User`s Manual InfraRed Thermometer with Laser Pointer
Contents
1. A automatically compensates for ambient temperature deviations however it may take up to 30 minutes to adjust to extremely wide ambient temperature changes 2 When low temperature measurements are taken followed by high temperature measurements several minutes are required for stabilization before the high temperature measurements can be made accurately 3 Measurement Field Distance For optimum accuracy the object should be 1 5 to 2 times larger than the spot size shown in the diagram above and on the meter side 4 Measurement Interference Objects having low emissivity or objects with low 5 6 temperature yet high emissivity emit little IR energy Such objects are adversely affected by IR energy radiated from nearby objects having high emissivity and temperature For example when such objects are measured in sunlight erratic readings occur because of the powerful radiation sunlight reflected off of the object s surface into the 42525A sensor If the surface of the object under test is covered with frost oil grime etc clean before taking measurements If an object s surface is highly reflective apply masking tape or flat black paint emissivity 0 95 before measuring 5 Model 42525A Version 3 5 12 04 Emissivity Considerations and Adjustment The amount of IR energy emitted by an object is proportional to an object s temperature and its ability to emit energy This ability is known as emissivity Emissivity is de
2. User s Manual EXTECH INSTRUMENTS InfraRed Thermometer with Laser Pointer MODEL 42525A RARED Type K INF ERMOMETER Introduction Congratulations on your purchase of Extech s 42525A IR Thermometer The Model 42525A provides non contact IR and contact type K temperature measurement capability The built in laser pointer activated by pressing the meter s trigger increases target accuracy The Model 42525A has an RS 232 PC Interface jack for recording readings as they are taken Professional features include EMISSIVITY ADJUST RELATIVE MODE DATA HOLD DISPLAY OFFSET and MIN MAX DISPLAY Proper use and care of this meter will provide years of reliable service Safety 1 Use extreme caution when the laser beam is ON 2 Do not point the beam toward anyone s eye 3 Be careful not to let the beam strike the eye from a reflective surface 4 Do not use the laser near explosive gases or in other potentially explosive areas CAUTION o Laser Radiation One Year Limited Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies to sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website www extech com for conta
3. a C A ae ay KL aaa a ay a ur 11 4 Model 42525A Version 3 5 12 04 Operating Instructions Infrared Measurement Procedure 1 Turn the meter ON by pressing the POWER button The meter display will countdown 99999 88888 77777 00000 during the self test procedure When the self test is complete the display will indicate a temperature reading the unit of measure the emissivity setting and the measurement type IR for non contact or Type K for contact measurements Use the IR TYPE K button to set the display to the IR mode IR will appear in the lower left hand side of the LCD Set the temperature units C or F using the C F button Point the IR sensor toward the object under test to assist with targeting press the meter trigger to activate the laser pointer This meter has a distance to spot ratio of 6 1 Use the diagram below to determine the proper distance to hold the meter from an object For example if the object under test has a diameter of 4 hold the meter at a distance of approximately 26 Read the LCD display for the temperature measurement Note that the current emissivity setting is shown on the lower right hand corner of the LCD Diameter of Spot 150 125 100 75 30 mm OOOO Q O 1000 840 670 500 330 mm 40 33 26 4 20 13 inch Distance to Object ao ee ss quae eat wn Infrared Measurement Considerations 1 The 42525
4. ct information A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied 2 Model 42525A Version 3 5 12 04 Specifications General Specifications Display Sample rate Over range indication Laser pointer Max Min Recording Data output Operating Temperature Operating Humidity Power Supply Dimensions 04 10mm 5 digit LCD display RS 232c PC Interface for use with Windows based communications programs Connection via 3 5mm phono jack on side of meter 17 7 x4 7 x 2 3 195 x 120 x 58 mm Infrared Thermometer Specifications Range Resolution Accuracy Accuracy notes 4 to 752 F 20 to 400 C 0 4 C F 3 of reading or 6 F 3 C whichever is greater 1 Accuracy specified for rea
5. dings between 10 and 350 C 2 Accuracy specified for ambient temperature 23 C 5 C 3 Accuracy specified for an emissivity of 0 95 4 Accuracy tested using 2 25 diameter black body at a distance of 6 _5 Testing environment RF field strength lt 3 V M and frequency lt 30MHz 0 20 to 1 00 factory default 0 95 Accuracy specified 23 5 C Thermocouple characteristics are not reflected in the Accuracy specs Linearity correction stored in CPU Type K NiCr NiAl Thermocouple sold separately Connects to _thermocouple jack on side of meter 3 Model 42525A Version 3 5 12 04 Meter Description 2s ee eS 10 11 LCD Display Function buttons e C F Button also the UP button Used to select temperature units Also used as an UP arrow button for setting the emissivity value e Emissivity button Enter the emissivity adjustment mode e Relative button also the DOWN button Used to access the RELATIVE mode of operation Also used as the DOWN arrow button for setting the emissivity e Record button Used when viewing the MAX and MIN readings e Data Hold button Used to freeze the displayed reading POWER button Turns meter ON or OFF IR Type K button Selects IR non contact or Type K contact operation RS 232 PC Interface jack IR Sensor Laser pointer Type K input jack Laser pointer trigger Handle grip Battery Compartment RS232 K RARED Type N ERMOME TER a ar
6. er temperatures are different several minutes should be allotted so that the temperature of the socket matches the temperature of the thermocouple The cold junction compensation circuitry can then operate efficiently allowing the meter to provide measurements with optimum accuracy Auto Power Off The meter will automatically power off after approximately 10 minutes in both IR and Thermocouple measurement modes To disable this feature press the REC button RS 232 Serial PC Interface This instrument includes a built in RS 232 serial data port This interface is intended for use with the optional Data Acquisition Software and Cable PN 407752 For more information contact Extech or refer to the manual accompanying the 407752 software package 7 Model 42525A Version 3 5 12 04 Maintenance Battery Replacement When the low battery symbol appears on the LCD replace the meter s 9V battery The battery compartment is located on the bottom of the meter s handle Open the compartment by sliding the battery compartment cover off Replace battery and re install the battery compartment cover Cleaning Wipe meter with a damp cloth when necessary A mild detergent may be used but avoid solvents abrasives and harsh cleansers Do not allow moisture inside the meter Storage Remove the battery if the meter is to be stored for long periods Do not store the meter in an environment that exceeds the published operating temperature and hum
7. idity specifications Calibration and Repair Services Extech offers complete repair and calibration services for most products we sell For periodic calibration NIST certification or repair of most Extech products call customer service for details Extech recommends that calibration be performed on an annual basis to insure calibration integrity Copyright 2004 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form 8 Model 42525A Version 3 5 12 04
8. mic 0 90 to 0 94 Paper 0 70 to 0 94 Marble 0 94 Chromium Oxides 0 81 Plaster _ 0 80 to 0 90 ff Copper Oxides 0 78 Mortar 0 89 to 0 91 ff Iron Oxides 0 78 to 0 82 Brick 0 93 to 0 96 Ff Textiles 0 90 Data Hold Press the HOLD button to freeze the displayed measurement The HOLD icon will appear on the LCD to indicate that the Data Hold mode is activated Press the HOLD button again to exit the Data Hold mode and return to normal operation Relative Measurements While measuring press the REL button to activate the Relative Mode REL will appear on the LCD in the upper right hand corner The measurement on the LCD at the time of the button press will be displayed as 0 0 Subsequent readings will be displayed as a difference between the stored reading and the actual reading Relative does not function when either Data Hold or Data Record is enabled 6 Model 42525A Version 3 5 12 04 Max Min Recording The Max Min Recording feature offers the user to view only the highest maximum MAX or the lowest minimum MIN reading Press the REC button once to activate this feature the REC symbol will appear on the LCD Press the REC button again to view only the maximum reading MAX Press the REC button again to view only the minimum reading MIN Press and hold the RECORD button again until the REC MAX MIN icons switch off to return to normal operation Laser Pointer Operation This 42525A is equipped with a laser pointe
9. r that is used to aim the IR sensor more accurately Simply press the meter trigger to activate the laser pointer Be extremely cautious when directing the laser beam shining the laser beam into someone s eye can cause serious injury Point the laser beam toward the device under test whose temperature is to be measured Offset Adjustment The OFFSET function allows the user to adjust the temperature readings in fine detail to match an external calibrator to compensate for display drift or for other diagnostic uses Press and hold the HOLD and the REC buttons simultaneously The small digits on the lower right will match the temperature display of the larger digits when the two buttons are held down correctly While continuing to hold down the two keys press the UP or DOWN buttons to set the offset value on the larger digits Release all keys to return to normal operation Type K Thermocouple Measurement Procedure 1 Connect a Type K Thermocouple to the temperature input jack on the meter Power the meter by pressing the POWER button Use the IR TYPE K button to select Type K mode display will show K Set the temperature units degrees C or F using the C F button Place the Thermocouple in the area where the temperature is to be measured Read the LCD display for the temperature measurement ot oF oe Type K Measurement Considerations When a Type K Thermocouple is first connected to the meter and the thermocouple and met
10. termined by the material of the object and the object s surface finish Emissivity values range from 0 1 for a very reflective object to 1 00 for a flat black finish The Model 42525A uses a factory default emissivity setting of 0 95 this setting covers most applications The closer the meter s emissivity setting is to the actual emissivity of the object under test the more accurate the temperature measurements will be To calculate the emissivity of an object Measure an object s temperature using a Type K Thermocouple use of a surface mount thermocouple works best for this purpose and note the reading Measure the object again using the IR sensor Now set the emissivity so that the IR measurement matches the thermocouple reading To set the emissivity 1 Press and hold the Emissivity button until the emissivity display starts to flash 2 Use the UP DOWN arrow buttons to select the desired emissivity 3 Press and hold the Emissivity button until the display stops flashing to exit Emissivity Factors for Common Materials Material under test Emissivity Material under test Emissivity Asphalt 0 90 to 0 98 Cloth black 0 98 Concrete 0 94 Skin human 0 98 Cement 0 96 Lather 0 75 to 0 80 Sand 0 90 Charcoal powder 0 96 Soil 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 If Timber 0 90 Cera
Download Pdf Manuals
Related Search
Related Contents
Ne laissez pas le hasard choisir à votre place. Rejoignez la exemple de rapport en PDF PART A: USER GUIDE - Department of Social Services Manual do usuário Tripp Lite TLP78TUSBG surge protector Español HipServ Web Services API v0.1 Transdutor de separação Saída Circuito de campo Ex i Copyright © All rights reserved.