Bonnie DC UPS Quick Guide
Contents
1. when the mains is normal The UPS is overload Remove some loads first Before reconnecting equipment please verify that the load matches the UPS capability specified in the specs UPS fault Return the unit to service center The mains is normal but yellow LED is lighting Power cord is loose 6 Specifications Reconnect the power cord properly Model Bonnie 30 Bonnie 50 CAPACITY 30 W 50 W INPUT Voltage 230 VAC 110 VAC or 220 VAC Voltage Range 160 280 VAC 80 140 VAC or 160 280 VAC Frequency 50 Hz 60 Hz or 50 Hz OUTPUT Output Voltage or 12VDC 24VDC Dual outputs 6VDC 12VDC 2x 12VDC Output Voltage Regulation 12V 15 and 12 6V 10 15 and 12 24V 5 Transfer Time Oms EFFICIENCY AC Mode 70 75 Battery Mode gt 90 95 BATTERY Type 12V 9Ahx1 Charging Voltage 1817M E0725 Charging At no load 3A 2 8A 110 VAC Current 2 3A 220 VAC At full load 0 7 A lt 1A Typical Recharge Time 4 6 hours recover to 90 capacity PHYSICAL Dimension DxWxH mm 228 x 82 5 x 207 Net Weight kgs 3 ENVIRONMENT Humidity 0 90 _ Temperature 0 40 C non condensing
2. Bonnie DC UPS Quick Guide I Introduction The UPS is exclusively designed for communication devices such as hub switch and modem Featuring with dynamic voltage regulator the UPS can ensure stable DC power to connected loads as utility The built in DC start function enables the UPS to be started up without a supply of AC power The main features of this UPS are listed below Dual DC outputs Microprocessor controlled guarantees high reliability Compact size for standing and mounting flexibility Supports solar powered devices and communication applications Auto restart while AC is recovering Off mode charging Overload protection and short circuit protection y J Product Overview Front View Power switch AC mode indicator green lighting Battery mode indicator yellow lighting indicates battery mode yellow flashing indicates low battery Fault indicator red lighting Back View Output options Model Output options Bonnie 30 6VDC and 12VDC 12VDC and 24VDC Bonnie 50 2x 12VDC AC input 2 x DC output screw terminals see output options table 3 Installation amp Initial Startup NOTE Before installation please inspect the unit Be sure that nothing inside the package is damaged Placement amp Storage Conditions Install the UPS in a protected area that is free of excessive dust and has ad
3. N To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants See the specifications for the acceptable temperature and humidity range CAUTION To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces CAUTION Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS CAUTION Do not plug the UPS input into its own output CAUTION Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit CAUTION In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS CAUTION Do not attach a power strip or surge suppressor to the UPS CAUTION If the UPS is with metal chassis for safety purpose grounding is a must during UPS installation in order to reduce leakage current below 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or s
4. equate air flow Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature and humidity is outside the specific limits Please check the specs for the limitations Connect to Utility and Charging Before initial use please plug in the AC input cord to the wall outlet and turn on the UPS for charging For the best results suggest to charge the battery at least 6 hours before initial use The UPS charges its battery while connecting to the utility with power on 6 hours Connect the Loads There are two options for output terminals 6VDC 12VDC and 12VDC 24VDC Please verify acceptable voltage of connected device before connecting the wires Then follow terminal printing to connect the positive and negative terminals to the devices Turn On Off the Unit Turn on the UPS unit by pressing and holding the power switch for 4 seconds Turn off the UPS unit by pressing and holding again the power switch for 4 seconds Connected devices will be protected by the UPS when turning on the UPS Indicators amp Alarm Table for Operation Conditions Visual Indications Alarm AC mode Green LED lighting Off Battery mode Yellow LED lighting Sounding every 10 seconds Low battery at battery mode Yellow LED flashing Fault Red LED lighting Sounding every second Continuously sounding Important Safety Warning SAVE THESE INSTRUCTIONS CAUTIO
5. ervice work inside the UPS is necessary CAUTION Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries CAUTION When replacing the batteries use the same number and type of batteries CAUTION Internal battery voltage is 12Vdc Sealed lead acid 6 cell battery CAUTION Do not dispose of batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes CAUTION Unplug the UPS prior to cleaning and do not use liquid or spray detergent CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed before replacing batteries 1 Remove watches rings or other metal objects 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal 5 Trouble Shooting Use the table below to solve minor problems Problem Probable Cause Solution No LED display on the front panel Low battery Charge the UPS at least 6 hours Battery fault Replace the battery with the same type of battery The UPS is not turned on Press the power switch again to turn on the UPS Alarm continuously sounds