Home
USER MANUAL
Contents
1. g gt Dg Longo programmable controller LPC 2 NE1 module Table 1 K3 communication port SMARTTEH LIVING SYSTEMS ETH 1 Tx data transmit wire pair ETH 2 Tx data ETH 3 Rx data f receive wire pair ETH 6 Rx data Table 2 internal bus K1 Data amp DC power supply Connection to other comm module K2 Data amp DC power supply Connection to controller or another comm module Table 3 marking and indication OFF no power supply ON power supply present RUN LEDA status UART communication to LPC 2 MC7 not active BLINK ON every 4s for 1s power supply present UART communication to LPC 2 MC7 active ON power supply present LED2 Rx no ethernet packet received BLINK OFF packet received OFF LED2 amp LED3 no power supply present ON power supply present LED3 TX no ethernet packet received BLINK OFF packet send OFF LED2 amp LED3 no power supply present available only on products produced after maj 2007 ms Longo programmable controller LPC 2 NE1 module SMARTTEH LIVING SYSTEMS 3 2 Mounting instructions Figure 3 Housing dimensions ai aa L o L e Dimensions in millimeters All connections module attachments and assembling must be done while module is not connected to the main power supply Mounting instructions
2. 1 Switch OFF main power supply 2 Mount LPC 2 NE1 module to the provided place inside an electrical panel DIN EN50022 35 rail mounting to the left side of the LPC 2 controller module 3 Mount other LPC 2 modules if required Mount each module to the DIN rail first then attach modules together through K1 and K2 connectors Connect devices and sensor wires according to the connection scheme in Figure 2 Switch ON main power supply LED1 and LED2 should light on according to the Table 3 Dismount in reverse order For mounting dismounting modules to from DIN rail a free space of at least one module must be left on the DIN rail NOTE LPC 2 MC7 main control module should be powered separately from other electrical appliance connected to LPC 2 system Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard LONGO programmable controller LPC 2 NE1 module SMARTTEH LIVING SYSTEMS 3 3 Module labeling Figure 5 Labels Label 1 Label 2 LPC 2 NE1 P N 225NE106001001 S N NE1 S9 0800000003 D C 40 08 Label 3 MAC 20 41 5A 1A 00 0C Label 1 description 1 LPC 2 NE1 is the full product name 2 P N 225NE106001001 is the part number e 225 general code for LPC 2 product family e NEI short product name e 06 year of code opening e 001 derivation code e 001 version code reserved
3. for future HW and or SW firmware upgrades 3 D C 40 08 is the date code e 40 week of production e 08 year of production Label 2 description 1 S N NE1 S9 0800000003 is the serial number e NE1 short product name e _S9 user code test procedure e g Smarteh person xxx e 08 year last two cyphers e 00000003 current stack number previous module would have the stack number 00000002 and the next one 00000004 Label 3 description 1 20 41 5A 1A 00 0C is a unique MAC dedicated to each NE1 module e 20 41 5A 24 bit first portion is the OUI value assigned to Smarteh by the IEEE Registration Authority e 1A 00 0C 24 bit second portion is the OUI value assigned by Smarteh oa Ee Longo programmable controller LPC 2 NE1 module SMARTTEH LIVING SYSTEMS 4 OPERATION 4 1 IP and MAC setting Module uniquely assigned MAC is not saved in NE1 module memory MAC belonging to each module is written on the label on the housing Module gets its IP amp MAC parameters from PLC application therefore this values should be used in application running in the main control unit to which module is attached This parameters are configured with following variables variable name value NE1_x_IP1 most significant byte of IPv4 address notation NE1_x_IP2 d NE1_x_IP3 NE1_x_IP4 least significant byte of IPv4 address notation NE1_x_MAC1 first hex noted pair of OUI 48 bit MAC notation NE1 x MAC2 second hex noted pair
4. 2 MOUNTING iAStructiohs an e a u rere tone uesess 5 3 3 Module CH le BE 6 4 OPERATION ee een 7 4 1 IP and MAC setting rennen nn 7 4 2 Modbus protocol USE ke ee 7 5 TECHNICAL SPECIFICATIONS wis nn 9 LR TEE 10 NOTES a edlen 11 5 nt _ 5 Longo programmable controller LPC 2 NE1 module SMARSFEH 1 DESCRIPTION LPC 2 NE1 Ethernet module is intended to connect LPC 2 standalone system with LAN It acts as Modbus slave device using TCP IP protocol IP and MAC addresses are configurable from main controller module application NOTE For proper system configuration and data allocation please refer to LPC Composer software help menu SMARTTEH mm LONGO programmable controller LPC 2 NE1 module LIVING SYSTEMS 2 FEATURES sch CEA LPC 2 NET Ethernet Adar ETH 87654321 Figure 1 LPC 2 NE1 communication module Table 1 Technical data Compliant to Ethernet Il and IEEE802 3 10Base5 10Base2 10BaseT 10Mbps IP and MAC address management Modbus slave device mode TCP IP protocol Modbus commands support 3 diagnose LEDs Standard DIN EN50022 35 rail mounting mm Longo programmable controller LPC 2 NE1 module SMARTTEH 3 INSTALLATION 3 1 Connection scheme example Figure 2 Connection scheme example FUSE Ek 63mAT SMART Main LPC 2 MC7 C Run Bi 2 ae ki ae LAN device Ee
5. UTO64 64 NE1_x_wiN001 Holding register 16 bit 1 0x06 NE1_x_wINOO2 lt lt size 2 gt gt 0x01 S lt lt 0x03 NE1_x_wiN064 64 _ 5 SMARTTEH LIVING SYSTEMS Longo programmable controller LPC 2 NE1 module 5 TECHNICAL SPECIFICATIONS Table 5 Technical specifications Power supply from internal BUS Power consumption 0 5 W Connection type suitable mating Dimensions L x W x H RJ45 FM connector RJ45 male cable connector 90 x 18 x 60 mm Supported protocol Modbus TCP slave Weight 50 g Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Maximum altitude 2000 m Mounting position vertical Transport and storage temperature 20 to 60 C Pollution degree 2 Protection class IP 30 sens _ 5 Longo programmable controller LPC 2 NE1 module SMARTTEH LIVING SYSTEMS 6 CHANGES The following table describes all the changes to the document Date V Description 1 7 2012 004 CGP General update 11 5 2010 003 Updated warranty permanence 23 3 2010 002 added Label 3 description 23 4 2007 001 The basic version issued as User Manual user manual 10 LONGO programmable controller LPC 2 NE1 module SMARTTEH LIVING SYSTEMS 7 NOTES
6. a A amp SMARTEH LIVING SYSTEMS USER MANUAL Longo programmable controller LPC 2 NE1 module Version 4 SMARTEH doo Trg tigrovcev 1 5220 Tolmin Slovenia Tel 386 0 5 388 44 00 e mail info smarteh si www smarteh si LONGO programmable controller LPC 2 NE1 module SMARTTEH LIVING SYSTEMS Written by Smarteh d o o Copyright 2012 SMARTEH d o o User Manual Document Version 004 July 1 2012 LONGO programmable controller LPC 2 NE1 module SMARTTEH LIVING SYSTEMS STANDARDS AND PROVISIONS Standards recommendations regulations and provisions of the country in which the devices will operate must be considered while planning and setting up electrical devices Work on 230 VAC network is allowed for authorized personnel only DANGER WARNINGS Devices or modules must be protected from moisture dirt and damage during transport storing and operation WARRANTY CONDITIONS For all modules LONGO LPC 2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power we offer warranty for 24 months from date of sale to end buyer In case of claims within warranty time which are based on material malfunctions the producer offers free replacement The method of return of malfunctioned module together with description can be arranged with our authorized representative Warranty does not include damage d
7. of OUI 48 bit MAC notation NE1_x MAC6 last hex noted pair of OUI 48 bit MAC notation 4 2 Modbus protocol usage LPC 2 NE1 Ethernet adapter is Modbus slave device and supports Modbus commands as defined in protocol specification V1 1a using TCP IP protocol RTU transmission mode ISO OSI model Device address supported by LPC 2 NE1 module Coils bit 128 Registers word 64 Functions supported by LPC 2 NE1 module 01 0x01 Read Coils 0x02 Read Discrete Inputs 0x03 Read Holding Registers 0x04 Read Input Registers 0x05 Write Single Coil 0x06 Write Single Register OxOf Write Multiple Coils e 16 0x10 Write Multiple Registers NOTE If Modbus parameters are not valid illegal address module replies with exception code response 2 3 al 5 6 5 For better understanding of Modbus protocol refer to www modbus ida org and Modbus Application Protocol V1 1a pdf document LONGO programmable controller LPC 2 NE1 module SMARTTEH LIVING SYSTEMS Memory layout LPC 2 ETHERNET LPC 2 NE1 direction memory sector modbus direction Modbus variable address functions NE1_x_bOUTOO1 Discrete input bit size 1 0x02 NEI x bOUTOO02 gt gt 2 gt gt NEI x bOUT128 128 NE1_x_bINOO1 Coil bit size 1 0x05 NE1_x_bINOO2 lt lt 2 gt gt OxOF S lt lt 0x01 NEl_x_bIN128 128 NEI x wOUTOO1 Input register 16 bit size 1 0x04 NE1 x_wOUT002 gt gt 2 gt gt NE1_x wO
8. ue to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVICE THIS PRODUCT YOURSELF This device must not be installed in the systems critical for life e g medical devices aircrafts etc If the device is used in a manner not specified by the manufacturer the degree of protection provided by the equipment may be impaired gt Waste electrical and electronic equipment WEEE must be collected separately LONGO LPC 2 complies to the following standards EMC IEC 61131 2 LVD IEC 61131 2 Vibrations and climatic mechanical EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 Smarteh d o o operates a policy of continuous development Therefore we reserve the right to make changes and improvements to any of the products described in this manual without any prior notice MANUFACTURER SMARTEH d 0 0 Trg tigrovcev 1 5220 Tolmin Slovenia LONGO programmable controller LPC 2 NE1 module SMARTTEH LIVING SYSTEMS Index Longo programmable controller LPC 2 NEl module LES CRIE ue RS a ee 1 2 FEATURES de eee nait 2 INSTALLATIONS ann en tenant nn cran 3 3 1 Connection scheme example 3 3
Download Pdf Manuals
Related Search
Related Contents
RomiApex™ A-15 SIDE- POWER - SAILTEC GmbH MF4 FR1600 - AiM Sportsystems 5GHz Outdoor Router User Manual Delta Electronics KPE-LE02 User's Manual 取扱説明書 - フジ医療器 Samsung GT-S5229 User Manual advarsel! - Center for Detectors Operator`s Manual micristar - TMC Services Inc. Copyright © All rights reserved.