1. Detergents SAM 1 2017 O to 2 50 PPM mg Liter AC CHEMetrics Water Analysis Systems Battery Replacement Battery Compartment Cover B Seal Ring A Instrument Back Screws Batteries Notch To ensure that the instrument is waterproof seal ring A must be in position e battery compartment cover B must be fixed with the four screws To Set Zero 1 Press the Power key 2 The display will show det 3 Insert the ZERO test tube supplied in detergents test kit filled with distilled or deionized water into the sample cell compartment with mild downward pres sure making sure that it is fully seated 4 Place the light shield over the ZERO test tube 5 Press the Zero Test key The det symbol will flash for approximately 8 sec onds then the display will show 0 0 0 To Make a Measurement 1 Follow the Test Procedure in the Instrumental Detergents Test Cat R 9423 2 Insert the resulting Detergents test tube into the sample cell compartment with mild downward pressure making sure that it is fully seated 3 Place the light shield over the test tube 4 Press the Zero Test key The det symbol will flash for approximately 3 sec onds then the sample test results will appear in the display as ppm mg Liter Operating Tips e Upon startup the photometer automatically proceeds to the zeroing process Every time the photometer powers on it must be re
2. on use Optics 660 nm LED interference filter and photosensor in transparent sample chamber Operating Temp 5 to 40 C 41 to 104 F Battery 4 AAA batteries approx 5 000 tests or 17 hours Waterproof Floating IP68 1 hour at 0 1 meter Wavelength Accuracy 1 nm Photometric Accuracy 3 full scale T 20 25 C 68 77 F Photometric Resolution 0 01A Ambient Conditions Temperature 5 40 C 41 104 F Rel humidity 30 90 non condensing CE Certificate of Declaration of CE Conformity available upon request Measured with Standard Solutions 1 2 oO Menu Selection Hold the Mode key down and press the On Off key Allow the 3 decimal points to appear in the display before releasing the Mode key Use the key to toggle through 2 menu options Store recall stored data Date amp Time setting the date and time Press the Mode key to select the menu option that is indicated by the arrow Note Ifthe instrument is already on press and hold the key for more than 4 seconds to access the recall menu Recall of Stored Data The colorimeter shows the last 16 data sets in the following format Sample Number nXX XX 16 15 14 1 Year XXXX e g 2009 Date mm dd e g 07 31 Time hh mm e g 12 05 Result XX or XXX The Zero Test key repeats the current data set The Mode key scrolls through all stored data Quit the menu by pressing the key Setting Date and Time The setting start
3. s with the year XXXX then month XX then day XX then hour XX then minutes XX Increase value by pressing the Mode key Decrease value by pressing the Zero Test key Proceed to the next setting by pressing the key After setting the minutes and pressing the key the display will show IS SET and return to measurement mode www chemetrics com 4295 Catlett Road Midland VA 22728 U S A Phone 800 356 3072 Fax 540 788 4856 E Mail orders chemetrics com Nov 13 Rev 9
4. zeroed To re zero the photometer it must be turned off and back on again e A series of readings can be taken without re zeroing as long as the photome ter stays on during the series e Protect photometer from extreme humidity corrosive fumes and dusty areas Store in a cool dry place e Remove the batteries when photometer is not in use e Press the key to turn the display back light on or off e When moving the photometer from one temperature extreme to another wait at least 10 minutes before use to allow photometer to come to temperature equilibrium e Contamination of the optics in the sample chamber will result in incorrect meas urements The windows in the sample chamber should be checked at regular intervals and cleaned as necessary Use a soft moist cloth or cotton swab for cleaning purposes If the sample cell adapter has been removed it must be replaced with proper orientation aligning the triangle on the adapter with the triangle on the pho tometer Displays and Troubleshooting E01 Light absorption too great dirty optics E20 E21 Too much light reaching detector E22 or Battery Icon Battery should be replaced E27 E28 E29 Instrument zeroed incorrectly misaligned adapter test tube not properly seated dirty optics or failing light source Hi E03 Measuring range exceeded or excessive turbidity Lo Test result has a negative value less than 0 ppm Specifications Auto Shutoff After 15 minutes of n
Download Pdf Manuals
Related Search
Related Contents
Ellllllll IHSPRXR Aluratek AHDVC01F User's Manual Disyuntores MT Interruptores automáticos LF y SF hasta 40,5 kV SOGILUB.NET CLICKFREE HD SERIES USER MANUAL - Gatti Brother 1840C All in One Printer User Manual Not for Reproduction User Manual - Ozarks Audio Visual Internal report - PURE Copyright © All rights reserved.
Failed to retrieve file