Home
SBO500 User Manual 1.6.2
Contents
1. Check No Destination Subnet Mash Network Port Modify O D 12 12 0 0 255 255 0 0 NET 2 e O 1 201 123 112 0 255 255 255 0 NET 1 La Clear All Add New Figure 3 50 Routing Table List Click Modify in Figure 3 50 to modify a routing See Figure 3 51 for the routing table modification interface The configuration items on this interface are the same as those on the Add Routing Table interface Note that the item No cannot be modified Routing Table No Destination 12 12 0 0 subnet Mask 255 255 0 0 Network Port MET 2 Figure 3 51 Routing Table Modification Interface To delete a routing check the checkbox before the corresponding index in Figure 3 50 and click the Delete button To clear all number manipulation rules at a time click the Clear All button in Figure 3 50 SMG SBO Series Gateway User Manual Version 1 6 2 Page 47 Cvnwav Synway Information Engineering Co Ltd 3 7 4 SNMP Contig SNMP Confiauration Enable SNMP SNMP Server Address M27004 Monitoring Part 161 Community String Configuration Read only Community String Figure 3 52 SNMP Configuration Interface See Figure 3 52 for the SNMP configuration interface If the SNMP feature is enabled once the gateway receives a request from the SNMP management software it will collect relevant information and reply to the SNMP management software By default the SNMP feature is disabled The available information include
2. Original CalleelD Pool in Blacklist nane ze Description default Figure 3 40 Modify Filtering Rule Interface To delete a filtering rule check the checkbox before the corresponding index in Figure 3 38 and SMG SBO Series Gateway User Manual Version 1 6 2 Page 39 ynway Synway Information Engineering Co Ltd click the Delete button To clear all filtering rules at a time click the Clear All button in Figure 3 38 3 6 Number Manipulation Number Manipulation includes two parts IP gt IP CallerlD and IP IP CalleelD See Figure 3 41 FF Num Manipulate A IP IP CallerID IP IP CalleelD Figure 3 41 Number Manipulation 3 6 1 IP to IP CalleriID By default there is no IP gt IP CallerlD manipulation available on the gateway Click Add New to add them manually See Figure 3 42 for the IP gt IP CallerlD manipulation rule adding interface IP 1P C allerlD Manipulation Index Call Initiator SIP Trunk Group 0 CallenlD Pretix CalleelD Prefix With Original CalleelD stripped Digits from Left stripped Digits from Right Reserved Digits from Right Prefix to Add Suffix to Add Description default Figure 3 42 Add IP gt IP CallerID Manipulation Rule SMG SBO Series Gateway User Manual Version 1 6 2 Page 40 ynway Synway Information Engineering Co Ltd The table below explains the items shown in the above figure wm Desrpion o The unique index of each number m
3. To delete a SIP register check the checkbox before the corresponding index in Figure 3 14 and click the Delete button Check All means to select all available items on the current page Uncheck All means to cancel all selections on the current page Inverse means to uncheck the selected items and check the unselected To clear all SIP registers at a time click the Clear All button in Figure 3 14 3 3 4 SIP Account By default there is no SIP account available on the gateway Click Add New to add them manually See Figure 3 16 SMG SBO Series Gateway User Manual Version 1 6 2 Page 23 ynway Synway Information Engineering Co Ltd SIP Account SIP Trunk No Lisername Password Register Expires ei 38500 Authentication Username Description default Figure 3 16 Add New SIP Account The table below explains the items shown in above figures mem 0 escription The unique index of each SIP account SIP Trunk No The number of the SIP trunk to which the SIP account is registered The registration username of the SIP account Once the SIP account is successfully Username m registered the SIP server can initiate calls to the gateway via Username The registration password of the SIP account To register the SIP account to the SIP Password mE m trunk both configuration items Username and Password should be filled in The validity period of the SIP account registry Once the registry is overdue the S
4. Original CalleelD Fool in Blacklist none Description default Figure 3 39 Add New Filtering Rule The table below explains the items shown in the above figure wei Deepen No Thecomespondigmumber orafitengrue Thevaluerangeis 0 99 Whitelist pool in whitelist Blacklist pool in blacklist Whitelist pool in whitelist SMG SBO Series Gateway User Manual Version 1 6 2 Page 38 ynway Synway Information Engineering Co Ltd Blacklist pool in blacklist Pool in Whitelist CalleelD pool in whitelist Original CalleelD Select a Group No which is set in the blacklist from the number pool as the original Pool in Blacklist CalleelD pool in blacklist Description Remarks for the filtering rule It can be any information but can not be left empty After configuration click Save to save the above settings into the gateway or click Close to cancel the settings Click Modify in Figure 3 38 to modify the filtering rule See Figure 3 40 for the filtering rule modification interface The configuration items on this interface are the same as those on the Add New Filtering Rule interface Filtering Rule No CallerlD Whitelist 0 CalleelD Whitelist none CallerlD Blacklist none ce 4 4 4 4 CalleelD Blacklist none CallerlD Poolin Vvhitelist 0 Caller Fool in Blacklist none CalleelD Fool in Whitelist none CalleelD Poolin Blacklist none Original CalleelD Pool in Whitelist 0 d
5. oee Figure 3 35 for the Number Pool Setting interface A new number pool can be added by the Add New button on the bottom right corner of the list in the above figure See Figure 3 36 for the Number Pool adding interface Number Pool Group Ma in Graup starting Number Humber Amount Figure 3 36 Add New Number Pool The table below explains the items shown in the above figure Group Starting Number Number Amount After configuration click Save to save the above settings into the gateway or click Close to cancel the settings SMG SBO Series Gateway User Manual Version 1 6 2 Page 36 Cvnway Synway Information Engineering Co Ltd Click Modify in Figure 3 35 to modify the number pool See Figure 3 37 for the number pool modification interface The configuration items on this interface are the same as those on the Add New Number Pool interface Number Pool Group No in Group Starting CallerlD Number Amount Figure 3 37 Modify Number Pool Interface To delete a number pool check the checkbox before the corresponding index in Figure 3 35 and click the Delete button To clear all number pools at a time click the Clear All button in Figure 3 35 3 5 4 Filtering Rule Check No CallerlD Whitelist CalleelD Whitelist CallerlD Blacklist CalleelD Blacklist CallerlD Pool in Whitelist CalleriD Pool in Blacklist CalleelD Pool in Whitelist CalleelD Pool in Blacklist Original Cal
6. There Traversal Type is only one traversal type Port Mapping The mapping addresses of LAN1 and LAN 2 in case the NAT traversal is enabled If LAN1 Mapping Address LAN2 Mapping Address the port mapping is selected as the traversal type you are required to set the mapping address and port on the router and fill in the corresponding information here as well SIP Transport There are two modes UDP and TCP available for running the SIP protocol The Protocol default value is UDP Once this feature is enabled you can encrypt the SIP signal following selecting an SIP Encryption A u encryption criterion and setting a key By default it is disabled Encryption Criterion The criterion used to encrypt the SIP signal At present only VOS1 1 is supported Key The key to encrypt the SIP signal f Once this feature is enabled you can encrypt the RTP package By default it is RTP Encryption n isabled When this feature is enabled the RTP reception address or port carried by the signaling message from the remote end if not consistent with the actual state will RTP Self adaption be updated to the actual RTP reception address or port By default this feature is disabled UDP Header When this feature is enabled the gateway will automatically calculate the check When this feature is enabled a corresponding Rport field will be added to the Via message of SIP By default it is disabled Sets whether to enable the DSCP dif
7. Trunk Gidup 2 none SIP Trunk Group 2 default s numberFiter x ES SE n FF Num Manipulate v alae West Mnene SEEE AGA Add New 3ltems Total 20ltems Page 1 1 First Previous Next Last GotoPage 1 1 Pages Total IN System Tools Y Figure 4 6 6 Set number manipulation rules When the gateway receives a call from IP it will first check the CalleelD prefix If the CalleelD prefix is 7 or 8 the gateway will delete it before routing the call to the corresponding SIP trunk group UI Operation Info SIE Ms P Rat s rna ts ss d Check Index Call Initiator CallerlD Prefix CalleelD Prefix With Original CallesID Stripped Digits from Left Stripped Digits from Right Reserved Digits from Right Prefix to Add Suffix to Add Description Modify Route Y t o 63 SIP Trunk Group 0 e 8 No 1 2 t 4 Number Filter 5 o t TT Num Manipulate A IP CallerlD Check Ai Uncheck Ail inverse O Dess Clear All wn E e 2 Items Total 20 Items Page 1 First Previous Next Last Goto Page 1 Pages Total Figure 4 7 SMG SBO Series Gateway User Manual Version 1 6 2 Page 61 lt SSynway Synway Information Engineering Co Ltd Appendix A Technical Specifications Dimensions 440x44x267 mm Weight About 3 1 kg Environment Operating temperature 0 C 45 C Storage temperature 20 C 85 C Humidity 8 90 non condensing Storage humidity 8 90
8. 2 0 2015 08 24 13 49 32 815 201 123 112 33 gt Local SIP ACK sip 114 201 123 112 199 5060 SIPi2 0 stop call track success Figure 3 55 Call Track Interface See Figure 3 55 for the Call Track Interface including three modes Filter CallerlD Filter CalleelD and Filter None This is mainly used to output and save call information facilitating call trace and problem debugging Click Start to track calls and the trace logs will be shown in the Track Message field click Stop to stop the call track click Filter to filter the trace logs according to the condition you set click Clear to clear all trace logs click download to download trace logs SMG SBO Series Gateway User Manual Version 1 6 2 Page 51 Cvnwav Synway Information Engineering Co Ltd 3 7 8 PING Test source IP Address NET 1 201 123 41247 Destination Address 127 DD Ping Count 1 100 Package Lenath 56 1024 bytes aian Figure 3 56 Ping Test Interface See Figure 3 56 for the Ping Test interface A Ping test can be initiated from the gateway on a designated IP address to check the connection status between them The table below explains the configuration items shown in the above figure mem 0 Description Source IP Address Source IP address where the Ping test is initiated Destination Address Destination IP address on which the Ping test is executed Package Length
9. 44 OW Mandon N EE 45 ov ER agen 6 011816 Ee 46 OVE E CODI EE 48 Det COJAN E 49 S70 SIOMANNG Ee 50 Gre ET Te Call TACK E 51 SMG SBO Series Gateway User Manual Version 1 6 2 Pagei ynway Synway Information Engineering Co Ltd e EE o 52 AU er EE EE 53 Keelt e TC COMO RR en evert aeeencane E 54 IT S0 0E EE 55 ar12 FACON PIT TEE P anaes 55 E Me 6 6 2 0 EE 56 314 Change FasSsSWOrd EE 56 SILTS DOVE Eed 57 aI POS A EE E E A EEEE A E E A E E ee ee EO 58 Chapter 4 Typical Applications 59 Appendix A Technical Specifications 62 Appendix B Troubleshooting 63 Appendix C Technical sales Support 64 SMG SBO Series Gateway User Manual Version 1 6 2 Page ii Cvnwav Synway Information Engineering Co Ltd Copyright Declaration All rights reserved no part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical without prior written permission from Synway Information Engineering Co Ltd hereinafter referred to as Synway oynway reserves all rights to modify this document without prior notice Please contact Synway for the latest version of this document before placing an order oynway has made every ef
10. 66 2015 08 13 03 18 05 Add Canfia sMGConfig ini sIP4CALLOLIT siptrunk used1 1 21 fram 201 123 112 68 2015 08 13 09 19 05 Add Canfia SloCanfia ini SIPACALLOLIT siptrunk address1 1 201 123 112 33 from 201 123 112 56 2015 08 13 09 19 05 Add Config sMGConfig ini SIP4CALLOUT siptrunk_portt 1 5065 from 201 123 112 pb wt E II DOE Figure 3 58 Modification Interface The Modification Record interface is used to check the modification record on the web configuration Click Check and the modification record will be shown on the dialog box See Figure 3 58 Click Download to download the record file SMG SBO Series Gateway User Manual Version 1 6 2 Page 54 ynway Synway Information Engineering Co Ltd 3 11 Backup amp Upload To upload a file select it and click the button Upload on the right to start Choose a file to upload Configuration file w RE Note Please editthe CSV file with Notepad Figure 3 59 Backup amp Upload Interface See Figure 3 59 for the Backup and Upload interface To back up data to your PC you shall first choose the file in the pull down list and then click Backup to start To upload a file to the gateway you shall first choose the file type in the pull down list then select it via Browse and at last click Upload The gateway will automatically apply the uploaded data to overwrite the current configurations 3 7 12 Factory Reset Click the button Reset b
11. Mode will this item be shown Sets the rate of delay reduction under the adaptive mode It defines the maximum percentage of the silence that can be removed in delay reduction Range of value 0 100 with the default value of 50 Note Only when JitterMode is set to Adaptive Mode will this item be shown JitterDecreaseRatio Sets the maximum delay increased during a silence period Range of value 0 280 JitterincreaseMax calculated by ms with the default value of 30 Note Only when JitterMode is set to Adaptive Mode will this item be shown Adjusts the voice gain of call from IP to IP The value must be a multiple of 3 Range from IP of value 24 24 calculated by dB with the default value of 0 Sets CODECs for the IP end to establish a call conversation The table below explains the sub items Sub item Description SMG SBO Series Gateway User Manual Version 1 6 2 Page 29 ynway Synway Information Engineering Co Ltd Priority for choosing the CODEC in an SIP conversation The Priorit d smaller the value is the higher the priority will be Seven optional CODECs are supported G711A G711U G729 G723 G722 AMR and iLBC TNT The number of thousand bits excluding the packet header that 8feconveyedpersecond By default all of the seven CODEOs are supported and ordered G711A G711U G729 G723 G722 AMR and iLBC by priority from high to low The CODECs set here will be the d
12. Prefix Calleeld Prefix Call Destination SIF Trunk Group 0 w Number Filter Description default Figure 3 25 Add New Routing Rule IP gt IP The table below explains the items shown in the above figure The unique index of each routing rule which denotes its priority A routing rule with a smaller index value has a higher priority If a call matches several routing rules it will be processed according to the one with the highest priority SIP trunk group from where the call is initiated This item can be set to a specific Call Initiator C SIP trunk group or SIP Trunk Group ANY which indicates any SIP trunk group A string of numbers at the beginning of the calling called party number This item KII can be set to a specific string or which indicates any string These two CallerlD Prefix configuration items together with Call Initiator can specify the calls which apply to a CalleelD Prefix routing rule Note Multiple rules are supported for CallerlD CalleelD prefix They are separated by Call Destination Number filter rule which will be applicable to this route It is set in Number Filter Number Filter See 3 5 4 Filtering Rule for details Description More information about each routing rule SMG SBO Series Gateway User Manual Version 1 6 2 Page 31 ynway Synway Information Engineering Co Ltd After configuration click Save to save the settings into the gateway or click Close to cancel t
13. The default setting is Enable Sets the working mode of JitterBuffer The optional values are Static Mode and JitterMode Adaptive Mode with the default value of Static Mode Acceptable jitter for data packets transmission over IP which indicates the buffering capacity A larger JitterBuffer means a higher jitter processing capability but as well JitterBuffer as an increased voice delay while a smaller JitterBuffer means a lower jitter processing capability but as well as a decreased voice delay Range of value 0 280 calculated by ms with the default value of 100 Sets the initial delay applied to received packets upon accepting packets later than the expected value set in JitterBuffer Item Range of value 0 280 calculated by JitterUnderrunLead ms with the default value of 100 Note Only when JitterMode is set to Static Mode will this item be shown Sets the beforehand time inserted if receiving packets is ahead of time the time of receiving is earlier than 300 minus the value set in JitterBuffer Rnage of value JitterOverrunLead 0 280 calculated by ms with the default value of 50 Note Only when JitterMode is set to Static Mode will this item be shown Sets the minimum delay that can be set by the adaptive jitter function It must be smaller than the value set in JitterBuffer Range of value 0 280 calculated by ms JitterMin with the default value of 80 Note Only when JitterMode is set to Adaptive
14. Yes ONo NTP Server Address 4270 0 4 aynchronizing Cycle 3600 Daily Restart Yes Ono Restart Time 7 B h 13 Ri m system Time al Modify Time Zone GMT 8 00 Beijing Sing apore Taipei Kual ze A Figure 3 48 Management Parameters Setting Interface See Figure 3 48 for the Management Parameters Setting interface The table below explains the items shown in the above figure em Demo o WEB Port The port which is used to access the gateway via WEB The default value is 80 Sets the IP addresses which can access the gateway via WEB By default all IPs are allowed You can set an IP whitelist to allow all IPs within it to access the Access Setting gateway freely Also can set an IP blacklist to forbid all IPs within it to access the gateway SMG SBO Series Gateway User Manual Version 1 6 2 Page 45 ynway Synway Information Engineering Co Ltd Sets whether to enable the gateway to be accessed via SSH with the default value of No H p SSH Port Capture tool with the default value of No and SYSLOG Level in case SYSLOG is enabled By default SYSLOG is disabled Sets whether to enable the NTP time synchronization feature It is required to fill in NT NTP Server Address Synchronizing Cycle and Time Zone in case NTP is enabled By default NTP is disabled NTP Server Address Sets the Server address for NTP time synchronization Synchronizing Cycle Sets the
15. about login refer to 3 1 System Login We suggest you change the initial username and password via System Tools Change Password on the WEB interface as soon as possible after your first login For detailed instructions about changing the password refer to 3 7 14 Change Password After changing the password you are required to log in again Step 6 Modify IP address of the gateway You can modify the IP address of the gateway via System Tools gt Network on the WEB interface to put it within your company s NET Refer to 3 7 1 Network for detailed instructions about IP modification After changing the IP address you shall log in the gateway again using your new IP address Step 7 Check the channel status You can check the status of the channels via Operation Info gt IP Status Refer to 3 2 2 IP Status for detailed introductions Step 8 Set routing rules for calls Note For your easy understanding and manipulation all examples given in this step do not involve registration otep 1 Configure the IP address of the remote SIP terminal which can establish conversations with the gateway so that the calls from other terminals will be ignored Refer to SIP Settings gt SIP Trunk for detailed instructions Click Add New to add a new SIP trunk SMG SBO Series Gateway User Manual Version 1 6 2 Page 5 ynway Synway Information Engineering Co Ltd otep 2 Step 3 Step 4 fill in Remote IP and
16. and input your password to unlock the device This device has been locked successfully Figure 3 65 Device Lock Interface SMG SBO Series Gateway User Manual Version 1 6 2 Page 57 ynway Synway Information Engineering Co Ltd 3 16 Restart Click the button Restart to restart the service Click the button Restart to restart the system Figure 3 66 Service System Restart Interface See Figure 3 66 for the Restart interface Click Restart on the service restart interface to restart the gateway service or click Restart on the system restart interface to restart the whole gateway system SMG SBO Series Gateway User Manual Version 1 6 2 Page 58 Cvnway Synway Information Engineering Co Ltd 1 Chapter 4 Typical Applications Internet IMS Server IP Phone IP Phone LAN Figure 4 1 Application 1 Configure SIP Settings SMG SBO Series Gateway User Manual Version 1 6 2 Page 59 Synway Ui Operation Info x SIP a SIP SIP Address of WAN See Auto Change Default Gateway SIP Register SIP Account SIP Signaling Port SIP Trunk Group Media Obtain CalleriD from a Route Y Obtain CalleelD from feel Number Filter NAT Traversal f Num Manipulate SIP Transport Protocol FRR System Tools Y SIP Encryption RTP Encryption RTP Self adaption UDP Header Checksum Rport DSCP Calls from SIP Trunk Address only Switch Signal Port if SIP Registration Failed Working Per
17. at most on the corresponding network interface SIP and SysLog are supported at present You can input a destination address for syslog to which the syslog file will be sent Click Stop to stop data capture and download the captured packets IP Two way Recording is used to make recording of a designated channel in a specified channel group Click Start to start recording data maximum consecutively recording time 1 minute Click Stop to stop data recording and download the recorded data Click Clean Data to clean all the recording files and captured packages Click Download Log to download such logs as core files configuration files error information and so on SMG SBO Series Gateway User Manual Version 1 6 2 Page 50 Cvnwav Synway Information Engineering Co Ltd 3 7 7 Signaling Call Track Filter CallerlD 9 Filter CalleelD Filter None Track Message IP 08 24 2015 13 49 32 784 ch 0002 bind 0003 GWS IM WAIT OUT COMMECT GWS IM SEND PICKLIP 08 24 2015 13 49 32 784 ch 0003 bind 0002 GG OUT WAIT COMMECT GWS OUT COMMECTED 08 24 2015 13 49 32 785 ch 0002 bind 0003 GWS_IN_SEND_PICKUP GWS IM COMMECTED 08 24 2015 13 49 32 785 ch 0002 bind 0003 GWS IM GEND PICKLIP GWS IN CONMECTED 2015 08 24 13 49 32 793 Local 201 123 112 33 SIP SIP 2 0 200 OK 2015 08 24 13 49 32 793 Local 201 123 112 33 SIP SIP 2 0 200 OK 2015 08 24 13 49 32 815 201 123 112 33 gt Local SIP ACK sip 114 201 123 112 199 5060 SIP
18. before the corresponding index in Figure 3 17 and click the Delete button Check All means to select all available items on the current page Uncheck All means to cancel all selections on the current page Inverse means to uncheck the selected items and check the unselected To clear all SIP accounts at a time click the Clear All button in Figure 3 17 3 3 5 SIP Trunk Group By default there is no SIP trunk group available on the gateway Click Add New to add them manually See Figure 3 19 SMG SBO Series Gateway User Manual Version 1 6 2 Page 25 ynway Synway Information Engineering Co Ltd Index Description SIP Trunk Select Made SP Trunks Clo Figure 3 19 Add New SIP Trunk Group The table below explains the items shown in Figure 3 19 em Desorption o The unique index of each SIP trunk group which is mainly used in the configuration of routing rules and number manipulation rules to correspond to SIP trunk groups When the SIP trunk group receives a call it will choose a SIP trunk based on the select mode set by this configuration item to ring The optional values and their corresponding meanings are described inthe table below __ Option 0escrption V Search for an idle SIP trunk in the ascending order of the Increase SIP trunk number starting from the minimum __ SIP Trunk Select 5 Search for an idle SIP trunk in the descending order of e
19. lar Channel Gru Ea Channel Group2 ccc alking E caaocccccczccccc channel Groups SSSGeCCCCCCR0 Channel Groun EE Channel Group SSSGG00000066 Channel Groups SSSG0CCCCCC00 Channel Grup c2222202222090 Channel Group SSG00CC000065 Channel Groups SSGG0000C6E00 Channel Group SSSSG00000066 Channel Grup SSSG000CC6E00 Channel Group c222222222925 channel Group13 EECH channel Group EECH Channel Group s SSG0CCCS00050 channel Group 2222222222227 Channel Group SSGCCCCCCC0CR Channel Groupie Ss Channel Groupte czcoczcccczccc Channel Group20 SSGCCCG00008 Channel Group SSGCCCG00058 Channel Grupz2 Sg BEE SSGCCCCS00000 Channel Group SSGeoCCSG0058 Channel Group2s Sg BEE Ss Channel Group gogogpogogoggoggg Channel Group28 c2zzcccoczczcccccc Channel Groupzo Ss Channel Groupao Sagan Channel Group31 Sg Channel Group32 c Qaczccczccc Note If the icons display abnormally please clear the cache and refresh this page Figure 3 5 IP Status Interface See Figure 3 5 for the IP status interface which shows the real time status of each IP channel on the gateway Displays the channel state in real time You can move the mouse onto the channel state icon for detailed information about the channel and the call such as call direction calling party number and called party number The channel states include SMG SBO Series Gateway User Manual Version 1 6 2 Page 10 ynway Synway Information Engineering Co Ltd Idle WW The channel
20. lt Synway Synway SBO Series Gateway SBO500 Gateway User Manual Version 1 6 2 Synway Information Engineering Co Ltd WWW Synway net ynway Synway Information Engineering Co Ltd Content COMENT eee i COPY AON DECI AU OU DEE iii REVISION FRIST ORY GE iv Chapter 1 Product Introduction 1 decd J ee e ee EE 1 12 PS AU E 2 1 3 Hardware Description cccccccceeeeseeeceeeeeeeeneeeseeeceueeaeeseeeseeeseeeseueeneeeseeesags 2 Vee PANY WO EE 4 uris LU Cor OUG arinn 5 Chapter 3 WEB Configuration eere eee 7 Sy Me En H e ell EE 7 EECH Mee 8 3 2 1 Seege 8 PL MEN RR m 10 04 2080607407777 12 STE erit ge E 13 3 3 1 SIO E 14 eC T Geren EE EE 17 CN ec I EE 20 CNC MEME SI ee Game nee nO ee ee ene ee ee ee ee ee ee ee E 23 J3 MEE I GO EE 25 9 9 0 Media SelliNgS erret ritiene oae tarn thea ese eaae su Xs ead sae ser EN AEs 28 Sr M e Ett dn Le TREO 30 3 4 1 Routing M sz lez itis E RTT 30 I MEI e 31 9S0 NUMO FIO TOT OUR 32 3 5 1 dU m E 33 oy a 2 01 ee 35 299 NUMO POON ee 36 SOR FON O RT 37 SO RRE del 40 JOT 2017 54929 ERR 40 V c I0 20 7 a ene ee 42 I S SECU VOCS RR RR 43 3 7 1 PV OF ege
21. the SIP trunks into the corresponding SIP trunk groups il Operation Info EE Check Index SIP Trunks SIP Trunk Select Mode Description Modify SIP F 0 0 increase default L SIP Trunk t i SIP Register EJ 1 1 Increase default L SIP Account EJ 2 2 Increase default L SIP Trunk Group i i j a Media Check All UncheckAll inverse EPEE cl gt k AddNeW 3 Items Total 20 Items Page 1 1 First Previous Next Last GotoPage 1 1Pages Total al Route Y Figure 4 4 d Set routing parameters You may adopt the default value Route before Number Manipulate for both configuration items SMG SBO Series Gateway User Manual Version 1 6 2 Page 60 ynway Synway Information Engineering Co Ltd DI Operation Info x SIP Y aJ Route Route before Number Manipulate Routing Parameters IP gt IP Ee Number Filter Y Figure 4 5 5 Set IPS IP routing rules to route calls from different SIP trunk groups to the corresponding SIP trunk groups UU Operation Info x SIP B Check Index Call Initiator CallerlD Prefix CalleelD Prefix Number Filter Call Destination Description Modify Route T Y 1 4 63 SIP Trunk Group 0 none SIP Trunk Group 1 default L Routing Parameters T i f i IP gt IP aa le k bebe O a SIP
22. Call Destination Keep the default values for the other configuration items Initiate a call from the SIP trunk O configured in Step 1 to the IP address and port of the SBO gateway Thus you can establish a call conversation via SIP trunk 1 with the IP terminal Note The format used for calling an IP address via SIP trunk is as follows username IP address Example Provided the IP address of the SBO gateway is 192 168 0 101 and the port is 5060 Provided 123 is a number which conforms to the number receiving rule of the remote device Initiate a call from SIP trunk O to the IP address 192 168 0 101 in the format 123 192 168 0 101 and you can establish a call conversation via SIP trunk 1 to the number 123 Special Instructions The chassis of the SBO gateway must be grounded for safety reasons according to standard industry requirements A simple way is earthing with the third pin on the plug or the grounding studs on the machine No or improper grounding may cause instability in operation as well as decrease in lightning resistance As the device will gradually heat up while being used please maintain good ventilation to prevent sudden failure ensuring that the ventilation holes see Figure 1 4 are never jammed During runtime if the alarm indicator lights up or flashes it indicates that the device goes abnormal If you cannot figure out and solve the problem by yourself please contact our technicians for help Otherwise it
23. GGcmsaazcccasccosacazzcoscccocaazcccccco cw asGGGGSZZZcos22z2zcccoocascacccccccascco ow Gaccoccccococcccooccccocoocccococczccc wc QOGGOSSSSSSGSSSSSG00CC0000000008 cw asGGGCSZEZZcOoO22Z2ccoccazcccccccccco cc GGaZCCCcZCcOOZZ2zcozccoccazcccoccco cw am gGGGESZZZzcoszazazcccocascacccccccccco c Gacasxccccasccoscazczcocccccacacccoccco ww QJ QOSROSSSSSSSSSSSG00CC5000000008 cc OO ORGAO SSSHSSSSSSSSSSSCCCSG00008 ww QQGGOOSSSSSGSSSSSG00CCS000000008 ww QO OGROGSSSOSSSSSGG00CC5000000008 channel cours SSSSCCCSG0C50000050068 cw QOOGROGSSSSGSSSSGG00C55000000008 cc OO OGGHHGOSSHSSSSSSSSSSSSSSSSG000R cw QOS SOSOSSSSGSCSSG000CC5000000608 cc OO OGHGHOSSSHSSSSSSSSSSGCCCCG00008 cw QOS OSSSSSSGGSSSSG00CC0000000008 wc QO OSGHSSSSSSSSSSSSSSGGCCCSC00008 Note Ifthe icons display abnormally please clear the cache and refresh this page Figure 3 6 Search Calls 3 2 3 Call Count Release Reason Normalcallclearing Cancelled by calling party Userbusy No answer from user Routefailed Resource unavailable Callfailed Others Number RI EE RSC KC EECH Sio s Percentage 100 0096 0 0096 0 0096 0 0096 0 0096 0 0096 0 0096 0 0096 Figure 3 7 Call Count Interface See Figure 3 7 for the call count Interface The above list shows the detailed information about all the calls counted from the startup of the gateway service to the latest open or refresh of this SMG SBO Series Gateway User Manual Version 1 6 2 Page 12 ynway Synway Inf
24. IP Register Expires account should be registered again Range of value 10 3600 calculated by s with the default value of 3600 Authentication username of a port used to register the port to the SIP server when Authentication IMS network is enabled Username Note This item appears only when IMS Network is enabled on the SIP trunk corresponding to this SIP account More information about each SIP account After configuration click Save to save the settings into the gateway or click Close to cancel the settings See Figure 3 17 for the SIP Account Settings Interface SMG SBO Series Gateway User Manual Version 1 6 2 Page 24 ynway Synway Information Engineering Co Ltd Checl Index SIP Trunk No Username Authentication Username Register Expires s Register Status Description Modify 0 0 111 3600 Failed deault Check All Uncheck All Inverse Clear All Add New 1 Items Total 20 Items Page 1 1 First Previous Next Last Goto Page 1 E 1 Pages Total Figure 3 17 SIP Account Settings Interface Click Modify in Figure 3 17 to modify a SIP account See Figure 3 18 for the SIP account modification interface The configuration items on this interface are the same as those on the Add New SIP Account interface SIP Account Index E Username 111 Password Register Expires s Authentication Username Description deault Figure 3 18 Modify SIP Account To delete a SIP account check the checkbox
25. Length of a data package used in the Ping test Range of value 56 1024 bytes int The information returned during the Ping test helping you to learn the network nfo connection status between the gateway and the destination address After configuration click Start to execute the Ping test click End to terminate it immediately Ping Count The number of times that the Ping test should be executed Range of value 1 100 SMG SBO Series Gateway User Manual Version 1 6 2 Page 52 Cvnwav Synway Information Engineering Co Ltd 3 7 9 TRACERT Test source IP Address NET 1 201 123 112 17 Destination Address 127 0 0 1 Maximum Jumps 1 255 30 a le Figure 3 57 Tracert Test Interface See Figure 3 57 for the Tracert Test interface A Tracert test can be initiated from the gateway on a designated IP address to check the routing status between them The table below explains the configuration items shown in the above figure mem Besrpio Source IP Address Source IP address where the Tracert test is initiated Destination Address Destination IP address on which the Tracert test is executed Maximum number of jumps between the gateway and the destination address Maximum Jumps l which can be returned in the Tracert test Range of value 1 255 int The information returned during the Tracert test helping you to learn the detailed nfo information about the jumps between the gateway and the destination addr
26. Page 4 ynway Synway Information Engineering Co Ltd Chapter 2 Quick Guide This chapter is intended to help you grasp the basic operations of the SBO gateway in the shortest time Step 1 Confirm that your packing box contains all the following things SBO Series Gateway 1 Angle Bracket 2 Rubber Foot Pad 4 Screw for Angle Bracket 8 220V Power Cord 2 Warranty Card 1 Installation Manual 1 Step 2 Properly fix the SBO gateway If you do not need to place the gateway on the rack simply fix the 4 rubber foot pads Otherwise you should first fix the 2 angle brackets onto the chassis and then place the chassis on the rack Step 3 Connect the power cord Make sure the device is well grounded before you connect the power cord Check if the power Socket has the ground wire If it doesn t use the grounding stud on the rear panel of the device See Figure 1 3 for earthing Note Each SBO gateway has two power interfaces to meet the requirement for power supply hot backup As long as you properly connect and turn on these two power keys either power supply can guarantee the normal operation of the gateway even if the other fails Step 4 Connect the network cable Step 5 Log in the gateway Enter the original IP address NET 1 192 168 1 101 or NET 2 192 168 0 101 of the SBO gateway in the browser to go to the WEB interface The original username and password of the gateway are both admin For detailed instructions
27. Register Expires s IMS Network Externally Bound Address Externally Bound Part Authentication Username Se Close Figure 3 13 Add SIP Register Interface The table below explains the items shown in the above figure mem Desepten 0 The unique index of each SIP register SIP Trunk No The number of the SIP trunk which registers to the SIP server When the gateway initiates a call to SIP this item corresponds to the username of Username SIP when the gateway initiates a call to IP this item corresponds to the displayed CallerID Register Address Address of the SIP server to which the SIP trunk is registered Register Port The signaling port of the SIP trunk Domain name of the gateway used for SIP registry p Registration password of the gateway To register the gateway to the SIP server asswor both configuration items Username and Password should be filled in SMG SBO Series Gateway User Manual Version 1 6 2 Page 21 ynway Synway Information Engineering Co Ltd Validity period of the SIP registry Once the registry is overdue the gateway should Register Expires be registered again Range of value 10 3600 calculated by s with the default value of 3600 Once this feature is enabled the gateway will send signaling messages to the corresponding externally bound address and port when it registers to the server IMS Network Only when this feature is enabled will these items Externall
28. Remote Port with the IP address and port of the remote SIP terminal which will initiate calls to the gateway You may use the default values for the other configuration items Example Provided the incoming IP address of the SIP trunk is 192 168 0 111 and the port is 5060 Add SIP Trunk 0 set Remote IP to 192 168 0 111 and Remote Port to 5060 The outgoing IP address of the SIP trunk is 192 168 0 222 and the port is 5060 Add SIP Trunk 1 set Remote IP to 192 168 0 222 and Remote Port to 5060 Add the IP address of the SIP trunks configured in Step 1 into the corresponding SIP trunk group Refer to SIP Settings gt SIP Trunk Group for detailed instructions Click Add New to add the SIP trunk group Select the SIP trunk configured in Step 1 as SIP Trunks You may use the default values for the other configuration items Example Add SIP Trunk Group 0 Check the checkbox before 0 for SIP Trunks and keep the default values for the other configuration items Add SIP Trunk Group 1 Check the checkbox before 1 for SIP Trunks and keep the default values for the other configuration items Add routing rules Refer to Route Settings IP IP for detailed instructions Select the SIP trunk group O set in Step 2 as Call Initiator and the SIP trunk group 1 set in Step 2 as Call Destination You may use the default values for the other configuration items Example Select SIP Trunk Group 0 as Call Initiator and SIP Trunk Group 1 as
29. anipulation rule which denotes its priority A number manipulation rule with a smaller index value has a higher priority If a call matches several number manipulation rules it will be processed according to the one with the highest priority SIP trunk group from where the call is initiated This item can be set to a specific Call Initiator PW SIP trunk group or SIP Trunk Group ANY which indicates any SIP trunk group A string of numbers at the beginning of the calling called party number This item Tt 2H CallerlD Prefix can be set to a specific string or which indicates any string These two CalleelD Prefix configuration items together with Call Initiator and With Original CalleelD can specify the calls which apply to a number manipulation rule If this item is set to Yes it indicates that the number manipulation rule is only With Original applicable to the calls with original CalleelD redirecting number The default value is CalleeID No o The amount of digits to be deleted from the left end of the number If the value of Stripped Digits from PA this item exceeds the length of the current number the whole number will be e deleted ae The amount of digits to be deleted from the right end of the number If the value of Stripped Digits from m BIS this item exceeds the length of the current number the whole number will be Ig deleted The amount of digits to be reserved from the right end of the number Only
30. ce See Figure 3 4 for the system info interface You can click Refresh to obtain the latest system information The table below explains the items shown in Figure 3 4 wem Deegptes ooo SMG SBO Series Gateway User Manual Version 1 6 2 Page 8 ynway Synway Information Engineering Co Ltd MAC Address MAC address of NET 1 or NET 2 The three parameters from left to right are IP address subnet mask and default IP Address gateway of NET 1 or NET 2 DNS Server DNS server address of NET 1 or NET 2 Receive Packets The amount of receive transmit packets after the gateway s startup including three Transmit Packets categories All Error and Drop Current Speed The current speed of data receiving and transmitting The work mode of the network including five options 10 Mbps Half Duplex 10 Work Mode Mbps Full Duplex 100 Mbps Half Duplex 100 Mbps Full Duplex and 1000 Mbps Full Duplex Time of the gateway keeping running normally after startup This parameter updates every 2s Serial Number Unique serial number of a SBO gateway Current version of the WEB interface Current version of the gateway service Current version of Uboot Current version of the system kernel on the gateway Current version of the firmware on the gateway SMG SBO Series Gateway User Manual Version 1 6 2 Page 9 ynway Synway Information Engineering Co Ltd 3 2 2 IP Status CST SN EC EIE EE IER EC a fet aleas awan
31. ce trunk to the gateway SMG SBO Series Gateway User Manual Version 1 6 2 Page 18 SIP transport protocol providing two modes UDP and TCP The default value is Transport Protocol JOP ynway Synway Information Engineering Co Ltd Incoming Voice Maximum number of voice channels for the incoming calls allocated by the SIP Resource trunk to the gateway The work period for the gateway You can specify a certain period for the gateway to Working Period mE make calls By default the gateway is allowed to make calls any time in the day 24 Period Hours Supported CODECs and their corresponding priorities for the SIP trunk to establish a call conversation The table below explains the sub items Sub item Description Priority for choosing the CODEC in an SIP conversation The smaller the value is the higher the priority will be E Seven optional CODECs are supported G711A G711U G729 G722 G723 AMR and iLBC __ CODEC Priority See 3 3 6 Media Settings for the detailed parameters for each CODEC The default CODEC for the SIP trunk is the same as that set in 3 3 6 Media Settings After configuration click Save to save the settings into the gateway or click Close to cancel the settings See Figure 3 11 for the SIP Trunk Settings Interface 2mnlmimimpinm Check All Uncheck All Inverse Clear All Add New 5 items Total 20 ttems Page 1 1 First Previous Next Last Goto Page 1 v 1 Pages Total Figure 3 11 SIP Tr
32. cludes four parts Whitelist Blacklist Number Pool and Filtering Rule See Figure 3 28 SMG SBO Series Gateway User Manual Version 1 6 2 Page 32 e gt ynway Synway Information Engineering Co Ltd be Number Filter A Whitelist Blacklist Number Pool Filtering Rule Figure 3 28 Number Filter Interface 3 5 1 Whitelist Check Group No No in Group CalleriD Modify Check Group No No in Group CalleelD Modify O 0 0 100 FJ 0 0 101 Clear All Add New Clear All Add New Note You shall restart the service to validate the settings on this page Figure 3 29 Whitelist Setting Interface See Figure 3 29 for the Whitelist Setting Interface which includes two parts CallerlD Whitelist and CalleelD Whitelist A new CallerID CalleelD whitelist can be added by the Add New button See Figure 3 30 Figure 3 31 for CallerlD CalleelD whitelist adding interface CalleriDs in Whitelist Group No No in Group CallerlD Figure 3 30 Add New CallerIDs in Whitelist Interface SMG SBO Series Gateway User Manual Version 1 6 2 Page 33 Cvnway Synway Information Engineering Co Ltd CalleelDs in Whitelist Group No in Group CalleelD Figure 3 31 Add New CalleelDs in Whitelist Interface The table below explains the items shown in above figures o mem 0 Description T The corresponding Group ID for CallerlDs CalleelDs in the whitelist The value rou i range is 077 The corresponding No for differen
33. crease Mode the SIP trunk number starting from the maximum Provided SIP Trunk N is the available SIP trunk found last time Search for an idle SIP trunk in the ascending order of the SIP trunk number starting from SIP Trunk N 1 Provided SIP Trunk N is the available SIP trunk found last 3 time Search for an idle SIP trunk in the descending order 3 of the SIP trunk number starting from SIP Trunk N 1 The SIP trunks in the SIP trunk group If the checkbox before a SIP trunk is grey it SIP Trunks indicates that the SIP trunk has been occupied The ticked SIP trunks herein will be displayed in the column SIP Trunks in Figure 3 20 After configuration click Save to save the settings into the gateway or click Cancel to cancel the settings See Figure 3 20 for the SIP Trunk Group Setting Interface SMG SBO Series Gateway User Manual Version 1 6 2 Page 26 ynway Synway Information Engineering Co Ltd Check Index SIP Trunks SIP Trunk Select Mode Description Modify F 0 0 Increase default P E 1 1 Increase default e F 2 2 Increase default P O Increase default Pi CheckAll Uncheckall Imere iin Clear All 4 tems Total 20ltems Page 1 1 First Previous Next Last Goto Page 1 Figure 3 20 SIP Trunk Group Settings Interface Click Modify in Figure 3 20 to modify a SIP trunk group See Figure 3 21 for the SIP trunk group modification interface The configuration items o
34. cycle for NTP time synchronization Sets whether to restart the gateway regularly every day at the preset Restart Time Daily Restart m By default this feature is disabled Restart Time Sets the time to restart the gateway regularly The system time Check the checkbox before Modify and change the time in the System Time n edit box Time Zone The time zone of the gateway 3 7 3 IP Routing Table IP Routing Table is used to set the route for the LAN port when these two network ports both transport SIP Thus the LAN can access some IPs in other different network segment By default there is no routing table available on the gateway click Add New to add them manually See Figure 3 49 Routing Table No Destination Subnet Mask Network Port MET 1 w Figure 3 49 Routing Table Adding Interface The table below explains the items shown in above figures em Description O OOO O SMG SBO Series Gateway User Manual Version 1 6 2 Page 46 ynway Synway Information Engineering Co Ltd Na The number of the routing for the LAN in routing table Destination The network segment in which the IP address is accessible for the network port Subnet Mask The subnet mask of the network segment Network Port The corresponding network port of the routing After configuration click Save to save the settings into the gateway or click Close to cancel the settings See Figure 3 50 for the Routing Table List
35. ed to set the basic and register information of the SIP trunk SIP Register is used for the registration of SIP SIP Account is used for registering SIP accounts to the SIP server SIP Trunk Group is to manage SIP trunks by group and Media is to set the RTP port and the payload type SIP A SIP SIP Trunk SIP Register SIP Account SIP Trunk Group Media Figure 3 8 SIP Settings SMG SBO Series Gateway User Manual Version 1 6 2 Page 13 Cvnwav Synway Information Engineering Co Ltd 3 3 1 SIP Settings SMG SBO Series Gateway User Manual Version 1 6 2 Page 14 Synway Synway Information Engineering Co Ltd SIP Address of WAN Auto Change Default Gateway SIP Signaling Port Obtain CallerlD from Obtain CalleelD from MAT Traversal Traversal Tvpe LAM1 Mapping Address LAN Mapping Address SIP Transport Protocol SIP Encryption Encrpytion Criterion Key RTP Encryption RIP Self adaption UDF Header Checksum Rport DSCP Vaice Media signal Control Calls fram SIP Trunk Address only Switch Signal Port if SIP Registration Failed Working Periad Periodihh mm ss Maximum VWait Answer Time 5 Maximum Wait RTF Time 5s SMG SBO Series Gateway User Manual Version 1 6 2 LAN 1 201 123 112 17 Ll Enable 5060 g s Username af From Field vt Request Field v Enable Port Mapping L UDP y Enable VOSTA m Enable Enable Enab
36. efault CODEC for the new added SIP trunks The packing time and bit rate supported by different CODECs are listed in the table below Those values in bold face are the default values amp _ COEDC Packing Time ms Bit Rate kbps G711A 5 10 20 30 40 50 60 64 G711U 5 10 20 30 40 50 60 D 6729 29 G723 30 60 90 5 10 20 30 40 4 75 5 15 5 90 6 70 7 40 7 95 10 20 12 20 3 4 Route Settings Route Settings is used to specify the routing rules for calls from IP IP See Figure 3 23 Li Route A Routing Parameters IP IP Figure 3 23 Route Settings 3 4 1 Routing Parameters IP Call In Figure 3 24 Routing Parameters Configuration Interface See Figure 3 24 for the routing parameters configuration interface On this interface you can set the routing rules for calls from IPIP to be routing before or after number manipulation The default value is Route before Number Manipulate SMG SBO Series Gateway User Manual Version 1 6 2 Page 30 ynway Synway Information Engineering Co Ltd After configuration click Save to save the above settings into the gateway 3 4 2 IP to IP By default there is no IPIP routing rule available on the gateway Click Add New to add them manually See Figure 3 25 for the IPIP routing rule adding interface IP 1P Routing Rule Index 53 Call Initiator SIP Trunk Group 0 k Callerld
37. el 86 571 88864579 Mobile 86 1890581 7070 Email techsupport sanhuid com Email techsupport synway net MSN synway support hotmail com Sales Department Tel 86 571 88860561 Tel 86 571 88864579 Fax 86 571 88850923 Email sales synway net SMG SBO Series Gateway User Manual Version 1 6 2 Page 64
38. elow to restore to factory settings Figure 3 60 Factory Reset Interface See Figure 3 60 for the Factory Reset interface Click Reset to restore all configurations on the gateway to factory settings SMG SBO Series Gateway User Manual Version 1 6 2 Page 55 Cvnwav Synway Information Engineering Co Ltd 3 7 13 Upgrade Current Version Serial Number WEB 1 5 2 2015082418 Service 1 5 2 2015082418 Uboot 2 0 9 201505 Kernel 351 SMP Wed Aug 5 10 15 28 CST 2015 Firmware 16 000001861 Selectan Update Fie ss Browse Figure 3 61 Upgrade Interface See Figure 3 61 for the upgrade interface where you can upgrade the WEB gateway service kernel and firmware to new versions Select the upgrade package tar gz via Browse and click Update The gateway will do MD5 verification before upgrading and will not start to upgrade until it passes the verification Wait for a while and the gateway will finish the upgrade automatically Note that clicking Reset can only delete the selected update file but not cancel the operation of Update 3 7 14 Change Password Current Username admin Current Password New Username New Password Confirm New password Note The username and the password can consist only of numbers letters or the underline Figure 3 62 Password Changing Interface See Figure 3 62 for the Password Changing interface where you can change username and password of the gateway Enter the current pas
39. erver Receive Packets All 0 Error 0 Drop 0 Transmit Packets EUR Error Drop 0 Current Speed Receive 0 B s Transmit0 B s Work Mode Unknown Unknown Runtime 3h 40m 37s Current Version Serial Number 000001861 WEB 1 6 2 2015082016 Gateway 1 6 2 2015082016 Uboot Kernel 351 SMP Wed Aug 5 10 15 28 CST 2015 Firmware 16 Figure 3 2 Main Interface SMG SBO Series Gateway User Manual Version 1 6 2 Page 7 ynway Synway Information Engineering Co Ltd 3 2 Operation Info Operation Info includes three parts System Info IP Status and Call Count showing the current running status of the gateway See Figure 3 3 II Operation Info A System Info IP Status Call Count Figure 3 3 Operation Info 3 2 1 System Info LAM 1 WAC Address 80 7B 85 10 04 92 IP Address 201 123 112 177 255 255 255 200 123 112 254 DNS Server 0 0 0 0 Receive Packets Al 176962 Drop 0 Transmit Packets Al595 Error Drop Current Speed Receive 1 3 KB s Transmit638 Die Work Mode 1 0 0Mb s Full Duplex LAN 2 MAC Address 80 7B 85 10 04 93 IP Address 182 168 0 101 bb 255 255 192 168 0 254 DNS Server 0 0 0 0 Receive Packets AIF Error Drop Transmit Packets GU Errar Drop Current Speed Receive His Transmit Bis Work Made Unknown Unknown Runtime 3h 40m 37s Current Version serial Number 000001861 WEB 1 5 2 2015082018 Gateway 1 6 2 2015082018 Uboot 20 9 201505 Kernel 351 SMP Wed Aug 5 10 Firmware 16 Figure 3 4 System Info Interfa
40. ess After configuration click Start to execute the Tracert test click End to terminate it immediately SMG SBO Series Gateway User Manual Version 1 6 2 Page 53 Cvnway Synway Information Engineering Co Ltd 3 7 10 Modification Record 2015 08 12 11 17 16 Mad Confia sSMaGConfia ini HetCanfig Gateway1 182 188 1 254 2201 123 112 254 from 201 123 112 66 2015 08 12 11 17 16 Mod Config SMGConfid ini NetContig CheckNett 0 0 from 201 123 112 656 SC 2015 08 12 11 17 16 amp dd Confia sMaconfia ini HetCanfia Made 1 1 20 from 201 123 112 66 2015 08 12 11 17 15 Mad CanfiasMGCanfia ini HetCanfia CheckMetz 0 from 201 123 112 656 2015 08 12 11 17 18 amp dd CanfiasMaGconfia ini HetCanfia Tade2 1 0 fram 201 123 112 565 2015 08 12 11 17 16 Mad Confia s MGConfia ini GV GLOBAL alobal localaddress 192 168 1 101 201 123 112 61 from 201 123 112 56 2015 08 12 11 17 16 Mad Config sShConfig ini SIP Lacalsiplp 1982 168 1 101 2201 123 112 61 from 201 123 112 66 2015 08 12 11 17 15 Mad Config sShConfig ini Boardld BoardIP 192 158 1 101 2201 123 112 61 from 201 123 112 65 2015 08 12 11 17 16 Mad Confia sShcanfig ini Baardldz Gateway 192 168 1 254 201 123 112 254 from 201 123 112 56 2015 08 12 13 28 28 Add Confia sSMaCconfia ini Syslnfa Langquage 1 0 from 201 123 112 68 2015 08 13 08 18 58 Add Canfig sllGoCanfia ini SIPAC AL LOLIT sip callaut trunk max 1 21 from 201 123 112 668 2015 08 13 08 18 58 Add Can
41. eway and DNS server The Bond feature when enabled will make the information of LAN1 and LAN2 duplicated and backed up so as to realize the hot backup function for LAN1 and LAN2 By default this feature is disabled Note 1 The two configuration items IP Address and Default Gateway cannot be the same for NET 1 and NET 2 2 By default Speed and Duplex Mode is hidden set to Automatic Detection You can click F to let it display We suggest you do not modify it because the non automatic detection may cause abnormity in network interface If the Network Detect feature is enabled a ping test will automatically be initiated from this IP address to the gateway to check the connection status between them By default this feature is SMG SBO Series Gateway User Manual Version 1 6 2 Page 44 ynway Synway Information Engineering Co Ltd disabled After configuration click Save to save the above settings into the gateway or click Reset to restore the configurations After changing the IP address you shall log in the gateway again using your new IP address 3 2 Management WEB Management WEB Port 4080 Access Setting IPs in Whitelist 201 123 115 201 123 113 IP Address IP addresses are separated by SoH Management Contig SSH yes ONo o3H Port KR Remote Data Capture Config Remote Data Capture Oves L SYSLOG Parameters SYSLOG Yes Mo server Address 427 0 0 1 SYSLOG Level ERROR Time Parameters NTP
42. ferentiated services code point By default it is disabled Sets the priority of the voice media for DSCP The voice media with a bigger value has a higher priority The value range is 0 63 with the default value of 46 SMG SBO Series Gateway User Manual Version 1 6 2 Page 16 ynway Synway Information Engineering Co Ltd Sets the priority of the signal control for DSCP The signal control with a bigger Signal Control o value has a higher priority The value range is 0 63 with the default value of 26 Calls from SIP Trunk Once this feature is enabled the gateway will only accept the calls from the IP Address only addresses set in SIP Settings gt SIP Trunk By default it is disabled Switch Signal Port if If the SIP registration fails the SIP signaling port N will switch to N 1 for a new SIP Registration registration It will continue until the registration succeeds Failed The work period for the gateway You can specify a certain period for the gateway to Working Period E Penod make calls By default the gateway is allowed to make calls any time in the day 24 erio Hours Sets the maximum time for the SIP channel to wait for the answer from the called Maximum Wait party of the outgoing call it initiates If the call is not answered within the specified Answer Time time period it will be canceled by the channel automatically The default value is 60 calculated by s Sets the maximum time for the SIP c
43. fiasGCanfig ini SIPACALLOLIT siptrunk used 1 1 from 201 123 112 66 2015 08 13 08 18 58 Add Config SMGConfid ini SIP4CALLOUT siptrunk_address0 1 2017 123 112 66 from 201 123 112 56 2075 08 13 03 18 58 Add Config SMGConfig ini SIP4C 4LLOLIT siptrunk_port0 1 5063 from 201 123 112 66 2015 08 13 03 18 58 Add Confia sMGConfia ini SIPACALLOLIT siptrunks maxresourced 1 512 from 201 123 112 68 2015 08 13 03 18 58 amp dd Canfia sSMGConfig ini SIPACALLOLIT siptrunks maxinresaurce 1 512 from 201 123 112 56 2075 08 13 03 18 58 Add Config SMGConfig ini SIP4C4LLOLIT siptrunks_anyipcallinO 1 gt from 201 123 112 66 2075 06 13 09 18 56 Add Config SMGContid ini sIP4CALLOUT siptrunks_ warktimespan4ip 1 0 fram 201 123 112 66 2015 08 13 08 18 58 Add Canfia sllGCanfig ini SIPAC ALL OLUT siptrunks timespan start4ip0 1 08 00 00 from 201 123 112 66 2015 08 13 09 18 56 Add Config SMGConfid ini sIP4CALLOUT siptrunks_timespantend4ip0 1 11 30 00 from 201 123 112 56 2015 08 13 03 18 58 Add Canfia sMGCaonfig ini SIPACALLOLIT siptrunks lan 1 20 from 201 123 112 65 2015 08 13 03 18 58 amp dd Canfia sMGConfiga ini SIP4CALLOLIT siptrunks transprotecol0 1 0 from 201 123 112 55 2015 08 13 03 18 58 Add Confia sMGConfia ini SIPACALLOLIT siptrunks AudiacodecList 1 5 7 131 8 38 4 86 from 201 123 112 56 2015 08 13 09 19 05 Mad Confia sdGCaonfia ini SIPACALLOLIT sip callaut trunk max 1 22 from 201 123 112
44. fort to ensure the accuracy of this document but does not guarantee the absence of errors Moreover Synway assumes no responsibility in obtaining permission and authorization of any third party patent copyright or product involved in relation to the use of this document SMG SBO Series Gateway User Manual Version 1 6 2 Page iii ynway Synway Information Engineering Co Ltd Revision History Teen ome mens Version 1 0 0 2015 05 Initial publication Note Please visit our website htto www synway net to obtain the latest version of this document SMG SBO Series Gateway User Manual Version 1 6 2 Page iv ynway Synway Information Engineering Co Ltd Chapter 1 Product Introduction Thank you for choosing Synway SBO Series Gateway The Synway SBO series gateway products hereinafter referred to as SBO gateway are mainly used for connecting IP or enterprise PBX with the IP telephony network or IP PBX It provides such functions as transcoding routing number filtration number manipulation and so on Currently only SBO500 is available for you 1 1 Typical Application SBO Gateway C PDA IP Phone IP Phone QU Si Router S S Figure 1 1 Typical Application SMG SBO Series Gateway User Manual Version 1 6 2 IMS Server LAN Page 1 ynway Synway Information Engineering Co Ltd 1 2 Feature List Basic Features Description IP Call Call initiated from IP to a designated SIP
45. hannel to wait for the RTP packet If no RTP Maximum Wait RTP packet is received within the specified time period the channel will enter the Time pending state automatically and release the call The default value is 0 calculated by s 3 3 2 SIP Trunk By default there is no available SIP trunk information Click Add New to add a new SIP trunk See Figure 3 10 for the SIP trunk adding interface SMG SBO Series Gateway User Manual Version 1 6 2 Page 17 Cvnway Synway Information Engineering Co Ltd oP Trunk Remote Address Remote Port 5060 WAN Option MET 1 v Transport Protocol UDP Outgoing Voice Resource 512 Incoming Voice Resource 512 Working Period kel 24 Hours Check Codec Check Codec Wii G711A iv 5 2 GT11U sw le G723 w biz G729 ww biz AMR aw Figure 3 10 Add New SIP Trunk The table below explains the items shown in Figure 3 10 Wem Descipl n ooo Index The unique index of each SIP trunk Address of the SIP trunk i e the IP address or domain name of the remote SIP Remote Address terminal which will establish call conversation with the gateway Remote Port Port of the SIP trunk Wan Option Select the network port which used for WAN The default setting is NET 1 Max Voice l Maximum number of voice channels allocated by the SIP trunk to the gateway Channels Outgoing Voice Maximum number of voice channels for the outgoing calls allocated by the SIP Resour
46. he settings See Figure 3 26 for the IP IP Routing Rule Configuration Interface Check Index Call Initiator CallerlD Prefix CalleelD Prefix Number Filter Call Destination Description Modify F 63 SIP Trunk Group 0 none SIP Trunk Group 1 default e F 62 SIP Trunk Group 3 i none SIP Trunk Group 2 default e Check All Uncheck All Inverse Clear All Add New 2 items Total 20 ltems Page 1 1 First Previous Next Last Goto Page 1 sl 1 Pages Total Figure 3 26 IPIP Routing Rule Configuration Interface Click Modify in Figure 3 26 to modify a routing rule See Figure 3 27 for the IP gt IP routing rule modification interface The configuration items on this interface are the same as those on the Add New Routing Rule IP IP interface Note that the item Index cannot be modified IP PSTM Routing Rule Index Call Initiator SIP Trunk Group 0 Callerld Pretix 333 1 3 444 5 9 CalleelD Prefix Call Destination PCM Trunk Group 0 Description default Figure 3 27 Modify Routing Rule IP gt IP To delete a routing rule check the checkbox before the corresponding index in Figure 3 26 and click the Delete button Check All means to select all available items on the current page Uncheck All means to cancel all selections on the current page Inverse means to uncheck the selected items and check the unselected To clear all routing rules at a time click the Clear All button in Figure 3 26 3 5 Number Filter Number Filter in
47. he interfaces buttons and LEDs illustrated above psn E RJ 45 Bandwidth 10 100 1 neh orones Self a a Bandwidth Self Adaptive Bandwidth Supported a 0 Auto MDI MDIX auo vomon swored Amount 000 1 Type RS 232 Baud Rate 115200 bps Connector RJ45 See Figure 1 5 for signal definition Data Bits 8 bits Stop Bit 1 bit Console Port Parity Unsupported Flow Control Unsupported Button Deseription O O O SMG SBO Series Gateway User Manual Version 1 6 2 Page 3 ynway Synway Information Engineering Co Ltd Power on off the SBO gateway You can turn on the two power keys at the same Power Key 4 time to have the power supply working in the hot backup mode Reset Button Restore the gateway to factory settings Description Indicates the power state It lights up when the gateway starts up with the power Power Indicator cord well connected Run Indicator Indicates the running status For more details refer to 1 4 Alarm Info Alarm Indicator Alarms the device malfunction For more details refer to 1 4 Alarm Info Link Indicator The green LED on the left of NET indicating the network connection status The orange LED on the right of NET whose flashing tells data are being ACT Indicator transmitted Note The console port is used for debugging While connection the transmitting and receiving lines of the gateway and the remote device should be cross linked That is connect the t
48. iod Maximum Wait Answer Time s Maximum Wait RTP Time s Figure 4 2 2 Add the IP addresses of the SIP terminal Synway Information Engineering Co Ltd LAN 1 201 123 112 199 wj A Enable 5060 Username of From Field Request Field v F Enable UDP Cl Enable Enable Cl Enable v Enable Cl Enable Cl Enable Cl Enable Cl enable v124 Hours 60 IT Operation Info ap 5 rell Check Index Remote Address Remote Port WAN Option Transport Protocol Outgoing Voice Resource Incoming Voice Resource Voice Code List Working Period Modif SIP Ei oO 0 201 123 112 219 5060 NET 1 UDP 512 512 G711A G711U G729 G722 iLBC G723 AMR 24 Hours a SIP Trunk i i i i i i i 201 123 112 2 506 IET 512 512 3711A G711U G729 G722 iLBC G723 AMR 24 s E SIP Register IS 1 201 123 112 211 5060 NET 1 UDP 512 512 G711A G711U iLBC G MR Hour ri SIP Account F 2 201 123 112 20 5060 NET 1 UDP 512 512 G711A G711U G729 G722 iLBC G723 AMR 24 Hours d i are o 3 20112311215 5060 NET1 UDP 512 512 GT11A G711U G729 G722 BC G723 AMR 24 Hours Media F 5 201 123 112 228 5060 NET 1 UDP 512 512 G711A G711U G729 G722 iLBC G723 AMR 24 Hours i IO Route Y L il I E mumberFiter Y 0 em M MM em FI Num Manipulate 5 items Total 20 Items Page 1 1 First Previous Next Last Goto Page 1 1 Pages Total Figure 4 3 3 Add
49. is available The channel receives the ringback tone and is waiting Wait Answer l for the called party to pick up the phone Ringing The channel is in the ringing state Talking The channel is in a conversation Pending The channel is in the pending state Dialing Mw The channel is dialing The channel is waiting for the message from remote PBX Wait Message Note The gateway provides the fuzzy search feature on this interface After you click any characters on Figure 3 5 and press the F button the search box will emerge on the right top of this page Then you can input the key characters and the gateway will locate the channel on which there is an ongoing call that conforms to the fuzzy search condition Take an example As shown in Figure 3 6 after we input the character 114 to the search box and click the Search button the gateway does a fuzzy search and locates that the ongoing call whose CalledID contains the character 114 occurs on Channel 4 of Channel Group 1 SMG SBO Series Gateway User Manual Version 1 6 2 Page 11 Cvnway Synway Information Engineering Co Ltd E T CSS ECC EUER EGER CR FORCE CHIC EIC EEG EE EE EIE EE ESI EG EE Channel Group c222222022222 Channel Group c222c222229222 Channel Groups GSSGG00000600 Channel Group SSGooCCG00008 voan GO Jogogg 2222222022222 Channel Grup 926902002602002000002020020020025 cc SSES IIIe REECH SEET EE EE REEEEEEEEEEEEEEEEEEEEEEEEEEEEE EE wc
50. l Wode2 EnableBond 0 BondEthz SysInfo w E NE Reset Note You shall restart the service or system to validate the modified configuration file Figure 3 53 Configuration File Interface See Figure 3 53 for the Configuration File interface including two files SMGConfig ini and ShConfig ini You can check and modify the items in these configuration files through this interface Configurations about the gateway server such as route rules number manipulation number filter and so on are included in SMGConfig ini Configurations about the board are included in ShConfig ini You can modify these configurations on the interface directly and then click Save to save the above settings into the gateway or click Reset to restore the configurations SMG SBO Series Gateway User Manual Version 1 6 2 Page 49 Cvnwav Synway Information Engineering Co Ltd 3 7 6 Signaling Capture Choose a network interface to capture pee e doa LAN 1 201 123 112 198 Capture RTP Destination Address for Syslog 201 123 112 254 Choose a channel aroup and channel ta Co NM X SE Channel Group v Channel 0 w record data Choose a channel group and channel to eo a Channel Group Channel 18 record data Figure 3 54 Signaling Capture Interface See Figure 3 54 for the Signaling Capture interface Data Capture is used to capture data on the network interface you choose Click Start to start capturing data 1024000 packets
51. le 0 0 none none none 0 none none none 1 none none none none none none none none 2 none none none none none none none none 3 none none none none none none none none 4 none none none none none none none none _ 5 none none none none none none none none 6 none none none none none none none none 7 none none none none none none none none 8 none none none none none none none none 9 none none none none none none none none 10 none none none none none none none none 11 none none none none none none none none lt gt Delete Clear All Add New 12 Items Total 15 Items Page 1 1 First Previous Next Last Goto Page 1 v 1 Pages Total Figure 3 38 Filtering Rule Setting Interface See Figure 3 38 for the Filtering Rule Setting Interface A new filtering rule can be added by the Add New button on the bottom right corner of the list in the above figure See Figure 3 39 for the Filtering Rule Adding interface SMG SBO Series Gateway User Manual Version 1 6 2 Page 37 Cvnway Synway Information Engineering Co Ltd Filtering Rule Mo ech ra CallerlD Whitelist none CalleelD Whitelist none CallerlD Blacklist none CalleelD Blacklist none CallerlD Pool in Whitelist none CallerlD Pool in Blacklist none CalleelD Fool in Whitelist none CalleelD Fool in Blacklist none Original CalleelD Fool in Whitelist j none
52. le Enable Enable gm C PA DO Enable lenable 124 Hours 080000 L1t3000 0 C pg Page 15 ynway Synway Information Engineering Co Ltd Figure 3 9 SIP Settings Interface oee Figure 3 9 for the SIP settings interface where you can configure the general SIP parameters After configuration click Save to save your settings into the gateway or click Reset to restore the configurations If a dialog box pops up after you save your settings asking you to restart the service do it immediately to apply the changes Refer to 3 7 16 Restart for detailed instructions The table below explains the items shown in Figure 3 9 Item Description Auto Change The SIP address of WAN will automatically shift to another LAN if the default one is Default Gateway unavailable By default the feature is disabled Monitoring port of SIP signaling Range of value 5001 65535 with the default SIP Signaling Port value of 5060 There are two optional ways to obtain the calling party number from Username of Obtain CallerID from From Field or from Displayname of From Field The default value is from Username of From Field Obtain CalleelD There are two optional ways to obtain the called party number from To Field or from from Request Field The default value is from Request Field NAT Traversal Sets whether to enable the NAT traversal By default this feature is disabled
53. may lead to a drop in performance or unexpected errors SMG SBO Series Gateway User Manual Version 1 6 2 Page 6 ynway Synway Information Engineering Co Ltd Chapter 3 WEB Configuration 3 1 System Login Type the IP address into the browser and enter the login interface See Figure 3 1 8 Windows Security The server 201 123 115 17at SMG requires a username and password Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection Remember my credentials L t Figure 3 1 Login Interface The gateway only serves one user whose original username and password are both admin You can change the username and the password via System Tools Change Password on the WEB interface For detailed instructions refer to 3 7 14 Change Password After login you can see the main interface as below UM Operation Info A System Info IP Status LAN 1 Call Count MAC Address 80 7B 85 10 04 92 IP Address 201 123 112 17 255 255 255 0 201 123 112 254 DNS Server SIP 2 Receive Packets All 176962 Error 0 Drop 0 Route x Transmit Packets AJ 595 Error 0 Drop 0 Current Speed Receive 1 3 KB s Transmit638 Bis ke Number Filter x Work Mode 100Mb s Full Duplex 1 MM F Num Manipulate LAN 2 eR System Tools x MAC Address 80 7B 85 10 04 93 IP Address 192 168 0 101 255255 255 0 192 168 0 254 DNS S
54. n this interface are the same as those on the Add New SIP Trunk Group interface Index Description default SIP Trunk Select Mode Increase v SIF Trunks kel smi loin Figure 3 21 Modify SIP Trunk Group To delete a SIP trunk group check the checkbox before the corresponding index in Figure 3 20 and click the Delete button Check All means to select all available items on the current page Uncheck All means to cancel all selections on the current page Inverse means to uncheck the selected items and check the unselected To clear all SIP trunk groups at a time click the Clear All button in Figure 3 20 SMG SBO Series Gateway User Manual Version 1 6 2 Page 27 ynway Synway Information Engineering Co Ltd 3 3 6 Media Settings DTMF Transmit Mode IRFC2833 RFC2833 Payload 101 RTF Port Range 5000 10000 silence Suppression Noise Reduction Enable JitterMode Static Mode JitterBufferims 100 Jitter UnderrunLead ms 400 JitterDverrunLeadims a0 Voice Gain Output from IP dB CODEC Setting Priarity Packing Time ms Bit Rate kbps 4 v G722 e cn Un d pa p a IHC Figure 3 22 Media Settings Interface oee Figure 3 22 for the media settings interface where you can configure the RTP port and payload type depending on your requirements After configuration click Save to save your settings into the gateway or click Reset
55. non condensing NET Amount 2 10 100 1000 BASE TX RJ 45 Self adaptive bandwidth supported Auto MDI MDIX supported Console Port Amount 1 RS 232 Baud rate 115200bps Connector RJ45 See Hardware Description for signal definition Data bits 8 bits Stop bit 1 bit Parity unsupported Flow control unsupported SMG SBO Series Gateway User Manual Version 1 6 2 Note Follow the above settings to configure the console port or it may work abnormally Power Requirements Input power 100 240V AC Maximum power consumption lt 22W Signaling amp Protocol SIP signaling SIP V1 0 2 0 RFC3261 Audio Encoding amp Decoding G 711A 64 kbps G 711U 64 kbps G 729 8 kbps G723 5 3 6 3 kbps G722 64 kbps AMR 4 75 5 15 5 90 6 70 7 40 7 9 5 10 20 12 20 kbps iLBC 15 2 kbps Sampling Rate 8kHz Safety Lightning resistance Level 4 Page 62 ynway Synway Information Engineering Co Ltd Appendix B Troubleshooting 1 What to do if forget the IP address of the SBO gateway Long press the Reset button on the gateway to restore to factory settings Thus the IP address will be restored to its default value NET1 192 168 1 101 NET2 192 168 0 101 2 In what cases can I conclude that the SBO gateway is abnormal and turn to Synway s technicians for help a During runtime the run indicator does not flash or the alarm indicator lights up or flashes and such error still exists even after you restart the device
56. or restore it to factory settings b Voice problems occur during call conversation such as that one party or both parties cannot hear the voice or the voice quality is unacceptable Other problems such as abnormal SIP trunk status inaccessible calls failed registrations and incorrect numbers are probably caused by configuration errors We suggest you refer to Chapter 3 WEB Configuration for further examination If you still cannot figure out or solve your problems please feel free to contact our technicians 3 What to do if cannot enter the WEB interface of the SBO gateway after login This problem may happen on some browsers To settle it follow the instructions here to configure your browser Enter Tools gt Internet Options Security Tab and add the current IP address of the gateway into Trusted Sites If you change the IP address of the gateway add your new IP address into the above settings SMG SBO Series Gateway User Manual Version 1 6 2 Page 63 ynway Synway Information Engineering Co Ltd Appendix C Technical sales Support Thank you for choosing Synway Please contact us should you have any inquiry regarding our products We shall do our best to help you Headquarters Synway Information Engineering Co Ltd http www synway net 9F Synway D amp R Center No 3756 Nanhuan Road Binjiang District Hangzhou P R China 310053 Tel 86 571 88860561 Fax 86 571 88850923 Technical Support T
57. ormation Engineering Co Ltd interface You can click Refresh to obtain the latest call count information click Download to download the call count logs The table below explains the items shown in Figure 3 7 em Desepten oo Reason to release the call Normal call clearing Total number of the calls which are normally cleared Cancelled by calling Total number of the calls which are cancelled by the calling party party Total number of the calls which fail as the called party has been occupied and User busy replies a busy message No answer from Total number of the calls which fail as the called party does not pick up the call in a user long time or the calling party hangs up the call before the called party picks it up Routing failed Total number of the calls which fail because no routing rules are matched Resource Total number of the calls which fail because no voice channel is available unavailable Total number of the calls which fail as the called party number does not conform to Call failed B the number receiving rule or for relative reasons Total number of the calls which fail because of other reasons Total number of the calls on each state The percentage of the calls with a release cause to total calls 3 3 SIP Settings SIP Settings includes six parts SIP SIP Trunk SIP Register SIP Account SIP Trunk Group and Media See Figure 3 8 SIP is used to configure the general SIP parameters SIP Trunk is us
58. ransmitting line of the gateway to the receiving line of the remote device and vice verse The figure below illustrates the signal definition of the console port on the gateway Gateway RX Gateway TX H No ROO C GND Figure 1 5 Console Port Signal Definition For other hardware parameters refer to Appendix A Technical Specifications 1 4 Alarm Info The SBO gateway is equipped with two indicators denoting the system s running status Run Indicator green and Alarm Indicator red The table below explains the states and meanings of the two indicators Run Indicator Go out Device is working normally Upon startup Device is running normally Alarm Indicator Light up In runtime Device goes abnormal System is abnormal Note The startup process consists of two stages System Booting and Gateway Service Startup The system booting costs about 1 minute and once it succeeds both the run indicator and the alarm indicator light up Then after the gateway service is successfully started and the device begins to work normally the run indicator flashes and the alarm indicator goes out e During runtime if the alarm indicator lights up or flashes it indicates that the device goes abnormal If you cannot figure out and solve the problem by yourself please contact our technicians for help Go to Appendix C Technical sales Support to find the contact way SMG SBO Series Gateway User Manual Version 1 6 2
59. s kernel version CPU usage processes memory usage startup information NET status and etc Currently the gateway only provides the community string for information acquisition The table below explains the configuration items shown in the above figure mem Desripio SNMP Server Address IP address of SNMP Monitoring Port Monitoring Port for SNMP on the gateway Read only Community String Community string used for information acquisition You can query OID object identification trees 1 3 6 1 4 1 2021 51 at the SNMP Client to obtain the signaling link status and the line synchronization information SMG SBO Series Gateway User Manual Version 1 6 2 Page 48 ynway Synway Information Engineering Co Ltd 3 7 5 Configuration File sMGcConfig ini Version GWSwrV 1 0 1 KernelvzLinux mpces09som 2 6 34 85 Thu Dec 6 10 12 48 CST 2012 VebV 1 0 1 Gpldv 245621 586 HWaddr1 00 04 8F EF 03 02 HWaddrz2 00 04 8F EF 03 02 ebCtrl LocalAddress 127 0 0 1 LocalPort 1001 Monitor Local ddress 127 0 0 1 LocalPort 1002 AutaExec 1 LIpgradeExecP athz usr lacal apache htdacs RecUparade IniFilePathz mntiflash DiaitsMMapRuleslnfa DigitsMapRulesNum 1 NetContig BondFlag 0 Ip amp ddr12201 123 112 17 Subnet1 2255 255 255 0 Gateway1 201 123 112 254 DNS1 0 0 0 0 CheckNett 0 IpAddr2 192 168 0 101 Subnet2 255 255 255 0 Gateway2 192 168 0 254 DNS2 0 0 0 0 CheckNet2 0 Hode
60. st at a time click the Clear All button in Figure 3 29 Note If a CallerlD or CalleelD set in the whitelist is the same as one in the blacklist it will go invalid That is the blacklist has a higher priority than the whitelist The total amount of numbers in both whitelist and blacklist cannot exceed 5000 3 5 2 Blacklist V LD DIOC KS e pms SD DOG KS DE Check Group No No in Group CalleriD Modify Check Group No No in Group CalleelD Modify Fi 0 0 78 P E 0 0 111 L 0 1 111 L Clear All Add New Clear All Add New Note You shall restart the service to validate the settings on this page Figure 3 34 Blacklist Setting Interface The Blacklist Setting interface is almost the same as the Whitelist Setting interface only the whitelist changes to the blacklist See Figure 3 34 The configuration items on this interface are the same as those on the Whitelist Setting interface Figure 3 30 Figure 3 31 Note The lacklist has a higher priority than the whitelist That is if the same number exists in both blacklist and whitelist the number in blacklist has priority SMG SBO Series Gateway User Manual Version 1 6 2 Page 35 ynway Synway Information Engineering Co Ltd 3 5 3 Number Pool Group No No in Group Initiative Number Number Amount 0 0 10000 0 1 1000 gigigigigigigigimgimig s R Ro RO Ro Ro RO RO Ro Ro Ro Ro B Clear All Add New Figure 3 35 Number Pool Setting Interface
61. sword the new username and password and then confirm the new password After configuration click Save to apply the new username and password or click Reset to restore the configurations After changing the username and password you are required to log in again SMG SBO Series Gateway User Manual Version 1 6 2 Page 56 ynway Synway Information Engineering Co Ltd 3 7 15 Device Lock Please selectthe condition ta lock the device Mate The device will be locked upon any one of the selected items being madified WI v aip Password Confirm Password Figure 3 63 Device Lock Configuration Interface See Figure 3 63 for the Device Lock Configuration interface You can select at least one item as the condition to judge whether to lock the gateway or not that is as long as an item in the selected list is modified the gateway will be locked You shall enter the password which is necessary for device unlock After your setting click Lock and the device lock interface will be locked See Figure 3 64 To unlock the interface enter your password and click the Unlock button Password Figure 3 64 Unlock Device Interface As long as an item in the selected list in Figure 3 64 is modified the gateway will be locked See Figure 3 65 In such case only five pages including system info network setting change password device lock and restart are available Calls will all be rejected Enter the device unlock interface Figure 3 64
62. t CallerlDs CalleelDs in a same group CallerID in the whitelist which must be filled in with numbers or indicating any CallerID string and can not be left empty Example 135 1 denotes any CallerlDs which start from 135 and end with 1 will be accepted CalleelD in the whitelist which must be filled in with numbers or indicating any CalleelD string and can not be left empty Example 135 1 denotes any CalleelDs which start from 135 and end with 1 will be accepted After configuration click Save to save the above settings into the gateway or click Close to cancel the settings Click Modify in Figure 3 29 to modify the CallerID or CalleelD whitelist See Figure 3 32 Figure 3 33 for CallerlDs CalleelDs on the Whitelist Modification interface The configuration items on this interface are the same as those on the Add New CallerlIDs CalleelDs in Whitelist interface The item Group No cannot be modified Mesi E LESE m Whitelist No in Group Gallery Figure 3 32 Modify CallerIlDs in Whitelist SMG SBO Series Gateway User Manual Version 1 6 2 Page 34 ynway Synway Information Engineering Co Ltd CalleelDs in Whitelist Group Mo in Group CalleelD Figure 3 33 Modify CalleelDs in Whitelist To delete a CallerlDs CalleelDs in the whitelist check the checkbox before the corresponding index in Figure 3 29 and click the Delete button To clear all CallerlDs CalleelDs in the whiteli
63. to restore the configurations If a dialog box pops up after you save your settings asking you to restart the service do it immediately to apply the changes Refer to 3 7 16 Restart for detailed instructions The table below explains the items shown in Figure 3 22 wm scription O DTMF Transmit Sets the mode for the IP channel to send DTMF signals The optional values are Mode RFC2833 In band and Signaling with the default value of RFC2833 Payload of the RFC2833 formatted DTMF signals on the IP channel Range of RFC2833 Payload value 90 127 with the default value of 101 SMG SBO Series Gateway User Manual Version 1 6 2 Page 28 ynway Synway Information Engineering Co Ltd Supported RTP port range for the IP end to establish a call conversation with the RTP Port Range lower limit of 6000 and the upper limit of 60000 and the difference between larger than 2048 The default value is 6000 10000 Sets whether to send comfort noise packets to replace RTP packets or never to send RIP packets to reduce the bandwidth usage when there is no voice signal Silence throughout an IP conversation The optional values are Enable and Disable with the default value of Disable Suppression Note When G723 is selected as CODEC this configuration setting will turn to Enable automatically l Once this feature is enabled the volume of the noise accompanied with the line will Noise Reduction Sa be reduced automatically
64. trunk via routing and number manipulation Number Manipulation Peels off some digits of a phone number from left right or adds a prefix suffix to a phone number VoIP Routing Routing path from IP to IP SIP Signaling Supported protocol SIP V1 0 2 0 RFC3261 Voice CODEC G 711A G 711U G 729 G723 G722 AMR iLBC DTMF Mode RFC2833 SIP INFO INBAND Network Protocol SR protocol TCP UDP HTTP ARP RARP DNS NTP TFTP TELNET ep Ise e Irene Software Upgrade SUED of user interface gateway service kernel and firmware upgrades based Tracking Test Support of Ping and Tracert tests based on WEB SysLog Type Three options available ERROR WARNING INFO 1 3 Hardware Description The SBO gateway features 1U rackmount design and integrates embedded LINUX system within the POWERPC DSP hardware architecture It has 2 Kilomega Ethernet ports NET1 and NET2 on the chassis See the figures below for SBO500 appearance SMG SBO Series Gateway User Manual Version 1 6 2 Page 2 ynway Synway Information Engineering Co Ltd LAN2 Indicator LAN1 Indicator Alarm Indicator Power 1 Indicator Console Port Reset Button Power 2 Indicator Run Indicator Figure 1 2 Front View 220V AC Power2 220V AC Power 1 Grounding Stud Network Port Power1 Key Power2 Key Figure 1 3 Rear View Screw Holes for Foot Bracket Holes Figure 1 4 Left View The table below gives a detailed introduction to t
65. ts 20 Items Page 1 1 First Previous Next Last Go to Page 4 v 1 Pages Totsl Figure 3 45 IPIP CalleelD Manipulation Interface SMG SBO Series Gateway User Manual Version 1 6 2 Page 42 ynway Synway Information Engineering Co Ltd 3 System Tools System Tools is mainly for gateway maintenance It provides such features as IP modification time synchronization data backup log inquiry and connectivity check See Figure 3 46 for details it System Tools Network Management IP Routing Table SNMP Config Config File signaling Capture signaling Call Track PING Test TRACERT Test Modification Record Backup amp Upload Factory Reset Upgrade Change Password Device Lock Restart Figure 3 46 System Tools SMG SBO Series Gateway User Manual Version 1 6 2 Page 43 Cvnway Synway Information Engineering Co Ltd 3 7 1 Network IP Address I 201 123 112 17 subnet Mask LI Default Gateway D DNS Server P speed and Duplex Mode Automatic Detection IP Address I 182 168 0 101 subnet Mask U Default Gateway Dj 192 168 0 254 DNS Server P 0 0 0 0 speed and Duplex Mode Automatic Detection BOND Setting BOND Yes Ho BOND Address ren Figure 3 47 Network Settings Interface See Figure 3 47 for the Network Settings interface A gateway has two network ports each of which can be configured with independent IP address subnet mask default gat
66. unk Settings Interface Click Modify in Figure 3 11 to modify a SIP trunk See Figure 3 12 for the SIP trunk modification interface The configuration items on this interface are the same as those on the Add New SIP Trunk interface SMG SBO Series Gateway User Manual Version 1 6 2 Page 19 lt SSynway Index Remote Address Remote Port WAN Option Synway Information Engineering Co Ltd oP Trunk 201 123 112 656 5069 MET 1 he Transport Protocol UDP Outgoing Voice Resource 512 Incoming Voice Resource 512 Working Period Check Codec 4 v 2 v 24 Hours Check Codec Me fe 2o w Figure 3 12 Modify SIP Trunk To delete a SIP trunk check the checkbox before the corresponding index in Figure 3 11 and click the Delete button Check All means to select all available items on the current page Uncheck All means to cancel all selections on the current page Inverse means to uncheck the selected items and check the unselected To clear all SIP trunks at a time click the Clear All button in Figure 3 11 3 3 3 SIP Register By default there is no SIP register available on the gateway Click Add New to add them manually See Figure 3 13 SMG SBO Series Gateway User Manual Version 1 6 2 Page 20 ynway Synway Information Engineering Co Ltd SP Register Index SIP Trunk No Username Password Register Address Register Fort 5060 Domain Name
67. vnway Synway Information Engineering Co Ltd IP 1P C allerlD Manipulation Index 53 Call Initiator CallerlD Pretix CalleelD Prefix With Original CalleelD stripped Digits from Left stripped Digits from Right Reserved Digits from Right Prefix to Add suffix to Add Description default Figure 3 44 Modify IP gt IP CallerlD Manipulation Rule To delete a number manipulation rule check the checkbox before the corresponding index in Figure 3 43 and click the Delete button Check All means to select all available items on the current page Uncheck All means to cancel all selections on the current page Inverse means to uncheck the selected items and check the unselected To clear all number manipulation rules at a time click the Clear All button in Figure 3 43 3 6 2 IP to IP CalleelD The number manipulation process for IP gt IP CalleelD is almost the same as that for IP IP CallerlD only the number to be manipulated changes from CallerlD to CalleelD See Figure 3 45 for IP IP CalleelD manipulation interface The configuration items on this interface are the same as those on P2IP CalleriD Manipulation Interface Figure 3 43 Check Index Call Initistor CalleriD Prefix CalleelD Prefix With Original CalleelD Stripped Digits from Left Stripped Digits from Right Reserved Digits from Right Prefix to Add Suffix to Add Description Modify L1 3 IP T u d faul a Check All Uncheck All Inverse Clear All Add New 1 items To
68. when the Reserved Digits D n value of this item is less than the length of the current number will some digits be from Right deleted from left otherwise the number will not be manipulated Prefix to Add Designated information to be added to the left end of the current number Suffix to Add Designated information to be added to the right end of the current number More information about each number manipulation rule Note The number manipulation is performed in 5 steps by the order of the following configuration items Stripped Digits from Left Stripped Digits from Right Reserved Digits from Right Prefix to Add and Suffix to Add After configuration click Save to save the settings into the gateway or click Close to cancel the settings See Figure 3 43 for IP gt IP CallerlD Manipulation Interface Index Call Initiator CalleriD Prefix CalleelD Prefix With Original CalleslD g 83 SIP Trunk Group 0 No 1 0 0 default 2 Check All Uncheck All Inverse Clesr All Add New t Items Total 20 Items Page Figure 3 43 IP gt IP CallerID Manipulation Interface Click Modify in Figure 3 43 to modify a number manipulation rule See Figure 3 44 for the IP gt IP CallerlD manipulation rule modification interface The configuration items on this interface are the same as those on the Add IP gt IP CallerID Manipulation Rule interface Note that the item Index cannot be modified SMG SBO Series Gateway User Manual Version 1 6 2 Page 41 C
69. y Bound Address Externally Bound Port and Authentication Username be shown Externally Bound EM Externally bound IP address for registration Address Externally Bound Externally bound port for registration Port Authentication uM Authentication username for registration Username After configuration click Save to save the settings into the gateway or click Close to cancel the settings See Figure 3 14 for the SIP Register Information List Checl Index SIP Trunk No Username Register Adress Register Port Domain Name Register Expires s Register Status IMS Networl Externally Bound Address 0 D 100 201 123 115 26 5060 3600 Failed No lt gt Check Al Uncheck All Inverse Clear All Add New 1items Total 20ltems Page 1 1 First Previous Next Last Goto Page 1 sl 1 Pages Total Figure 3 14 SIP Register Information List Click Modify in Figure 3 14 to modify a SIP register The configuration items on the SIP Register Modification Interface are the same as those on the Add New SIP Register interface SMG SBO Series Gateway User Manual Version 1 6 2 Page 22 ynway Synway Information Engineering Co Ltd SP Register Index SIP Trunk No Username Password Register Address 201 123 115 26 Register Port 5060 Domain Name Register Expires s INS Network Externally Bound Address Externally Bound Port Authentication Username Figure 3 15 SIP Register Modification Interface