Contents
1. Exit Program Option Cancel Exit User Programming Mode Command Description Address 01 Set User Code 1 User Master Code Default 1234 02 Set User Code 2 03 Set User Code 3 04 Set User Code 4 05 Set User Code 5 06 Set User Code 6 07 Set User Code 7 08 Set User Code 8 09 Set User Code 9 10 Set User Code 10 11 Program Duress Code 12 Real time clock setting 13 Set automatic arm time 14 Set automatic disarm time 15 Set ON time 1 for H A Module 16 Set OFF time 1 for H A Module 17 Set ON time 2 for H A Module 18 Set OFF time 2 for H A Module 19 Set ON time 3 for H A Module 20 Set OFF time 3 for H A Module 21 Set ON time 4 for H A Module 22 Set OFF time 4 for H A Module 23 Set ON time 5 for H A Module 24 Set OFF time 5 for H A Module 25 Set ON time 6 for H A Module 26 Set OFF time 6 for H A Module 27 Set ON time 7 for H A Module 28 Set OFF time 7 for H A Module 29 Set ON time 8 for H A Module 30 Set OFF time 8 for H A Module 31 Program telephone number 1 32 Program telephone number 2 33 Program telephone number 3 34 Program telephone number 4 35 Program telephone number 5 eleck L2000 USER MANUAL V1 2 Enter User Programming Mode USER MASTER CODE Ensure all systems are disarmed Press to cancel off unwanted entries Press followed by your 4 digits User Master Code to access into User Programming Mode F
2. Press and hold 7 for 2 seconds The memory provided in the system is capable of recording the most recent alarm condition The Memory Indicator will blink when there is an alarm triggered and the zone being triggered will be noted down into the keypad 1 Press and hold the 7 key for 2 seconds The Memory Indicator will turn ON and the keypad will beep 2 times indicating that the user is currently in View Memory mode 2 The zone s that had been trespassed or triggered will be shown on the Zone Indicator 3 Press key to exit Turning On Off Keypad Sound Press and hold for 2 seconds The beeping sounds of the keypad can be turned off on by pressing and holding the key for 2 seconds 11 eloeck L2000 USER MANUAL V1 2 PART VI EMERGENCY SITUATION Fire Mode Press and hold F key for 2 seconds This function will trigger the Fire Alarm it can also be triggered by a smoke detector that is set as fire zone Press this key only during emergency where immediate assistance is required 1 Press and hold the F key for 2 seconds to trigger the Fire Alarm 2 The siren will sound and the system will send a Fire Reporting Code to the central monitoring station 3 Enter a valid 4 digits user code to silent the alarm Panic Mode Press and hold P key for 2 seconds This function will trigger the Panic Alarm it can also be triggered by any fixed or remote panic button that had been installed Press this key only dur
3. View Memory this key will activate View Memory mode H A Zone this key will activate Home Automation mode Chime Zone this key will trigger Chime mode Clear Key this key will clear or cancel undesired entries Holiday Mode this key will trigger Holiday mode Enter Key this key will confirm commands entered Fire Alarm This key will trigger Fire Alarm Panic Alarm This key will trigger Panic Alarm Medical Alarm This key will trigger Medical Alarm 4 el eck L2000 USER MANUAL V1 2 PART IlI CALL IN OUT FUNCTION Call In Function Wait for Enter i System Report Answer User Master Number of Beeps represent 4 beeps Code triggered zone s 2 Force Arm Disarm System 3 ON OFF Siren 4 Turn ON H A Point 5 Turn OFF H A 1 to 8 H A Point 1 to 8 H A Point Point 6 Bypass Zone 7 Unbypass Zone 8 Check H A Status 1 to 8 Zone Number 1 to 8 Zone Number 1 to 8 H A Point 1 to 8 Zone Number Call Out Function Answer Call Wait for Answer 4 beeps Enter User Master Code o Check Zone Status Chart Call In Call Out Function Chart The previous chart illustrated the flow of the alarm panel s Call In and Call Out function The system will automatically cut off telephone line if the user did not provide the app
4. 13 to enter Auto Arm Time Setting Key in the auto arm time in 24 hour format e g 5 45pm is key in as 1745 Press key to confirm the setting Press key to exit the setting mode press another key to exit User Programming Mode Auto Disarm Time Setting EO 2 14 Auto Disarm Time Enter User Programming Mode Key in 14 to enter Auto Disarm Time Setting Key in the auto disarm time in 24 hour format e g 5 45pm is key in as 1745 Press key to confirm the setting Press key to exit the setting mode press another key to exit User Programming Mode Program H A Auto ON Time 15 17 19 21 23 25 27 29 Auto ON Time 1 8 Noted that there are 8 sets of H A modules each modules are controlled by different set of ON time hence we have 8 different sets of H A Auto ON Time setting 1 2 Enter User Programming Mode Key in 15 to gain access to first Auto ON Time setting or Key in 17 to gain access to second Auto ON Time setting or 15 elercik L2000 USER MANUAL V1 2 aw Key in 19 to gain access to third Auto ON Time setting or Key in 21 to gain access to fourth Auto ON Time setting or Key in 23 to gain access to fifth Auto ON Time setting or Key in 25 to gain access to sixth Auto ON Time setting or Key in 27 to gain access to seventh Auto ON Time setting or Key in 29 to gain access to eighth Auto ON Time setting Key in the auto O
5. The system will provide an Exit Delay time for the user to exit the premises via ENTRY EXIT zone before setting the system to arm state e The users are allowed to enter or exit the premises via ENTRY EXIT zone ONLY e Upon entry the users are provided with Entry Delay time to disarm the system Timer Auto Arming This option allows the system to automatically Arm by itself according to a set schedule The system will be armed in Force Arm mode when the system timer reaches an Auto Arm time The Auto Arm Timer can be set from Part VI User Programming Mode section Program Auto Arm Timer eleck L2000 USER MANUAL V1 2 Telephone Remote Arm This function allows the user to remotely arm your facilities outside of the premises using any DTMF telephone or GSM hand phone The system will be armed in Force Arm mode when the user enters a valid User Code via hand phone or telephone Please refer Part Ill Call In Out Function chapter for telephone remote arming procedure The telephone number can be set from Part VII User Programming Mode section Program Telephone Number eleck L2000 USER MANUAL V1 2 PART V DISARM BYPASS amp MISCELLANEOUS FUNCTIONS Disarm Using Keypad USER CODE 1 Enter the premises via ENTRY EXIT zone the ENTRY Delay time begins to count down the moment this zone is violated Entering via other zones will trigger the alarm The keypad will beep in the duration of the delay time Key in the
6. can trust The AL2000 alarm panel is intended for basic yet optimal security assurance for you and your family It is easy to install easy to use and easy to maintain Just follow the instructions in this manual to fully utilize the operations of this device and optimize your security Your security system consists of a main control panel one or more keypads eight 2 2kO resistors one jumper cap one 2A 250V fuse two Philips screws one 240V to 15V step down transformer an installer manual and a user manual The main control panel is contained inside an enclosure along with the components However the AL2000 does not 100 guarantee the safety against burglary fire or other losses Any alarm systems are subjected to failure due to variety of reasons Hence please be noted that e The intruders may be able to gain access to your property through unprotected premises or being able to bypass the alarm system by any possible means e The security system may seize functioning without power supply i e AC power supply being cut off back up power supply battery is missing dead or improperly installed e The alarm device may not be able to alert people if it is being set up on the other side of closed or partly closed premises e Transmission of signal is done using telephone line transmission hence any form of sabotage on the telephone line or the control station may render the device useless e Smoke detector may not be able to sense a
7. system will be armed instantly with the exclusion of Day Stay zones if applied 1 2 3 4 Armed Indicator will illuminate and the keypad will project 2 beeping signals as armed D c Ensure all zone indicators are distinguished and the protected premises are closed DO NOT open the ENTRY EXIT zone Press and hold 2 key for 2 seconds confirmation Any Day Stay Zones will be automatically bypassed User will be given a delay time to disarm the system upon entering the protected premises via EXIT ENTRY zone Night Arm Press and hold 3 for 2 seconds Ideal for Night time protection while users remained in the premises the system will be armed instantly with the exclusion of Night Stay zones if applied 1 2 3 4 Armed Indicator will illuminate and the keypad will project 2 beeping signals as armed Do Ensure all zone indicators are distinguished and the protected premises are closed DO NOT open the ENTRY EXIT zone Press and hold 3 key for 2 seconds confirmation Any Night Stay Zones will be automatically bypassed There s No delay time to disarm the system upon entering any protected zones Any violation will trigger the alarm instantly eleck L2000 USER MANUAL V1 2 Force Arm Press and hold 5 for 2 seconds The system will be armed after the Exit Delay time and within this timeline some violated zones are allowed to be temporarily bypassed When the violated zones resume the zone will
8. zone that you wish to bypass and press key to confirm the entry The keypad will beep 2 times upon confirming 4 Repeat Step 3 for other zones that wished to be bypassed 5 To delete a Bypass zone key in the zone that wished to be deleted and press key to cancel Repeat this step for cancelation of other Bypass Zones 6 Once done press key to exit the setting The keypad will provide a long beep and the indicators will stop blinking 7 The Bypass Zone s will be shown as the blinking zone s on the keypad s Zone Indicators 8 Once armed these Bypass Zones are allowed for entries without triggering the alarm 9 All Bypass Zones will be automatically un bypassed once the system is disarmed and should be reset before the next arming Delete Bypass Zone Press and hold 4 for 2 seconds Press and hold the 4 key for 2 seconds to access into Bypass Zone setting Key in the Bypass Zone that wished to be deleted and press key to confirm the entry Repeat Step 2 for other Bypass Zones cancelation Once done press key to exit the setting Poe M System Troubleshoot Press and hold 6 for 2 seconds The system is equipped with troubleshooting function to monitor for possible faulty conditions The Service Indicator will turn ON when of the faulty condition is detected and the indicator will turn OFF once the problem is fixed 1 Press and hold the 6 key for 2 seconds to access into Service menu 2 The P
9. 4 digits user code to disarm the system If error is made upon entering the user code press key to cancel the previous transaction and re enter the code 5 The Armed Indicator light will extinguish and the beeping will stop indicating the system is disarmed 6 If no valid user code is keyed into the system within the ENTRY Delay timeline the alarm will trigger 7 The keypad can be programmed to accept a certain number of key entry tries with Keypad Lock Counter Once the trial limit is exceeded the keypad will be locked and non responsive to any other entries for a set period of time determined by Keypad Lock Time The ENTRY and EXIT delay timeline can also be adjusted These however are set by your installer during installation Please contact your installer if there are changes that wish to be made 8 Flashing Memory Indicator indicates that there had been an intrusion Call for assistance the intruder may still be around omn Remote Control Disarming This option allows the user to immediately disarm the system using a remote control or a key switch Simply press the remote control button or key switch to instantly disarm the system Timer Auto Disarming The alarm system can be programmed to automatically disarm according to a pre planned schedule same as how the system can be set to automatically arm but instead it is controlled by Auto Disarm Timer The Auto Disarm Timer can be set from Part VI User Programmi
10. Mode 3 Once entered Walk Test the PWR ARM and SERV LED will blink 4 Test the protected zones by invading the premises the alarm will be triggered for 2 seconds 5 If alarm signals are not detected upon violation of the premises kindly consult your system provider 6 Press key to exit the Walk Test Mode CMS Test 2 The CMS Test allows user to test the functionality of the CMS Reporting function of the alarm system 1 Press key to clear off any unwanted transactions 2 Press key follow by 2 then another key to enter CMS Test Mode 3 A CMS Test Code will be sent to the central monitoring station to simulate CMS Reporting procedure 4 Wait 2 minutes if CMS Reporting fails a trouble condition will be registered to the system 5 Press and hold 6 key for 2 seconds to troubleshoot the condition kindly consult your system provider for technical assistance Siren Test 3 The Siren Test allows user to test the functionality of the siren 1 Press key to clear off any unwanted transactions 2 Press key follow by 3 then another key to enter Siren Test Mode 3 The siren will trigger for 3 seconds 4 If no siren was heard kindly consult your system provider Strobe Light Test 1 4 The Strobe Light Test allows user to test the functionality of the strobe light 1 Press key to clear off any unwanted transactions 2 Press key
11. N time in 24 hour format e g 5 45pm is key in as 1745 Press key to confirm the setting Press key to exit the setting mode repeat Step 2 to program other auto ON time or press another key to exit User Programming Mode Program H A Auto OFF Time 16 18 20 22 24 26 28 30 Auto OFF Time 1 8 Noted that there are 8 sets of H A modules each modules are controlled by different set of OFF time hence we have 8 different sets of H A Auto OFF Time setting 1 2 gi e Ka Enter User Programming Mode Key in 16 to gain access to first Auto OFF Time setting Key in 18 to gain access to second Auto OFF Time setting Key in 20 to gain access to third Auto OFF Time setting Key in 22 to gain access to fourth Auto OFF Time setting Key in 24 to gain access to fifth Auto OFF Time setting Key in 26 to gain access to sixth Auto OFF Time setting Key in 28 to gain access to seventh Auto OFF Time setting Key in 30 to gain access to eighth Auto OFF Time setting Key in the auto OFF time in 24 hour format e g 5 45pm is key in as 1745 Press key to confirm the setting Press key to exit the setting mode repeat Step 2 to program other auto ON time or press another key to exit User Programming Mode Program Telephone Number 31 35 Phone Number 1 5 This alarm system is equipped with notification function where the system will call out to user phone to report on int
12. WR SERV and MEM indicators will blink and the keypad will beep two times to indicate correct entry into the System Troubleshoot option 3 The turned ON zone indicator s represent the problem s occurred in the system The zone indications are shown by the following table 10 eleck L 2000 USER MANUAL V1 2 Zone 1 indicator AC loss Zone 2 indicator Battery low voltage Zone 3 indicator Siren fail both siren slots have to be connected with load Zone 4 indicator Strobe light fail Zone 5 indicator Telephone line fail 4 Press key to exit to the main menu Chime Mode Press and hold 9 for 2 seconds zone number The Chime Mode allows user to monitor the premises even when the system is disarmed When the chime zone is violated the keypad will project beep signal WITHOUT triggering the alarm All zones are set as Chime Zones by default 1 Press and hold the 9 key for 2 seconds 2 The keypad will beep 2 times and the PWR SERV and MEM indicators will blink 3 Enter the zone that you wish to monitor as Chime Zone followed by key 4 Repeat Step 3 to set more zones as Chime Zones The zones that had been programmed as Chime Zones are indicated by the illuminated zone indicators Once Completed the entry press key to exit the setting To erase an existing Chime Zones simply repeat Step 3 on existing zones The zone indicators will be extinguished D View Memory
13. ase ensure that any unused User Codes are erased from the system Erase User Code sie aed hea Command Address 0000 0000 Enter User Programming Mode Enter Command Address that you wish to erase Enter 0000 and re enter this number followed by key to delete the User Code Repeat Step 2 3 to erase other User Codes 14 eleck L 2000 USER MANUAL V1 2 Program Duress Code 11 New Code Re enter New Code The Duress Code is for emergency usage where the user is being forced by the intruder to disarm the system The Duress code will send a Duress Reporting Code to the central monitoring station for notification Pan Enter User Programming Mode Key in 11 to enter Program Duress Code Enter a 4 digit code follow by re entering the code as confirmation Key in the key to save the data into the system Press key to exit this setting option press another key to exit the User Programming Mode Real Time Clock Setting n SON 12 Current Time Enter User Programming Mode Key in 12 to enter Real Time Clock Setting Key in time in 24 hour format e g 5 45pm is key in as 1745 i e 17 45 Press key to confirm the time setting Press key to exit time setting mode press another key to exit User Programming Mode Auto Arm Time Setting Gl O JO gt 13 Auto Arm Time Enter User Programming Mode Key in
14. be protected again 1 Press and hold 5 key for 2 seconds 2 The Armed Indicator will illuminate and the keypad will start beeping for the duration of the Exit Delay Bypassed zones in this timeline will be shown by flashing zone indicators 3 User is provided with an Entry Delay time to disarm the system upon entering the protected premises via ENTRY EXIT zone Holiday Arm Press and hold 0 for 2 seconds Ideal when all occupants users are away for a long period of time ex holiday The alarm will be armed in AWAY ARM mode and the Home Automation Modules will automatically turn ON OFF to simulate occupancy 1 Ensure all zone indicators are distinguished and the protected premises are closed 2 Press and hold 0 key for 2 seconds 3 The Armed Indicator will illuminate and the keypad will start beeping for the duration of the Exit Delay Bypassing any protected zones at this moment will cause the keypad s Zone Indicator to flash 4 Exit the premises ONLY via the ENTRY EXIT zone 5 User will be provided with ENTRY Delay time to disarm the system upon entering the protected premises via ENTRY EXIT zone 6 The random ON OFF function of the Home Automation Modules will be deactivated and the system will resume the preset Home Automation settings Remote Control Arming This option is for arming with a remote control or a key switch unit Once the remote control button is pressed it will set the system in Away Arm mode which means e
15. e eck Total Security Solution You Cau hrast AL2000 ALARM SYSTEM USER MANUAL V1 2 elock L2000 USER MANUAL Part Part II Part III Part IV Part V Part VI Part VII Table of Content Introduction Knowing Your Keypad Call In Out Function Arming Your System Away Arm Day Arm Night Arm Force Arm Holiday Arm Remote Control Arming Timer Auto Arming Telephone Remote Arm Disarm Bypass amp Miscellaneous Functions Disarm Using Keypad Remote Control Disarming Timer Auto Disarming Telephone Remote Disarm Turn ON OFF Home Automation H A Point Bypass Zone Delete Bypass Zone System Troubleshoot Chime Mode View Memory Turning On Off Keypad Sound Emergency Situation Fire Mode Panic Mode Medical Mode Duress Code User Programming Mode User Programming Code Summary Enter User Programming Mode Exit User Programming Mode Program New amp Changing Existing User Code s Erase User Code Program Duress Code Real Time Clock Setting Auto Arm Time Setting Auto Disarm Time Setting Program H A Auto ON Time Program H A Auto OFF Time Program Telephone Number of CO Q N N N N 9 9 9 V1 2 el eck L 2000 USER MANUAL Part VIII System Testing Walk Test CMS Test Siren Test Strobe Light Test Battery Test 17 17 17 17 18 V1 2 elock L2000 USER MANUAL V1 2 PART INTRODUCTION Thank you for purchasing ELOCK security product the total security solution that you
16. fire hazard if the smoke does not reach the detector e The alarm may not function properly if it is not maintained accordingly Please test your alarm on weekly basis to ensure that the systems are functioning e Please subscribe or continue to subscribe to insurance since the alarm panel DO NOT 100 guarantees your safety IMPORTANT It is crucial that the AL2000 is being tested out frequently weekly to ensure that the device is working properly at all time The run test procedure can be done by referring to the steps provided in PART VIII of the user manual If the device is not working accordingly kindly contact your system installer for troubleshooting and services elock L2000 USER MANUAL V1 2 PART Il KNOWING YOUR KEYPAD Power Indicator light up when power is ON Armed Indicator light up when system is armed Memory Indicator will flash when alarm triggered Service Indicator light up when system require service Keypad Lock Indicator light up when keypad is locked Zone Indicators light up when the zone is selected show the status of the selected zone Number Keys Away Arm this key will activate Away Arm function Day Arm this key will activate Day Arm function Night Arm this key will activate Night Arm function Bypass Zone this key will trigger Bypass mode Force Arm this key will trigger Force Arm mode Service Key this key will activate Service mode
17. follow by 4 then another key to enter Strobe Light Test Mode 3 The strobe light will flash for 10 seconds 4 Ifthe strobe light is not showing any signals kindly consult your system provider 17 elock L2000 USER MANUAL V1 2 Battery Test 5 The Battery Test allows user to test the functionality of the back up battery 1 2 3 4 Press key to clear off any unwanted transactions Press key follow by 5 then another key to enter Battery Test Mode Wait 10 seconds if back up battery fails a trouble condition will be registered to the system Press and hold 6 key for 2 seconds to troubleshoot the system kindly consult your system provider for technical assistance 18
18. ing emergency where immediate assistance is required 1 Press and hold the P key for 2 seconds to trigger the Panic Alarm 2 The siren will sound and the system will send a Panic Reporting Code to the central monitoring station 3 Enter a valid 4 digits user code to silent the alarm or it will stop automatically after the Siren Timeout Period Medical Mode Press and hold M key for 2 seconds This function will trigger the Medical Alarm Press this key only during emergency where immediate assistance is required 1 Press and hold the M key for 2 seconds to trigger the Medical Alarm 2 The siren will sound and the system will send a Medical Reporting Code to the central monitoring station 3 Enter a valid 4 digits user code to silent the alarm Duress Code This is a special 4 digits user code that is advisable to use under critical situation where the user is being forced by an intruder to disarm the system The Duress Code will disarm the system and at the same time sending a Duress Reporting Code to the central monitoring station to acquire assistance The Duress Code can be set in Part VI User Programming Mode section Program Duress Code chapter 12 elock L2000 USER MANUAL V1 2 PART VII USER PROGRAMMING MODE User Programming Code Summary Enter User Programming Mode User Master Code Enter Key
19. ng Section Program Auto Disarm Timer Telephone Remote Disarm The system can be remotely disarmed from outside of the premises using any DTMF telephone or GSM hand phone Please refer Part Ill Call In Out Function chapter for telephone remote disarming procedure Turn ON OFF Home Automation H A Point Press and hold 8 for 2 seconds H A point number 1 8 1 Press and hold the 8 key for 2 seconds 2 The keypad will beep 2 times and the PWR SERV and MEM indicators will blink eleck L 2000 USER MANUAL V1 2 3 Key in the H A point number followed by key to manually turn ON OFF the H A point Keypad will beep 2 times and the zone indicator of the H A point will light up to indicate the H A point is turned ON or turn off to indicate the H A point is turned OFF 4 Repeat Step 4 to turn ON OFF other H A points 5 Press the key to exit this setting mode Bypass Zone Press and hold 4 for 2 seconds A Bypass Zone is a zone that is set to allow the user to enter the premises without triggering the alarm even when the system is armed The Bypass Zones will be un bypassed each time the system is disarmed and need to be reset before the next arming session This setting can only be done before arming the system 1 Press and hold the 4 key for 2 seconds 2 The PWR SERV and MEM Indicators will blink and keypad will beep 2 times to indicate that the user is now entered Bypass Zone setting 3 Key in the
20. or any wrong entries press key to cancel off and repeat Step 3 Press key to confirm the code insertion If a false User Master Code is provided you will hear a long beep Repeat Step 2 4 to key in the code The Power and Memory Indicators will blink and the keypad will beep two times if a valid code is provided Enter Command Address according to the settings that you desire to change and proceed with the rest of the programming procedures Exit User Programming Mode _ Press key to exit User Programming and return to normal mode The Power and Memory Indicators will stop blinking The keypad will project a long beep to indicate that you had exited the User Programming Mode Program New amp Changing Existing User Code s Command Address New Code Re enter New Code There are 10 User Codes allowed for the system all allocated in 10 different Command Addresses and the first user code User Master Code is set as 1234 by default 1 2 3 oF Enter User Programming Mode Enter Command Address that you wish to change There are 10 Command Addresses allocated for User Codes 01 10 Enter a 4 digit User Code that you wish to set for the system and re enter the code as confirmation of the code Key in the key once confirmed Repeat Step 2 4 for other user codes Press key to exit this setting option press another to exit User Programming Mode NOTE Ple
21. ropriate code for more than 3 times or did not key in any codes for more than 60 seconds System Indications 2 short beeps Indicates successful entry into a menu or option Multiple fast beeps Indicates false entry eleck L 2000 USER MANUAL V1 2 PART IV ARMING YOUR SYSTEM Away Arm USER CODE or Press and hold 1 for 2 seconds Ideal when all the occupants are out leaving the premises empty The system will provide users with enter or exit delay time to allow the user to enter or exit the premises ONLY via the ENTRY EXIT zone Once the delay time is up the premises will be armed 1 Ensure all zone indicators are distinguished and the protected premises are closed 2 Press key to cancel unintended operations 3 Key in the 4 digits user code For wrong entry press key and re enter the code The system will arm once the correct user code is entered 4 The Armed Indicator will illuminate and the keypad will project beeping signals in the duration of Exit Delay Bypassing any protected zones at this moment will trigger the alarm 5 Exit the premises ONLY via the ENTRY EXIT zone 6 The Away Arm can also be activated by simply press and hold 1 key for 2 seconds 7 User will be provided with ENTRY Delay time to disarm the system upon entering the protected premises via ENTRY EXIT zone Day Arm Press and hold 2 for 2 seconds Ideal for Day time protection while users remained in the premises the
22. rusion If the system failed to notify the number however the second contact number Telephone Number 2 will be used as back up This system comes along with 1 key contact and another 4 back up contacts at your disposal 1 2 9 gt O1 K Enter User Programming Mode Key in 31 to gain access into Program Telephone Number 1 setting Key in 32 to gain access into Program Telephone Number 2 setting Key in 33 to gain access into Program Telephone Number 3 setting Key in 34 to gain access into Program Telephone Number 4 setting Key in 35 to gain access into Program Telephone Number 5 setting Key in telephone number maximum of 10 digits length To delete phone number key in 0000000000 Press key upon confirmation Press key to exit this setting 16 eleck L 2000 USER MANUAL V1 2 PART VIII SYSTEM TESTING It is important to test the system frequently to ensure the functionality and reliability of the alarm devices equipped in the premises Users are advised to perform the testing at least once every 3 months If the system or any of the alarm devices are not functioning accordingly kindly contact your system provider for technical assistance Walk Test 11 The Walk Test allows user to test the functionality of the protected premises or zones 1 Press key to clear off any unwanted transactions 2 Press key follow by 1 then another key to enter Walk Test