no style 3399 Push to move Left Default Style Engine Start Switch TM Values are displayed this way with no style 3399 Tap to start stop Engine Default Style REAL value 35 0534 1 Xt LOOKUP gt tyie A real value with no style Bezel Style Everything oe Writable value with bezel style 35 0534 Human presence detected in the e 2 restricted area TE iPod 21 48 R TANK Output Flow
5. String or any object converted YES using to s Unsigned decimal integer YES Hexadecimal integer e g 39ff YES Hexadecimal integer e g YES 39FF For the meaning and possible contents of the optional flags width and precision fields refer to the sprintf specification http www cplusplus com reference clibrary cstdio sprintf Note that since there is no need for it the ength field is not available The if then else clause and the ternary conditional operator Two forms of conditional execution are provided The ternary conditional operator provide conditional execution of expressions Its syntax is the following expr expr1 expr2 Returns expr1 if expr is not zero true or expr2 otherwise The if then else clause provide conditional choice of expressions It is used as follows if expr then expr1 else expr2 end Executes expr if expr is not zero true If expr is zero false expr2 is executed instead Items between brakets are optional ProSoft Technology Inc Page 55 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 The if then else clause 2 differs from the ternary conditional operator 1 in the following ways 1 executes when any of expr expr expr2 generate a change event The result is always updated and will be consistent with the values of expr expr and expr2 at all times
6. 3 1 Data Sources Created in Excel ssssssssssssssseeeeeeeeneeneen nenne 15 3 1 1 Specification of Variable Names Column A 16 3 1 2 Variable Types COlUMNiB rettet tret Hte ter rite tenista inet 18 3 1 3 Variable Addresses Column C ssssssssseseseeeeeeeeeeeenere nne 20 3 1 4 Attributes ColurmniB eiit ter ceteri in oed re cla e Re utn 24 3 1 5 Attribute Scope and Type ta Ree Hr E e RE Hue de RU ut 25 3 1 6 Tag Attributes c 25 3 1 7 Global AHFIDUEeS iiie tet it eet tee d ek eite it ehe Lr gate eine a eek Err ER 33 3 1 8 Pages Sections Rows and Data Sources sssssssssssssseeeee 36 3 1 9 LOOKUP MI p lo EE 37 3 1 10 Alartmns iint et nete hate e oreste edite i aae edunt Satan as Poco edu 39 3 1 11 Gommeritsin Data SOUIGCES serere eeraa teet ie tori goto pei eai eden iau e daga 40 3 1 12 Specification of Communication Protocol sesssssseeeeeeene 40 3 1 13 EXPOSSIONS mE 46 3 2 Rockwell RSLogix 5000 as a Data Source Generator 60 3 2 1 Building a Project in RSLogix 5000 sse 60 3 2 2 Exporting Controller Tags from RSLogix 5000 sess 60 3 3 Editing Source Files in a Text Editor 61 ProSoft Technology Inc Page 5 of 106 September 29 2011 Contents ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 4 File Import into ProSoft i
7. 34 502 FINS TCP 9 Connections wv iPod 9 52 Connections Source Info DataTypesModbusWSource csv Protocol Modbus TCP Tags 27 Local Host 192 168 1 34 502 Remote Host remote hostname com 502 SSL Enabled No Status Info Connections ProSoft Technology Inc September 29 2011 Page 69 of 106 Connections ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Page 70 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application User Accounts Version 2 0 2 User Manual 6 User Accounts In This Chapter Restrictions for Non Administrator Users eese 72 Managing Accounts sessssseseeeeeneenm eene menn 738 User accounts allow the administrator to determine which process variables will be visible or editable for a particular use or user depending on specific variable attributes Relevant attributes for this purpose are Access and Write access See Attributes page 24 Only users who have an access level equal to or greater than the one set for a particular variable will be able to view or edit it The purpose of user accounts is to make it possible for a PLC program developer or integrator to create a pre configured solution for a particular customer and limit that customer s ability to change the application An end
8. 87 DataTypesModbusWSource csv 88 E Editing Source Files in a Text Editor 57 EIP PCCC Examples csv 90 EIP TAG Examples csv 89 Event Driven Architecture 42 Example 40 Exporting Controller Tags from RSLogix 5000 56 Expressions 42 F File Import into ProSoft i View 4 59 File Server 10 Files 10 Formula ONE csv 99 G General Aspects 7 Global Attributes 33 H Home 10 Home Tab Bar and Navigation Bar 13 How to Use ProSoft i View in Five Simple Steps 4 K Keep Connected 80 L Lookup Tables 19 37 M Main Features 4 Managing Accounts 69 Multiple Range Lookup Tables 38 Multiple User Lookup Tables 38 N Network Settings for Local Access 4 71 Network Settings for Remote Access 75 Note on EIP Native Communication Protocol 22 0 Operators and Operator Precedence 47 Other Files Supported by ProSoft i View 62 P Page Section and Ord Attributes 36 Pages Sections Rows and Data Sources 27 36 PagesExampleEIP csv 92 PagesExampleModbus csv 91 Performance Considerations 40 PLC Settings for Local Access 72 Pre installed Examples 85 ProSoft i View Settings for Local PLC Access 73 ProSoft Technology Product Documentation 2 Q Quick Start 3 R Restrictions for Non Administrator Users 68 Rockwell RSLogix 5000 as a Data Source Generator 56 S Security 77 Settings 10 Source Files Supported by
9. Data Source Files In This Chapter Data Sources Created in Excel ssssssseen 15 Rockwell RSLogix 5000 as a Data Source Generator 60 Editing Source Files in a Text Editor ssseees 61 Source files contain information that ProSoft i View needs for visualizing PLC process variables as required by users ProSoft i View accepts csv files created in Excel or Open Office For some PLC brands it also supports files directly created from PLC vendors development tools such as Allen Bradley RSLogix Source files imported into ProSoft i View are shown in the Files tab under the Sources section One or more sources can be selected and variables from all of them will be displayed depending on current user access level DataTypesModbus csv 25 KB DataTypesModbusES csv 25 KB DataTypesModbusWSou 26 KB DataTypesModbusWSou 2 6 KI EE FinATank exe FillATankWSource cxr Each source refers to a single PLC but several sources can refer to the same PLC All sources that point to the same PLC are automatically joined into a single connection Note Be sure you have at least one selected source or ProSoft i View will not display any variables 3 1 Data Sources Created in Excel You can use Excel or Open Office to compose a data source file for ProSoft i View The file must be exported or saved in CSV format ProSoft Technology Inc Page 15 of 106 September
10. Native SMValidationTag Any INT value This tag must be present in order for ProSoft i View to communicate Set to 0 initially to avoid having to enter it in ProSoft i View during development stages EIP PCCC N98 0 Any INT value This tag must be present in order for ProSoft i View to communicate You may need to create a Data File number 98 of type Integer with at least 1 element The Validation Code feature is not available for Modbus TCP IP due to the great number of Industrial devices supporting this protocol which makes it impractical to establish a general way to implement such a feature Validation codes are entered in the relevant fields of ProSoft i View s Connections view ProSoft i View will store and remember codes between connections but it will reset them to 0 for connections that changed as a result of source change iPod 10 05 Connections Communication 9 Monitor mm Connections started 4 linked 4 failed 0 Connections Note that ProSoft i View will always perform this security check There is no way to disable or avoid it However you can set a custom validation tag Page 82 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Security Version 2 0 2 User Manual 9 1 1 Custom Validation Tag If the default validation tag interferes with your project you can set a custom one with the validation tag attribute When yo
11. ProSoft i View Mobile Process Monitoring and Control Application Pre installed Examples Version 2 0 2 User Manual 10 1 DataTypesModbus csv This example shows the supported data types with a focus on Modbus devices This file was created in MS Excel and does not require any program in the PLC iPod 21 28 lt LECE UINT HOLDING REGISTER HR00005 UINT UINTValue HR00005 UINT 12345 DINT HOLDING REGISTER DINTValue_ReadOnly HR00006 DINT 987654321 HAOUR OE 987654321 mae NOU naaar esten 123456789 HR00008 UDINT HR00010 REAL 3 14159 REALValue HR00010 REAL 3 14159 ProSoft Technology Inc PSOE September 29 2011 Pre installed Examples ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 10 2 DataTypesModbusWSource csv Same as the previous example except that it contains communication attributes Page 92 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 Pre installed Examples User Manual 10 3 EIP TAG Examples csv The purpose of this example is to demonstrate a set of valid symbolic tag names used in Allen Bradley Logix controllers iPod 21 52 E IP TAG examples E IP TAG i m rond EUM DU 31 prid 122 Ee mener 32 Int value 13 MO ure TET 2 71828 repr qe 67 struci wg aera el 7 OFF Emeri PRE 1000 TL Nn E ber 0
12. Tags from RSLogix 5000 Unfortunately RSLogix does not provide a way to select and export selected tags to a file However it is possible to do a bulk export containing all global controller tags In RSLogix right click CONTROLLER TAGS From the dropdown menu select EXPORT TAGS Controller Organizer J Controller My Controller a Z3 Controller Faull New Tag Ctl w i Power Up Hanc 53 Tasks Monitor Tags Z3l Motion Groups Edit Tags Trends Verify Data Types pea RSLogix will generate a special CSV file containing all global tags present in the project Tag source files generated in this way can contain attributes as described in Attributes page 24 If you need to specify attributes for ProSoft i View you can put them in the Description column of the Controller Tags view in RSLogix This is equivalent to filling column D on an Excel generated source Note Files with a CSV extension created by RSLogix as described in this section are structured differently from CSV files created in Excel as described earlier However ProSoft i View will recognize them as well Since RSLogix does not provide a convenient way to select a particular set of tags before exporting you may need to edit the exported file with Excel or a Text Editor to adapt it to your needs In this case you do not need to change its overall structure and format just eliminate redundant rows and you will be done Page 60 of 106 ProSoft Technolo
13. Version 2 0 2 Security User Manual 9 9 1 Security In This Chapter Validation CodeS a a nnne a nn nnn rna 81 Background Task Processing 84 ProSoft i View networking security is based on TCP IP technology and depends in part on the security features available in the router installed at the PLC location For local connections through WiFi security is provided by the wireless network security protocol in use WPA and WPA2 with a strong password is the recommended security protocol For remote connections an iPhone or iPod touch is able to make use of secure data tunnels by enabling VPN If your router supports L2TP IPSEC or PPTP then you will be able to create this kind of connection Most medium to high end DSL or Cable routers support at least PPTP VPNs Client connections are configured on the iPhone with the General Settings App Some routers can be loaded with a SSL certificate and be configured to bridge incoming SSL requests from the WAN to unencrypted TCP on the LAN side ProSoft i View supports TLS SSL encryption You can activate TLS SSL in ProSoft i View to provide communications confidentiality if your router supports SSL TCP bridging For most protocols ProSoft i View provides an independent way to protect users from undesired access by persons using uncontrolled ProSoft i View copies This is done by setting a Validation Code both in the PLCs and ProSoft i View which will prevent ProSoft i View from
14. View 63 4 1 Source Files Supported by ProSoft i View sssssssssssseeeeeeees 65 4 2 Other Files Supported by ProSoft i View sssssssseeeeeneenene 66 4 3 Custom Company Logis sisean ii anaa aa e a entente enne nre enne 67 5 Connections 69 6 User Accounts 71 6 1 Restrictions for Non Administrator Users seseeeennen 72 6 2 Managing ACCOUNTS 2t tette dei re pe b pp EO ee gv Pratt ges 73 7 Network Settings for Local Access 75 7 1 PLC Settings for Local Access c ccccscceeeeeeeeneeeeeeeeeeaeeseaeeeseaeeseaeeeseaeeseneeeseeessaees 76 7 2 ProSoft i View Settings for Local PLC Access sssssssseseee 77 8 Network Settings for Remote Access 79 9 Security 81 9 1 Validation G odes hes den etenim ot vitrine vereor Es e 81 9 1 1 Custom Validation Tag sess siia P n t ERR EP a RR EHE EUER REDE Ee aaaea 83 9 2 Background Task Processing 84 9 2 1 Keep Gontnected inti re RE EUR ERROR PIN Ipae 84 9 3 PerfOrmariCozi acit ER UB REGERE EBD E 86 10 Pre installed Examples 89 10 1 DataTypesModbus Csv eea E OE EE EA nennen nennen nnne 91 10 2 DataTypesModbusW Source Csv ssssssssssseeeee eene enne 92 10 3 EIP TAG Examples CSV 5 e rere rt tle rire Ro ran eur ete Heike hieu RA EP conveys 93 10 4 EIP_PCCC_Ex mpleS CSV cccccccccssseccecseneeeeeesneeeesssaeeeesesaeeeeseseeeessseeeesssneeeeeeeas 94 10 5 PagesExampleModbus Csv ececceeceeeeecesenneeeeeen
15. allowing for practical ways to represent and dealt with several data types and formats with great flexibility ProSoft i View supports most operators including all common Logical Arithmetic and Comparison operators as well as commonly used Ruby functions and methods Support of Ruby expressions in ProSoft i View is a subset of the Ruby language Expressions are not and do not pretend to be a complete implementation of Ruby In some cases we provided a single way to accomplish something that can be done in several ways on Ruby and in other cases we integrated several functionalities in single methods instead of implementing all of them So it is important to refer to this manual if you are also using a Ruby tutorial to determine what it is actually supported on ProSoft i View and which behavior differences may apply For those who already used Ruby one of the most obvious differences between pure Ruby and ProSoft i View is treatment of boolean values Ruby treats everything as objects including numbers while ProSoft i View keeps the traditional C like behavior For example in Ruby any number used in a boolean expression is a true value even if it holds zero ProSoft i View on the other hand will still interpret O zero as false and non zero as true in the traditional sense of earlier programming languages and hopefully in accordance to what PLC programmers would expect or feel more natural NOTE If you are not familiarized with
16. as listed in http www wS3schools com css css colornames asp Colors can also be given by RGB value in hexadecimal format The Color bounds attribute determines when the color will be applied Supported values also include TextDefault BarDefault and DefaultGreen which are the colors used by default on texts bars and boolean tags Examples color z red color z olive color FF3300 Numeric Expression The color attribute used in this way expects a 32 bit integer value containing the RGB color coordinates in the three lower significance bytes with the B value in the least significant byte The method SM color can be used for convenience to generate a color from its RGB coordinates or name Indicates an alternate color to apply The Color bounds and Tint color bounds attributes determine color application ranges Refer to the Color attribute for valid color values Example tint color red A two element array in the form low high where low and high are numeric values determining the range of values for the tag where the color will NOT be applied also known as an exclusion range Examples color bounds z inf 50 This will exclude tag values below 50 from displaying in the color set in the Color attribute Therefore tag values will be displayed in the specified color when they are above 50 color bounds 50 50 Tag values from 50 to 50 will be excluded from displaying in the color set in the Colo
17. be excluded from the Tint color color so the tint color will show for values from 50 to 20 and from 20 to 450 For boolean tags color bounds and tint color bounds have predetermined values You can simply use tint color to display a color for both Off and On states while color will supersede the color for the On state blink Expression Numeric Expression Will cause any non writable tag booleean to blink on the interface when the value assigned to the attribute is not zero true blink bounds Value list A two elements array in the form low high where low and high are numeric values determining the range of tag values where blinking will NOT be applied If specified on a read only tag the tag will visually blink with a period of 1 second for the values not in the specified range Example to set a tag to blink always blink bounds z inf inf Example to set a tag to blink when its value goes below 10 or above 10 blink bounds z 10 10 Example to set a boolean tag to blink for the On state blink bounds z 0 0 plot color special text Determines the color to be used in trend graphs when plotting this tag If omitted a sequential color is chosen automatically ProSoft Technology Inc Page 29 of 106 September 29 2011 Data Source Files User Manual ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 expression expression boolean special text Specifies a
18. file created in Step 2 into ProSoft i View See File Import page 63 Set the PLC IP address in ProSoft i View if you did not do so in Step 1 See Network Settings page 75 Monitor process variable states and values from anywhere with mobile or WiFi access ProSoft i View Mobile Process Monitoring and Control Application Contents Version 2 0 2 User Manual Contents Your EeedbackiPl6ase cc oe to tette tiet t ilta Le EC LM se 2 Howto Contact UJS iind Ee Re cs RESX CR RENTEN NENTGRAYRARERBRRASNEKERR VE ARERRE ERE SRN RA REB soues RENI REPRE NR NTUSRA EA RE RRa cane 2 ProSoft Technology Product Documentation stets 2 Quick Start 3 What is ProSoft EVIeW s eit iis here RED e ge e AREE Rene ERST cede enean NIAE anre ERA NR E 3 Mali EeatUl6Sx 2 teen vierte vitii vitate ee Uii E Po cL LL Lari 4 How to Use ProSoft i View in Five Simple Steps sssssssssssssseeeseeeeeeneneennns 4 1 General Aspects 7 1 1 Supported Protocols ianen eea aei ie n Le Reit ee eevee dice cu 8 2 User Interface Elements 9 2 1 Tabbed Interface sini i ee ea eee ei core doe dde ccu edd 10 2 1 1 S cC 10 2 1 2 EI ESI 10 2 1 3 gil m 10 2 1 4 Connections wes ERE 10 2 1 5 alere c P Ec 10 2 2 Variables in ProSoft ViSW sisena eea E ARRE eene enne nennen 10 2 3 Home Tab Bar and Navigation Bar sesseennm e 12 2 4 B ttom Ene vpP E 13 3 Data Source Files 15
19. is and will continue polling PLCs even when the device is locked This is intended to help keep alarms and graphs updated but it may have a negative impact on battery life When OFF ProSoft i View will close any open connection when another application becomes active or the device goes to the locked state either by the Auto Lock timeout or by pushing the bottom on the edge This will prevent excessive battery drain and may reduce carrier fees in case of cellular remote connections When the device is unlocked and ProSoft i View becomes active again communications with PLCs will be restarted Page 84 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Security Version 2 0 2 User Manual Background Process When ON the application will continue running in the background for a finite period of time while other applications are active making it possible for alarms and graphs to keep updating and enabling local alarm notifications while the user is performing other tasks When OFF the application will not explicitly start a procedure to run in the background and local notifications will be disabled However given how the iPhone iOS behaves the application may still be running in the background for an undetermined period of time if enough resources are available or the user does not explicitly switch to a different app The maximum time applications are allowed to ru
20. of characters the string actually holds This is particularly notorious when storing Chinese or Japanese strings in PLCs The UTF 8 encoding for instance can use up to 6 bytes per character in a PLC However this does not affect how strings are allocated in ProSoft i View or the behavior of String methods and operators in expressions since these always refer to actual characters and actual character lengths regardless of encoding Of couse if you only use English or ASCII characters with an encoding that is backward compatible with ASCII or you use the Latin1 encoding only one byte per character will be allocated in your PLC to store strings ProSoft Technology Inc Page 45 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 3 1 15 Expressions Expressions are allowed on several attributes and provide an advanced way to customize various aspects of the interface and behavior of ProSoft i View projects Expressions allow for combining tags with operators to produce custom results Tags are referenced in expressions by using their names as entered in Column A There are also several system variables that can be used for special uses Event Driven Architecture Expressions in ProSoft i View are stored in a compiled form and are executed by an event driven engine The execution engine keeps expression reference information in a way that valu
21. performed for bit or bitwise operations on numbers and indexed access to string or array elements In other cases you can use the to i method to explicitly get the integral part of a numeric value according to your needs Constant numbers can be represented with optional decimal point and a base 10 exponent Additionally hexadecimal and binary notations are supported by using the Ox or Ob prefixes The special forms true false inf and inf are supported as well Examples 1 42 decimal representation 1 1666e 2 decimal representation with exponent OxeOaf hexadecimal representation 06011011101 binary representation true same as 1 false same as 0 inf very big negative number inf very big positive number Strings Strings are arbitrary sequences of characters that are manipulated as a whole Strings can be read from or written to PLCs Several operations can be performed on strings such as concatenating splitting or substring extraction by using the appropriate operators or methods String literals are represented enclosed in double quotes ProSoft Technology Inc Page 49 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Example This is a literal string InckperHeie naruuku er VYD IARR Arrays Arrays are indexed collections of objects Each element in an array is associated with and referred to b
22. user does not usually need to change communication settings or modify attributes This is normally a developer s responsibility Therefore by setting user accounts and keeping the administrator password private a developer can choose to provide customized safe access to a monitored process User accounts can also help prevent unauthorized persons from interacting with remote processes by getting physical access to an iPhone with ProSoft i View installed Two accounts are set up by default with the following names passwords and access levels USER PASSWORD ACCESS admin 9 0 The administrator account allows you to create additional accounts with intermediate access levels as well as to select active accounts It is strongly recommended that you change the default passwords once you have a running configuration in place Note that there is no way to retrieve a lost password The only way to recreate the original passwords is to remove ProSoft i View from your iPhone or iTunes and reinstall from the App Store Be sure your source files are conveniently backed up in case you should ever need to do this administrator ProSoft Technology Inc Page 71 of 106 September 29 2011 User Accounts User Manual ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 6 1 Restrictions for Non Administrator Users Only the administrator account has full access to all t
23. value to write on the related tag based on the result of an expression see Expressions Note that the value attribute has a slightly different behavior for Internal tags than for regular PLC tags For PLC tags the result of the expression is first written to the PLC already converted to the relevant type and appropriately limited and descaled according to the bounds and scale attributes On reading the tag value is scaled back to the engineering unit As a consequence a tag may end having a slightly different value after that For example a Tag of type INT having scale 0 10 0 1 will become 1 2 when assigning 1 234 to it through a value change Of course the value in the PLC will become 12 due to the scaling and type conversion On PLC writes involving STRINGS implicit conversions will also be performed if possible For example the STRING 2 3 will be converted to the number 2 3 upon writing a REAL tag Similarly the number 2 3 will result to the sequence of characters 2 3 when writing to a STRING tag For INTERNAL tags no type or scale conversion is performed on the result of the value expressions Internal tags are just given the result of the expression as it evaluates Thus the scale and bounds attributes will have no effect Even the tag type is ignored to the effects of the assignment and the variable may hold a completely different type The following considerations also apply INTERNAL tags containing tag re
24. versions of Windows and Excel To do so follow the next steps Create a source file with Strings on your language using your default localized version of Excel as usual You must explicitly tell ProSoft i View the right string encoding of your file See below Export the file as usual Excel will use the default encoding for your localization mport the file in ProSoft i View ProSoft i View will use the explicit encoding to open the file Setting a Explicit String Encoding To set a explicit String Encoding for your file place the following command embedded in a comment on top of your file encoding string encoding For example to set Japanese you can write 3t encoding Japanese Win ProSoft Technology Inc Page 43 of 106 September 29 2011 Data Source Files User Manual ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 The following explicit string encodings are supported WindowsLatin1 UTF 8 MacRoman Cyrillic Mac Cyrillic Win Cyrillic SO Japanese Mac Japanese Win Japanese JIS Chinese Mac Chinese Win Chinese GB2312 Identifies the ISO Latin 1 encoding ISO 8859 1 This is the default Identifies the Unicode UTF 8 encoding Identifies the Mac Roman encoding Used on western localizations of Mac OS Useful when you use diacritic characters Spanish French German the degree simbol but you do not want to export your file as csv
25. windows Identifies the Mac Cyrillic encoding Identifies the Windows Code page 1251 Slavic Cyrillic encoding Identifies the ISO 8859 5 Cyrillic encoding Identifies the Mac Japanese encoding Identifies the Windows Code page 932 Japanese encoding Identifies the Shift JIS format encoding of JIS X0213 Identifies the Mac Simplified Chinese encoding Identifies the Windows Simplified Chinese encoding Identifies the GB_2312 Chinese encoding Strings in source files containing UTF 16 characters will be converted automatically to UTF 8 regardless of the encoding specified on the source file The UTF 8 encoding is a multibyte character encoding derived from UTF 16 Like UTF 16 it can represent every character of all languages but unlike UTF 16 it is backward compatible with ASCII using only one byte for representing ASCII characters Page 44 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual 3 1 14 Use of International Characters in PLC Strings You can store international Strings in PLCs with ProSoft i View just as easily as you do with ASCII strings ProSoft i View will use the source file encoding identification to decode encode strings onto raw bytes in the PLC When storing international Strings into PLCs you must expect the number of bytes used and thus the PLC string length to be larger than the number
26. 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Note CSV file format is not identical for all language localizations due to different use of delimiters ProSoft i View accepts any csv files in any of the supported languages but unfortunately this is not the case for MS Excel Consequently Excel may not correctly open the provided examples in the wrong language An Excel spreadsheet with variable specifications has four 4 columns and one row per variable E DataTypesModbus csv in BOOLValue M ord 02 section DISCRETE INPUTS in BOOLValue2 BOOL ord 04 section DISCRETE INPUTS BOOLValue_ReadOnly BOOL ord 205 section COILS label Default Read Only BOOL comment This is Coil 1 BOOLValue BOOL ord 206 section COILS write access 9 label Default Read Write BOOL comment This is Coil 1 too BOOLValue ReadOnly2 BOOL ord 207 section COILS label Custom Read Only BOOL on label z OPEN off label CLOSED BOOLValue2 BOOL ord 208 section COILS write access 9 label Segment Style BOOL style segment switch 9 BOOLValue3 BOOL ord 208 section COILS write access 9 label Default Button Style BOOL style button BOOLValue4 BOOL ord 208 section COILS write access 9 label Labeled Button BOOL style button button label START 2 in INTValue ReadOnly INT IR4 0rd 311 section INPU
27. 35 Amert ACG 223 Siue varind Meniberii 36 umeri EN c ea NOC DUCI 37 Gy TUE Varima 38 timer1 DN OFF TITULUS NN 39 TAG BOOL ProSoft Technology Inc September 29 2011 Page 93 of 106 Pre installed Examples ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 10 4 EIP PCCC Examples csv The purpose of this example is to demonstrate a set of valid symbolic tag names used in Allen Bradley Micrologix controllers Page 94 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Pre installed Examples Version 2 0 2 User Manual 10 5 PagesExampleModbus csv This example shows how to arrange tags in several pages It uses arbitrary Modbus Coils and Registers iPod 21 55 iPod gt 22 11 lt Overview Current Pressure Valve Control gt Pump 2 S 11 8 Current Pressure Process Data o Status Data Bearings Temperature Pump 2 39 7 Bearings Temperature ProSoft Technology Inc Page 95 of 106 September 29 2011 Pre installed Examples ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 10 6 PagesExampleEIP csv Similar to the previous example except that it uses EIP Native arbitrary tag names Page 96 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Contro
28. EIP NATIVE GLOBAL ATTRIBUTES TYPE DESCRIPTION controller slot number Identifies the slot where the Logix controller is located Default value is 0 connected mode number When true ProSoft i View will use connected boolean messaging instead of the default unconnected messaging for retrieving data from Ethernet IP enabled PLCs Look below for a discussion on what possible effects you might expect Default value is false ProSoft i View currently supports two EIP mechanisms to send commands to AB PLCs 1 For a Micrologix or SLC it will send PCCC commands DF1 embedded in EIP using a direct path 2 For a ControlLogix CompactLogix it will send native CIP commands using a Backpane Slot Number path The Backpane defaults to 1 and the Slot number is given in controller slot ProSoft i View uses CIP Explicit Messages to retrieve and send data from to Ethernet IP enabled PLCs Explicit messages can be sent unconnected or connected Connected messages require a Connection ID which is first asked to the PLC before sending other messages while unconnected messages identify the specific path to the destination in the same message Connected messaging is generally considered to be more reliable than unconnected because it reserves buffer space for the message and is therefore less likely to be blocked by other message traffic However if the TCP link between the message originator and the receiver is weak or prone to fail u
29. L s 15 4 Current Output Flow from Tank High Level Set Point L 510 58 Level at which pumps stop Mid Level Set Point L Level at which pump 1 stops 350 de Low Level Set Point L 100 70 Level at which pumps start iiD islelel BREE 2 3 Home Tab Bar and Navigation Bar The Home tab is where tags are displayed and where users can interact with their PLC variables Like most iPhone productivity applications the interface consists of a navigation bar on top and a tab bar at the bottom of the screen The standard iPhone status bar is always visible in ProSoft i View Page 12 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application User Interface Elements Version 2 0 2 User Manual Navigation Tank Level L Output Rew Us High Level Set Point T Mid Level Set Point L Taas Low Level Set Point L Limit Switch Limit Switch Tab Bar Tab Bar and Navigation Bar Hidden Tab Bar and Navigation Bar To optimize the available space on the Home tab view users can choose to hide the tab bar as well as the navigation bar as shown in the above screenshots You can perform the following interactions on these basic interface elements To hide or show the tab bar on the Home view use the HIDE BOTTOM BAR option on the Settings tab To scroll to the top of the Tags table tap on the status bar at the top of the iPhone Screen To hide o
30. Most attributes apply to a single tag They are referred to as tag attributes Others have a global scope within a source file and we refer to them as global attributes In the following sections all attributes are discussed individually Attributes by Type Attributes can hold a numeric value a text a special text or list of values depending on their meaning or purpose Numeric values are expressed as decimal numbers with optional decimal point and decimal digits if applicable to the attribute Several special values are provided for convenience true equals 1 0 false equals 0 0 inf represents a very large negative number inf represents a very large positive number Numeric values are expressed directly after the equal sign without quotation marks including the convenience values Examples write access z 3 word swap true Text usually represent text labels or fields in the application interface They are only required to be enclosed in quotation marks if they contain spaces or the semicolon character However to maintain readability it is advisable to always use quotation marks label z Main Run Stop Switch suffix 96 Attributes requiring a special text only accept specific pre defined text strings Valid texts vary depending on the particular attribute style z bezel format 4 2 Value Lists are used in cases where a single numeric value is not enough to provide the inform
31. OOL TAG ord 1 section GENERAL label Main Run Stop Switch comment z Main Process Start Stop access 3 write access 5 If you choose to create and edit your files using only a text editor the recommended way is to use tab delimited CSV formatting in which commas are replaced by tabs which ProSoft i View also supports This format is much more convenient to use in text editors because it is more readable and you can avoid all the double quoting hassle The row shown above will look as follows if tabs are used as delimiters instead of commas main switch BOOL TAG ord 1 section GENERAL label z Main Run Stop Switch comment Main Process Start Stop access 3 write access 5 ProSoft Technology Inc Page 61 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Page 62 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application File Import into ProSoft i View Version 2 0 2 User Manual 4 File Import into ProSoft i View In This Chapter Source Files Supported by ProSoft i View seseses 65 Other Files Supported by ProSoft i View sseeeee 66 Custom Company Logo sssseeeeeeneeeneee nennen 67 ProSoft i View features an embedded Web server to enable users to access to their f
32. Page 76 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Network Settings for Local Access Version 2 0 2 User Manual 7 2 ProSoft i View Settings for Local PLC Access ProSoft i View configuration depends on whether you have specified communication attributes for source files For more information see Attributes page 24 For sources without communication attributes ProSoft i View uses the default ports and addresses entered into the relevant fields in the Settings tab view Fill in the values you used for the PLC settings iPod 9 55 Settings Remote Port 9600 Modbus TCP defaults 3 Remote Port 502 Default Connection Address 192 168 1 34 Host mydns dyndns org Enable SSL m ft Settings ProSoft Technology Inc Page 77 of 106 September 29 2011 Network Settings for Local Access ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Page 78 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Network Settings for Remote Access Version 2 0 2 User Manual 8 Network Settings for Remote Access ProSoft i View is designed to communicate with PLCs without using dedicated servers or any specific software installed on a PC ProSoft i View communicates with PLCs using industrial protocol commands For remote connection a GPRS
33. ProSoft TECHNWNOEGSOGY Where Automation Connects ProSoft i View Mobile Process Monitoring and Control Flow Measurements Application Valve Control Version 2 0 2 Process Data Status Data September 29 2011 USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products If you have suggestions comments compliments or complaints about our products documentation or support please write or call us How to Contact Us ProSoft Technology 5201 Truxtun Ave 3rd Floor Bakersfield CA 93309 1 661 716 5100 1 661 716 5101 Fax www prosoft technology com support prosoft technology com Copyright 2011 ProSoft Technology Inc all rights reserved ProSoft i View User Manual September 29 2011 ProSoft Technology ProLinx 9 inRAx 9 ProTalk and RadioLinx are Registered Trademarks of ProSoft Technology Inc All other brand or product names are or may be trademarks of and are used to identify products and services of their respective owners ProSoft Technology Product Documentation In an effort to conserve paper ProSoft Technology no longer includes printed manuals with our product shipments User Manuals Datasheets Sample Ladder Files and Configuration Files are provided on the enclosed CD ROM in Adobe Acrobat Reader file format PDFs These product documentation files may also be freely downloaded from our web site www prosoft technol
34. ProSoft i View 61 StylesExampleEIP PCCC csv 94 StylesExampleModb csv 93 Supported Protocols 8 System Variables 47 ProSoft Technology Inc September 29 2011 Page 105 of 106 Index ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 T Tabbed Interface 10 Tag Attributes 26 U User Accounts 24 59 67 User Interface Elements 9 Using Expressions 43 V Validation Codes 17 78 Variable Addresses Column C 20 Variable Names Column A 17 21 Variable Types Column B 17 18 Variables in ProSoft i View 11 Ww What is ProSoft i View 3 Y Your Feedback Please 2 Page 106 of 106 ProSoft Technology Inc September 29 2011
35. R Input Register read only Individual bits in HRs can be accessed for HR Holding Register reading or writing using a dot notation For example HR1 3 would refer to bit 3 in HR1 EIP Native TAG deprecated do not use Actual symbolic tag name is given in column Allen Bradley A See Variable Names page 16 However EN l i TAG must still be specified in column C EIP PCCC O0 Outputs Tags are specified by file type file number and Allen Bradley 11 Inputs offset in the regular way Individual bits in S2 Status words can be accessed using the usual slash B3 Binary notation T4 Timer Examples C5 Counter B3 5 would access word 5 on file 3 of type B R6 Control N7 0 would access value at position 0 in N7 Nn Integer file Fn Floating Point N7 0 3 would access bit 3 in N7 0 STn String Accessing Data Types Longer Than One Register For data types requiring more than one register or memory location the lower address in their range must be specified For example a variable of type DINT addressed by HR100 will use HR100 and HR101 because 2 Modbus registers 16 bits are required to accommodate the complete variable 32 bits Integrators must be aware of this to avoid overlapping tag values This applies to all protocols except EIP Native Accessing a Register as a BOOL It is possible to specify a BOOL type for a register or memory location even if it is not meant to hold a BOOL For example you specify on a row
36. Ruby and want to test some ProSoft i View expressions before you start using them in your project you can try them on any of the available Ruby interpreters to help you understand how they work On any Mac OS X or Linux computer open the Terminal and type irb This will launch the interactive Ruby interpreter On the gt gt prompt type or paste any expression you would like to try Ruby can be installed on Windows as well Refer to this to begin with http www ruby lang org en downloads You can even type Ruby expressions right on your Internet Browser Go here http TryRuby org Just type or paste the expression examples in this manual on any of the mentioned tools and see whether they give the expected results ProSoft Technology Inc Page 47 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Values used in expressions or assigned to tag attributes using expressions are represented in engineering units ProSoft i View does not have a notion of PLC raw values except for writing or reading values from PLCs This is important in order to understand why assigning a value to a INTERNAL tag may not give the same result than writing it to a PLC tag and reading it back Differences are due to the implicit scaling descaling and type conversion performed on PLC tags See the value attribute description for a discussion on this subject When u
37. T REGISTERS in UlNTValue ReadOnly UINT ord 314 section INPUT REGISTERS in DINTValue ReadOnly DINT _IR6_ ord 321 section INPUT REGISTERS in UDINTValue ReadOnly UDINT IR8 0rd 324 section INPUT REGISTERS in REALValue ReadOnly REAL R10 ord 330 section INPUT REGISTERS INTValue ReadOnly INT HR4 ord 411 section INT HOLDING REGISTER INTValue INT HR4_ ord 412 section INT HOLDING REGISTER write access 9 22 UINTValue ReadOnly UINT HRS ord 414 section UINT HOLDING REGISTER 23 UINTValue UINT HRS _ord 415 section UINT HOLDING REGISTER write access 9 DINTValue_ReadOnly DINT HRG ord 421 section DINT HOLDING REGISTER 26 DINTValue DINT HRG ord 422 section DINT HOLDING REGISTER write access 9 27 UDINTValue ReadOnly UDINT HR8 _ord 424 section UDINT HOLDING REGISTER 29 UDINTValue UDINT HR8 ord 425 section UDINT HOLDING REGISTER write access 9 31 REALValue ReadOnly REAL HR10 ord 430 section REAL HOLDING REGISTER 32 REALValue REAL HR10 ord 431 section REAL HOLDING REGISTER write access 9 33 M MN DataTypesModbus lal ProSoft i View looks for the following information in each column Column A variable name Column B data type Column C variable address Column D tag or global attributes including display and communication attributes 3 1 1 Specification of Variable Names Column A Tag names are entered in column A t
38. The execution will in turn trigger relevant change events up the expressions tree just as any expression would do 2 only attends to expr change events Any changes in expr1 or expr2 will not have an effect until expr executes Furthermore if expr is false and expr2 was not specified the execution tree is trimmed at this stage and no further execution up the expression tree will happen is useful in cases where you want to achieve a differential effect for example to trigger an event when a condition goes from false to true but not the oposite This is not possible with 1 because it will always execute both ways Consider the following start BOOL INTERNAL label Start Button style Button write access 0 stop BOOL INTERNAL label Stop Button style Button write_access 0 motor BOOL C1 label Motor State value if start then 1 else if stop then 0 The previous lines will display a Start tand a Stop button When the Start button is touched 1 will be written to C1 When the stop button is touched 0 will be written to C1 Another use of the if then else clause is the implementation of a counter reset BOOL INTERNAL label Reset Button style Button write access 0 increment BOOL INTERNAL label Tick Button style Button write_access 0 counter DINT HR1 label Counter value if reset then 0 else if increment then counter 1 The Reset and Tick buttons will provide in this case the interface
39. This attribute can have several meanings depending on other attributes particularly the Style and the Write access attributes On writable tags it determines and limits the available range of values that users will be able to enter On read only tags its meaning depends on the particular style of the tag It is currently supported by the bar slider and alarm styles Example bounds 100 100 Format special text Text in the form m n where m represents the minimum number of characters to be displayed If the value to be displayed is shorter than this number the result is padded with blank spaces or zeros if the number starts with zero The value is not truncated even if the result is larger n represents the number of digits to be displayed after the decimal point Example format 07 2 will display the REAL value 12 345 as 0012 34 Prefix text Text to be prepended just before the variable value Example prefix z Suffix text Text to be appended to the variable value Example suffix z 96 ProSoft Technology Inc Page 27 of 106 September 29 2011 Data Source Files User Manual ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 TAG ATTRIBUTE Color Color Tint color Color bounds TYPE special text Expression Numeric special text Value list DESCRIPTION Indicates a color to apply to a variable value or control Colors can be specified by name
40. a living digital clock showing the current time Every 5 seconds the time is alternated with a temperature value given in a variable named temp In order to achieve this we enter the following expression in a row value SMPulse10s Time SMDate split 1 Temperature temp to_s 3 1f C We use the ternary operator to switch between the time and the temperature depending on the SMPulse10 system pulse variable For the clock we take SMDate and discard the date portion by splitting it out The temperature is presented formatted with a custom prefix and suffix appended to the actual value We can alternatively use the format function to simplify a bit some portions of the expression value SMPulse10s format Time s SMDate split 1 format Temp 963 1f F 9 5 celsius 32 ProSoft Technology Inc Page 59 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 3 2 Rockwell RSLogix 5000 as a Data Source Generator ProSoft i View accepts files generated directly from Rockwell s RSLogix development environment as data sources To import RSLogix files follow the following steps 3 2 1 Building a Project in RSLogix 5000 Create a new RSLogix project or open an existing one Instructions for programming a PLC are beyond the scope of this manual Please refer to your RSLogix documentation 3 2 2 Exporting Controller
41. able lists all operators from highest precedence to lowest Logical NOT unary plus unary minus left to right Aray or Siring subscript en O eo BMWseAND O fitore Comparison operators not associative Logical AND left to right l Logica OR left to right Ternary if then else right to left RE ee If than else If than else clause right to left Operators are used in the usual way as per the Ruby or C language Depending on data types involved the same operator may have a different meaning ProSoft Technology Inc Page 51 of 106 September 29 2011 Data Source Files User Manual ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 System Variables There are a number of system variables that can be used in expressions as if they would be regular tags The following variables are provided SMPulse10s SMPulse30s SMPulse60s SMAckButton SMCommState SMCurrentPage SMDate Number read only Number read only Number read only String read write String read only They generate a square wave signal with the period implicit on the variable name They can be used to implement a Keep Alive tag to write periodically a value on a PLC or to trigger periodic events for any purpose Variable linked to the Acknowledge button on the alarms panel Goes to 1 when the button is pushed and 0 when it is released A value indicating the current commu
42. accessing PLCs unless both codes match The next section describes validation codes and how you can set them up Finally physical access can compromise security It is relatively easy for an unauthorized user to gain physical access to a device and run a remote monitoring application To prevent this from happening ProSoft i View s user accounts provide password based security If you turn OFF the AUTOMATIC LOGIN switch in the ProSoft i View Settings tab a password key will be requested each time the application is launched Furthermore Apple provides a service for blocking lost or stolen devices so that no one is able to access data or execute apps in them until the real owner reactivates them Validation Codes For Allen Bradley EIP Native and EIP PCCC ProSoft i View requires a password code to be held by the PLC which is queried on each connection This password must be stored in your PLC as a 16 bit hexadecimal value 0 to FFFF and must match the value specified in Validation Code for connections to that PLC In most cases this security measure alone is enough for simple applications Validation Codes are stored in PLCs in the following memory address or tag depending on protocol ProSoft Technology Inc September 29 2011 Page 81 of 106 Security ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 PROTOCOL Default Tag REMARKS Modbus TCP IP Not Available See note below EIP
43. aeeeeeeaeeeeseaeeeeesaeeeessnaeeeesenaeeeeeegas 95 10 6 PagesExampleElP sv i i aimi i eps deligere e temetiepee d 96 10 7 StylesExampleModb csv sssssssssssssseeeenee nennen nnne nnne rne nnne 97 10 8 StylesExampleEIP PCCOC csv ssssssssssssseeeeeeeenee ener ener 98 10 9 AlarmsModb s 6Sv iaeenei eic eiie ie N ee vedi enu 99 10 10 Alarms EIP PECCO CSV oi URL en e aie eer E esed E eee ties 100 10 11 ColorfulControlsModbus Csv sss eene nennen nennen nnne 101 10 12 ColorfulControlSEIP_PCOCC CSV cccccccsssecceceeccsssnaeeeeeeeeeessessaeeeeeeeseessesaeeeeeees 102 10 13 Formula ONE CSV sic reden tee eit Weenie nlieer sewed 103 10 14 Document Revision History sesssseseseeeee eene 104 10 14 1 M CIAO LCD 104 Index 105 Page 6 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application General Aspects Version 2 0 2 User Manual 1 General Aspects In This Chapter Supported Protocols eee EE Het eninge 8 ProSoft i View is presented in a tabbed interface Every tab has its own role within the application and allows for different functions With ProSoft i View you can monitor data coming from various PLCs Generally you will use the SETTINGS FILE SERVER FILES and CONNECTIONS tabs during deployment stages The HOME tab shows real time values of process variables in PLCs and is the one you will us
44. an be used on protocols with no specific support for strings such as Modbus In this case n indicates the string buffer length i e the number of character bytes that should be allocated in the PLC for the string starting from the address specified in column C Note that CHAR 20 would mean an array of 20 character bytes however in all cases it will be treated as a single string with a capacity of 20 bytes Keep in mind that if you use a string encoding other that the default you must expect the string to hold less than n characters This is because on some encodings a single character may require multiple bytes to be represented This is a special purpose type used to create a text entry on a table which is referred to by tags having the Lookup style attribute Rows with the Lookup data type in column B will not cause any read or write operations to PLCs For more information see Lookup Tables page 37 When specifying the tag type you can optionally define an array size for it as shown above in italics When you do so the related variable will hold an array of values of the relevant type instead of a single value See Memory Arrays for more information Size definition is obligatory for CHAR types ProSoft Technology Inc September 29 2011 Page 19 of 106 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 3 1 3 Variable Addresses Column C A variable ad
45. and Arrays Appropriate operators and methods allow for conversion among types and to perform custom operations with great flexibility See the following sections for a discussion on methods and operators Page 48 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual Mixing Numbers Strings or Arrays is only possible through the use of the appropriate operators and methods that result in compatible types An immediate consequence is for instance that you are not allowed to add directly a number to a string unless you convert the string to a number first Thus some operators take particular significance depending on type as it is commonly accepted on most modern scripting languages including Ruby See next sections for a further discussion on this and other subjects Numeric values Numeric values in expressions and variables are internally stored as Double Float values 64 bits Values read from PLCs including BOOL and INT tags are scaled and converted to Double Float type before they are used in expressions All Arithmetic Logical and Comparison operations are performed as Double Float operations so you may never expect to obtain truncated values from arithmetic calculations The above statement may change in the future to give support for true integer arithmetic Currently an implicit conversion to an integer type is only
46. and existing source files will continue to work it is recommended for integrators to switch to the new syntax for new projects and to start a transition plan for existing ones For example myStructData 2 3 intMember may refer to an integer value referenced by the intMember member of element 2 3 of an array of structures Look at the EIP TAG Examples csv template for more examples of how to specify tag names for Allen Bradley Logix controllers As a general rule any Tag name path that refers to a scalar value BOOL SINT INT DINT REAL in a Logix Controller will be accessed by ProSoft i View Note that ProSoft i View performs a Validation Code security check before any other attempt to access any tags is made therefore it is mandatory to have a tag named SMValidationCode of type INT in your PLC For more information see Validation Codes page 81 Tag Scope Tags can be defined to have a local or global scope Local tags are identified as per the general specification of variable names that is beginning with a letter Global tags are identified by placing a sign before their actual name Examples local var global var Local tags have a scope limited to the data source file they are in When a local name is found in an expression its definition is looked for only in the same file the expression appears therefore you can use the same names and expressions in several source files without conflicts Global tags have an app
47. and set the gateway IP on the Channel Configuration panel For Modbus TCP IP based devices refer to the vendor s documentation 2 Log on to the GPRS or DSL router and configure NAT options to set up a bridge between the WAN and your PLC local address and port Note that the default port number is 44818 for Ethetnet IP and 502 for Modbus TCP IP The protocol on the router must be set to TCP IP Refer to your router documentation for details ProSoft Technology Inc Page 79 of 106 September 29 2011 Network Settings for Remote Access ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 3 If you have a fixed IP address enter it as such in ProSoft i View either as a Settings default or embedded in source files 4 f your router accesses the WAN through a dynamic IP then you must create an account with a dynamic DNS services provider such as www dyndns org and configure your router to notify of IP changes In this case enter in ProSoft i View the name you choose for your dynamic DNS The port number must still be the one configured in the NAT section of your router iPod 9 55 Remote Port Modbus TCP defaults Local Port Remote Port Default Connection Address 192 168 1 34 mydns dyndns org Enable SSL Page 80 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application
48. ation required by the attribute The general format is a list of numbers separated by colons and enclosed between and characters scale 0 360 0 100 bounds 0 100 color bounds inf 50 3 1 6 Tag Attributes A tag attribute is applied to a tag at the same row and exclusively affects that tag All attributes are optional and the specified attributes can be in any order ProSoft Technology Inc Page 25 of 106 September 29 2011 Data Source Files User Manual ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 The following attributes are supported TAG ATTRIBUTE Page Section Label Comment Style Ord Access TYPE text text text text special text number number DESCRIPTION Text indicating which page the variable belongs to Text values must be enclosed in quotation marks For example page FIRST PAGE Text indicating which section the variable belongs to Text values must be enclosed in quotation marks For example section z SECTION ONE Main text in the cell representing a variable If not specified the variable name in column A will be used instead Secondary text in the cell representing a variable If not specified a text comprising the variable address and its type will be displayed instead Text attribute allowing for additional ways to represent the value of a variable switch The default
49. ce Nonzero values are true Default value is false Byte swap number Swaps bytes for 16 bit or 32 bit data before sending to or boolean upon receiving from a Modbus device Nonzero values are true Default value is false The combined effect swap attributes is as follows Assuming a default of ABCD for a byte order where A is the Most Significant Byte MSB and D is the Least Significant Byte LSB you can combine Word swap and Byte swap with the following results 1 word swap zfalse byte swap false will give ABCD for 32 bit values and AB for 16 bit values 2 word swap false byte swap true will give BADC for 32 bit values and BA for 16 bit values 3 word swap true byte swap false will give CDAB for 32 bit values and AB for 16 bit values 4 word swap true byte swap true will give DCBA for 32 bit values and BA for 16 bit values Note These attributes are only meant for Modbus communications and are ignored for the rest of the supported protocols Page 34 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual Allen Bradley ControlLogix controllers can be plugged into any slot on the backplane Ethernet IP messages can be sent connected or unconnected The following attributes can be used to determine these characteristics These are global attributes
50. come active a Alarms will remain on the list as long as they remain active or have not been acknowledged Their current state will be shown by small icons next to the alarm text o Bright Red Alarm Clock icon means active and not acknowledged 9 Dark Red icon means active and acknowledged Gray Clock icon means inactive and not acknowledged For scalar type variables such as INT or REAL the bounds attribute determines the exclusion range of the alarm condition In other words an alarm styled tag will be considered active if its current value is NOT in the specified range For example consider the following style alarm bounds 0 100 The tag holding these attributes will be treated as an alarm which will become active when its value is below 0 or above 100 To support simple min or max condition alarms the special numeric values inf and inf can be used For more information refer to Attribute Scope and Kind page 25 For example style alarm bounds inf 100 ProSoft Technology Inc Page 39 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 will trigger the alarm only when the value on the tag is above 100 The default value for the Bounds attribute on alarm tags is bounds 0 0 Therefore any non zero value in a tag will trigger an alarm This is especially relevant for BOOL tag alarms because by default
51. dress represents a memory location or a register in a PLC to which a variable refers Addresses are specified in different ways depending on which communications protocol they belong to Therefore each protocol has its own set of valid addresses Addresses belonging to different protocols cannot be mixed in a particular source file Use a separate source file for each PLC and communication protocol The relevant communication protocol for a source file is uniquely determined by the kind of variable addresses included in it The particular protocol to use can be specified by means of a comment on the first line as described in Specification of Communication Protocol This comment may look something like this 9oprotocol eip native For protocols based on registers or memory locations Variable Addresses are specified by a prefix referring to the appropriate memory area followed by a numeric value indicating the position in that area Allen Bradley s Ethernet IP for Logix Controllers is based on symbolic names Write PLC Tag symbolic names in Column C Page 20 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual The following memory areas and prefixes are supported PROTOCOL AREA PREFIX Modbus TCP IP I Input Discrete read only To access Coil number 10 specify C10 To C Coil access Holding register 1 specify HR1 I
52. e 10 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application User Interface Elements Version 2 0 2 User Manual On the left side of each row the list shows relevant information for identifying variables such as their name or their particular role in the monitored process Real time values of variables or suitable controls for interacting with them are shown on the right side iPod 21 28 wail movistar gt GENERAL D Main Run Stop Switch Main Process Start Stop on E UINTValue 12345 WATER TANK HR00005 UINT Tank Level L 346 558 DINT HOLDING REGISTER Water Tank Current Level 2 DINTValue ReadOnly 987654321 Output Flow L s HR00006 DINT urrent Output Flow from Tank DINTValue 987654321 High Level Set Point L 500 dain ceed Level at which pumps stop L Mid Level Set Point L Level at which pump 1 stops 350 HR00008 UDINT 123456789 Low Level Set Point L UDINTValue Level at which pumps start 100 7 HR00008 UDINT 123456789 VALVE 1 I REAL HOLDING REGISTER Limit Switch REALValue ReadOnly Valve 1 Completely Open Cz HR00010 REAL 3 14159 REALValue HR00010 REAL 3 14159 iPod 22 32 Main Run Stop Switch Main Process Start Stop KEW WATER TANK Tank Level L Water Tank Current Level 346 172 Output Flow L s 15 4 Current Output Flow from Tank S High Level Set Point L 500 Level at which pumps stop
53. e available options on the Web page provided by the integrated Web server Below are two screenshots of the same screen one with an imaginary company logo and one with the default logo iPod 14 20 Pods 14 21 Overview gt Overview gt Valve Control B gt Valve Control B gt Process Data O gt Process Data o Status Data ae gt Status Data e gt Alarms Example o Alarms Example a we gt 3 p vie gt 3 y Home Home Imaginary Company Logo Default Logo ProSoft Technology Inc Page 67 of 106 September 29 2011 File Import into ProSoft i View ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Page 68 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 Connections User Manual 5 Connections Connections represent links between ProSoft i View and PLCs Each connection can have one or more associated sources Sources that share the same communication attributes are automatically grouped in a single connection You can look at connection states and their associated sources in the Connections tab view Source information including potential parsing errors is also displayed e 9 19 Connections Communication 9 Monitor Connections started 3 linked 3 failed 0 Connections Modbus TCP DataTypesModbusWSource Connected to 192 168 1
54. e changes trigger expression evaluation The engine is not endlessly executing for loops but only change events Expressions keep references to referring expressions to create a tree like network where all expressions have links to other expressions When a PLC tag changes or an user interacts on a control a change event is triggered This event that occurs at some point in the expressions network is propagated through the relevant links to reach only the expressions that need to know about it generally only a few The result is that expressions execution time is basically independent of project sizes or the total number of expressions defined in projects The Event Driven Architecture is specially suitable for running ProSoft i View in the constrained environment of a mobile device and still be able to support a very large number of tags with no noticeable performance penalties Page 46 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual Using Expressions ProSoft i View expression syntax is based on the open source Ruby scripting language syntax For basic operations this syntax is similar to that of the C programming language and virtually identical to all modern scripting languages The Ruby language was chosen because it features a clean easy to learn object oriented syntax with a particular focus on expressions
55. e for normal monitoring ProSoft i View automatically goes to this tab on launch ProSoft i View uses the concept of Data Sources see Data Sources page 15 and Connections see Connections page 69 to do its job Data Sources contain the variable definitions and Connections represent links with PLCs A Source is always associated with a Connection but a single Connection can belong to several Sources ProSoft i View also supports user accounts with access levels that can limit the ability to perform certain operations ProSoft Technology Inc Page 7 of 106 September 29 2011 General Aspects ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 1 1 Supported Protocols ProSoft i View gets variable values from industrial PLCs by polling them using TCP IP industrial protocols The following protocols are supported PROTOCOL SUPPORTED PLCs or Brands REMARKS NAME Not exhaustive Modbus TCP Schneider Electric Automation Direct For communication with PLCs and Phoenix Contact Wago RTUs using the Modbus TCP IP specification EIP Native Allen Bradley ControlLogix and Native CIP communications using CompactLogix EtherNet IP Explicit Messaging EIP PCCC Allen Bradley SLC 500 and PCCC commands DF1 encapsulated MicroLogix controllers in EtherNet IP Page 8 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and C
56. ely and then sum them to get the total number of seconds The extraction of each value from the original string is performed by the split method using as delimiter The relevant element from the split array is obtained with the fetch method We use 0 as the default value for fetching Note that we could have used simple array indexing such as t split 3 to get each part of the original string but this would lead to potential out of bound errors if the original string had some missing part Particularly if the original string did only contain minutes and seconds such as 50 30 50 minutes 30 seconds the referred indexed expression would give an out of bounds error as it would attempt to access a non existing element the one before the first one Note also that in all cases we use negative indexing because we interpret that the last part is always meant to be the seconds the previous to the last one the minutes and so on The proposed expression can be optionally optimized by storing the split string in a temporary variable so that the splitting is only performed once If we apply this optimization the final solution would look as follows tspt STRING 3 INTERNAL value t split seconds DINT INTERNAL value 3600 tspt fetch 3 0 to_i 60 tspt fetch 2 0 to_i tspt fetch 1 0 to_i Creating a row that alternates between displaying the current time and an arbitrary value In this example we will create a row that shows
57. ferences in its value expression can not be user writable and will ignore an eventual write access attribute NOTE this restriction was removed after version 1 5 Despite the preceding consideration INTERNAL tags will preserve the meaning of the write access attribute if their value expression represents a constant value in such case the expression will provide the initial value for the tag Writable INTERNAL tags will simulate a write read round on a virtual PLC taking into account tag type scale and bounds attributes with the same effects as a real write read round as described above Numeric expression Will make the row hidden when the result of the expression is non zero Hiding all rows in a Section will remove the entire section including the section title Hiding all rows sections on a page will remove that page from the interface Hiding showing interface elements is fully animated and dynamic on evaluation of the hidden expression Dynamic hiding is useful to switch among several rows that selectively meet an arbitrary condition or to force display parts of the interface depending on user or PLC triggered conditions Attribute containing one of the texts below determining ways to represent or display the value of a variable Page 30 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 Data Source Files User Manual s
58. following source file formats for import csv generated by Excel or Open Office txt any text file with tab comma or semicolon field delimiters generated by Excel OpenOffice NotePad etc csv generated by RSLogix Note The recommended way to generate source files is to begin with one of the provided examples and then continue by editing what is missing ProSoft Technology Inc Page 65 of 106 September 29 2011 File Import into ProSoft i View ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 4 2 Other Files Supported by ProSoft i View ProSoft i View is able to store and display a number of file formats in addition to source files File types supported for display include but are not limited to Excel xls PDF pdf Powerpoint ppt Word doc Rich Text Format rtf Image files png jpg gif The capability to store and view files can be useful for document specific configurations or simply for moving documents between computers ProSoft i View is able to store any file type even those that are not supported for display Page 66 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application File Import into ProSoft i View Version 2 0 2 User Manual 4 3 Custom Company Logo You can place a custom logo on top of the Home view when the list of pages is seen You do this by using th
59. for a counter value written to the PLC Page 56 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual Now consider the following case color1 UDINT INTERNAL label Color A Meee write_access 0 color2 UDINT INTERNAL label Color 2 write access 0 colorSelection BOOL INTERNAL label Select Color style Switch write access 0 coloredValue DINT HR1 label Colored Value color colorSelection color1 color2 The coloredValue color will be always updated according to colorSelection after any change of color1 or color2 ProSoft Technology Inc Page 57 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Putting it all together Advanced Expressions Examples Converting an arbitrary number of seconds to hh mm ss format The following expression shows how to get a string in the form hh mm ss from a numeric value containing seconds In this example x contains the total number of seconds to be converted to the desired format value x 3600 to_s 02d x 3600 60 to_s 02d x 60 to_s 02d join The operators and are used to calculate hours minutes seconds as numeric values These are then truncated to integer with the to method and successively converted to formatted strings
60. for using a custom validation tag on protocols supporting it For EIP PCCC use validation tag Nx y only N files can be used and the code is stored as an INT default is N98 0 For FINS TCP use validation tag Dx only DM area can be used and the code is stored as a WORD default is D19998 For EIP NATIVE the validation tag name is always SMValidationTag it can not be changed For MODBUS TCP no validation tag is available If no attribute from this group is specified ProSoft i View will dynamically use values from the application Settings tab view The Modbus specification does not define exactly how the data is stored in registers or the order in which bytes or words are sent The following global attributes help to deal with this Swapped words bytes options for Modbus are global ProSoft Technology Inc Page 33 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 MODBUS GLOBAL ATTRIBUTES TYPE DESCRIPTION rtu mode number ProSoft i View will use Modbus RTU over TCP instead boolean of Modbus TCP This will allow for accessing serial modbus RTU devices behind an Ethernet to serial gateway not supporting MBAP Use the slave id attibute on tags to route commands to the right modbus slave node Word swap number Swaps words for 32 bit data such as DINT or REAL boolean before sending to or upon receiving from a Modbus devi
61. gh Select Value for tag above 239 146 De aad O SIMULATED CONTROLS NN Colored Value ad Temperature 15 4 C Dark Blue above 100 Red above 200 7 Moisture 68 9 Colored Input Value f 266 9 i e 00 Dark Blue above 100 Red above 200 ProSoft Technology Inc Page 101 of 106 September 29 2011 Pre installed Examples ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 10 12 ColorfulControlsEIP_PCCC csv Identical to the previous one but based on the EtherNet IP PCCC protocol Page 102 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Pre installed Examples Version 2 0 2 User Manual 10 13 Formula ONE csv This example shows several aspects and possibilities of using expressions on attributes The example is self contained by using only LOCAL tags and it does not need an actual PLC connection to run It is structured in pages and fully commented to demonstrate Switching and displaying hiding of rows on the interface based on user selectable style Use of the picker attribute to allow users to retrieve a value based on a picker wheel control Complete or partial removal of rows sections and pages based on simple boolean states Arithmetic and boolean calculations based on tag values Implementation of controls to enable disable particular alarms Use of system variable
62. gy Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual 3 3 Editing Source Files in a Text Editor Since source files created in any of the ways described above are simply CSV files they are essentially text files as well Integrators and advanced users can conveniently edit them with any text editor such as WordPad or NotePad and save them in plain text format It is also possible to create either CSV or TXT files from scratch in a text editor If you choose to use a text editor to create or edit source files you need to be aware of the double quoting that Excel applies to text columns containing quotes So you will need to add them manually where necessary This is not anything particular to ProSoft i View itis just how CSVs are Double quoting is particularly relevant for column D of a ProSoft i View source file because many attributes expect a text string as their value which may be enclosed in quotation marks When entering attributes in Excel you do not need to take any special care on this However the same file edited in NotePad will reveal the existence of extra quoting that Excel automatically inserts to avoid text conflicts and to meet the CSV spec As an example assuming an Allen Bradley controller tag name is main switch the row referred to in the Attributes section page 24 would look like this in the text editor main switch B
63. he application Non administrator accounts have restricted access to deployment features and not all tabs are available to them The following screenshots show the available tabs for the Administrator left and for a regular user right llmovistar gt MENEMAL 21 09 iPod MALINLEDAL Main Run Stop Switch Main Process Start Stop WATER IANA Main Run Stop Switch Main Process Start Stop PRAT SAINI Tank Level L Water Tank Current Level 346 558 Output Flow L s 15 4 Current Output Flow from Tank 5 High Level Set Point L 500 Level at which pumps stop Mid Level Set Point L 350 Level at which pump 1 stops Low Level Set Point L 100 7 Level at which pumps start Tank Level L Water Tank Current Level Output Flow L s Current Output Flow from Tank High Level Set Point L Level at which pumps stop Mid Level Set Point L Level at which pump 1 stops Low Level Set Point L Level at which pumps start 320 225 15 4 500 350 100 7 Limit Switch Valve 1 E administrator user Limit Switch Valve 1 Completely Open regular user Page 72 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application User Accounts Version 2 0 2 User Manual 6 2 Managing Accounts Accounts are managed in a navigation interface similar to that of the Contacts application The screenshot below sh
64. he user for selection See Lookup Table It is like the Iookup style except that it will draw a bezel around the displayed lookup text when used on writable tags ProSoft Technology Inc September 29 2011 Page 31 of 106 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Tags with this style are referred to as Alarm Tags and they are not shown on the main table but on the Alarms Panel They can be combined with the bounds attribute See Alarms barcode Activates the barcode reader for this tag The tag must be writable usually of type STRING After reading a barcode with the device camera the tag will be updated with the scanned code Tag attributes specific to Modbus devices MODBUS TAG Slave id number This attribute identifies the associated tag as belonging to a particular Modbus device Specifically Modbus serial devices with the specified ID that are connected through a TCP gateway will be accessed The default value is 1 Note that the S ave id attribute for Modbus is a tag attribute so it applies only to the register it is next to This is in contrast to the Controller slot attribute which is global and applies to a source file Page 32 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual 3 1 7 Global Attrib
65. hey must begin with a letter and should not contain spaces or special characters For Register or Memory Area based protocols tag names are only informative or for documentation purposes Variables can hold numeric values strings or arrays For ElP Native variable names are symbolic names that are actually sent to remote devices for communications In this case any valid reference to a scalar type see Variable Types page 18 including members of structures or array elements is allowed Page 16 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual EIP Native protocol AB Logix controllers Legacy Note Prior to ProSoft i View version 1 5 EIP Native tag names used to be specified in Column A However with the incorporation of expressions and in order to favor a general syntax for all protocols this has been deprecated From ProSoft i View version 1 5 it is obligatory to adhere to the General Rule if you want to use tags in expressions In this case you must specify EIP Native as communication protocol and you have to set the actual PLC tag name in Column C instead of column A The name that you enter in Column A can be used then in expressions If you are not going to use expressions you can still enter a EIP Native PLC tag name in Column A and write TAG in column C as in pre 1 5 versions Although this is still allowed
66. ibility of assigning memory addresses or registers as well as the need to take tag sizes into account for storage Additionally EIP Native tags hold data information such as type and size which ProSoft i View uses to check against type mismatches on PLC returned values As a result it is not possible to store values that differ in type or size from the values uniquely defined in the PLC Any attempt to do so will result in a type mismatch error for the offending tag For EIP Native symbolic names any valid reference to an existing scalar or array type tag including structure members or array elements is allowed For example myStructData 2 3 intMember may refer to an integer value referenced by the intMember member of element 2 3 of an array of structures Look at EIP TAG Examples csv template for more examples of how to specify tag names for Allen Bradley Logix controllers As a general rule any Tag name path referring to an existing scalar value BOOL SINT INT DINT REAL STRING or array of such elements in a Logix Controller can be accessed by ProSoft i View To access arrays as a whole you need to define an array size next to the type as discussed on the previous and following sections You can also access program tags by using the following syntax Program program name tag name Note that Program is literal program name and tag name identify just what they suggest Note also that ProSoft i View perform
67. ile contents and to perform various operations Follow the steps below to use the integrated Web server 1 Goto the FILE SERVER tab Note In order to access files you must log in to the administrator account The initial password is admin ProSoft i View sets itself to this account on first launch See User Accounts page 71 2 Switch the File Server ON 3 With ProSoft i View s File Server started copy the displayed IP address to your PC s Web browser If you use Apple s Safari browser you can simply click on the relevant Bonjour link ProSoft Technology Inc Page 63 of 106 September 29 2011 File Import into ProSoft i View User Manual ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 4 Now use the available options on the displayed Web page to move files to and from ProSoft i View You can upload any files and store them in your iPhone iPod 5 14 PM lew and a link provided Apple s Bonjour technology is supported for Safari browser on while the server is ON the device will never be put into sleep mode http2 192 168 1 45 8080 Bonjour Ordenador de JOAN 6 PO ue Vite Server Page 64 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application File Import into ProSoft i View Version 2 0 2 User Manual 4 1 Source Files Supported by ProSoft i View ProSoft i View supports the
68. iles ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 The Format Function The built in function format returns a string formatted according to a format string like the usual printf conventions of the C language In addition format accepts 26b for binary ProSoft i View format specifiers adopt the following form lt flags gt lt width gt lt precision gt specifier Where specifier is the most significant one and defines the type and the interpretation of the value of the corresponding argument and gt denote optional fields Note that the string provided for the format tag attribute or the format string passed to the to_s method have a slightly different purpose and may have less available options The following format conversion specifiers are available FORMAT format to_s format SPECIFIER Description attribute method function support support support Single character YES Exponential notation e g YES 2 4466 E Exponential notation e g YES 2 44E6 Floating point number e g YES 2 44 Use the shorter of e or f YES Use the shorter of E or f YES Page 54 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual FORMAT format to s format SPECIFIER Description attribute method function support support support Octal integer YES
69. ing the best of the app for your particular project ProSoft i View automatically performs the following optimizations Only the minimum set of tags necessary to display the interface is polled at a given time Particularly tags that are not used in expressions and which values are not shown on the interface at a given time are not polled at all Therefore the less tags you link with expressions or use in expressions the better In fact having a large number of tags for the single purpose of showing their PLC value will not incur in any performance penalty because most of the time they will not be polled out from the PLC anyway fa particular PLC address needs to be read at a given time it will only be read once per polling cycle regardless of how many instances of tags tied to that address are found in the project Consequently you can repeat the same PLC tag address as many times as you need in your project without having to worry about any performance penalty The list of candidate tags to be read at a given time is applied a minimal cost algorithm to determine the less and shorter available communication frames for the relevant protocol which fulfill the entire request The optimal solution may include reading unsolicited tags if this justify a better performance figure The simpler scenario is reading several almost contiguous tags with a small gap in between Reading all of them and then discarding the unused ones may be fas
70. ix it with a sign ProSoft Technology Inc Page 23 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 3 1 4 Attributes Column D Process variables in ProSoft i View are represented in cells You can configure the behavior and display of the monitored variables by setting the appropriate attributes For example some of the available attributes are section label and comment section cell label M Tank Level L 392 561 process ove variable a An attribute description in column D of a source file follows this general pattern attribute value For example a boolean process variable like the one represented in the first cell on the figure above could have the following attribute description ord 1 section GENERAL label Main Run Stop Switch comment Main Process Start Stop access 3 write access i5 The way the cell is actually displayed in the figure implies that the current user has an access level of 5 or above because a selectable switch is provided as the process variable value instead of static text See User Accounts page 71 Page 24 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual 3 1 5 Attribute Scope and Type Attributes by Scope
71. l Application Pre installed Examples Version 2 0 2 User Manual 10 7 StylesExampleModb csv This example shows the available styles and some related tag attributes such as Scale Format Bounds Prefix Suffix as well as the use of lookup tables iPod 22 15 iPod gt 21 36 LECO O E ig E Tags Scalar Values Just to Change Above Texts Enter value to change third text above n Scaling Formating Wgt 3 399 kg Lookup Value group 2 5 Scaled and Formated Value Enter value to change forth text above Bar Style Weight 3 399 kg 7 um 3399 g Slider Style 3399 g nter rate I Production o Format in Writable Value Z zoa Enter rate 89 0 Writable value with bezel and format 3 399 kg Weight 3 399 kg Writable Value 3399 ea 070 Writable value with no style Production Rate 89 0 Default Style 3399 Values are displayed this way with no style Fan Control 9 Default Style REAL value Yo Selected Fan Speed ae A real value with no style 35 0534 Speed 24 4 Bezel Style rs 07 Writable value 3 xw style 35 0534 Average Home iPod 22 15 Everything is OK Human presence detected in the restricted area This is entry 3 on the second table so it will show if tag value is 3 Second boiler pressuse is above limits Just to Change Above Texts Lookup Value group 1 f o Enter value to change first text above Lookup Value group 1 f 4 Enter value to change
72. lication wide scope so you can only have single instances of them across all selected source files The advantage of using them is that you can access to their values from anywhere in your project even if the project is made of several source files ProSoft Technology Inc Page 17 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 3 1 2 Variable Types Column B Data types determine in part how variables will be displayed Non boolean scalar types can be represented in various ways such as by a number a slider control or a progress bar Boolean values can also be displayed in several formats depending on attributes Arrays of values can also be stored in variables and transferred from to PLCs By properly using array expressions you can retrieve individual values as desired To indicate that a variable holds an array you append n to its data type In such case n indicates the total number of elements that the array will hold Page 18 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Version 2 0 2 Data Source Files User Manual The following types are supported DATA TYPE BOOL n SINT n INT n UINT n UINT BCD n DINT n UDINT n UDINT_BCDjn REAL n CHANNEL n WORD n DWORD n STRING n CHARI n LOOKUP REMARKS Value that can adopt
73. mple the setting scale 0 10 100 110 will forward any raw value coming from the PLC in the range from 0 to 10 to table text entries from 100 to 110 You can use this feature to effectively have several virtual tables simultaneously in use The StylesExampleModb example shows how this concept works The global lookup table is available to expressions with the SM lookup method Page 38 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual 3 1 10 Alarms An alarm tag is a special kind of tag that is not displayed in the main tags table An alarm tag is characterized by its Style attribute being set to alarm Alarm conditions can be specified with the Style attribute in combination with the Bounds attribute attached to the tag Alarms are tracked and listed on a separate table as shown in the screenshot below When an alarm condition is triggered the tag Label attribute is used to display the text on the left which may refer to an alarm group and the Comment attribute contains the alarm message displayed on the right Jlmovistar gt 16 02 Acknowledge Alarms Grou p 1 Weight Value went above 6 kg Group 2 Second alarm in group 2 did become active Group Weight Value went below 3 kg Grou p Someone Manipulated the Switch Group Third alarm in group 2 did become active Group Second alarm in group 2 did be
74. n in the background or in the lock state is an Apple choice and it is currently set at 10 minutes ProSoft i View like any other application will be switched off or suspended after this time has expired Therefore end users are advised to put ProSoft i View in the foreground as soon as they have completed other tasks and not allowing the device to go to sleep if it is essential to keep alarms and graphs updated at all times ProSoft Technology Inc Page 85 of 106 September 29 2011 Security ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 9 3 Performance ProSoft i View is designed to offer great performance and a satisfactory user experience with good interface responsiveness Integrators do not usually need to take particular actions to improve performance The app carries out a series of optimizations on tags and PLC communications that in most cases are enough to relieve integrators from having to adopt particular actions or design patters Still understanding what optimizations ProSoft i View performs can be useful to find out Why if ever a performance issue arose and what you can do to improve on it Performance matters tend to be a complex subject and extensive discussions can be made ultimately testing is the only way to have a trustable answer We will just enumerate some of the techniques used in ProSoft i View to maximize performance and will give some tips to help you gett
75. nconnected messaging may be a better choice Wireless spots or carrier networks can easily drop due to lack of coverage or weak signal in these cases connected messaging communications may take longer to reestablish after a fault resulting in less overall reliability and more user perceived delays than unconnected messaging ProSoft i View uses unconnected messaging by default but you can set it to use connected messaging for a source file by setting the connected mode attribute to true Note that since the Controller slot attribute is a global one it applies to the whole source file This is in contrast to the S ave id attribute for Modbus which only applies to the tag next to it Also note that since different protocols cannot be mixed in the same source file the two attributes are incompatible between them and the non relevant one will be ignored ProSoft Technology Inc Page 35 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 3 1 8 Pages Sections Rows and Data Sources Page Section and Ord Attributes The ProSoft i View interface for the iPhone and iPod Touch consists of a set of cells or rows representing PLC variable values which in turn are arranged in pages containing section headers for groups or rows Variables are optionally assigned a page and section through the Page and Section attributes All variables having exactly
76. nication state of ProSoft i View Possible values are the following 0 Communications running with all PLC connections linked 1 Monitor is switched off 2 One or more PLC are not linked or a new connection is in course Partial link state 3 General communications error No communication is established This variable can be used to implement alarms related to PLC reachability or to show hide interface elements depending on PLC availability Name of currently displayed page Twext representation of the current date and time in the following format yyyy mm dd hh mm ss Functions Methods and more about Operators Methods can be applied to intermediate expressions or variables to perform type conversions or to achieve particular requirements They are like computer language functions that perform particular tasks Not all methods are applicable to all types and their meaning can vary depending on type Methods are invoked by appending a dot method selector operator followed by its name to the variable or subexpression they apply to Operators can also have a different meaning depending on the type of data they are applied to In the following tables we represent the meaning of the applicable operators and methods depending on data type Page 52 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Man
77. of type LOOKUP set in column B and by specifying the related indexes in column C The text or the comment attribute value on column D is the Lookup Text ProSoft Technology Inc Page 37 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 As an example this is what you could do to create a two entry table with indexes 1 and 2 Column A Column B Column C Column D entry1 LOOKUP entry2 LOOKUP 1 This is the lookup table at index 1 2 This is the second entry in the table so it will display if a lookup tag value is 2 Lookup numbers do not need to be ordered or contiguous They can be any number that fits in 16 bits 0 to 65535 Multiple User Lookup Tables You can specify an access level for entries in column D In this case you must set the lookup text in the Comment attribute This allows for having different texts depending on user level For example consider the following Column A Column B Column C Column D entry1 boss LOOKUP 1 access 9 comment Only will see this message I m the boss entry1 worker LOOKUP 1 access 3 comment can see this with my user level of 3 or more Multiple Range Lookup Tables Lookup styled tags use the engineering unit as the index to the table Therefore you can use the scale attribute to make a lookup styled tag access to determinate portions or ranges of the table For exa
78. ogy com Quick Start What is ProSoft i View ProSoft i View is a native iPhone and iPod touch application for real time monitoring of industrial PLC based systems and processes In can be applied to building automation industrial process control mini hydro power plants water plants and applications where reliable instant access to real time remote data is essential xiulmovistar Weight Value Linked to several alarms Wgt 7 562 kg Bar Style Weight 7 562 kg Slide to trigger alarms 7562 g SS Writable Value Change value to trigger alarms 7 562 kg Alarm 1 pensum Acknowledge Alarms Group 1 Weight Value went above 6 kg Group 2 Second alarm in group 2 did become active Group 1 Weight Value went below 3 kg Main Features Local or remote access and any number of concurrent PLCs Very fast independent of project size immediate connection and display Integer floating point and boolean values Advanced String and Arrays Support Direct file import from Excel Configurable accounts with access levels Alarms trend graphs Lookup texts expressions Direct connection to PLCs and RTUs without servers TCP IP based security 0000000000 How to Use ProSoft i View in Five Simple Steps 1 2 3 4 Create an Excel sheet that specifies parameters for the variables to be controlled See Data Source Files page 15 Export or save into a CSV file Import the
79. one of two states 8 bit signed integer value 128 127 16 bit signed integer value 32768 432767 16 bit unsigned integer value 0 65535 4 digit BCD value stored in a 16 bit register using 4 bits per digit 0 9999 32 bit signed integer value 2147483648 2147483647 32 bit unsigned integer value 0 4294967295 8 digit BCD value stored in two 16 bit registers using 4 bits per digit 0 99999999 32 bit floating point value IEEE 754 approx 1638 1e38 Same as UINT Same as UINT Same as UDINT Type containing a characters string Actual representation depends on protocol for example Allen Bradley controllers can hold up to 82 character bytes Strings on controllers are interpreted by default as per the WINDOWS LATIN1 encoding but other encodings are possible if a Explicitly Encoding or a UTF 16 file is given The STRING type should be used with the appropriate string memory area or string tag type in the controller when available On protocols with no explicitly support for strings ProSoft i View uses a generic string representation consisting on a leading word 16 bit register containing the length of the string followed by a 82 byte long string buffer Note that STRING n does not indicate a string containing n characters but an array holding n strings with the default capacity Particularly do not confuse with CHAR n Similar to STRING except that it does not insert a leading length word It c
80. ontrol Application User Interface Elements Version 2 0 2 User Manual 2 User Interface Elements In This Chapter Tabbed Interface ater eee intr red 10 Variables in ProSoft i View essseennemenemn 10 Home Tab Bar and Navigation Bar seee 12 Bottom Panel etri dic ub eerte 13 This section provides an overview of the main aspects of the ProSoft i View user interface It is not an exhaustive explanation Most interface elements will be described as needed in later sections ProSoft Technology Inc Page 9 of 106 September 29 2011 User Interface Elements ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 2 1 Tabbed Interface ProSoft i View uses the typical iPhone tabbed interface to organize several aspects of the application On each tab a navigation interface is usually presented Not all tabs are available to all user accounts and not all the options in a tab are accessible to all users Five tabs are available 2 1 1 Settings Available to all users but with restricted options for non Administrator users From this tab Administrator users can create accounts log in to a particular account set several user interface behaviors and specify default communication settings Non Administrator users have all options disabled except the log in feature 2 1 2 File Server Only available to the Administrator user Allo
81. or DSL router is needed at the PLC site The router acts as a bridge between the LAN Local Network where the PLC is installed and the WWAN or WAN Internet that a remote iPhone or iPod Touch will have access to This figure shows a standard setup Internet Local Network i i i i il WAN IP myname dyndns org LOCAL IP 192 168 1 40 LOCAL IP 192 168 1 1 1 Determine the LOCAL IP address of the GPRS or ADSL router PLCs need to know the router address as it is the gateway to the internet For EIP Native protocol and Allen Bradley controllers use the RSLogix tool to set the fixed local router IP gateway in the ethernet Module Properties dialog box lll Module Properties Controller 1 1769 L32E Ethernet Port 15 3 General Connection RSNetWorx Module Info P Port Diagnostics IP Address 132 168 1 39 Domain Name Must Match IP Address on General T ab cens Subnet Mask 255 255 255 Select Port Speed 100 Mbps z Gateway Address 192 168 1 Curent Port Speed 100 Mbps Primary DNS 0 0 0 Select Duplex Full Duplex v Server Address Secondary DNS 0 0 0 Current Duplex Full Duplex Server Address Changes to Port Speed and Enable Bootp Duplex require module reset Enable DHCP DHCP must be configured to return a fixed address IV Enable DNS Auto Negotiate Port Speed and Duplex Refresh Set Status Running Cancel Help For EIP PCCC protocol use Allen Bradley s RSLogix 500 tool
82. order to view a variable By default access z9 is set Page 26 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual TAG ATTRIBUTE TYPE DESCRIPTION Write access number Indicates the minimum access level an user needs in order to trigger changes write to a process variable value Omitting this attribute forbids any change to the associated variable On label Expression string String expression displayed for a read only boolean variable when its value is 1 true Off label Expression string String expression for a read only boolean variable when its value is O false Button label Expression string String expression In combination with the button style it defines the text for the button Scale array A four element array in the form x1 x2 y1 y2 where X1 x2 represent a pair of numeric values in raw units as present in the PLC and y1 y2 represent the same values in engineering units as will be displayed on ProSoft i View By setting this tag attribute you can convert scale raw values to engineering values on the display by applying a linear transformation This attribute can be specified for any read only or writable tag Example scale 0 100 0 1 Bounds array A two element array in the form min max where min and max are numeric values used to indicate a range expressed in engineering units
83. ources and Specification of Communication Protocol Extended section Expressions to cover Strings and Arrays Extended and renamed section Supported Operators and Operator Precedence Added section Data types in Expressions extending and replacing some subheadings in the old Expressions section Updated section System Variables Added section Functions Methods and more about Operators Added section Putting it all together Advanced Expressions Examples Added chapter Performance Added Document Revision History Page 104 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Index Version 2 0 2 User Manual How It Works 36 Index How to Contact Us 2 A Accessing a Register as a BOOL 21 Accessing Data Types Longer Than One Register 21 Accessing Individual Bits in a Register 22 Alarms 26 39 AlarmsEIP PCCC csv 96 AlarmsModbus csv 95 Attribute Scope and Type 25 40 Attributes Column D 24 56 57 67 73 Attributes by Scope 25 Attributes by Type 25 B Background Process 81 Background Task Processing 80 Bottom Panel 13 Building a Project in RSLogix 5000 56 C ColorfulControlsEIP PCCC csv 98 ColorfulControlsModbus csv 97 Connections 7 10 65 Custom Company Logo 63 D Data Source Files 4 7 15 Data Sources Created in Excel 16 DataTypesModbus csv
84. ows that a new account named Tommy has been created which has an access level of 3 and is active User Settings Automatic login Default accounts v administrator Manage accounts v nobody Other accounts File Server v Tommy Port New account Omron FINS TCP defaults To log in as a particular user tap on CURRENT ACCOUNT You can also make ProSoft i View ask for the current account password at launch To do so set the AUTOMATIC LOGIN switch in Settings to OFF ProSoft Technology Inc Page 73 of 106 September 29 2011 User Accounts ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Page 74 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Network Settings for Local Access Version 2 0 2 User Manual 7 Network Settings for Local Access In This Chapter PLC Settings for Local Access sssssseeeneemem 76 ProSoft i View Settings for Local PLC Access seesesss 77 ProSoft i View uses wireless TCP IP technology to connect to and communicate with PLCs Direct access from a local network requires both devices to be on the same subnet The PLC acts as the communications server and the iPhone or iPod Touch is the Client The following picture shows a typical setup using the recommended industrial wireless hardware but basically any WiFi router will do it
85. r attribute Therefore tag values will be displayed in the specified color only when they are below 50 or above 50 effectively enabling coloring for edge conditions For boolean tags the color bounds attribute has a predetermined value that will always make the tag appear in the color color for the On state Page 28 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual TAG ATTRIBUTE TYPE DESCRIPTION Tint color bounds Value list A two element array in the form low high where low and high are numeric values determining the range of values for the tag where the tint color will NOT apply also known as an exclusion range Refer to the Color bounds attribute for more information When both Tint color bounds and Color bounds attributes are specified Color bounds takes preference over Tint color bounds However Tint color bounds still has the chance to act in the range that has been excluded by Color bounds allowing for further color customization based on tag value Combined examples color bounds inf 50 tint color bounds inf 0 Will display all values above 50 in the Color color positive values up to 50 will be displayed in the Tint color color color bounds 50 50 tint color bounds 20 20 Will display all values below 50 and above 50 in the Color color Values from 20 to 20 will
86. r page and section according to their Ord number Page 36 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual Example The following Page Section Ord attributes in a series of tags from two sources will be arranged as shown below Source 1 Source 2 Tag Attributes Tag Attributes TAG A page Page 1 section Section 1 ord 1 TAG D page Page 1 section Section 2 ord 4 TAG B page Page 2 section Section 1 ord 2 TAG E page Page 2 section Section 2 ord 5 TAG C page Page 3 section Section 1 ord 3 TAG F page Page 3 section Section 2 ord 6 Resulting arrangement of tags In Pages and Sections Page 1 Page 2 Page 3 TAGA TAG B TAG C TAG D TAG E TAG F 3 1 9 Lookup Tables The Lookup table feature allows a tag to pick up a text string from a previously entered list based on current tag value and display this text instead of the tag value To have a tag display a lookup text instead of the usual value use the Style attribute with lookup as value style lookup If you would like to show the lookup text alone as shown in the StylesExampleModb example you might consider setting the tag label to an empty text label z The actual table is given in additional rows in the CSV file by using special tags
87. r show the navigation bar on the Home view use a scroll down motion while on top of the Tags table To switch from one page to another use a scroll left or scroll right motion on the page title To hide or show the page control on the navigation bar use the PAGE DETENTS option on the Settings tab To navigate to the list of pages tap on the navigation bar s left button To see alarms or trend graphs tap on the navigation bar s right button 2 4 Bottom Panel Tapping on the navigation bar s right button in Home view will cause the bottom panel to appear The various user interface elements in it allow you to view and acknowledge alarms as well as to create any number of trend graphs with any number of plots in them ProSoft Technology Inc Page 13 of 106 September 29 2011 User Interface Elements ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Just scroll the panel left and right to move to various pages on it The page control on the bottom also provides a way to switch between bottom panel pages Scaling Formating Scaled and Formated Value Wgt 1 940 kg Bar Style Weight 1 940 kg Slider Style 1940 g Format in Writable Value mat 1 940 kg Bottom Panel Page 14 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual 3
88. rm checks for a value being too high on the statistics page 3 1 12 Specification of Communication Protocol Starting with version 1 5 you can explicitly set the communication protocol on source files instead of having ProSoft i View determining it by the kind of addresses used in Column C as before This feature has been provided to grant future compatibility with a larger number of communication protocols where some addressing naming conventions could conflict or overlap existing ones To tell the actual communication protocol on a source file you must insert the following comment as the first line Page 40 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual protocol protocol string As protocol string you can use one of the following eip native eip pccc modbus tcp fins tcp For example to communicate to an Allen Bradley ControlLogix you would have the following as the first line on your source file protocol eip native NOTE Protocol Specification in this way will be made obligatory in the future so it is recommended for integrators and advanced users to use the new syntax for new projects and to set a plan to edit their source files to conform with it 3 1 13 International Languages Support and String Encodings The ProSoft i View iOS app includes localizations for English and Spanish for its
89. s a Validation Code security check before any other attempt to access other tags is made therefore it is mandatory to have a tag named SMValidationCode of type INT in your PLC for communications to work Page 22 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual Internal Tags Internal tags are stored and managed inside the ProSoft i View app Internal tags mostly behave as actual PLC tags except that they are not linked to an actual PLC address Thus internal tags do not require an active TCP connection to display a value In combination with expressions internal tags are a powerful feature that allows for presenting calculated values to the user or holding intermediate values for subsequent use Internal tags support most of the available attributes except the ones specifically targeted at PLC tags such as the scale attribute To specify that a Tag is internal use the word INTERNAL instead of a PLC address or Symbolic Tag Protocol AREA PREFIX or TAG INTERNAL Indicates that this tag does not have a link to an actual PLC tag LOCAL Instead it exists only in the app Internal tags can be used to deprecated store and represent intermediate values or expression results Just as regular PLC tags internal tags can have Local or Global scope To identify an Internal tag to have a Global scope just pref
90. s in expressions to achieve special effects Show Hide Product 0 00000 BOOL CE Show Hide Product 1 Show Hide Product 2 Show Hide Product 3 Show Hide Product 4 Show Hide Product 5 Show Hide Product 6 Show Hide Product 7 Show Hide Product 8 ProSoft Technology Inc PARE DAD R September 29 2011 Pre installed Examples ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 10 14 Document Revision History Refer to this section to look at changes on this document over different versions 10 14 1 Version 2 0 0 New styled table of contents Added section Tag Scope Added memory arrays definition in section Specification of Variable Types Mention of how to specify communication protocol in section Specification of Variable Addreses Incorporated references to the new strings type in section Specification of Variable Addreses Added reference for accessing program tags in Logix controllers in section Specification of Variable Addreses Added section Internal Tags Replaced all previous references to Local tags by Internal tags Replaced all previous references to arrays by value lists and text strings by text Added section PLC Memory Arrays New bool barcode and validation tag attributes or styles added to the Tag Attributes section Changed placement of sections Comments in Data S
91. second text Lookup Value group 2 3 Enter value to change third text above Lookup Value group 2 f 5 Enter value to change forth text above ad amp ProSoft Technology Inc Page 97 of 106 September 29 2011 Pre installed Examples ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 10 8 StylesExampleEIP PCCC csv This example shows the available styles and some related tag attributes such as Scale Format Bounds Prefix Suffix as well as the use of lookup tables using EIP PCCC protocol It will run on an AB Micrologix Controller Page 98 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Pre installed Examples Version 2 0 2 User Manual 10 9 AlarmsModbus csv Demonstrates alarm management on a Modbus configuration The example includes both alarms based on tag value and discrete alarms The screenshot on the left shows alarming within the application The screenshot on the right shows an alarm notification from ProSoft i View while it was running in the background which happened while the user was browsing the internet til movistar 15 38 mag Alarms Example LJ Weight Value Linked to several alarms Wgt 7 562 kg Bar Style Weight 7 562 kg Slide to trigger alarms 7562 g ProSoft a 0 5 Group 2 Third alarm in group 2 did Writable Value 7 562 kg become active Change
92. sing expressions in your project you must know the following Tag names in expressions are case sensitive This means that a tag named int value will not be the same as a tag named Int value Logical or Comparison operators assume non zero values to be true and zero values to be false The result of a Logical or Comparison operator is always a value of 0 or 1 Comparison operators are non associative This means that expressions such as value a lt b lt c are not valid You must use value a lt b amp amp b c instead Assignments in expressions are not supported except for assigning values to attributes Therefore expressions such as value condition amp amp int tag 3 will cause a syntax error on the second assignment operator Do not confuse the assignment operator with the the equality operator which is fully supported An expression is executed only when at least one of the referred variables or tags change The process is totally transparent and integrators might not need to know about it However keeping the event driven nature of ProSoft i View in mind can help integrators to understand why and when PLC tags will be written or alarms will trigger as a consequence of an user interaction or PLC Tag change that originated a cascade of change events Expressions containing Logical operators are no exception to the event driven design They will be executed even if a change occurs on the right side of the Logical opera
93. style for writable booleans It displays a boolean variable using a switch control The variable will change its state on each touch Will be ignored if the variable is not writable segment switch Displays an alternative to the switch style for writable booleans button Presents a push button for writing of boolean values Contrary to the switch style the related process variable does not change permanently but goes to 1 true on button press and goes to 0 false on button release bezel Draws a bezel line around a text field for highlighting writable numeric values Note that it is only applicable to writable tags slider Presents a writable tag as a slider control Min and Max values are given with the Bounds attribute bar Presents a read only tag as a bar Min and Max values are given with the Bounds attribute lookup Displays text from a lookup table instead of the actual tag value The tag value is used to determine which entry in the table is shown Note that this attribute will only affect read only tags alarm Tags with this style are not shown in the main tag table Instead they are treated as alarm conditions They may be combined with the Bounds attribute See Alarms page 39 Numeric value determining the order in which pages sections and tags are displayed For more information see Pages Sections Rows and Data Sources page 36 Indicates the minimum access level a user needs in
94. ter than only reading the solicited ones To help on this you can use tags as contiguous as possible and leave the shorter possible gaps between them however note that if you have spared tags that are used in expressions or your users make extensive use of the plotting feature this measure may not be as effective as you might expect or even contraindicated because basically you may not always beat the already optimal set of commands that ProSott i View would generate anyway Tags used in alarms or used in expressions are permanently polled to guarantee interface consistency These tags are also candidates to automatic optimization and applied all the above techniques but since they are read very often they offer the best opportunity for integrators to optimize their project in an user noticeable way As said this is by far the best thing you can do to optimize your project The key is to have as few as possible tags tied to expressions and to keep them in contiguous PLC memory addresses specially with no intercalations of tags that are not used in expressions i e tags that are candidates to be stripped off from readings In other words keep the tags used in expressions or alarms as packed as possible in PLC memory and do not interlace them with the remaining tags Page 86 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Security Version 2 0 2 User Manual
95. tes Additionally international characters are supported in Strings and they can be written and read back from PLCs without breaking their particular encoding There are two ways for using international characters in ProSoft i View Unicode UTF 16 encoding 16 bit multibyte encoding The UTF 16 encoding is capable for representing any character from virtually any language in the wold To make use of this encoding you can do the following Create a source file with texts in your language using your localized version of Excel as usual Export the file as Unicode UTF 16 text Import the file as usual in ProSoft i View ProSoft i View will automatically detect files encoded as UTF 16 Unicode strings will be converted to UTF 8 before storing them on PLC memory NOTE Strings in source files containing UTF 16 characters will be converted automatically to UTF 8 regardless of the Explicit Encoding specified on the source file as defined in the next sub heading Any Explicit string Encoding given in a source file will be thus ignored if the file was already UTF 16 encoded Page 42 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual Explicit Localized encodings 8 bit or multibyte encodings Instead of using UTF 16 you may chose to use one of the 8 bit or multibyte encodings that are commonly used by default on localized
96. that HR1 is a writable BOOL In this case ProSoft i View will use a switch control for that row and will write a value of one 1 or zero 0 to the register depending on user interaction on the switch This applies to all protocols except EIP Native EIP Native does not allow a non BOOL PLC Tag to be treated as BOOL due to the strict type checking that this protocol encourages You can use the bool style instead to force the same effect ProSoft Technology Inc Page 21 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 Accessing Individual Bits in a Register Individual bits in registers can be accessed by using the BOOL type and by specifying a bit address using dot or slash notation depending on protocol see table above ProSoft i View will use the appropriate protocol command to avoid overwriting bits on the register Note that this feature does not apply to EIP Native On EIP Native you can still use the dot notation to access individual bits on variables but due to strict type checking you must set the correct variable type on column B In order to force ProSoft i view to display such values as bools you can use the bool style Note on EIP Native Communication Protocol EIP Native communications do not rely on particular memory locations or positions but on symbolic names With this protocol the user is relieved of the respons
97. the same Page name will belong and be added to a page with such name Similarly the Section name attribute is used to put all variables belonging to the same section under a heading with that name A single attribute the Ord attribute is used to force pages sections and rows to be placed in specific locations Pages and sections are arranged according to their first appearance in the source files based on global order of all variables This is used to force sections and pages to appear in the desired place Variables without an order number will be considered to fall below or after ordered variables but they will maintain their relative positions in the source file How It Works First rows from all selected data source files are sorted from low to high using their Ord attribute As stated above variables with no Ord attribute are moved to the end of the list always keeping their original relative order As sorting is performed the variables Ord numbers are used to determine their page and section position order Pages are arranged in position orders determined by the smaller Ord number of all variables belonging to each page In other words a particular page will be shown in the order given by the Ord number of the first variable belonging to that page Within each page sections are then arranged according to the smaller or first Ord number of all variables belonging to that section and page Finally variables are placed within thei
98. they will become active when the tag goes to 1 true and inactive otherwise just as you would expect Example The following rows in a source file represent the settings for the alarm tags that generated the first and fourth rows on this page Alarm1 INT HR1 label z Group 1 comment Weight Value went above 6 kg style zalarm bounds inf 6 Alarm4 BOOL C1 label Group 2 comment Someone Manipulated the Switch style alarm Performance Considerations Unlike regular tags alarm tags are continuously polled from PLCs even if they are not shown on the screen Also ProSoft i View may continue polling them while running in the background So it is recommended that special care be taken when deciding what tags will be reserved for alarms Particularly it is highly recommended to group alarms in tags as contiguously as possible and to use boolean alarms instead of scalar value alarms as much as possible Arrays of BOOL are the best choice if supported by the protocol Observing this recommendation will lead to shorter communication patterns and less network overhead than if no special care was taken ultimately improving the end user experience 3 1 11 Comments in Data Sources You can comment Rows on Source Files for documental purposes or while you are testing your project To do so just start the row with the character Examples These are the lookup table entries for the style selection texts we are using This ala
99. tor For example the expression value condition1 amp amp condition2 will be always false if condition is false however it will execute anyway as a consequence of a change on condition2 The expression result may not change false but the engine will still send a change event to any referring expressions which could potentially cause other effects such as a PLC tag rewrite if the expression was linked to a PLC tag Expressions are not allowed to create circular or recursive references This means that a result of an expression can not be refitted to another expression that ultimately would send a change event to the originating expression This is not allowed either on the same expression or through intermediate expressions For example the following row int value INT LOCAL value int_value 1 is not valid because the int value tag creates a circular reference around the value expression Expression values are internally stored as double float values 64 bits and all arithmetic and logical operations are performed as double float operations Values read from PLCs including BOOL and INT tags are scaled and converted to double float type before they are used in expressions This has no other relevance than you do not have to care about types type matching or type conversions while using expressions in ProSoft i View Data types in Expressions Variables and Expressions in ProSoft i View support three basic data types Numbers Strings
100. u use custom validation tags you must follow the following points Be sure to have the same validation tag in all files sharing a single connection i e with identical communication settings otherwise one or more files will appear as dissociated on the Connections view f you explicitly set the validation tag attribute to the default one you will still have to do the same in all your files sharing a connection When you explicitly set a validation tag you will have to explicitly set a non zero value for the validation code as using 0 as validation code is explicitly forbidden in this case and doing so will always fail the validation check ProSoft Technology Inc Page 83 of 106 September 29 2011 Security ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 9 2 Background Task Processing You can tell ProSoft i View to keep connections alive even when the device iPhone iPod is locked Additionally ProSoft i View supports running in the background during a finite period of time on multitasking enabled devices On the Settings tab there are two switches that allow for enabling such options allmovistar gt 15 54 Current account administrator Manage accounts gt Access level limit 9 User Interface Paging enabled Hide bottom bar NN NEN Keep connected ETT on ry Settings 9 2 1 Keep Connected When ON ProSoft i View will keep any open connection as
101. ual Numeric operators and methods num operator num2 num to i num to s num to s fmt num chr num abs num round Arithmetic comparison logical operators produce the expected results Available operators are listed on the operators precedence table shown earlier The bitwise and complement operators extract the integral part of the operands before computing the result Example 2 2 returns 4 Returns bit n from the integral part of num Bit 0 is the least significant bit The result can be only 0 or 1 Example 3 0 returns 1 Example 3 1 returns 1 Example 3 2 returns O Returns the integral part of num Example 3 666 to_i returns 3 Returns num Returns a string representation of num optionally formatted according to fmt For a description of possible format specifiers refer to the format function Example 3 666 to_s 02d results in 03 Example 3 666 to_s 02f results in 04 Example 3 666 to_S results in 3 666 Example 25 to_s 02 1f C results in 25 0 C Note that specifying a format in to_s is not a standard feature of Ruby Returns a string containing a single character represented by the character code num Example 72 chr would return H Returns the absolute value of num Example 3 66 abs would return 3 66 Returns num rounded to the nearest integer Example 3 66 round would return 4 ProSoft Technology Inc September 29 2011 Page 53 of 106 Data Source F
102. user interface interface However International Characters and Strings in any language are fully supported Integrators can therefore chose to present their project interface in any language To represent strings the concept of String Encodings is used String Encodings are international conventions that determine how characters representing particular languages are stored into files and device memory ProSoft Technology Inc Page 41 of 106 September 29 2011 Data Source Files ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 English and Western European Languages By default ProSoft i View assumes source files and Strings to conform to the Windows Latini encoding This is adequate for English and most Western European languages such as German French Spanish Portuguese and many others It does not require any particular setting English and Western European versions of Excel on Windows also use the Latin1 encoding for CSV files On Apple Mac computers you must save your CSVs as csv windows format to conform to this encoding The Latin1 encoding is backward compatible with old plain ASCII meaning that ASCII characters share the same codes when represented in Latini encoding String Encoding for International Languages If you use a language that can not be represented with the Latini encoding you are still able to import your files containing international characters in text attribu
103. utes Global attributes are modifiers that apply to all tags or have a meaning in the context of the whole source file Global attributes can be placed anywhere in column D of source files So they can be specified next to any variable and they will still have a global scope Note If a particular global attribute is included more than once in a source file only its first occurrence will take effect Communication settings are global and therefore need to be specified only once in a source file COMMUNICATION ATTRIBUTES TYPE DESCRIPTION Local ip text Source address in text format for local access LAN Example 192 168 1 40 Local port number TCP port used for local connections LAN to this source If it is not specified ProSoft i View will use the standard port for the protocol of the current source file For example 502 for Modbus Note that this can differ from the default port specified in the ProSoft i View Settings tab Remote host text Source address or host name for remote connections Example remote remotehost com Remote port number TCP port used for remote connections to this source WAN Internet If it is not specified ProSoft i View will use the standard port for the protocol of the current source file Ssl number Specifies whether TLS SSL encryption is required for a boolean remote connection Nonzero numeric values are considered true Default value is false Validation_tag Special text Allows
104. value to trigger alarms Wwe PUGAEIIIDS 4 total active alarms Alarm 1 Close View Acknowledge Alarms Group 1 Weight Value went above 6 kg Group 2 Second alarm in group 2 did become active Group 1 Weight Value went below 3 kg ProSoft Technology Inc Page 99 of 106 September 29 2011 Pre installed Examples ProSoft i View Mobile Process Monitoring and Control Application User Manual Version 2 0 2 10 10 AlarmsEIP PCCC csv Identical to the previous one but based on the EtherNet IP PCCC protocol Page 100 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Pre installed Examples Version 2 0 2 User Manual 10 11 ColorfulControlsModbus csv Presents ways to specify colors in tags and controls based on value The example is based on the Modbus TCP IP protocol movistar 16 05 BED ilmovistar gt 16 06 4 Page 1 Page 2 COLORED BUTTONS Push Red to do something _INDICATORS Purple Colored Button Push Purple to do something ane Moisture 68 9 Olive Colored Button Push Olive to do something Light 89 1 STATUS Push Green to do something PURPLE Pone Green Colored Button GJ Temperature Temperature within Default Button Push Button to do something EE normal range COLORED VALUES i Moses Within range high DarkRed Red Default Red DarkRed 239 146 Light Too hi
105. witch segment switch button lookup picker It is the default style for writable booleans It displays a boolean variable using a Switch control The variable will change its state on each touch Will be ignored if the variable is not writable Displays an alternative to the switch style for writable booleans Presents a Push Button for writing of boolean values Contrary to the switch style the related process variable does not change permanently but it goes to 1 true on button press and goes to 0 false on button release Draws a bezel line around a text field for highlighting writable numeric values Note that it is only applicable to writable tags Presents the tag as a boolean even if it is not of type BOOL limiting the possible values to 0 or 1 It also activates related attributes such as on label and off label and brings the special meanings of some attributes for bool types Presents a tag as a slider control or a bar depending on whether it is writable Min and Max values are given with the bounds attribute Both are identical and can be used indistinctly Displays a text from a lookup table instead of the actual tag value The tag value is used to determine which entry in the table is shown This attribute will work both on read only tags and writable tags On writable tags the bounds attribute is used to determine which range on the lookup table will be made available to t
106. with to s The resulting individual strings are embedded into an array and then joined by means of the the join method using as separator Given the following two rows X DINT HR1 label Total Seconds t STRING INTERNAL label Time value x 3600 to_s 02d x 3600 60 to_s 02d x 60 to_s 02d join when HR1 holds 3661 which is 3600 seconds 1 hour 60 seconds 1 minute 1 second the second row will display 01 01 01 Instead of using the join method we could have used the format function in a posibly more convenient way Consider the following value format 02d 02d 02d x 3600 x 3600 60 x 60 in this case the format specifiers in the format string are just replaced with the relevant time values Calculating seconds from a string having the hh mm ss format Just to illustrate what expressions allow to do let s try now to get the original seconds value from a string already in the hh mm ss format To do so we can use the following expression value 3600 t split fetch 3 0 to i 60 t split fetch 2 0 to_i t split fetch 1 0 to_i Page 58 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual In this case we extract separately the hours minutes and seconds as numeric values from the string we multiply them by 3600 60 and 1 respectiv
107. ws for managing uploading and downloading files into ProSoft i View through an embedded Web Server 2 1 3 Files Only available to the Administrator user Presents a list of source files containing tag definitions and allows for placing a selection of the relevant ones for an application 2 1 4 Connections Available to all users but with restricted options for non Administrator users Presents a series of entries called connections that represent actual links to PLCs Within each connection you can check the communication status and set validation codes Relevant communication settings and parsing information is presented for source files related to each connection You can also switch monitoring ON or OFF from this section Non Administrator users are allowed only to switch monitoring ON or OFF from this tab Connections are hidden for these users 2 1 5 Home This is the main view and the place where actual tags and tag values are presented It is available to all users but access levels on tags are applied depending on the current source files configuration so what each user views may vary Trend graphs and alarms are also displayed in this tab 2 2 Variables in ProSoft i View Process variables or tag values coming from PLCs are organized in ProSoft i View as a list with sections in a way similar to the iPhone Contacts Application The specific display may vary depending on variable type style and other characteristics Pag
108. y an index Array indexing starts at 0 A negative index is assumed relative to the end of the array that is an index of 1 indicates the last element of the array 2 is the next to last element in the array and so on Arrays can hold any objects such as Numbers Strings or other Arrays Arrays can be read from or written to PLC or can be created on demand in expressions by just enclosing their elements in square brackets Example element at index 0 123 4 33 temperature The above expression represents an array of three elements At index 0 we have a literal string element at index 0 At index 1 we have a numeric value 123 4 At index 2 we have an array of 2 elements with the number 33 and the variable temperature as their components Elements of the referred array can be accessed by index as shown next element at index 0 123 4 33 temperature 1 would return 123 4 element at index 0 123 4 33 temperature 3 would return element at index 0 element at index 0 123 4 33 temperature 1 0 would return 33 element at index 0 123 4 33 temperature 2 1 would return the value of temperature Page 50 of 106 ProSoft Technology Inc September 29 2011 ProSoft i View Mobile Process Monitoring and Control Application Data Source Files Version 2 0 2 User Manual Operators and Operator Precedence The following table shows the available operators and its precedence The t

Download Pdf Manuals

image

Related Search

Related Contents

レコドライ - LECOジャパン  HP Pavilion 15-p061ne  Plaquette SMARTY FORCE FR_Mise en page 1  Operating Instructions Diagnostic Set  MANUEL D`INSTALLATION ET DE MAINTENANCE  LG 47LM5800 Energy Guide : Free Download, Borrow, and Streaming : Internet Archive  Anleitung Vodafone 736  AC1500  TransPocket 2000  VSBDemod User`s Manual  