1. 0001 0 1 0 Lo 1 Hi 2 P ON ACT2 Alarm 2 act setting range 0000 0001 0 1 0 Lo 1 Hi zo 40025 BAUD Baud rate setting range 0000 0002 0 2 0 2400 1 4800 2 9600 PARI Parity setting range 0000 0003 0 3 0 N 8 2 1 N 8 1 2 EVEN 3 0DD FRAME Frame setting range 0000 0001 0 1 O off 1 on
2. DISPLAY SETTING Display RPEr ASPA er ee Display Descriptions AIO Zero Adjustment azn A O Span Adjustment ASPA 1 Press ENT to enter this parameter the digit will be flashed 2 Press ENT again to move the digit Press f or can modify the value Move the digit to the 3rd or 4th digit to increase the speed of adjustment 3 Press ENT for 3 SEC to save the parameter and go to the next parameter EHH Error Code of Self Diagnosis Descriptions dot Input signal is over display range Max 9999 dof Input signal is under display range Min 1999 Err EEPROM reading writing suffers the interference about 1 million times Please checkt to the factory he wiring connection is correct first if the problem still exist please return the meter GSFL53 Modbus RTU Mode Protocol Address Map Data 16Bit 32Bit is 8000 7FFF 32768 32767 80000000 7FFFFFFF 2147483648 2147483647 Modbus Name Nescriptions 40001 DISPLY Current display range 0000 270F 0000 9999 40002 me KF K factor setting range 0001 270F 0001 9999 40003 ANLO Analog output low scale setting range 000 270F 0000 9999 40004 ANHI Analog output hi scale setting range 000 270F 0000 9999 40005 TBASE Sampling time base setting range 0001 270F 0001 9999 40006 AL1 Alarm 1 setpoint setting range 000
3. 270F 0000 999 9 40007 AL2 Alarm 2 setpoint setting range 000 270F 0000 999 9 40008 TOTAL Alarm total range 0000 5FSEOFF 0000 9999 Hi Bit 40009 Alarm total range 0000 5F5E0FF 0000 9999 Low Bit 40010 AVG Display average setting range 0001 0063 1 99 40011 SJ Hae Hea I eS SaaS S LCUT Display low cut setting range 0000 0063 00 99 40012 D D D 50 D D DDD 70 HYS1 Alarm 1 hysteresis setting range 0000 0063 00 99 40013 me HYS2 Alarm 2 hysteresis setting range 0000 00 63 00 99 40014 DELI Alarm 1 act delay time setting range 0000 0063 0 99 40015 DEL2 Alarm 2 act delay time setting range 0000 0063 0 99 40016 SB Alarm start band setting range 000 0063 0 99 40017 SDT Alarm 1 start delay time setting range 0000 0063 0 99 40018 ADDR Address setting range 0000 00FF 0 255 40019 DPK AlarmK factor decimal point setting range 0000 0003 0 1 0 0 1 1 2 2 3 3 40020 DP Decimal point settin g range 0000 0003 0 1 0 0 1 1 2 2 3 3 40021 22 5 222 2 2 2252 2222227 Dd D D D D D D D Unit Linear Speed unit setting 0 M3 1 Liter 2 C C 3 GAL 40022 CTIME Total time unit setting range 0000 0004 0 4 ES 40023 0 SEC 1 Min 2 HoUr 3 dAY 4 MontH ACT1 40024 SS E Qa Sm Se ee oS Se eS me Alarm 1 act setting range 0000
4. 4 DIGITAL FLOW SENSOR CNBR with 1 2 ALARMS ANALOG OUTPUT RS 485 MANUAL x Please understand key indicators amp functions at the first operation FRONT PANEL KEY FUNCTIONS amp WIRING CONNECTION EXC 5V IN GND M12 Connector Power 15 30V Output 4 20mA Common RX D TX D C1 E1 C2 E2 Ecom Ccom Key Name Synbo Enter Key amp Save Key Descriptions 1 In the measuring status press this key can enter to parameter pages ENT 2 In the parameter setting press this key for 3 sec can save the value amp go to next parameter Shift Key 1 In the parameter setting press this key can move the cursor left Up Key 1 Inthe parameter setting press this key can increase the digits Down Key amp 1 oct this key for 3 sec can enter to A O Adjusting K ghey 2 In the parameter setting press this key can decrease the digits PROGRAMMING MODE OPERATING PROCEDURES imn ILJ L LLJ Measuring Status Remark In any measuring pages press ENT for 3 secs can go back to the previous page and save the parameters after modification Press ENT P ess 73 sec 4 Plod Plod Enter Pass Code Enter Pass Cod Pass Code Eror OOOO HHHH Press ENT 3 sec Press ENT 3 sec rof e 555 APEr Alain Setting System Setti AlO Zero roup Grou Adjustment Oy Ao AO Oy AO ALI dPE RSPR Alarm 1 Setpoint K Factor Decimal Setting Poi
5. cription 1 While the dispaly reach the Alarm start band range the Alarm will be on after this time P S This parameter must be use with Sb together 3 Press ENT to enter this parameter Press ENT again to movethe digit Press f or can modify the value range 0 99 sec 3 Press ENT for 3 SEC to save the parameter and go to the next parameter RS 485 oo SETTING GROUP PROCEDURE Name Descriptions 1 Press ENT to enter this parameter Press ENT again to move the digit Press f or can modify the value range 0 255 2 Press ENT for 3 SEC to save the parameter and go to the next parameter 1 Press ENT to enter this parameter Press f or can modify the value range 96400 4800 2400 bps 2 Press ENT for 3 SEC to save the parameter and go to the next parameter 1 Press ENT to enter this parameter Press fT or can modify the value range n 8 2 n 8 1 EvEn odd 2 Press ENT for 3 SEC to save the parameter and go to the next parameter 1 Press ENT to enter this parameter Press f or can modify the value range on Hi gt gt Lo off Lo gt gt Hi 2 Press ENT for 3 SEC to save the parameter and go to the next parameter Address Setting Addr Baud Rate Settin AUG Parity Check Setting PAri Frame Setting coo nb oFF FrAM A O SETTING Press for 3 sec can enter to P Cod page if the pass code is correct Press ENT for 3 sec can enter to
6. etpoint Lo Alarm on while the display lower than setpoint Range Hi Alarm setpoint Lo lt Alarm setpoint 1 Press ENT to enter this parameter press f or can modify the value 2 Press ENT for 3 SEC to save the parameter and go to the next parameter Description 1 If the Alarm actions is Hi the display must lower than Setpoint HYS value the Alarm will be off 2 If the Alarm actions is Lo the display must lower than SetpointtHYS value the Alarm will be off 3 Press ENT to enter this parameter Press ENT again to movethe digit Press f or can modify the value range 0 99 4 Press ENT for 3 SEC to save the parameter and go to the next parameter Description 1 If the value is 5 while the display reaches the Alarm setpoint Alarm will be on after 5 sec 2 Press ENT to enter this parameter Press ENT again to movethe digit Press f or can modify the value range 0 99 sec 3 Press ENT for 3 SEC to save the parameter and go to the next parameter Description If the value is 5 if the display is under 5 Alarm will not be ON If this value is5 while the display reaches the Alarm start band range the Alarm will be on after Sdt time Press ENT to enter this parameter Press ENT again to movethe digit Press f or can modify the value range 0 99 sec Press ENT for 3 SEC to save the parameter and go to the next parameter XThis function can prevent the wrong action by starting current Des
7. for 3 SEC to save the parameter and go to the next parameter 1 The display is 4 0 to output 4mA this value must be 4 0 Press ENT to enter this parameter Press ENT again to move the digit Press f or can modify the value range 0 9999 2 Press ENT for 3 SEC to save the parameter and go to the next parameter Example 1 The display is 100 0 to output 20mA this value must be 100 0 Press ENT to enter this parameter Press ENT again to move the digit Press f or can modify the value range 0 9999 2 Press ENT for 3 SEC to save the parameter and go to the next parameter ALARM roP SETTING GROUP PROCEDURE While Pass Code is correct Press ENT for 3 sec can select ROP Setting Group Alarm 1 Setpoint Alarm 2 Setpoint Setting Al2 AL Action Setting ACt1 AL2 Action Setting ACt2 AL1 Hysteresis Setting HYS1 AL2 Hysteresis Setting HSY2 AL1 Run Delay Setting dEL1 AL2 Run Delay Setting dEL2 AL Start Band Setting sb AL Start Delay Time Setting Sdt Descriptions Example 1 The alarm is on while the display is 50 0 the value must be set for 50 0 Press ENT to enter this parameter Press ENT again to move the digit Press f or can modify the value range 0 9999 2 Press ENT for 3 SEC to save the parameter and go to the next parameter Description Hi Alarm on while the display higher than s
8. he parameter and go to the next parameter Press ENT to enter this parameter press f or can modify the K Factor range Press ENT for 3 SEC to save the parameter and go to the next parameter Press ENT to enter this parameter press f or can modify the flow unit Leter Gal M3 CC Press ENT for 3 SEC to save the parameter and go to the next parameter Press ENT to enter this parameter press f or can modify the time unit sec min hour day month 2 Press ENT for 3 SEC to save the parameter and go to the next parameter Press ENT to enter this parameter press f or can modify the rate decimal point Press ENT for 3 SEC to save the parameter and go to the next parameter Press ENT to enter this parameter press f or can modify the oun time Press ENT for 3 SEC to save the parameter and go to the next parameter Press ENT to enter this parameter press f or can modify the display avera e 139 Press ENT for 3 SEC to save the parameter and go to the next parameter Press ENT to enter this parameter Press f or can modify the value range 0 99 Press ENT for 3 SEC to save the parameter and go to the next parameter Press ENT to enter this parameter press f or can modify the value range no unlock YES lock Press ENT for 3 SEC to save the parameter and go to the next parameter Press ENT to enter this parameter press f or can modify the value range 0 9999 Press ENT
9. nt Setting Oy he Ale EF Baud Rate Alarm 2 Setpoint K Factor Setting Setting Setting Vy 40 Vy 4 Vy 44 Phr Ei Rol Unik Parity Check AL1 Action F it aeons c Setting Scale Setting ouni O Vy Oy 4O FrAn RCE Rnko CEE Frame Setting Ae anon Scale Setting Total Teta Vy Sdt Hy5 LodE dP AL Start Delay AL1 Hysteresis Pass Code Decimal Point Time Settin Setting Setting OP Ya OF 40 Oy ad OF ho 5b ASE LoLl EbAS AL2 Hysteresis Key Lock Setting Sampling Time Setting etting Vy 46 A O Span Adjustment dEL I AL1 Run Delay Display Low Cut Display Average Setting i P Setting P Siting 2 AL2 Run Delay Setting SYSTEM SYS SETTING GROUP PROCEDURE While Pass Code is correct Press ENT for 3 sec can select SYS Setting Group Au PF AS 3 UE K Factor Decimal Point Setting dPk K Factor Setting kF Flow Unit Setting unit Total Time Unit Setting C tiME Setting AvG Setting LCUt AIO Low Scale Setting AnLo A O Hi Scale Setting AnHi rme oeo Press ENT to enter this parameter press f or can modify the K Factor decimal point Press ENT for 3 SEC to save t
Download Pdf Manuals
Related Search
Related Contents
Computer Science Dossier Guide GC Fuji IX GP GB E GC Fuji IX GP グラビティスタンド 2 ! ! User Manual UM EN NLC-COM-GSM Phénix + 650 - Accueil support VIsiole :: Accueil Sandberg Network Cable UTP Guía rápida para usuario del MilkSense & Bscale cabine de douche Dancing Queen - Maison-et Copyright © All rights reserved.