1. KEYPAD MODULE PC4702BP BELL PANEL COMBUS A PC4204CF is added when additional 1g aan COMBUS power is required to power from PC4020CF modules downstream from PC4204CF with up to 16 PC4204CF s per system 4 conductor SECURITY unshielded y SYSTEM station wire MODULES PC4820 see PC4020 spec sheet ACCESS CONTACT CONTROL CONTACT MODULE Ordering Information PC4020CF control panel with fire option c w PC4020CF main control module PC4701 fire module PT1016 transformer PC4050CR red cabinet installation manual user manual and programming worksheets module mounting hardware and 32 EOL resistors PC4020CFAR as PC4020CF but with attack resistant cabinet Keypads are not supplied with the main panel at least one fire keypad with red bezel is required per system Select from the following keypads LCD4520 alphanumeric keypad with red bezel without function keys LCD4520T as LCD4520 but with wall tamper switch LCD4521 alphanumeric keypad with red bezel and 5 function keys LCD4521T as LCD4521 but with wall tamper switch LCD4500 T LCD4501 T are identical to the above but do not have red bezels USA CANADA UL864 Control Units System ULC S527 Central Station Fire Alarm L CS A M SS WF ULC S302 Central amp Monitoring Station UL1610 Central Station Burglar Alarm Burglar Alarm UL609 Local Burglar Alarm ULC S30
2. to 14Ah capacity Battery charger is supervised for opens and is protected by PTC over current device which is self restoring input power 16VAC 40VA ground fault detection built in and enabled by connecting earth ground to EGND terminal on PC4020CF main panel Note maximum power from the PC4020CF panel power supply may be limited by its ability to maintain the required standby time The PS4350R external battery charger can be used to assure maximum panel loading capability and provide the required standby See the PC4020 Installation Manual for panel loading and standby calculations Mechanical Specifications operating environment 32 to 122 F 0 to 50 C 90 RH non condensing PC4050CR red cabinet surface mount AC wiring compartment hinged door with screw closure provision for door keylock provision for door and wall tamper switches space for one 12 volt 7Ah lead acid rechargeable battery 14 8 H x 12 0 W x 4 9 D 37 6 x 30 5 x 12 5cm Compatible Smoke Detectors e 2 wire smoke detectors DSC MN220 220T DSC AMS 220 220T addressable Digital Security Controls es eae 1645 Flint Road Downsview ON Canada M3 2J6 Security Products 1998 Printed in Canada 04 98 Typical System Arrangement ADDRESSABLE DETECTORS Two addressable loops per system home run T tapped or star connected using 2 conductor unshielded station wire LCD4520 21 PC4204CF FIRE POWER RELAY
3. 3 Local Alarm Commercial UL365 Police Station Burglar Alarm Burglary UL985 Household Fire Warning ULC S310 Household Burglar Alarm UL1023 Household Burglar Alarm ULC S545 Household Fire Warning UL294 Access Control Distributed by
4. MAXSYS INTEGRATED SYSTEMS TECHNOLOGY OZ 107200 16 TO 128 ZONE COMMERCIAL FIRE CONTROL PANEL The PC4020CF is the UL listed commercial fire version of the PC4020 security control panel As such the PC4020CF has the same system expandability and features as the PC4020 plus added features and expandability for commercial fire applications as described herein PC4020CF Panel Fire Features In addition to all of the features of the PC4020 see separate spec sheet the following are additional hardware and software features of the PC4020CF for use in commercial fire applications e PC4020CF control panel is supplied in red system cabinet c w PC4701 fire module 16VAC 40VA transformer e PC4701 fire module includes 1 Class B Style B two wire smoke detector zone accommodating 30 12VDC compatible detectors 1 Class B Style B waterflow zone two supervised communicator outputs terminal connection for house telephone 1 fire alarm actuated relay Form C rated 2A 30VDC 1 fire trouble actuated relay Form C rated 2A 30VDC e up to 112 DSC AMS 220 addressable smoke detectors can be added to the system spread over one or both of the addressable loops addressable fire zones may be programmed as the following types standard fire zones auto verify fire zones delayed fire zones for residential only e all hardwired zones on the PC4020CF can be programmed as fire zones with the following zone ty
5. c assignments Silence Trouble Silence Bells Fire Reset Fire Drill Lamp Test LCD4520 same as LCD4500 but with red bezel North American 29002961 PC4020CF Panel Electrical Specifications e bell output 12VDC 700mA max continuous use for burglary only PTC over current protected self restoring e AUX output 12VDC 500 mA max e SAUX output 12VDC 300mA max SAUX output is normally 12VDC and power is removed upon activation Typically used to reset 4 wire smoke detectors Note total for AUX output and SAUX output is 500mA max e g If the SAUX output is loaded to 200mA then only 300mA remains for the AUX output e AUX and SAUX outputs protected by a common PTC over current device which is self restoring PGM outputs as standard PGM outputs 12VDC 50mA max each PGM outputs are normally unpowered and switch to 12VDC upon activation as addressable outputs 12VDC 170mA max each Note PGM outputs are individually programmable as addressable loops or as general purpose PGM outputs Combus 500mA max from the PC4020CF main panel additional power is provided by PC4204CF modules Maximum Combus capacitance is 80nF which is typically 4 000 feet of 22 AWG wire Consult wire Mfg specifications Note total loading for the Bell output AUX SAUX PGM1 PGM2 and the Combus must not exceed 900 mA battery charger up to 350 mA to charge 12 volt lead acid batteries up
6. pes standard fire zones waterflow zones auto verify fire zones delayed fire zones for residential only fire supervisory zones e programmable fire alarm output patterns steady temporal pattern CA pattern pulsed or strobe fire e programmable fire bell options bell cut off time and fire silence inhibit time e all PC4702BP bell outputs are supervised for short circuit open circuit ground fault e alarm autoscroll displays fire alarms and selected trouble conditions at 2 second intervals on system LCD keypads Items displayed include first fire alarm zone label fire alarm zone label fire supervisory zone label fire bell has been silenced bell zone trouble failure to communicate e fire drill activates main bell output and PC4702BP fire bell outputs according to their programmed fire signalling modes without activating other functions and without sending reporting codes to the central station Keypads display Fire Drill in Progress during test If an actual alarm occurs during test the test is automatically cancelled and the standard fire alarm functions occur e fire inspector test ensures that all fire initiating devices are communicating and are supervised All test results are logged to the system event buffer e scheduled smoke detector tests 50 time date smoke detector test schedules programmable by partition for addressable detectors only e lamp test use keypad
7. to activate annunciator lights for 2 seconds System Expansion In addition to all of the modules available for the PC4020 see separate spec sheet the following are specially designed for use with the PC4020CF in commercial fire applications e PC4702BP fire system bell panel provides 2 supervised Class B Style Y bell outputs c w battery charger 28VAC 170VA transformer and cabinet with space for two 12 volt 4Ah sealed lead acid rechargeable batteries e PC4204CF fire system quad relay power supply module similar to PC4204 but c w battery charger 16 VAC 40VA transformer and cabinet with space for two 12 volt 7Ah sealed lead acid rechargeable batteries e PC4612 fire zone annunciator 12 zone surface mount keypad style plastic annunciator Includes common fire zone trouble fire bell zone trouble common system trouble and AC on indicators system can also include PC4632 and PC4664 thirty two and sixty four zone point graphic annunciators to annunciate fire zones security zones and common system indications e PS4350R fire system external battery charger for longer standby time required by listed fire systems e keypads with red bezels for fire application at least one LCD4521 or LCD4520 must be used with the PC4020CF keypad piezo buzzer will sound continuously if communication is lost with control panel LCD4521 same as LCD4501 but with red bezel Five function keys have fire system specifi